-
1
-
-
0025110612
-
Backfiltration in clinical dialysis. Nature of the phenomenon and possible solutions
-
Ronco C, Feriani M, Chiaramonte S, et al: Backfiltration in clinical dialysis. Nature of the phenomenon and possible solutions. Contrib Nephrol. Basel, Karger, 1990, vol 77, pp 96-105.
-
(1990)
Contrib Nephrol. Basel, Karger
, vol.77
, pp. 96-105
-
-
Ronco, C.1
Feriani, M.2
Chiaramonte, S.3
-
2
-
-
0021675147
-
Backfiltration in hemodialysis with high permeable membranes
-
Schmidt M, Baldamus CA, Schoeppe W: Backfiltration in hemodialysis with high permeable membranes. Blood Purif 1984;2: 108-114.
-
(1984)
Blood Purif
, vol.2
, pp. 108-114
-
-
Schmidt, M.1
Baldamus, C.A.2
Schoeppe, W.3
-
3
-
-
0025868291
-
Measurement of backfiltration rates during hemodialysis with highly permeable membranes
-
Leypoldt JK, Schmidt B, Gurland HJ: Measurement of backfiltration rates during hemodialysis with highly permeable membranes. Blood Purif 1991;9:74-84.
-
(1991)
Blood Purif
, vol.9
, pp. 74-84
-
-
Leypoldt, J.K.1
Schmidt, B.2
Gurland, H.J.3
-
4
-
-
84862919516
-
Optimization
-
in Jacobs C Kjellstrand CM Koch KM et al (eds), ed 4. Dordrecht, Kluwer Academic
-
Ronco C: Optimization; in Jacobs C, Kjellstrand CM, Koch KM, et al (eds): Replacement of Renal Function by Dialysis, ed 4. Dordrecht, Kluwer Academic, 2004, pp 133-145.
-
(2004)
Replacement of Renal Function by Dialysis
, pp. 133-145
-
-
Ronco, C.1
-
6
-
-
77952896419
-
Review: Membranes for haemodialysis
-
Kerr PG, Huang L: Review: Membranes for haemodialysis. Nephrology (Carlton) 2010;15:381-385.
-
(2010)
Nephrology (Carlton)
, vol.15
, pp. 381-385
-
-
Kerr, P.G.1
Huang, L.2
-
7
-
-
0036053971
-
Flow distribution and cross-filtration in hollow fiber hemodialyzers
-
Ronco C, Brendolan A, Crepaldi C, et al: Flow distribution and cross-filtration in hollow fiber hemodialyzers. Contrib Nephrol. Basel, Karger, 2002, vol 137, pp 120-128.
-
(2002)
Contrib Nephrol. Basel, Karger
, vol.137
, pp. 120-128
-
-
Ronco, C.1
Brendolan, A.2
Crepaldi, C.3
-
8
-
-
0025687058
-
Chronic haemodialysis with bicarbonate dialysate. Technical and clinical aspects
-
Leunissen KM, Claessens PJ, Mooy JM, et al: Chronic haemodialysis with bicarbonate dialysate. Technical and clinical aspects. Blood Purif 1990;8:347-358.
-
(1990)
Blood Purif
, vol.8
, pp. 347-358
-
-
Leunissen, K.M.1
Claessens, P.J.2
Mooy, J.M.3
-
9
-
-
0023378506
-
Potential bacteriologic and endotoxin hazards associated with liquid bicarbonate concentrate
-
Bland LA, Ridgeway MR, Aguero SM, et al: Potential bacteriologic and endotoxin hazards associated with liquid bicarbonate concentrate. ASAIO Trans 1987;33:542-545.
-
(1987)
ASAIO Trans
, vol.33
, pp. 542-545
-
-
Bland, L.A.1
Ridgeway, M.R.2
Aguero, S.M.3
-
10
-
-
0016180215
-
Microbial contamination of renal dialysis systems and associated health risks
-
Favero MS, Petersen NJ, Boyer KM, et al: Microbial contamination of renal dialysis systems and associated health risks. Trans Am Soc Artif Intern Organs 1974;20A:175-183.
