-
2
-
-
84873882859
-
Animal models in cardiovascular MRI research: value and limitations
-
French BA,. Animal models in cardiovascular MRI research: value and limitations. Curr Cardiovasc Imaging Rep 2012; 5: 99-108.
-
(2012)
Curr Cardiovasc Imaging Rep
, vol.5
, pp. 99-108
-
-
French, B.A.1
-
3
-
-
0021326299
-
High resolution proton NMR studies of perfused rat hearts
-
Ugurbil K, Petein M, Maidan R, Michurski S, Cohn JN, From AH,. High resolution proton NMR studies of perfused rat hearts. FEBS Lett 1984; 167: 73-78.
-
(1984)
FEBS Lett
, vol.167
, pp. 73-78
-
-
Ugurbil, K.1
Petein, M.2
Maidan, R.3
Michurski, S.4
Cohn, J.N.5
From, A.H.6
-
4
-
-
0034108741
-
Reduced 1H-NMR visibility of creatine in isolated rat hearts
-
Schneider J, Fekete E, Weisser A, Neubauer S, Von Kienlin M,. Reduced 1H-NMR visibility of creatine in isolated rat hearts. Magn Reson Med 2000; 43: 497-502.
-
(2000)
Magn Reson Med
, vol.43
, pp. 497-502
-
-
Schneider, J.1
Fekete, E.2
Weisser, A.3
Neubauer, S.4
Von Kienlin, M.5
-
5
-
-
0017345787
-
Phosphorus nuclear magnetic resonance of perfused working rat hearts
-
Jacobus WE, Taylor GJ IV, Hollis DP, Nunnally RL,. Phosphorus nuclear magnetic resonance of perfused working rat hearts. Nature 1977; 265: 756-758.
-
(1977)
Nature
, vol.265
, pp. 756-758
-
-
Jacobus, W.E.1
Taylor, G.J.2
Hollis, D.P.3
Nunnally, R.L.4
-
6
-
-
0036073201
-
Mitochondrial creatine kinase is critically necessary for normal myocardial high-energy phosphate metabolism
-
Spindler M, Niebler R, Remkes H, Horn M, Lanz T, Neubauer S,. Mitochondrial creatine kinase is critically necessary for normal myocardial high-energy phosphate metabolism. Am J Physiol Heart Circ Physiol 2002; 283: H680-H687.
-
(2002)
Am J Physiol Heart Circ Physiol
, vol.283
, pp. H680-H687
-
-
Spindler, M.1
Niebler, R.2
Remkes, H.3
Horn, M.4
Lanz, T.5
Neubauer, S.6
-
7
-
-
0025130474
-
Influence of global ischemia on intracellular sodium in the perfused rat heart
-
Malloy CR, Buster DC, Castro MMCA, Geraldes CFGC, Jeffrey FMH, Sherry AD,. Influence of global ischemia on intracellular sodium in the perfused rat heart. Magn Reson Med 1990; 15: 33-44.
-
(1990)
Magn Reson Med
, vol.15
, pp. 33-44
-
-
Malloy, C.R.1
Buster, D.C.2
Castro, M.3
Geraldes, C.4
Jeffrey, F.M.H.5
Sherry, A.D.6
-
8
-
-
0019457262
-
Studies of metabolism in the isolated, perfused rat heart using 13C NMR
-
Bailey IA, Gadian DG, Matthews PM, Radda GK, Seeley PJ,. Studies of metabolism in the isolated, perfused rat heart using 13C NMR. FEBS Lett 1981; 123: 315-318.
-
(1981)
FEBS Lett
, vol.123
, pp. 315-318
-
-
Bailey, I.A.1
Gadian, D.G.2
Matthews, P.M.3
Radda, G.K.4
Seeley, P.J.5
-
9
-
-
0024476759
-
87Rb NMR studies of the perfused rat heart
-
Allis JL, Snaith CD, Seymour AL, Radda GK,. 87Rb NMR studies of the perfused rat heart. FEBS Lett 1989; 242: 215-217.
-
(1989)
FEBS Lett
, vol.242
, pp. 215-217
-
-
Allis, J.L.1
Snaith, C.D.2
Seymour, A.L.3
Radda, G.K.4
-
10
-
-
0033617112
-
Physiological basis for potassium (39K) magnetic resonance imaging of the heart
-
Fieno DS, Kim RJ, Rehwald WG, Judd RM,. Physiological basis for potassium (39K) magnetic resonance imaging of the heart. Circ Res 1999; 84: 913-920.
