메뉴 건너뛰기




Volumn 73, Issue 5, 2015, Pages 1741-1753

On the selection of sampling points for myocardial T1 mapping

Author keywords

Cram r Rao bound; Fisher information; myocardial T1 mapping; parameter estimation; precision; sampling points; tissue characterization

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; FISHER INFORMATION MATRIX; MAPPING; NUMERICAL METHODS; NUMERICAL MODELS; PARAMETER ESTIMATION; PHANTOMS; SIGNAL TO NOISE RATIO;

EID: 84928027517     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.25285     Document Type: Article
Times cited : (32)

References (36)
  • 1
    • 84953656233 scopus 로고
    • A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?
    • Bottomley PA, Hardy CJ, Argersinger RE, Allen-Moore G,. A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic? Med Phys 1987; 14: 1-37.
    • (1987) Med Phys , vol.14 , pp. 1-37
    • Bottomley, P.A.1    Hardy, C.J.2    Argersinger, R.E.3    Allen-Moore, G.4
  • 2
    • 49049099802 scopus 로고    scopus 로고
    • Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
    • Warntjes JB, Leinhard OD, West J, Lundberg P,. Rapid magnetic resonance quantification on the brain: optimization for clinical usage. Magn Reson Med 2008; 60: 320-329.
    • (2008) Magn Reson Med , vol.60 , pp. 320-329
    • Warntjes, J.B.1    Leinhard, O.D.2    West, J.3    Lundberg, P.4
  • 4
    • 0026543066 scopus 로고
    • Detection of bone marrow abnormalities in patients with Hodgkin's disease by T1 mapping of MR images of lumbar vertebral bone marrow
    • Smith SR, Roberts N, Percy DF, Edwards RH,. Detection of bone marrow abnormalities in patients with Hodgkin's disease by T1 mapping of MR images of lumbar vertebral bone marrow. Br J Cancer 1992; 65: 246-251.
    • (1992) Br J Cancer , vol.65 , pp. 246-251
    • Smith, S.R.1    Roberts, N.2    Percy, D.F.3    Edwards, R.H.4
  • 5
    • 84885015454 scopus 로고    scopus 로고
    • Quantitative T2 mapping of recurrent glioblastoma under bevacizumab improves monitoring for non-enhancing tumor progression and predicts overall survival
    • Hattingen E, Jurcoane A, Daneshvar K, Pilatus U, Mittelbronn M, Steinbach JP, Bahr O,. Quantitative T2 mapping of recurrent glioblastoma under bevacizumab improves monitoring for non-enhancing tumor progression and predicts overall survival. Neuro Oncol 2013; 15: 1395-1404.
    • (2013) Neuro Oncol , vol.15 , pp. 1395-1404
    • Hattingen, E.1    Jurcoane, A.2    Daneshvar, K.3    Pilatus, U.4    Mittelbronn, M.5    Steinbach, J.P.6    Bahr, O.7
  • 6
    • 79951642225 scopus 로고    scopus 로고
    • Assessment of myocardial fibrosis with cardiovascular magnetic resonance
    • Mewton N, Liu CY, Croisille P, Bluemke D, Lima JA,. Assessment of myocardial fibrosis with cardiovascular magnetic resonance. J Am Coll Cardiol 2011; 57: 891-903.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 891-903
    • Mewton, N.1    Liu, C.Y.2    Croisille, P.3    Bluemke, D.4    Lima, J.A.5
  • 7
    • 70350437540 scopus 로고    scopus 로고
    • The future of cardiovascular imaging in the diagnosis and management of heart failure, part 1: Tasks and tools
    • Marwick TH, Schwaiger M,. The future of cardiovascular imaging in the diagnosis and management of heart failure, part 1: tasks and tools. Circ Cardiovasc Imaging 2008; 1: 58-69.
    • (2008) Circ Cardiovasc Imaging , vol.1 , pp. 58-69
    • Marwick, T.H.1    Schwaiger, M.2
  • 11
    • 84894459536 scopus 로고    scopus 로고
    • Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability
    • Weingartner S, Akcakaya M, Basha T, Kissinger KV, Goddu B, Berg S, Manning WJ, Nezafat R,. Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability. Magn Reson Med 2014; 71: 1024-1034.
    • (2014) Magn Reson Med , vol.71 , pp. 1024-1034
