메뉴 건너뛰기




Volumn 10, Issue 5, 1998, Pages 389-393

Assessment of the proper depth of endotracheal tube placement with the trachlight

Author keywords

Proper endotracheal tube position; Trachlight(TM); Transillumination method

Indexed keywords

ARTICLE; DEPTH PERCEPTION; DIAGNOSTIC IMAGING; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; FIBEROPTIC BRONCHOSCOPY; POSITION; PRIORITY JOURNAL; RISK ASSESSMENT; THORAX RADIOGRAPHY; VENTILATOR;

EID: 0032146391     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0952-8180(98)00051-8     Document Type: Article
Times cited : (17)

References (14)
  • 2
    • 0024461731 scopus 로고
    • Assessment of routine chest roentgenograms and the physical examination to confirm endotracheal tube position
    • Brunel W, Coleman DL, Schwartz DE, Peper E, Cohen NH: Assessment of routine chest roentgenograms and the physical examination to confirm endotracheal tube position. Chest 1989; 96:1043-5.
    • (1989) Chest , vol.96 , pp. 1043-1045
    • Brunel, W.1    Coleman, D.L.2    Schwartz, D.E.3    Peper, E.4    Cohen, N.H.5
  • 3
    • 0025064183 scopus 로고
    • Radiographic detection of esophageal malpositioning of endotracheal tubes
    • Smith GM, Reed JC, Choplin RH: Radiographic detection of esophageal malpositioning of endotracheal tubes. AJR 1990;154: 23-6.
    • (1990) AJR , vol.154 , pp. 23-26
    • Smith, G.M.1    Reed, J.C.2    Choplin, R.H.3
  • 4
    • 0016654583 scopus 로고
    • Evaluation of endotracheal tube position with the fiberoptic intubation laryngoscope
    • Whitehouse AC, Klock LE: Evaluation of endotracheal tube position with the fiberoptic intubation laryngoscope [Letter]. Chest 1975;68:848.
    • (1975) Chest , vol.68 , pp. 848
    • Whitehouse, A.C.1    Klock, L.E.2
  • 5
    • 0017363143 scopus 로고
    • A simple method for verifying endotracheal tube placement
    • Kopman EA: A simple method for verifying endotracheal tube placement. Anesth Analg 1977;56:123-4.
    • (1977) Anesth Analg , vol.56 , pp. 123-124
    • Kopman, E.A.1
  • 6
    • 0026350145 scopus 로고
    • Management of the difficult adult airway. with special emphasis on awake tracheal intubation
    • Benumof JL: Management of the difficult adult airway. With special emphasis on awake tracheal intubation. Anesthesiology 1991;75:1087-110.
    • (1991) Anesthesiology , vol.75 , pp. 1087-1110
    • Benumof, J.L.1
  • 7
    • 0023217787 scopus 로고
    • Endobronchial intubation: A preventable complication
    • Owen RL, Cheney FW: Endobronchial intubation: a preventable complication. Anesthesiology 1987;67:255-7.
    • (1987) Anesthesiology , vol.67 , pp. 255-257
    • Owen, R.L.1    Cheney, F.W.2
  • 8
    • 0016873506 scopus 로고
    • Alteration of endotracheal tube position. Flexion and extension of the neck
    • Conrardy PA, Goodman LR, Laing F, Singer MM: Alteration of endotracheal tube position. Flexion and extension of the neck. Crit Care Med 1976;4:7-12.
    • (1976) Crit Care Med , vol.4 , pp. 7-12
    • Conrardy, P.A.1    Goodman, L.R.2    Laing, F.3    Singer, M.M.4
  • 9
    • 0027996802 scopus 로고
    • Alterations in endotracheal tube position during general anaesthesia
    • Yap SJ, Morris RW, Pybus DA: Alterations in endotracheal tube position during general anaesthesia. Anaesth Intensive Care 1994; 22:586-8.
    • (1994) Anaesth Intensive Care , vol.22 , pp. 586-588
    • Yap, S.J.1    Morris, R.W.2    Pybus, D.A.3
  • 10
    • 0028001453 scopus 로고
    • Influence of head and neck position on endotracheal tube tip position on chest x-ray examination: A potential problem in the infant undergoing intubation
    • Trout S, Aaron J, Zapta-Sirvent RL, Hansbrough JF: Influence of head and neck position on endotracheal tube tip position on chest x-ray examination: a potential problem in the infant undergoing intubation. J Burn Care Rehab 1994;15:405-7.
    • (1994) J Burn Care Rehab , vol.15 , pp. 405-407
    • Trout, S.1    Aaron, J.2    Zapta-Sirvent, R.L.3    Hansbrough, J.F.4
  • 11
    • 0024584087 scopus 로고
    • Transilluminated tracheal intubation
    • Ainsworth QP, Howells TH: Transilluminated tracheal intubation. Br J Anaesth 1989;62:494-7.
    • (1989) Br J Anaesth , vol.62 , pp. 494-497
    • Ainsworth, Q.P.1    Howells, T.H.2
  • 12
    • 0025177059 scopus 로고
    • Correct positioning of an endotracheal tube using a flexible lighted stylet
    • Stewart RD, LaRosee A, Kaplan RM, Ilkhanipour K: Correct positioning of an endotracheal tube using a flexible lighted stylet. Crit Care Med 1990;18:97-9.
    • (1990) Crit Care Med , vol.18 , pp. 97-99
    • Stewart, R.D.1    LaRosee, A.2    Kaplan, R.M.3    Ilkhanipour, K.4
  • 13
    • 0029050960 scopus 로고
    • Clinical trial of a new lightwand device (Trachlight) to intubate the trachea
    • Hung OR, Pytka S, Morris I, et al: Clinical trial of a new lightwand device (Trachlight) to intubate the trachea. Anesthesiology 1995; 83:509-14.
    • (1995) Anesthesiology , vol.83 , pp. 509-514
    • Hung, O.R.1    Pytka, S.2    Morris, I.3
  • 14
    • 0029116439 scopus 로고
    • Lightwand intubation: I - A new lightwand device
    • Hung OR, Stewart RD: Lightwand intubation: I - a new lightwand device. Can J Anaesth 1995;42:820-5.
    • (1995) Can J Anaesth , vol.42 , pp. 820-825
    • Hung, O.R.1    Stewart, R.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.