-
(1999)
Circ Res
, vol.84
, pp. 913-920
-
-
Fieno, D.S.1
Kim, R.J.2
Rehwald, W.G.3
Judd, R.M.4
-
11
-
-
0025269066
-
First-pass cardiac perfusion: evaluation with ultrafast MR imaging
-
Atkinson DJ, Burstein D, Edelman RR,. First-pass cardiac perfusion: evaluation with ultrafast MR imaging. Radiology 1990; 174: 757-762.
-
(1990)
Radiology
, vol.174
, pp. 757-762
-
-
Atkinson, D.J.1
Burstein, D.2
Edelman, R.R.3
-
12
-
-
0026151237
-
MR imaging of coronary artery flow in isolated and in vivo hearts
-
Burstein D,. MR imaging of coronary artery flow in isolated and in vivo hearts. J Magn Reson Imaging 1991; 1: 337-346.
-
(1991)
J Magn Reson Imaging
, vol.1
, pp. 337-346
-
-
Burstein, D.1
-
13
-
-
0027283766
-
Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial water
-
Williams DS, Grandis DJ, Zhang W, Koretsky AP,. Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial water. Magn Reson Med 1993; 30: 361-365.
-
(1993)
Magn Reson Med
, vol.30
, pp. 361-365
-
-
Williams, D.S.1
Grandis, D.J.2
Zhang, W.3
Koretsky, A.P.4
-
14
-
-
0028325083
-
Anisotropy of water diffusion in the myocardium of the rat
-
Garrido L, Wedeen VJ, Kwong KK, Spencer UM, Kantor HL,. Anisotropy of water diffusion in the myocardium of the rat. Circ Res 1994; 74: 789-793.
-
(1994)
Circ Res
, vol.74
, pp. 789-793
-
-
Garrido, L.1
Wedeen, V.J.2
Kwong, K.K.3
Spencer, U.M.4
Kantor, H.L.5
-
16
-
-
27144507337
-
Regional ventricular wall thickening reflects changes in cardiac fiber and sheet structure during contraction: quantification with diffusion tensor MRI
-
Chen J, Liu W, Zhang H, Lacy L, Yang X, Song S, Wickline SA, Yu X,. Regional ventricular wall thickening reflects changes in cardiac fiber and sheet structure during contraction: quantification with diffusion tensor MRI. Am J Physiol Heart Circ Physiol 2005; 289: H1898-H1907.
-
(2005)
Am J Physiol Heart Circ Physiol
, vol.289
, pp. H1898-H1907
-
-
Chen, J.1
Liu, W.2
Zhang, H.3
Lacy, L.4
Yang, X.5
Song, S.6
Wickline, S.A.7
Yu, X.8
-
17
-
-
0035007494
-
Two-component diffusion tensor MRI of isolated perfused hearts
-
Hsu EW, Buckley DL, Bui JD, Blackband SJ, Forder JR,. Two-component diffusion tensor MRI of isolated perfused hearts. Magn Reson Med 2001; 45: 1039-1045.
-
(2001)
Magn Reson Med
, vol.45
, pp. 1039-1045
-
-
Hsu, E.W.1
Buckley, D.L.2
Bui, J.D.3
Blackband, S.J.4
Forder, J.R.5
-
18
-
-
84868138467
-
Histo-anatomical structure of the living isolated rat heart in two contraction states assessed by diffusion tensor MRI
-
Hales PW, Schneider JE, Burton RAB, Wright BJ, Bollensdorff C, Kohl P,. Histo-anatomical structure of the living isolated rat heart in two contraction states assessed by diffusion tensor MRI. Prog Biophys Mol Biol 2012; 110: 319-330.
-
(2012)
Prog Biophys Mol Biol
, vol.110
, pp. 319-330
-
-
Hales, P.W.1
Schneider, J.E.2
Burton, R.A.B.3
Wright, B.J.4
Bollensdorff, C.5
Kohl, P.6
-
19
-
-
84881190089
-
In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches
-
Nielles-Vallespin S, Mekkaoui C, et al., In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches. Magn Reson Med 2013; 70: 454-465.
