-
1
-
-
84888065063
-
Biparametric potentiometric analytical microsystem for nitrate and potassium monitoring in water recycling processes for manned space missions
-
Calvo-Lopez A., Arasa-Puig E., Puyol M., Casalta J.M., Alonso-Chamarro J. Biparametric potentiometric analytical microsystem for nitrate and potassium monitoring in water recycling processes for manned space missions. Anal. Chim. Acta 2013, 804:190-196.
-
(2013)
Anal. Chim. Acta
, vol.804
, pp. 190-196
-
-
Calvo-Lopez, A.1
Arasa-Puig, E.2
Puyol, M.3
Casalta, J.M.4
Alonso-Chamarro, J.5
-
2
-
-
0033086299
-
Water Recovery in Space
-
Tamponnet C., Savage C.J., Amblard P., Lasserre J.C., Personne J.C., Germain J.C. Water Recovery in Space. ESA Bull. 1999, 97:56-60.
-
(1999)
ESA Bull.
, vol.97
, pp. 56-60
-
-
Tamponnet, C.1
Savage, C.J.2
Amblard, P.3
Lasserre, J.C.4
Personne, J.C.5
Germain, J.C.6
-
3
-
-
77549088720
-
Exploration life support technology challenges for the crew exploration vehicle and future human missions
-
Jones H.W., Kliss M.H. Exploration life support technology challenges for the crew exploration vehicle and future human missions. Adv. Space Res. 2010, 45:917-928.
-
(2010)
Adv. Space Res.
, vol.45
, pp. 917-928
-
-
Jones, H.W.1
Kliss, M.H.2
-
4
-
-
79952620807
-
Regeneration of water at space stations
-
Grigoriev A.I., Sinyak Y.E., Samsonov N.M., Bobe L.S., Protasov N.N., Andreychuk P.O. Regeneration of water at space stations. Acta Astronaut. 2011, 68:1567-1573.
-
(2011)
Acta Astronaut.
, vol.68
, pp. 1567-1573
-
-
Grigoriev, A.I.1
Sinyak, Y.E.2
Samsonov, N.M.3
Bobe, L.S.4
Protasov, N.N.5
Andreychuk, P.O.6
-
5
-
-
0343720234
-
Flow injection system with gas diffusion for the sequential determination of total nitrogen and phosphorus in vegetables
-
Lima J.L.F.C., Rangel A.O.S.S., Souto M.R.S. Flow injection system with gas diffusion for the sequential determination of total nitrogen and phosphorus in vegetables. Fresenius J. Anal. Chem. 1997, 358:657-662.
-
(1997)
Fresenius J. Anal. Chem.
, vol.358
, pp. 657-662
-
-
Lima, J.L.F.C.1
Rangel, A.O.S.S.2
Souto, M.R.S.3
-
6
-
-
34548864408
-
A multi-commuted flow injection system with a multi-channel propulsion unit placed before detection: spectrophotometric determination of ammonium
-
Oliveira S.M., Lopes T.I.M.S., Tóth I.V., Rangel A.O.S.S. A multi-commuted flow injection system with a multi-channel propulsion unit placed before detection: spectrophotometric determination of ammonium. Anal. Chim. Acta 2007, 600:29-34.
-
(2007)
Anal. Chim. Acta
, vol.600
, pp. 29-34
-
-
Oliveira, S.M.1
Lopes, T.I.M.S.2
Tóth, I.V.3
Rangel, A.O.S.S.4
-
7
-
-
0000532377
-
Membrane separation in flow injection analysis, gas diffusion
-
Van der Linden W.E. Membrane separation in flow injection analysis, gas diffusion. Anal. Chim. Acta 1983, 151:359-369.
-
(1983)
Anal. Chim. Acta
, vol.151
, pp. 359-369
-
-
Van der Linden, W.E.1
-
8
-
-
0029111859
-
Evaluation of flow injection methods for ammonium determination in wastewater samples
-
Cerdà A., Oms M.T., Forteza R., Cerdà V. Evaluation of flow injection methods for ammonium determination in wastewater samples. Anal. Chim. Acta 1995, 311:165-173.