-
(1974)
Trans Am Soc Artif Intern Organs
, vol.20 A
, pp. 175-183
-
-
Favero, M.S.1
Petersen, N.J.2
Boyer, K.M.3
-
11
-
-
0025291488
-
Detection of endotoxin antibody in long-term dialysis patients
-
Yamagami S, Adachi T, Sugimura T, et al: Detection of endotoxin antibody in longterm dialysis patients. Int J Artif Organs 1990;13:205-210. (Pubitemid 20239756)
-
(1990)
International Journal of Artificial Organs
, vol.13
, Issue.4
, pp. 205-210
-
-
Yamagami, S.1
Adachi, T.2
Sugimura, T.3
Wada, S.4
Kishimoto, T.5
Maekawa, M.6
Yoshimura, R.7
Niwa, M.8
Terano, Y.9
Shaldon, S.10
-
12
-
-
0025248389
-
Induction of IL-1 during hemodialysis: Transmembrane passage of intact endotoxins (LPS)
-
Laude-Sharp M, Caroff M, Simard L, et al: Induction of IL-1 during hemodialysis: Transmembrane passage of intact endotoxins (LPS). Kidney Int 1990;38:1089-1094.
-
(1990)
Kidney Int
, vol.38
, pp. 1089-1094
-
-
Laude-Sharp, M.1
Caroff, M.2
Simard, L.3
-
13
-
-
0031749863
-
Cytokine production in haemodiafiltration: A multicentre study
-
DOI 10.1093/ndt/13.7.1737
-
Panichi V, De Pietro S, Andreini B, et al: Cytokine production in haemodiafiltration: A multicentre study. Nephrol Dial Transplant 1998;13:1737-1744. (Pubitemid 28306804)
-
(1998)
Nephrology Dialysis Transplantation
, vol.13
, Issue.7
, pp. 1737-1744
-
-
Panichi, V.1
De Pietro, S.2
Andreini, B.3
Migliori, M.4
Tessore, V.5
Taccola, D.6
Rindi, P.7
Palla, R.8
Tetta, C.9
-
14
-
-
84862951334
-
-
IOS: Quality of dialysis fluid for haemodialysis and related therapies; in ISO 11663. International Organization for Standardization, 2009
-
IOS: Quality of dialysis fluid for haemodialysis and related therapies; in ISO 11663. International Organization for Standardization, 2009.
-
-
-
-
15
-
-
0036036693
-
Dialysis fluid purity
-
Section IV: Dialysis fluid purity. Nephrol Dial Transplant 2002;17(suppl 7):45-62.
-
(2002)
Nephrol Dial Transplant
, vol.17
, Issue.SUPPL. 7
, pp. 45-62
-
-
Section, I.V.1
-
16
-
-
79951791222
-
High-flux dialyzers, backfiltration, and dialysis fluid quality
-
Schiffl H: High-flux dialyzers, backfiltration, and dialysis fluid quality. Semin Dial 2011;24:1-4.
-
(2011)
Semin Dial
, vol.24
, pp. 1-4
-
-
Schiffl, H.1
-
17
-
-
0028149761
-
On line filtration of dialysate: Structural and functional features of an asymmetric polysulfone hollow fiber ultrafilter (Diaclean)
-
Ronco C, Cappelli G, Ballestri M, et al: On line filtration of dialysate: Structural and functional features of an asymmetric polysulfone hollow fiber ultrafilter (Diaclean). Int J Artif Organs 1994;17:515-520. (Pubitemid 24375885)
-
(1994)
International Journal of Artificial Organs
, vol.17
, Issue.10
, pp. 515-520
-
-
Ronco, C.1
Cappelli, G.2
Lusvarghi, E.3
Frisone, P.4
Milan, M.5
Dell'Aquila, R.6
Crepaldi, C.7
Dissegna, D.8
Gastaldon, F.9
La Greca, G.10
-
18
-
-
0026935027
-
A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin
-
Pegues DA, Oettinger CW, Bland LA, et al: A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin. J Am Soc Nephrol 1992;3:1002-1007.