-
(2013)
Magn Reson Med
, vol.70
, pp. 454-465
-
-
Nielles-Vallespin, S.1
Mekkaoui, C.2
-
20
-
-
84923126507
-
Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging
-
Lau AZ, Tunnicliffe EM, Frost R, Koopmans PJ, Tyler DJ, Robson MD,. Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging. Magn Reson Med 2014. doi: 10.1002/mrm.25200.
-
(2014)
Magn Reson Med
-
-
Lau, A.Z.1
Tunnicliffe, E.M.2
Frost, R.3
Koopmans, P.J.4
Tyler, D.J.5
Robson, M.D.6
-
21
-
-
33846834120
-
Diffusion imaging of the in vivo heart using spin echoes-considerations on bulk motion sensitivity
-
Gamper U, Boesiger P, Kozerke S,. Diffusion imaging of the in vivo heart using spin echoes-considerations on bulk motion sensitivity. Magn Reson Med 2007; 57: 331-337.
-
(2007)
Magn Reson Med
, vol.57
, pp. 331-337
-
-
Gamper, U.1
Boesiger, P.2
Kozerke, S.3
-
22
-
-
84907954026
-
In vivo three-dimensional high resolution cardiac diffusion-weighted MRI: a motion compensated diffusion-prepared balanced steady-state free precession approach
-
Nguyen C, Fan Z, Sharif B, He Y, Dharmakumar R, Berman DS, Li D,. In vivo three-dimensional high resolution cardiac diffusion-weighted MRI: a motion compensated diffusion-prepared balanced steady-state free precession approach. Magn Reson Med 2013. doi: 10.1002/mrm.25038.
-
(2013)
Magn Reson Med
-
-
Nguyen, C.1
Fan, Z.2
Sharif, B.3
He, Y.4
Dharmakumar, R.5
Berman, D.S.6
Li, D.7
-
23
-
-
84899942889
-
Microstructural impact of ischemia and bone marrow-derived cell therapy revealed with diffusion tensor magnetic resonance imaging tractography of the heart in vivo
-
Sosnovik DE, Mekkaoui C, Huang S, et al., Microstructural impact of ischemia and bone marrow-derived cell therapy revealed with diffusion tensor magnetic resonance imaging tractography of the heart in vivo. Circulation 2014; 129: 1731-1741.
-
(2014)
Circulation
, vol.129
, pp. 1731-1741
-
-
Sosnovik, D.E.1
Mekkaoui, C.2
Huang, S.3
-
24
-
-
33748498239
-
Diffusion tensor magnetic resonance imaging mapping the fiber architecture remodeling in human myocardium after infarction: correlation with viability and wall motion
-
Wu M, Tseng WI, Su MM, Liu C, Chiou K, Wedeen VJ, Reese TG, Yang C,. Diffusion tensor magnetic resonance imaging mapping the fiber architecture remodeling in human myocardium after infarction: correlation with viability and wall motion. Circulation 2006; 114: 1036-1045.
-
(2006)
Circulation
, vol.114
, pp. 1036-1045
-
-
Wu, M.1
Tseng, W.I.2
Su, M.M.3
Liu, C.4
Chiou, K.5
Wedeen, V.J.6
Reese, T.G.7
Yang, C.8
-
25
-
-
84871400496
-
Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy
-
McGill L, Ismail TF, Nielles-Vallespin S, et al., Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson 2012; 14: 86.
-
(2012)
J Cardiovasc Magn Reson
, vol.14
, pp. 86
-
-
McGill, L.1
Ismail, T.F.2
Nielles-Vallespin, S.3
-
26
-
-
84901379570
-
Intercentre reproducibility of cardiac apparent diffusion coefficient and fractional anisotropy in healthy volunteers
-
Tunnicliffe EM, Scott AD, Ferreira P, Ariga R, McGill L, Nielles-Vallespin S, Neubauer S, Pennell DJ, Robson MD, Firmin DN,. Intercentre reproducibility of cardiac apparent diffusion coefficient and fractional anisotropy in healthy volunteers. J Cardiovasc Magn Reson 2014; 16: 31.