-
(1995)
Anal. Chim. Acta
, vol.311
, pp. 165-173
-
-
Cerdà, A.1
Oms, M.T.2
Forteza, R.3
Cerdà, V.4
-
9
-
-
0030028007
-
Gas diffusion techniques coupled sequential injection analysis for selective determination of ammonium
-
Oms M.T., Cerdà A., Cladera A., Cerdà V., Forteza R. Gas diffusion techniques coupled sequential injection analysis for selective determination of ammonium. Anal. Chim. Acta 1996, 318:251-260.
-
(1996)
Anal. Chim. Acta
, vol.318
, pp. 251-260
-
-
Oms, M.T.1
Cerdà, A.2
Cladera, A.3
Cerdà, V.4
Forteza, R.5
-
10
-
-
0024834285
-
Flow injection system for on-line potentiometric monitoring of a ammonia in freshwater streams
-
Alegret S., Alonso J., Bartroli J., Martinez-Fabregas E. Flow injection system for on-line potentiometric monitoring of a ammonia in freshwater streams. Analyst 1989, 114:1443-1447.
-
(1989)
Analyst
, vol.114
, pp. 1443-1447
-
-
Alegret, S.1
Alonso, J.2
Bartroli, J.3
Martinez-Fabregas, E.4
-
11
-
-
58149389333
-
Determination of ammonium in marine waters using a gas diffusion multicommuted flow injection system with in-line prevention of metal hydroxides precipitation
-
Oliveira S.M., Lopes T.I.M.S., Tóth I.V., Rangel A.O.S.S. Determination of ammonium in marine waters using a gas diffusion multicommuted flow injection system with in-line prevention of metal hydroxides precipitation. J. Environ. Monit. 2009, 11:228-234.
-
(2009)
J. Environ. Monit.
, vol.11
, pp. 228-234
-
-
Oliveira, S.M.1
Lopes, T.I.M.S.2
Tóth, I.V.3
Rangel, A.O.S.S.4
-
12
-
-
0037060168
-
Review: polymer microfluidic devices
-
Becker H., Locascio L.E. Review: polymer microfluidic devices. Talanta 2002, 56:267-287.
-
(2002)
Talanta
, vol.56
, pp. 267-287
-
-
Becker, H.1
Locascio, L.E.2
-
13
-
-
33344474359
-
New materials for electrochemical sensing. VII: microfluidic chip platforms
-
Pumera M., Merkoçi A., Alegret S. New materials for electrochemical sensing. VII: microfluidic chip platforms. Trends Anal. Chem. 2006, 25:219-235.
-
(2006)
Trends Anal. Chem.
, vol.25
, pp. 219-235
-
-
Pumera, M.1
Merkoçi, A.2
Alegret, S.3
-
14
-
-
39149145836
-
Green-tape ceramics. New technological approach for integrating electronics and fluidics in microsystems
-
Ibáñez-Garcia N., Martínez-Cisneros C.S., Valdés F., Alonso J. Green-tape ceramics. New technological approach for integrating electronics and fluidics in microsystems. Trends Anal. Chem. 2008, 27:24-33.
-
(2008)
Trends Anal. Chem.
, vol.27
, pp. 24-33
-
-
Ibáñez-Garcia, N.1
Martínez-Cisneros, C.S.2
Valdés, F.3
Alonso, J.4
-
15
-
-
37549023085
-
Polymer microfabrication technologies for microfluidic systems
-
Becker H., Gärtner C. Polymer microfabrication technologies for microfluidic systems. Anal. Bioanal. Chem. 2008, 390:89-111.
-
(2008)
Anal. Bioanal. Chem.
, vol.390
, pp. 89-111
-
-
Becker, H.1
Gärtner, C.2
-
16
-
-
0037060166
-
Towards autonomous environmental monitoring systems
-
Sequeira M., Bowden M., Minogue E., Diamond D. Towards autonomous environmental monitoring systems. Talanta 2002, 56:355-363.
