메뉴 건너뛰기




Volumn 70, Issue 5, 2015, Pages 577-584

Computational fluid dynamic modelling of the effect of ventilation mode and tracheal tube position on air flow in the large airways

Author keywords

[No Author keywords available]

Indexed keywords

AIRFLOW; AIRWAY; ARTICLE; ARTIFICIAL VENTILATION; BREATHING; COMPUTATIONAL FLUID DYNAMICS; ENDOTRACHEAL TUBE; HUMAN; LUNG; MATHEMATICAL MODEL; POSITION; THREE DIMENSIONAL MATHEMATICAL MODEL; TRACHEA; TRACHEAL TUBE POSITION; VELOCITY; AUDIOVISUAL EQUIPMENT; COMPUTER GRAPHICS; DEVICES; ENDOTRACHEAL INTUBATION; PHYSIOLOGY; PROCEDURES; RESPIRATION CONTROL; STATISTICAL MODEL;

EID: 84927032781     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/anae.13003     Document Type: Article
Times cited : (9)

References (17)
  • 1
    • 78649570901 scopus 로고    scopus 로고
    • Avoidance of endobronchial intubation. Measuring the depth of endotracheal tube insertion is simple and effective
    • O'Connor CJ,. Avoidance of endobronchial intubation. Measuring the depth of endotracheal tube insertion is simple and effective. British Medical Journal 2010; 341: 1111-2.
    • (2010) British Medical Journal , vol.341 , pp. 1111-1112
    • O'Connor, C.J.1
  • 2
    • 44649115837 scopus 로고    scopus 로고
    • Coanda effect as an explanation for unequal ventilation of the lungs in an intubated patient?
    • Qudaisat IY,. Coanda effect as an explanation for unequal ventilation of the lungs in an intubated patient? British Journal of Anaesthesia 2008; 100: 859-60.
    • (2008) British Journal of Anaesthesia , vol.100 , pp. 859-860
    • Qudaisat, I.Y.1
  • 3
    • 33847761875 scopus 로고    scopus 로고
    • Advances in magnetic resonance imaging of lung physiology
    • Hopkins SR, Levin DL, Emami K, et al. Advances in magnetic resonance imaging of lung physiology. Journal of Applied Physiology 2007; 102: 1244-54.
    • (2007) Journal of Applied Physiology , vol.102 , pp. 1244-1254
    • Hopkins, S.R.1    Levin, D.L.2    Emami, K.3
  • 5
    • 84872082407 scopus 로고    scopus 로고
    • Electrical impedance tomography: The holygrail of ventilation and perfusion monitoring?
    • Leonhardt S, Lachmann B,. Electrical impedance tomography: the holygrail of ventilation and perfusion monitoring? Intensive Care Medicine 2012; 38: 1917-29.
    • (2012) Intensive Care Medicine , vol.38 , pp. 1917-1929
    • Leonhardt, S.1    Lachmann, B.2
  • 6
    • 84879824595 scopus 로고    scopus 로고
    • Electrical impedance tomography for verification of correct endotracheal tube placement in paediatric patients: A feasibility study
    • Steinmann D, Engehausen M, Stiller B, Guttmann J,. Electrical impedance tomography for verification of correct endotracheal tube placement in paediatric patients: a feasibility study. Acta Anaesthesiologica Scandanavica 2013; 57: 881-7.
    • (2013) Acta Anaesthesiologica Scandanavica , vol.57 , pp. 881-887
    • Steinmann, D.1    Engehausen, M.2    Stiller, B.3    Guttmann, J.4
  • 7
    • 84880557884 scopus 로고    scopus 로고
    • Topographic distribution of tidal ventilation in acute respiratory distress syndrome: Effects of positive end-expiratory pressure and pressure support
    • Mauri T, Bellani G, Confalonieri A, et al. Topographic distribution of tidal ventilation in acute respiratory distress syndrome: effects of positive end-expiratory pressure and pressure support. Critical Care Medicine 2013; 41: 1664-73.
    • (2013) Critical Care Medicine , vol.41 , pp. 1664-1673
    • Mauri, T.1    Bellani, G.2    Confalonieri, A.3
  • 8
    • 0036725129 scopus 로고    scopus 로고
    • Radiological imaging as the basis for a simulation software of ventilation in the tracheo-bronchial tree
    • Ley S, Mayer D, Brook BS, et al. Radiological imaging as the basis for a simulation software of ventilation in the tracheo-bronchial tree. European Radiology 2002; 12: 2218-28.
    • (2002) European Radiology , vol.12 , pp. 2218-2228
    • Ley, S.1    Mayer, D.2    Brook, B.S.3
  • 9
    • 2042488807 scopus 로고    scopus 로고
    • Hybrid segmentation and virtual bronchoscopy based on CT images
    • Mayer D, Bartz D, Fischer J, et al. Hybrid segmentation and virtual bronchoscopy based on CT images. Academic Radiology 2004; 11: 551-65.
    • (2004) Academic Radiology , vol.11 , pp. 551-565
    • Mayer, D.1    Bartz, D.2    Fischer, J.3
  • 12
    • 78651322159 scopus 로고    scopus 로고
    • Vertical distribution of specific ventilation in normal supine humans measured by oxygen-enhanced proton MRI
    • Sá RC, Cronin MV, Henderson AC, et al. Vertical distribution of specific ventilation in normal supine humans measured by oxygen-enhanced proton MRI. Journal of Applied Physiology 2010; 109: 1950-9.
    • (2010) Journal of Applied Physiology , vol.109 , pp. 1950-1959
    • Sá, R.C.1    Cronin, M.V.2    Henderson, A.C.3
  • 13
    • 0028832980 scopus 로고
    • Contribution of the multiple inert gas elimination technique to pulmonary medicine 6: Ventilation-perfusion relationships during anaesthesia
    • Hedenstierna G,. Contribution of the multiple inert gas elimination technique to pulmonary medicine 6: ventilation-perfusion relationships during anaesthesia. Thorax 1995; 50: 85-91.
    • (1995) Thorax , vol.50 , pp. 85-91
    • Hedenstierna, G.1
  • 14
    • 0347428509 scopus 로고
    • Complications during endotracheal anesthesia
    • Bamforth BJ,. Complications during endotracheal anesthesia. Anesthesia and Analgesia 1963; 42: 727-32.
    • (1963) Anesthesia and Analgesia , vol.42 , pp. 727-732
    • Bamforth, B.J.1
  • 15
    • 33847231610 scopus 로고    scopus 로고
    • Proper insertion depth of endotracheal tubes in adults by topographic landmarks measurements
    • Evron S, Weisenberg M, Harow E, et al. Proper insertion depth of endotracheal tubes in adults by topographic landmarks measurements. Journal of Clinical Anesthesia 2007; 19: 15-9.
    • (2007) Journal of Clinical Anesthesia , vol.19 , pp. 15-19
    • Evron, S.1    Weisenberg, M.2    Harow, E.3
  • 16
    • 0032146391 scopus 로고    scopus 로고
    • Assessment of the proper depth of endotracheal tube placement with the trachlight
    • Locker GJ, Staudinger T, Knapp S, et al. Assessment of the proper depth of endotracheal tube placement with the trachlight. Journal of Clinical Anesthesia 1998; 10: 389-93.
    • (1998) Journal of Clinical Anesthesia , vol.10 , pp. 389-393
    • Locker, G.J.1    Staudinger, T.2    Knapp, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.