-
(2014)
J Cardiovasc Magn Reson
, vol.16
, pp. 31
-
-
Tunnicliffe, E.M.1
Scott, A.D.2
Ferreira, P.3
Ariga, R.4
McGill, L.5
Nielles-Vallespin, S.6
Neubauer, S.7
Pennell, D.J.8
Robson, M.D.9
Firmin, D.N.10
-
27
-
-
79958844599
-
Technical note: DTI measurements of fractional anisotropy and mean diffusivity at 1.5 T: comparison of two radiofrequency head coils with different functional designs and sensitivities
-
Giannelli M, Belmonte G, Toschi N, Pesaresi I, Ghedin P, Claudio Traino A, Bartolozzi C, Cosottini M,. Technical note: DTI measurements of fractional anisotropy and mean diffusivity at 1.5 T: comparison of two radiofrequency head coils with different functional designs and sensitivities. Med Phys 2011; 38: 3205-3211.
-
(2011)
Med Phys
, vol.38
, pp. 3205-3211
-
-
Giannelli, M.1
Belmonte, G.2
Toschi, N.3
Pesaresi, I.4
Ghedin, P.5
Claudio Traino, A.6
Bartolozzi, C.7
Cosottini, M.8
-
28
-
-
46549092488
-
An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
-
Hayes CE, Edelstein WA, Schenck JF, Mueller OM, Eash M,. An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T. J Magn Reson (1969) 1985; 63: 622-628.
-
(1985)
J Magn Reson (1969)
, vol.63
, pp. 622-628
-
-
Hayes, C.E.1
Edelstein, W.A.2
Schenck, J.F.3
Mueller, O.M.4
Eash, M.5
-
29
-
-
80051594891
-
2 and left-ventricular histo-architecture in the fixed and embedded rat heart
-
2 and left-ventricular histo-architecture in the fixed and embedded rat heart. NMR Biomed 2011; 24: 836-843.
-
(2011)
NMR Biomed
, vol.24
, pp. 836-843
-
-
Hales, P.W.1
Burton, R.A.2
Bollensdorff, C.3
Mason, F.4
Bishop, M.5
Gavaghan, D.6
Kohl, P.7
Schneider, J.E.8
-
30
-
-
0031836558
-
Versatile frequency domain fitting using time domain models and prior knowledge
-
Slotboom J, Boesch C, Kreis R,. Versatile frequency domain fitting using time domain models and prior knowledge. Magn Reson Med 1998; 39: 899-911.
-
(1998)
Magn Reson Med
, vol.39
, pp. 899-911
-
-
Slotboom, J.1
Boesch, C.2
Kreis, R.3
-
31
-
-
0028398052
-
Estimation of the effective self-diffusion tensor from the NMR spin echo
-
Basser PJ, Mattiello J, Lebihan D,. Estimation of the effective self-diffusion tensor from the NMR spin echo. J Magn Reson Ser B 1994; 103: 247-254.
-
(1994)
J Magn Reson Ser B
, vol.103
, pp. 247-254
-
-
Basser, P.J.1
Mattiello, J.2
Lebihan, D.3
-
32
-
-
0041702764
-
Parametric and non-parametric statistical analysis of DT-MRI data
-
Pajevic S, Basser PJ,. Parametric and non-parametric statistical analysis of DT-MRI data. J Magn Reson 2003; 161: 1-14.
-
(2003)
J Magn Reson
, vol.161
, pp. 1-14
-
-
Pajevic, S.1
Basser, P.J.2
-
33
-
-
0037227848
-
Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI
-
Jones DK,. Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI. Magn Reson Med 2003; 49: 7-12.
-
(2003)
Magn Reson Med
, vol.49
, pp. 7-12
-
-
Jones, D.K.1
-
34
-
-
34249719407
-
Radio frequency coil technology for small-animal MRI
-
Doty FD, Entzminger G, Kulkarni J, Pamarthy K, Staab JP,. Radio frequency coil technology for small-animal MRI. NMR Biomed 2007; 20: 304-325.
-
(2007)
NMR Biomed
, vol.20
, pp. 304-325
-
-
Doty, F.D.1
Entzminger, G.2
Kulkarni, J.3
Pamarthy, K.4
Staab, J.P.5
-
35
-
-
77953940488
-
A high-throughput eight-channel probe head for murine MRI at 9.4 T
-
Lanz T, Müller M, Barnes H, Neubauer S, Schneider JE,. A high-throughput eight-channel probe head for murine MRI at 9.4 T. Magn Reson Med 2010; 64: 80-87.