    • Weingartner, S.1    Akcakaya, M.2    Basha, T.3    Kissinger, K.V.4    Goddu, B.5    Berg, S.6    Manning, W.J.7    Nezafat, R.8
  • 12
    • 84891503345 scopus 로고    scopus 로고
    • T1-mapping in the heart: Accuracy and precision
    • Kellman P, Hansen MS,. T1-mapping in the heart: accuracy and precision. J Cardiovasc Magn Reson 2014; 16: 2.
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. 2
    • Kellman, P.1    Hansen, M.S.2
  • 13
    • 0033911228 scopus 로고    scopus 로고
    • Magnetic resonance imaging in patients with cardiomyopathies: When and why
    • Schulz-Menger J, Friedrich MG,. Magnetic resonance imaging in patients with cardiomyopathies: when and why. Herz 2000; 25: 384-391.
    • (2000) Herz , vol.25 , pp. 384-391
    • Schulz-Menger, J.1    Friedrich, M.G.2
  • 14
    • 0033005256 scopus 로고    scopus 로고
    • Measurement of the distribution volume of gadopentetate dimeglumine at echo-planar MR imaging to quantify myocardial infarction: Comparison with 99mTc-DTPA autoradiography in rats
    • Arheden H, Saeed M, Higgins CB, Gao DW, Bremerich J, Wyttenbach R, Dae MW, Wendland MF,. Measurement of the distribution volume of gadopentetate dimeglumine at echo-planar MR imaging to quantify myocardial infarction: comparison with 99mTc-DTPA autoradiography in rats. Radiology 1999; 211: 698-708.
    • (1999) Radiology , vol.211 , pp. 698-708
    • Arheden, H.1    Saeed, M.2    Higgins, C.B.3    Gao, D.W.4    Bremerich, J.5    Wyttenbach, R.6    Dae, M.W.7    Wendland, M.F.8
  • 15
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    • Deoni SC, Rutt BK, Peters TM,. Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003; 49: 515-526.
    • (2003) Magn Reson Med , vol.49 , pp. 515-526
    • Deoni, S.C.1    Rutt, B.K.2    Peters, T.M.3
  • 16
    • 0030183444 scopus 로고    scopus 로고
    • Comparison of conventional single echo and multi-echo sequences with a fast spin-echo sequence for quantitative T2 mapping: Application to the prostate
    • Liney GP, Knowles AJ, Manton DJ, Turnbull LW, Blackband SJ, Horsman A,. Comparison of conventional single echo and multi-echo sequences with a fast spin-echo sequence for quantitative T2 mapping: application to the prostate. J Magn Reson Imaging 1996; 6: 603-607.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 603-607
    • Liney, G.P.1    Knowles, A.J.2    Manton, D.J.3    Turnbull, L.W.4    Blackband, S.J.5    Horsman, A.6
  • 17
    • 0014732355 scopus 로고
    • Time saving in measurement of NMR and EPR relaxation times
    • Look DC, Locker DR,. Time saving in measurement of NMR and EPR relaxation times. Rev Sci Instrum 1970; 41: 250-251.
    • (1970) Rev Sci Instrum , vol.41 , pp. 250-251
    • Look, D.C.1    Locker, D.R.2
  • 19
    • 0035091066 scopus 로고    scopus 로고
    • Rapid T(1) mapping using multislice echo planar imaging
    • Clare S, Jezzard P,. Rapid T(1) mapping using multislice echo planar imaging. Magn Reson Med 2001; 45: 630-634.
    • (2001) Magn Reson Med , vol.45 , pp. 630-634
    • Clare, S.1    Jezzard, P.2
  • 20
    • 84879082743 scopus 로고    scopus 로고
    • T1 and extracellular volume mapping in the heart: Estimation of error maps and the influence of noise on precision
    • Kellman P, Arai AE, Xue H,. T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision. J Cardiovasc Magn Reson 2013; 15: 56.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 56
    • Kellman, P.1    Arai, A.E.2    Xue, H.3
  • 22
    • 0242353954 scopus 로고    scopus 로고
    • Optimization of diffusion measurements using Cramer-Rao lower bound theory and its application to articular cartilage
    • Brihuega-Moreno O, Heese FP, Hall LD,. Optimization of diffusion measurements using Cramer-Rao lower bound theory and its application to articular cartilage. Magn Reson Med 2003; 50: 1069-1076.
    • (2003) Magn Reson Med , vol.50 , pp. 1069-1076