-
(2002)
Talanta
, vol.56
, pp. 355-363
-
-
Sequeira, M.1
Bowden, M.2
Minogue, E.3
Diamond, D.4
-
17
-
-
0041837248
-
Integrating polymerase chain reaction valving, and electrophoresis in a plastic device for bacterial detection
-
Koh C.G., Tan W., Zhao M., Ricco A.J., Fan Z.H. Integrating polymerase chain reaction valving, and electrophoresis in a plastic device for bacterial detection. Anal. Chem. 2003, 75:4591-4598.
-
(2003)
Anal. Chem.
, vol.75
, pp. 4591-4598
-
-
Koh, C.G.1
Tan, W.2
Zhao, M.3
Ricco, A.J.4
Fan, Z.H.5
-
18
-
-
23744449423
-
Wafer-scale fabrication of polymer-based microdevices via injection molding and photolithographic micropatterning protocols
-
Lee D., Yang H., Chung K., Pyo H. Wafer-scale fabrication of polymer-based microdevices via injection molding and photolithographic micropatterning protocols. Anal. Chem. 2005, 77:5414-5420.
-
(2005)
Anal. Chem.
, vol.77
, pp. 5414-5420
-
-
Lee, D.1
Yang, H.2
Chung, K.3
Pyo, H.4
-
19
-
-
84874712649
-
A microflow analyzer with an integrated gas diffusion unit
-
Fonseca A., Silva J.C.B. A microflow analyzer with an integrated gas diffusion unit. J. Braz. Chem. Soc. 2013, 24:5-11.
-
(2013)
J. Braz. Chem. Soc.
, vol.24
, pp. 5-11
-
-
Fonseca, A.1
Silva, J.C.B.2
-
20
-
-
0030868333
-
Determination of ammonium in Kjeldahl digests by gas-diffusion flow-injection analysis with a bulk acoustic wave-impedance sensor
-
Su X., Nie L., Yao S. Determination of ammonium in Kjeldahl digests by gas-diffusion flow-injection analysis with a bulk acoustic wave-impedance sensor. Talanta 1997, 44:2121-2128.
-
(1997)
Talanta
, vol.44
, pp. 2121-2128
-
-
Su, X.1
Nie, L.2
Yao, S.3
-
21
-
-
0021846854
-
Comparison of tubular polymeric pH and ammonium ion electrodes as detectors in the automated determination of ammonia
-
Lee H.L., Meyerhofft M.E. Comparison of tubular polymeric pH and ammonium ion electrodes as detectors in the automated determination of ammonia. Analyst 1985, 110:371-376.
-
(1985)
Analyst
, vol.110
, pp. 371-376
-
-
Lee, H.L.1
Meyerhofft, M.E.2
-
22
-
-
0031055363
-
Determination of ammonia in waste waters by a differential pH method using flow injection potentiometry and a nonactin-based sensor
-
Shen H., Cardwell T.J., Cattrall R.W. Determination of ammonia in waste waters by a differential pH method using flow injection potentiometry and a nonactin-based sensor. Analyst 1997, 122:89-93.
-
(1997)
Analyst
, vol.122
, pp. 89-93
-
-
Shen, H.1
Cardwell, T.J.2
Cattrall, R.W.3
-
23
-
-
0029587703
-
Sequential analyte removal in flow analysis: determination of nitrogen, phosphorus and potassium in fertilizers
-
Martelli P.B., Neto J.A.G., Zagatto E.A.G., Brienza S.M.B., Montenegro M.C.B.S.M., Lima J.L.F.C. Sequential analyte removal in flow analysis: determination of nitrogen, phosphorus and potassium in fertilizers. Anal. Chim. Acta 1995, 317:239-245.
-
(1995)
Anal. Chim. Acta
, vol.317
, pp. 239-245
-
-
Martelli, P.B.1
Neto, J.A.G.2
Zagatto, E.A.G.3
Brienza, S.M.B.4
Montenegro, M.C.B.S.M.5
Lima, J.L.F.C.6
-
24
-
-
0012303399
-
Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system
-
Lima J.L.F.C., Montenegro M.C.B.S.M., Pinto A.P.M.M.O. Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system. Fresenius J. Anal. Chem. 1999, 364:353-357.
-
(1999)
Fresenius J. Anal. Chem.