-
(1992)
J Am Soc Nephrol
, vol.3
, pp. 1002-1007
-
-
Pegues, D.A.1
Oettinger, C.W.2
Bland, L.A.3
-
19
-
-
0035703897
-
Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis
-
DOI 10.1046/j.1525-1594.2001.06832.x
-
Lonnemann G, Sereni L, Lemke HD, et al: Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis. Artif Organs 2001;25:951-960. (Pubitemid 34107303)
-
(2001)
Artificial Organs
, vol.25
, Issue.12
, pp. 951-960
-
-
Lonnemann, G.1
Sereni, L.2
Lemke, H.-D.3
Tetta, C.4
-
20
-
-
0023890393
-
Backfiltration: A controversial issue in modern dialysis
-
Ronco C: Backfiltration: A controversial issue in modern dialysis. Int J Artif Organs 1988;11:69-74.
-
(1988)
Int J Artif Organs
, vol.11
, pp. 69-74
-
-
Ronco, C.1
-
21
-
-
0025261058
-
Backfiltration in clinical dialysis: Nature of the phenomenon, mechanisms and possible solutions
-
Ronco C: Backfiltration in clinical dialysis: Nature of the phenomenon, mechanisms and possible solutions. Int J Artif Organs 1990;13:11-21. (Pubitemid 20116941)
-
(1990)
International Journal of Artificial Organs
, vol.13
, Issue.1
, pp. 11-21
-
-
Ronco, C.1
-
22
-
-
0033852345
-
Potential of dual-skinned, high-flux membranes to reduce backtransport in hemodialysis
-
DOI 10.1046/j.1523-1755.2000.00231.x
-
Soltys PJ, Zydney A, Leypoldt JK, et al: Potential of dual-skinned, high-flux membranes to reduce backtransport in hemodialysis. Kidney Int 2000;58:818-828. (Pubitemid 30620032)
-
(2000)
Kidney International
, vol.58
, Issue.2
, pp. 818-828
-
-
Soltys, P.J.1
Zydney, A.2
Leypoldt, J.K.3
Henderson, L.W.4
Ofsthun, N.J.5
-
23
-
-
0034811399
-
New dialysis membrane for removal of middle molecule uremic toxins
-
Yamashita AC: New dialysis membrane for removal of middle molecule uremic toxins. Am J Kidney Dis 2001;38(4 suppl 1):S217-S219. (Pubitemid 32927648)
-
(2001)
American Journal of Kidney Diseases
, vol.38
, Issue.4 SUPPL. 1
-
-
Yamashita, A.C.1
-
24
-
-
0031708390
-
Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer technical note
-
Ronco C, Orlandini G, Brendolan A, et al: Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer: Technical note. Kidney Int 1998;54:979-985. (Pubitemid 28397419)
-
(1998)
Kidney International
, vol.54
, Issue.3
, pp. 979-985
-
-
Ronco, C.1
Orlandini, G.2
Brendolan, A.3
Lupi, A.4
La Greca, G.5
-
25
-
-
0025455929
-
Effects of EPO therapy on backfiltration of dialysate in high flux dialysis
-
Robertson BC, Curtin C: Effects of EPO therapy on backfiltration of dialysate in high-flux dialysis. ASAIO Trans 1990;36:M447-M452. (Pubitemid 20367096)
-
(1990)
ASAIO Transactions
, vol.36
, Issue.3
-
-
Robertson, B.C.1
Curtin, C.2
-
26
-
-
34547980351
-
Evolution of hemodiafiltration
-
Ronco C: Evolution of hemodiafiltration. Contrib Nephrol. Basel, Karger, 2007, vol 158, pp 9-19.
-
(2007)
Contrib Nephrol. Basel, Karger
, vol.158
, pp. 9-19
-
-
Ronco, C.1
-
27
-
-
0344505016
-
Theoretical model and first clinical results of the paired filtration-dialysis
-
Ghezzi PM, Frigato G, Fantini GF, et al: Theoretical model and first clinical results of the paired filtration-dialysis. Life Support Syst 1983;1(suppl 1):271-274.
