Volumn 22, Issue 3, 2015, Pages 387-399

Automated breast volume scanning versus conventional ultrasound in breast cancer screening

Author keywords

Automated breast volume scanning; Breast cancer; Ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATED BREAST VOLUME SCANNING; AUTOMATION; BREAST BIOPSY; BREAST CANCER; BREAST DENSITY; BREAST EXAMINATION; BREAST LESION; CANCER SCREENING; COLOR ULTRASOUND FLOWMETRY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; ECHOMAMMOGRAPHY; FEMALE; HUMAN; HUMAN TISSUE; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; REAL TIME ULTRASOUND SCANNER; RETROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; ULTRASOUND TRANSDUCER; ADOLESCENT; AUTOMATED PATTERN RECOGNITION; BREAST; BREAST NEOPLASMS; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; MIDDLE AGED; ORGAN SIZE; PATHOLOGY; PROCEDURES; REPRODUCIBILITY; YOUNG ADULT;

EID: 84927691040     PISSN: 10766332     EISSN: 18784046     Source Type: Journal    
DOI: 10.1016/j.acra.2014.08.013     Document Type: Article
Times cited : (20)

References (26)
  • 2
    • 0036787397 scopus 로고    scopus 로고
    • Comparison of the performance of screening mammography, physical examination, and breast us and evaluation of factors that influence them: an analysis of 27,825 patient evaluations
    • Kolb T.M., Lichy J., Newhouse J.H. Comparison of the performance of screening mammography, physical examination, and breast us and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. Radiology 2002, 225(1):165-175.
    • (2002) Radiology , vol.225 , Issue.1 , pp. 165-175
    • Kolb, T.M.1    Lichy, J.2    Newhouse, J.H.3
  • 3
    • 0036277681 scopus 로고    scopus 로고
    • Comparison of breast mammography, sonography and physical examination for screening women at high risk of breast cancer in Taiwan
    • Hou M.F., Chuang H.Y., Ou-Yang F., et al. Comparison of breast mammography, sonography and physical examination for screening women at high risk of breast cancer in Taiwan. Ultrasound in medicine & biology 2002, 28(4):415-420.
    • (2002) Ultrasound in medicine & biology , vol.28 , Issue.4 , pp. 415-420
    • Hou, M.F.1    Chuang, H.Y.2    Ou-Yang, F.3
  • 4
    • 4444295767 scopus 로고    scopus 로고
    • Adverse effects of screening mammography
    • Feig S.A. Adverse effects of screening mammography. Radiologic Clinics of North America 2004, 42(5):807-819.
    • (2004) Radiologic Clinics of North America , vol.42 , Issue.5 , pp. 807-819
    • Feig, S.A.1
  • 5
    • 0035186291 scopus 로고    scopus 로고
    • Clinical utility of bilateral whole-breast US in the evaluation of women with dense breast tissue
    • Kaplan S.S. Clinical utility of bilateral whole-breast US in the evaluation of women with dense breast tissue. Radiology 2001, 221(3):641-649.
    • (2001) Radiology , vol.221 , Issue.3 , pp. 641-649
    • Kaplan, S.S.1
  • 6
    • 0029339282 scopus 로고
    • Critical pathways in using breast US
    • Mendelson E.B., Tobin C.E. Critical pathways in using breast US. Radiographics 1995, 15(4):935-945.
    • (1995) Radiographics , vol.15 , Issue.4 , pp. 935-945
    • Mendelson, E.B.1    Tobin, C.E.2
  • 7
    • 0038582463 scopus 로고    scopus 로고
    • The additional diagnostic value of ultrasonography in the diagnosis of breast cancer
    • Flobbe K., Bosch A.M., Kessels A.G., et al. The additional diagnostic value of ultrasonography in the diagnosis of breast cancer. Archives of internal medicine 2003, 163(10):1194.
    • (2003) Archives of internal medicine , vol.163 , Issue.10 , pp. 1194
    • Flobbe, K.1    Bosch, A.M.2    Kessels, A.G.3
  • 9
    • 84055207467 scopus 로고    scopus 로고
    • The automated breast volume scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases
    • Wojcinski S., Farrokh A., Hille U., et al. The automated breast volume scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases. International journal of women's health 2011, 3:337.
    • (2011) International journal of women's health , vol.3 , pp. 337
    • Wojcinski, S.1    Farrokh, A.2    Hille, U.3
  • 10
    • 84885782731 scopus 로고    scopus 로고
    • The clinical utility of automated breast volume scanner: a pilot study of 139 cases
    • Kim Y.W., Kim S.K., Youn H.J., et al. The clinical utility of automated breast volume scanner: a pilot study of 139 cases. Journal of breast cancer 2013, 16(3):329-334.
    • (2013) Journal of breast cancer , vol.16 , Issue.3 , pp. 329-334
    • Kim, Y.W.1    Kim, S.K.2    Youn, H.J.3
  • 11
    • 77955500347 scopus 로고    scopus 로고
    • Optimal scanning technique to cover the whole breast using an automated breast volume scanner
    • Tozaki M., Isobe S., Yamaguchi M., et al. Optimal scanning technique to cover the whole breast using an automated breast volume scanner. Japanese journal of radiology 2010, 28(4):325-328.
    • (2010) Japanese journal of radiology , vol.28 , Issue.4 , pp. 325-328
    • Tozaki, M.1    Isobe, S.2    Yamaguchi, M.3
  • 12
    • 84860585504 scopus 로고    scopus 로고
    • Automated breast volume scanner of ultrasound in initial application of breast occupation diseases
    • [J]
    • CHEN L., CHEN Y., PANG Y., et al. Automated breast volume scanner of ultrasound in initial application of breast occupation diseases. Chinese Journal of Medical Imaging Technology 2011, [J], 7, 021.
    • (2011) Chinese Journal of Medical Imaging Technology , vol.7 , pp. 021
    • Chen, L.1    Chen, Y.2    Pang, Y.3
  • 13
    • 84863240771 scopus 로고    scopus 로고
    • Detection of breast lesions using an automated breast volume scanner system
    • Zhang Q., Hu B., Li W.B. Detection of breast lesions using an automated breast volume scanner system. Journal of International Medical Research 2012, 40(1):300-306.
    • (2012) Journal of International Medical Research , vol.40 , Issue.1 , pp. 300-306
    • Zhang, Q.1    Hu, B.2    Li, W.B.3
  • 15
    • 67649195871 scopus 로고    scopus 로고
    • Analysis of 107 breast lesions with automated 3D ultrasound and comparison with mammography and manual ultrasound
    • Kotsianos-Hermle D., Hiltawsky K.M., Wirth S., et al. Analysis of 107 breast lesions with automated 3D ultrasound and comparison with mammography and manual ultrasound. European journal of radiology 2009, 71(1):109-115.
    • (2009) European journal of radiology , vol.71 , Issue.1 , pp. 109-115
    • Kotsianos-Hermle, D.1    Hiltawsky, K.M.2    Wirth, S.3
  • 16
    • 84879466488 scopus 로고    scopus 로고
    • Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results
    • Golatta M., Franz D., Harcos A., et al. Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results. European journal of radiology 2013.
    • (2013) European journal of radiology
    • Golatta, M.1    Franz, D.2    Harcos, A.3
  • 17
    • 79959935827 scopus 로고    scopus 로고
    • Detectability of breast lesions under the nipple using an automated breast volume scanner: comparison with handheld ultrasonography
    • Isobe S., Tozaki M., Yamaguchi M., et al. Detectability of breast lesions under the nipple using an automated breast volume scanner: comparison with handheld ultrasonography. Japanese Journal of Radiology 2011, 29(5):361-365.
    • (2011) Japanese Journal of Radiology , vol.29 , Issue.5 , pp. 361-365
    • Isobe, S.1    Tozaki, M.2    Yamaguchi, M.3
  • 18
    • 80052248587 scopus 로고    scopus 로고
    • Automated ultrasound of the breast for diagnosis: interobserver agreement on lesion detection and characterization