, vol.364
, pp. 353-357
-
-
Lima, J.L.F.C.1
Montenegro, M.C.B.S.M.2
Pinto, A.P.M.M.O.3
-
25
-
-
84893507705
-
Gas diffusion as a new fluidic unit operation for centrifugal microfluidic platforms
-
Ymberm O., Sández N., Calvo-López A., Puyol M., Alonso J. Gas diffusion as a new fluidic unit operation for centrifugal microfluidic platforms. Lab Chip 2014, 14:1014-1022.
-
(2014)
Lab Chip
, vol.14
, pp. 1014-1022
-
-
Ymberm, O.1
Sández, N.2
Calvo-López, A.3
Puyol, M.4
Alonso, J.5
-
26
-
-
78650298737
-
Biparametric potentiometric analytical microsystem based on the green tape technology
-
Ibáñez-García N., Baeza M., Puyol M., Gómez R., Batlle M., Alonso-Chamarro J. Biparametric potentiometric analytical microsystem based on the green tape technology. Electroanalysis 2010, 22:2376-2382.
-
(2010)
Electroanalysis
, vol.22
, pp. 2376-2382
-
-
Ibáñez-García, N.1
Baeza, M.2
Puyol, M.3
Gómez, R.4
Batlle, M.5
Alonso-Chamarro, J.6
-
27
-
-
33646541056
-
Continuous flow analytical microsystems based on low-temperature co-fired ceramic technology. Integrated potentiometric detection based on solvent polymeric ion-selective electrodes
-
Ibanez-Garcia N., Bautista-Mercader M., Mendes da Rocha Z., Seabra C.A., Gongora-Rubio M.R., Alonso-Chamarro J. Continuous flow analytical microsystems based on low-temperature co-fired ceramic technology. Integrated potentiometric detection based on solvent polymeric ion-selective electrodes. Anal. Chem. 2006, 78:2985-2992.
-
(2006)
Anal. Chem.
, vol.78
, pp. 2985-2992
-
-
Ibanez-Garcia, N.1
Bautista-Mercader, M.2
Mendes da Rocha, Z.3
Seabra, C.A.4
Gongora-Rubio, M.R.5
Alonso-Chamarro, J.6
-
29
-
-
33847415823
-
A disposable on-chip phosphate sensor with planar cobalt microelectrodes on polymer substrate
-
Zoua Z., Han J., Jang A., Bishop P.L., Ahn C.H. A disposable on-chip phosphate sensor with planar cobalt microelectrodes on polymer substrate. Biosens. Bioelectron. 2007, 22:1902-1907.
-
(2007)
Biosens. Bioelectron.
, vol.22
, pp. 1902-1907
-
-
Zoua, Z.1
Han, J.2
Jang, A.3
Bishop, P.L.4
Ahn, C.H.5
-
30
-
-
41149118562
-
A polymer lab-on-a-chip for magnetic immunoassay with on-chip sampling and detection capabilities
-
Do J., Ahn C.H. A polymer lab-on-a-chip for magnetic immunoassay with on-chip sampling and detection capabilities. Lab Chip 2008, 8:542-549.
-
(2008)
Lab Chip
, vol.8
, pp. 542-549
-
-
Do, J.1
Ahn, C.H.2
-
31
-
-
84878346405
-
Electrochemical deposition and evaluation of electrically conductive polymer coating on biodegradable magnesium implants for neural applications
-
Sebaa M.A., Dhillon S., Liu H. Electrochemical deposition and evaluation of electrically conductive polymer coating on biodegradable magnesium implants for neural applications. J. Mater. Sci. Mater. Med. 2013, 24:307-316.
-
(2013)
J. Mater. Sci. Mater. Med.
, vol.24
, pp. 307-316
-
-
Sebaa, M.A.1
Dhillon, S.2
Liu, H.3
-
32
-
-
38549105511
-
Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report)
-
Lindner E., Umezawa Y. Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report). Pure Appl. Chem. 2008, 80:85-104.
-
(2008)
Pure Appl. Chem.
, vol.80
, pp. 85-104
-
-
Lindner, E.1
Umezawa, Y.2
|