    • Brihuega-Moreno, O.1    Heese, F.P.2    Hall, L.D.3
  • 24
    • 44949280265 scopus 로고
    • Very rapid simultaneous measurement of nuclear magnetic resonance spin-lattice relaxation time and spin-spin relaxation time
    • Sezginer A, Kleinberg RL, Fukuhara M, Latour LL,. Very rapid simultaneous measurement of nuclear magnetic resonance spin-lattice relaxation time and spin-spin relaxation time. J Magn Reson 1991; 92: 504-527.
    • (1991) J Magn Reson , vol.92 , pp. 504-527
    • Sezginer, A.1    Kleinberg, R.L.2    Fukuhara, M.3    Latour, L.L.4
  • 25
    • 0002442431 scopus 로고    scopus 로고
    • Optimal sampling strategies for the measurement of spin-spin relaxation times
    • Jones JA, Hodgkinson P, Barker AL, Hore PJ,. Optimal sampling strategies for the measurement of spin-spin relaxation times. J Magn Reson Ser B 1996; 113: 25-34.
    • (1996) J Magn Reson ser B , vol.113 , pp. 25-34
    • Jones, J.A.1    Hodgkinson, P.2    Barker, A.L.3    Hore, P.J.4
  • 27
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson H, Patz S,. The Rician distribution of noisy MRI data. Magn Reson Med 1995; 34: 910-914.
    • (1995) Magn Reson Med , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 28
    • 84972487798 scopus 로고
    • Applications of the van Trees inequality: A Bayesian Cramér-Rao bound
    • Gill RD, Levit BY,. Applications of the van Trees inequality: a Bayesian Cramér-Rao bound. Bernoulli 1995; 1: 59-79.
    • (1995) Bernoulli , vol.1 , pp. 59-79
    • Gill, R.D.1    Levit, B.Y.2
  • 30
    • 84876466117 scopus 로고    scopus 로고
    • Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting
    • Xue H, Greiser A, Zuehlsdorff S, Jolly MP, Guehring J, Arai AE, Kellman P,. Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting. Magn Reson Med 2013; 69: 1408-1420.
    • (2013) Magn Reson Med , vol.69 , pp. 1408-1420
    • Xue, H.1    Greiser, A.2    Zuehlsdorff, S.3    Jolly, M.P.4    Guehring, J.5    Arai, A.E.6    Kellman, P.7
  • 31
    • 84928006347 scopus 로고    scopus 로고
    • Comparison of myocardial T1-mapping protocols: Accuracy and precision
    • Salt Lake City, Utah, USA, p
    • Kellman P, Xue H, Hansen MS,. Comparison of myocardial T1-mapping protocols: accuracy and precision. In Proceedings of the 21st Annual Meeting of ISMRM, Salt Lake City, Utah, USA, 2013. p. 1394.
    • (2013) Proceedings of the 21st Annual Meeting of ISMRM , pp. 1394
    • Kellman, P.1    Xue, H.2    Hansen, M.S.3
  • 34
    • 84928012972 scopus 로고    scopus 로고
    • Accuracy and reproducibility of four T1 mapping sequences: A head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE
    • Roujol S, Weingartner S, Foppa M, et al. Accuracy and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE. J Cardiovasc Magn Reson 2014; 16 (Suppl 1): O26.
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. O26
    • Roujol, S.1    Weingartner, S.2    Foppa, M.3
  • 35
    • 84883257373 scopus 로고    scopus 로고
    • T measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequences
    • Robson MD, Piechnik SK, Tunnicliffe EM, Neubauer S,. T measurements in the human myocardium: the effects of magnetization transfer on the SASHA and MOLLI sequences. Magn Reson Med 2013; 70: 664-670.
    • (2013) Magn Reson Med , vol.70 , pp. 664-670
    • Robson, M.D.1    Piechnik, S.K.2    Tunnicliffe, E.M.3    Neubauer, S.4
  • 36
    • 84880334617 scopus 로고    scopus 로고
    • Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI method
    • Kellman P, Herzka DA, Arai AE, Hansen MS,. Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI method. J Cardiovasc Magn Reson 2013; 15: 63.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 63
    • Kellman, P.1    Herzka, D.A.2    Arai, A.E.3    Hansen, M.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.