    • Shin H.J., Kim H.H., Cha J.H., et al. Automated ultrasound of the breast for diagnosis: interobserver agreement on lesion detection and characterization. American Journal of Roentgenology 2011, 197(3):747-754.
    • (2011) American Journal of Roentgenology , vol.197 , Issue.3 , pp. 747-754
    • Shin, H.J.1    Kim, H.H.2    Cha, J.H.3
  • 19
    • 0020660129 scopus 로고
    • The predictive value of certain mammographic signs in screening for breast cancer
    • Moskowitz M. The predictive value of certain mammographic signs in screening for breast cancer. Cancer 1983, 51(6):1007-1011.
    • (1983) Cancer , vol.51 , Issue.6 , pp. 1007-1011
    • Moskowitz, M.1
  • 20
    • 84927699285 scopus 로고    scopus 로고
    • ABVS aided diagnosis of breast ultrasound image based on BI-RADS in diagnosis of breast ductal carcinoma in situ
    • Zhu Q.Q., Bao L.Y., Zhu L.Q., et al. ABVS aided diagnosis of breast ultrasound image based on BI-RADS in diagnosis of breast ductal carcinoma in situ. Yixue Yingxiangxue Zazhi (Journal of Medical Imaging) 2012, 22(8).
    • (2012) Yixue Yingxiangxue Zazhi (Journal of Medical Imaging) , vol.22 , Issue.8
    • Zhu, Q.Q.1    Bao, L.Y.2    Zhu, L.Q.3
  • 22
    • 79959935827 scopus 로고    scopus 로고
    • Detectability of breast lesions under the nipple using an automated breast volume scanner: comparison with handheld ultrasonography
    • [J]
    • Isobe S., Tozaki M., Yamaguchi M., et al. Detectability of breast lesions under the nipple using an automated breast volume scanner: comparison with handheld ultrasonography. Jpn Radiol 2011, 29:361-365. [J].
    • (2011) Jpn Radiol , vol.29 , pp. 361-365
    • Isobe, S.1    Tozaki, M.2    Yamaguchi, M.3
  • 23
    • 84867009281 scopus 로고    scopus 로고
    • Differentiation of benign and malignant breast lesions: a comparison between automatically generated breast volume scans and handheld ultrasound examinations
    • Wanga H.Y., Jianga Y.X., Zhua Q.-L., et al. Differentiation of benign and malignant breast lesions: a comparison between automatically generated breast volume scans and handheld ultrasound examinations. European Journal of Radiology 2012, 81:3190-3200.
    • (2012) European Journal of Radiology , vol.81 , pp. 3190-3200
    • Wanga, H.Y.1    Jianga, Y.X.2    Zhua, Q.-L.3
  • 24
    • 84927696145 scopus 로고    scopus 로고
    • Ultrasonic automated breast volume scanning and Doppler ultrasonography imaging in different breast lesions
    • [J]
    • Chen C-J., Zhang Y., Shi X-y., et al. Ultrasonic automated breast volume scanning and Doppler ultrasonography imaging in different breast lesions. Clinical Focus 2012, 27(2):106-107. [J].
    • (2012) Clinical Focus , vol.27 , Issue.2 , pp. 106-107
    • Chen, C.-J.1    Zhang, Y.2    Shi, X.-Y.3
  • 25
    • 84055207467 scopus 로고    scopus 로고
    • The automated breast volume scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases
    • Wojcinski S., Farrokh A. The automated breast volume scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases. International Journal of Women's Health 2011, 3:337-346.
    • (2011) International Journal of Women's Health , vol.3 , pp. 337-346
    • Wojcinski, S.1    Farrokh, A.2
  • 26
    • 67649225505 scopus 로고    scopus 로고
    • First Clinical Use Of A Standardized Three-Dimensional Ultrasound For Breast Imaging
    • Kotsianos-Hermle a D., Wirth a S., Fischer a T., et al. First clinical use of a standardized three-dimensional ultrasound for breast imaging. European Journal of Radiology 2009, 71:102-108.
    • (2009) European Journal Of Radiology , vol.71 , pp. 102-108
    • Kotsianos-Hermle, A.D.1    Wirth, A.S.2    Fischer, A.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.