-
(1983)
Life Support Syst
, vol.1
, Issue.SUPPL. 1
, pp. 271-274
-
-
Ghezzi, P.M.1
Frigato, G.2
Fantini, G.F.3
-
28
-
-
0025063033
-
Paired filtration dialysis: Studies on efficiency, flow dynamics and hydraulic properties of the system
-
Ronco C, Feriani M, Brendolan A, et al: Paired filtration dialysis: Studies on efficiency, flow dynamics and hydraulic properties of the system. Blood Purif 1990;8:126-140. (Pubitemid 20290565)
-
(1990)
Blood Purification
, vol.8
, Issue.3
, pp. 126-140
-
-
Ronco, C.1
Feriani, M.2
Brendolan, A.3
Chiaramonte, S.4
Milan, M.5
Dell'Aquila, R.6
Scabardi, M.7
Bragantini, L.8
Conz, P.9
La Greca, G.10
-
29
-
-
0343526783
-
Hemodiafiltration with on-line endogenous reinfusion
-
De Francisco AL, Pinera C, Heras M, et al: Hemodiafiltration with on-line endogenous reinfusion. Blood Purif 2000;18:231-236. (Pubitemid 30619962)
-
(2000)
Blood Purification
, vol.18
, Issue.3
, pp. 231-236
-
-
De Francisco, A.L.M.1
Pinera, C.2
Heras, M.3
Rodrigo, E.4
Fresnedo, G.F.5
Ruiz, J.C.6
Tetta, C.7
Arias, M.8
-
30
-
-
34547969525
-
Push/pull hemodiafiltration
-
Shinzato T, Maeda K: Push/pull hemodiafiltration. Contrib Nephrol. Basel, Karger, 2007, vol 158, pp 169-176.
-
(2007)
Contrib Nephrol. Basel, Karger
, vol.158
, pp. 169-176
-
-
Shinzato, T.1
Maeda, K.2
-
33
-
-
0033868074
-
Effects of a reduced inner diameter of hollow fibers in hemodialyzers
-
DOI 10.1046/j.1523-1755.2000.00230.x
-
Ronco C, Brendolan A, Lupi A, et al: Effects of a reduced inner diameter of hollow fibers in hemodialyzers. Kidney Int 2000;58:809-817. (Pubitemid 30620031)
-
(2000)
Kidney International
, vol.58
, Issue.2
, pp. 809-817
-
-
Ronco, C.1
Brendolan, A.2
Lupi, A.3
Metry, G.4
Levin, N.W.5
-
34
-
-
48349100276
-
Effect of high fiber density ratio polysulfone dialyzer on protein removal
-
Tomo T, Matsuyama M, Nakata T, et al: Effect of high fiber density ratio polysulfone dialyzer on protein removal. Blood Purif 2008;26:347-353.
-
(2008)
Blood Purif
, vol.26
, pp. 347-353
-
-
Tomo, T.1
Matsuyama, M.2
Nakata, T.3
-
35
-
-
3042524994
-
Clinical evaluation of internal hemodiafiltration (iHDF): A diffusive-convective technique performed with internal filtration enhanced high-flux dialyzers
-
Lucchi L, Fiore GB, Guadagni G, et al: Clinical evaluation of internal hemodiafiltration: A diffusive-convective technique performed with internal filtration enhanced high-flux dialyzers. Int J Artif Organs 2004;27:414-419. (Pubitemid 38812190)
-
(2004)
International Journal of Artificial Organs
, vol.27
, Issue.5
, pp. 414-419
-
-
Lucchi, L.1
Fiore, G.B.2
Guadagni, G.3
Perrone, S.4
Malaguti, V.5
Caruso, F.6
Fumero, R.7
Albertazzi, A.8
-
36
-
-
12544260391
-
Internal filtration-enhanced hemodialysis is a cost-effective treatment in view of solute removal
-
Koda Y: Internal filtration-enhanced hemodialysis is a cost-effective treatment in view of solute removal. Blood Purif 2004; 22(suppl 2):36-39.
-
(2004)
Blood Purif
, vol.22
, Issue.SUPPL. 2
, pp. 36-39
-
-
Koda, Y.1
|