메뉴 건너뛰기




Volumn 70, Issue 1, 2013, Pages 127-135

Commissioning of MRI-only based treatment planning procedure for external beam radiotherapy of prostate

Author keywords

computed tomography substitute; gold seeds; image distortion; magnetic resonance imaging; prostate; radiotherapy planning

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DISEASES; GEOMETRY; GOLD; IONIZING RADIATION; MAGNETIC RESONANCE IMAGING; MAGNETISM; QUALITY ASSURANCE; QUALITY CONTROL; RESONANCE; SYSTEMATIC ERRORS; TISSUE; UROLOGY;

EID: 84879409527     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24459     Document Type: Article
Times cited : (97)

References (21)
  • 3
    • 77954077099 scopus 로고    scopus 로고
    • Treatment planning using MRI data: An analysis of the dose calculation accuracy for different treatment regions
    • Jonsson JH, Karlsson MG, Karlsson M, Nyholm T,. Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions. Radiat Oncol 2010; 5: 62-69.
    • (2010) Radiat Oncol , vol.5 , pp. 62-69
    • Jonsson, J.H.1    Karlsson, M.G.2    Karlsson, M.3    Nyholm, T.4
  • 4
    • 79952454508 scopus 로고    scopus 로고
    • MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning
    • Lambert J, Greer PB, Menk F, et al. MRI-guided prostate radiation therapy planning: investigation of dosimetric accuracy of MRI-based dose planning. Radiother Oncol 2011; 98: 330-334.
    • (2011) Radiother Oncol , vol.98 , pp. 330-334
    • Lambert, J.1    Greer, P.B.2    Menk, F.3
  • 5
    • 14644418420 scopus 로고    scopus 로고
    • Use and uncertainties of mutual information for computed tomography/magnetic resonance (CT/MR) registration post permanent implant of the prostate
    • Roberson P, McLaughlin P, Narayana V, Troyer S, Hixson GV, Kessler ML,. Use and uncertainties of mutual information for computed tomography/magnetic resonance (CT/MR) registration post permanent implant of the prostate. Med Phys 2005; 32: 473-482.
    • (2005) Med Phys , vol.32 , pp. 473-482
    • Roberson, P.1    McLaughlin, P.2    Narayana, V.3    Troyer, S.4    Hixson, G.V.5    Kessler, M.L.6
  • 6
    • 71049137342 scopus 로고    scopus 로고
    • Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments
    • Nyholm T, Nyberg M, Karlsson MG, Karlsson M,. Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments. Radiat Oncol 2009; 4: 54-62.
    • (2009) Radiat Oncol , vol.4 , pp. 54-62
    • Nyholm, T.1    Nyberg, M.2    Karlsson, M.G.3    Karlsson, M.4
  • 7
    • 0035101317 scopus 로고    scopus 로고
    • Aspects of MR image distortions in radiotherapy treatment planning
    • Fransson A, Andreo P, Pötter R,. Aspects of MR image distortions in radiotherapy treatment planning. Strahlenther Onkol 2001; 177: 59-73.
    • (2001) Strahlenther Onkol , vol.177 , pp. 59-73
    • Fransson, A.1    Andreo, P.2    Pötter, R.3
  • 9
    • 0037295469 scopus 로고    scopus 로고
    • Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration
    • Parker C, Damyanovich A, Haycocks T, Haider M, Bayley A, Catton CN,. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration. Radiother Oncol 2003; 66: 217-224.
    • (2003) Radiother Oncol , vol.66 , pp. 217-224
    • Parker, C.1    Damyanovich, A.2    Haycocks, T.3    Haider, M.4    Bayley, A.5    Catton, C.N.6
  • 11
    • 79954443670 scopus 로고    scopus 로고
    • Highly localized positive contrast of small paramagnetic objects using 3D center-out radial sampling with off-resonance reception
    • Seevinck PR, de Leeuw H, Bos C, Bakker CJG,. Highly localized positive contrast of small paramagnetic objects using 3D center-out radial sampling with off-resonance reception. Magn Reson Med 2011; 65: 146-156.