-
(2010)
Magn Reson Med
, vol.64
, pp. 80-87
-
-
Lanz, T.1
Müller, M.2
Barnes, H.3
Neubauer, S.4
Schneider, J.E.5
-
36
-
-
33749171698
-
Just how much data need to be collected for reliable bootstrap DT-MRI?
-
O'Gorman RL, Jones DK,. Just how much data need to be collected for reliable bootstrap DT-MRI? Magn Reson Med 2006; 56: 884-890.
-
(2006)
Magn Reson Med
, vol.56
, pp. 884-890
-
-
O'Gorman, R.L.1
Jones, D.K.2
-
37
-
-
0031732550
-
A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging
-
Bastin ME, Armitage PA, Marshall I,. A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging. Magn Reson Imaging 1998; 16: 773-785.
-
(1998)
Magn Reson Imaging
, vol.16
, pp. 773-785
-
-
Bastin, M.E.1
Armitage, P.A.2
Marshall, I.3
-
38
-
-
0035178887
-
Theoretical analysis of the effects of noise on diffusion tensor imaging
-
Anderson AW,. Theoretical analysis of the effects of noise on diffusion tensor imaging. Magn Reson Med 2001; 46: 1174-1188.
-
(2001)
Magn Reson Med
, vol.46
, pp. 1174-1188
-
-
Anderson, A.W.1
-
39
-
-
35248816901
-
Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T
-
Farrell JAD, Landman BA, Jones CK, Smith SA, Prince JL, Van Zijl PCM, Mori S,. Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T. J Magn Reson Imaging 2007; 26: 756-767.
-
(2007)
J Magn Reson Imaging
, vol.26
, pp. 756-767
-
-
Farrell, J.A.D.1
Landman, B.A.2
Jones, C.K.3
Smith, S.A.4
Prince, J.L.5
Van Zijl, P.C.M.6
Mori, S.7
-
40
-
-
57149090087
-
Characterizing fiber directional uncertainty in diffusion tensor MRI
-
Jeong H, Anderson AW,. Characterizing fiber directional uncertainty in diffusion tensor MRI. Magn Reson Med 2008; 60: 1408-1421.
-
(2008)
Magn Reson Med
, vol.60
, pp. 1408-1421
-
-
Jeong, H.1
Anderson, A.W.2
-
41
-
-
79958248349
-
Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla
-
Polders DL, Leemans A, Hendrikse J, Donahue MJ, Luijten PR, Hoogduin JM,. Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla. J Magn Reson Imaging 2011; 33: 1456-1463.
-
(2011)
J Magn Reson Imaging
, vol.33
, pp. 1456-1463
-
-
Polders, D.L.1
Leemans, A.2
Hendrikse, J.3
Donahue, M.J.4
Luijten, P.R.5
Hoogduin, J.M.6
-
42
-
-
79959211395
-
DTI at 7 and 3 T: systematic comparison of SNR and its influence on quantitative metrics
-
Choi S, Cunningham DT, Aguila F, Corrigan JD, Bogner J, Mysiw WJ, Knopp MV, Schmalbrock P,. DTI at 7 and 3 T: systematic comparison of SNR and its influence on quantitative metrics. Magn Reson Imaging 2011; 29: 739-751.
-
(2011)
Magn Reson Imaging
, vol.29
, pp. 739-751
-
-
Choi, S.1
Cunningham, D.T.2
Aguila, F.3
Corrigan, J.D.4
Bogner, J.5
Mysiw, W.J.6
Knopp, M.V.7
Schmalbrock, P.8
-
43
-
-
53549121202
-
Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations
-
Damon BM,. Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations. Magn Reson Med 2008; 60: 934-944.
-
(2008)
Magn Reson Med
, vol.60
, pp. 934-944
-
-
Damon, B.M.1
-
44
-
-
84908625685
-
Optimizing accuracy and precision in high resolution diffusion tensor imaging of the ex vivo rat heart
-
Stockholm, Sweden
-
Hales PW, Burton R, Bollensdorff C, Schneider JE,. Optimizing accuracy and precision in high resolution diffusion tensor imaging of the ex vivo rat heart. In Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010. p. 1521.
-
(2010)
Proceedings of the 18th Annual Meeting of ISMRM
, pp. 1521
-
-
Hales, P.W.1
Burton, R.2
Bollensdorff, C.3
Schneider, J.E.4
|