메뉴 건너뛰기




Volumn 16, Issue 1, 2014, Pages

Optimized saturation recovery protocols for T1-mapping in the heart: influence of sampling strategies on precision

Author keywords

Myocardial fibrosis; Precision; Random error; SASHA; Saturation recovery; T1 mapping

Indexed keywords

ACCURACY; ARTICLE; CARDIOVASCULAR PARAMETERS; CARDIOVASCULAR SYSTEM EXAMINATION; CLINICAL PROTOCOL; CONTROLLED STUDY; FIXED SATURATION DELAY; HEART BEAT; HUMAN; HUMAN EXPERIMENT; IN VIVO STUDY; INTERMETHOD COMPARISON; MATHEMATICAL ANALYSIS; MATHEMATICAL MODEL; MONTE CARLO METHOD; MYOCARDIAL T1 MAPPING; PRIORITY JOURNAL; PROCESS DEVELOPMENT; PROCESS OPTIMIZATION; VALIDATION STUDY; ALGORITHM; BIOLOGICAL MODEL; CARDIAC MUSCLE; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER SIMULATION; DEVICES; FIBROSIS; HEART DISEASES; IMAGING PHANTOM; MATHEMATICAL COMPUTING; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; PREDICTIVE VALUE; PROCEDURES; REPRODUCIBILITY;

EID: 84929163526     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1186/s12968-014-0055-3     Document Type: Article
Times cited : (42)

References (20)
  • 2
    • 84894378341 scopus 로고    scopus 로고
    • Review of T1 mapping methods: comparative effectiveness including reproducibility issues
    • Higgins DM, Moon JC. Review of T1 mapping methods: comparative effectiveness including reproducibility issues. Curr Cardiovasc Imaging Rep. 2014; 7:9252.
    • (2014) Curr Cardiovasc Imaging Rep , vol.7 , pp. 9252
    • Higgins, D.M.1    Moon, J.C.2
  • 3
    • 84891503345 scopus 로고    scopus 로고
    • T1-mapping in the heart: accuracy and precision
    • 24387626 3927683
    • Kellman P, Hansen MS. T1-mapping in the heart: accuracy and precision. J Cardiovasc Magn Reson. 2014; 16:2.
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. 2
    • Kellman, P.1    Hansen, M.S.2
  • 6
    • 84883257373 scopus 로고    scopus 로고
    • T1 measurements in the human myocardium: the effects of magnetization transfer on the SASHA and MOLLI sequences
    • Robson MD, Piechnik SK, Tunnicliffe EM, Neubauer S. T1 measurements in the human myocardium: the effects of magnetization transfer on the SASHA and MOLLI sequences. Magn Reson Med. 2013; 670:664-70.
    • (2013) Magn Reson Med , vol.670 , pp. 664-670
    • Robson, M.D.1    Piechnik, S.K.2    Tunnicliffe, E.M.3    Neubauer, S.4
  • 8
    • 0032963505 scopus 로고    scopus 로고
    • Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T∗2 and T1 measurements
    • 1:CAS:528:DyaK1MXjt1Wms78%3D 10332843
    • Wacker CM, Bock M, Hartlep AW, Beck G, van Kaick G, Ertl G, Bauer WR, Schad LR. Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T∗2 and T1 measurements. Magn Reson Med. 1999; 41:686-95.
    • (1999) Magn Reson Med , vol.41 , pp. 686-695
    • Wacker, C.M.1    Bock, M.2    Hartlep, A.W.3    Beck, G.4    Van Kaick, G.5    Ertl, G.6    Bauer, W.R.7    Schad, L.R.8
  • 9
    • 84946411102 scopus 로고    scopus 로고
    • Breath-held myocardial T1 mapping using multiple single-point saturation recovery
    • Slavin GS. Breath-held myocardial T1 mapping using multiple single-point saturation recovery. Proc ISMRM. 2012; 20:1244.
    • (2012) Proc ISMRM , vol.20 , pp. 1244
    • Slavin, G.S.1
  • 10
    • 84904206815 scopus 로고    scopus 로고
    • Comparing the accuracy and precision of SMART1Map, SASHA and MOLLI
    • Stainsby JA, Slavin GS. Comparing the accuracy and precision of SMART1Map, SASHA and MOLLI. J Cardiovasc Magn Reson. 2014; 16 Suppl 1: 11.
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. 11
    • Stainsby, J.A.1    Slavin, G.S.2
  • 11
    • 84879082743 scopus 로고    scopus 로고
    • T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision
    • 23800276 3702513
    • Kellman P, Arai AE, Xue H. T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision. J Cardiovasc Magn Reson. 2013; 15:56.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 56
    • Kellman, P.1    Arai, A.E.2    Xue, H.3
  • 12
    • 84946399810 scopus 로고    scopus 로고
    • Selection of sampling points for saturation recovery based myocardial T1 mapping
    • 4044132
    • Akcakaya M, Weingartner S, Manning WJ, Nezafat R. Selection of sampling points for saturation recovery based myocardial T1 mapping. J Cardiovasc Magn Reson. 2014; 16 Suppl 1: W32.
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. W32
    • Akcakaya, M.1    Weingartner, S.2    Manning, W.J.3    Nezafat, R.4
  • 13
    • 84928027517 scopus 로고    scopus 로고
    • On the selection of sampling points for myocardial T 1 mapping
    • n/a-n/a
    • Akçakaya M, Weingärtner S, Roujol S, Nezafat R. On the selection of sampling points for myocardial T 1 mapping. Magn Reson Med 2014; 00:n/a-n/a. doi:10.1002/mrm.25285.
    • (2014) Magn Reson Med
    • Akçakaya, M.1    Weingärtner, S.2    Roujol, S.3    Nezafat, R.4
  • 14
    • 27644527486 scopus 로고    scopus 로고
    • Image reconstruction in SNR units: a general method for SNR measurement
    • 16261576 2570032
    • Kellman P, McVeigh ER. Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med. 2005; 54:1439-47.
    • (2005) Magn Reson Med , vol.54 , pp. 1439-1447
    • Kellman, P.1    McVeigh, E.R.2
  • 15
    • 34547764446 scopus 로고    scopus 로고
    • Erratum to Kellman P, McVeigh ER. Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med. 2005;54:1439-1447
    • Kellman P. Erratum to Kellman P, McVeigh ER. Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med. 2005;54:1439-1447. Magn Reson Med. 2007; 58:211-2.
    • (2007) Magn Reson Med , vol.58 , pp. 211-212
    • Kellman, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.