    • (2011) Magn Reson Med , vol.65 , pp. 146-156
    • Seevinck, P.R.1    De Leeuw, H.2    Bos, C.3    Bakker, C.J.G.4
  • 12
    • 0042092047 scopus 로고    scopus 로고
    • On the artifact of a subvoxel susceptibility deviation in spoiled gradient-echo imaging
    • Bos C, Viergever MA, Bakker CJ,. On the artifact of a subvoxel susceptibility deviation in spoiled gradient-echo imaging. Magn Reson Med 2003; 50: 400-404.
    • (2003) Magn Reson Med , vol.50 , pp. 400-404
    • Bos, C.1    Viergever, M.A.2    Bakker, C.J.3
  • 13
    • 79960491751 scopus 로고    scopus 로고
    • Assessing the image quality of pelvic MR images acquired with a flat couch for radiotherapy treatment planning
    • McJury M, O'Neill A, Lawson M, McGrath C, Grey A, Page W, O'Sullivan JM,. Assessing the image quality of pelvic MR images acquired with a flat couch for radiotherapy treatment planning. Br J Radiol 2011; 84: 750-755.
    • (2011) Br J Radiol , vol.84 , pp. 750-755
    • McJury, M.1    O'Neill, A.2    Lawson, M.3    McGrath, C.4    Grey, A.5    Page, W.6    O'Sullivan, J.M.7
  • 15
    • 84872042898 scopus 로고    scopus 로고
    • T1/T2*-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning
    • doi: 10.3109/0284186X.2012.692883.
    • Kapanen M, Tenhunen M,. T1/T2*-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning. Acta Oncol 2012. doi: 10.3109/0284186X.2012. 692883.
    • (2012) Acta Oncol
    • Kapanen, M.1    Tenhunen, M.2
  • 16
    • 34249331346 scopus 로고    scopus 로고
    • Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy: Creation of digitally reconstructed radiographs
    • Chen L, Nguyen TB, Jones E, Chen Z, Luo W, Wang L, Price RA, Pollack A, Ma C,. Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy: creation of digitally reconstructed radiographs. Int J Radiat Oncol Biol Phys 2007; 68: 903-911.
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 903-911
    • Chen, L.1    Nguyen, T.B.2    Jones, E.3    Chen, Z.4    Luo, W.5    Wang, L.6    Price, R.A.7    Pollack, A.8    Ma, C.9
  • 18
    • 84859849568 scopus 로고    scopus 로고
    • An atlas-based electron density mapping method for magnetic resonance imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy
    • Dowling JA, Lambert J, Parker J, Salvado O, Fripp J, Capp A, Wratten C, Denham JW, Greer PB,. An atlas-based electron density mapping method for magnetic resonance imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy. Int J Radiat Oncol Biol Phys 2012; 83: e5-e11.
    • (2012) Int J Radiat Oncol Biol Phys , vol.83
    • Dowling, J.A.1    Lambert, J.2    Parker, J.3    Salvado, O.4    Fripp, J.5    Capp, A.6    Wratten, C.7    Denham, J.W.8    Greer, P.B.9
  • 19
    • 0142057571 scopus 로고    scopus 로고
    • Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: Report of the AAPM radiation therapy committee task group no. 66
    • Mutic S, Palta JR, Butker EK, Das IJ, Huq MS, Dick Loo LN, Salter BJ, McCollough CH, Van Dyk JV,. Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM radiation therapy committee task group no. 66. Med Phys 2003; 30: 2762-2792.
    • (2003) Med Phys , vol.30 , pp. 2762-2792
    • Mutic, S.1    Palta, J.R.2    Butker, E.K.3    Das, I.J.4    Huq, M.S.5    Dick Loo, L.N.6    Salter, B.J.7    McCollough, C.H.8    Van Dyk, J.V.9
  • 20
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • Schenck JF,. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 1996; 23: 815-850.
    • (1996) Med Phys , vol.23 , pp. 815-850
    • Schenck, J.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.