메뉴 건너뛰기




Volumn 158, Issue , 2007, Pages 9-19

Evolution of hemodiafiltration

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ARTIFICIAL MEMBRANE; CHRONIC KIDNEY FAILURE; EQUIPMENT DESIGN; HEMODIAFILTRATION; HUMAN; INSTRUMENTATION; MEDICAL TECHNOLOGY; METHODOLOGY;

EID: 34547980351     PISSN: 03025144     EISSN: None     Source Type: Book Series    
DOI: 10.1159/0000107230     Document Type: Article
Times cited : (19)

References (29)
  • 2
    • 0016681819 scopus 로고
    • Kinetics of HDF. II. Clinical characterization of a new blood cleansing modality
    • Henderson LW, Colton CK, Ford C: Kinetics of HDF. II. Clinical characterization of a new blood cleansing modality. J Lab Clin Med 1975;85:372-375.
    • (1975) J Lab Clin Med , vol.85 , pp. 372-375
    • Henderson, L.W.1    Colton, C.K.2    Ford, C.3
  • 3
    • 0018045791 scopus 로고
    • Hemodiafiltration: A new alternative to hemofiltration and conventional hemodialysis
    • Leber H, Wizemann V, Goubeaud G, Rawer P, Schutterle G: Hemodiafiltration: a new alternative to hemofiltration and conventional hemodialysis. Artif Organs 1978;2:150-153.
    • (1978) Artif Organs , vol.2 , pp. 150-153
    • Leber, H.1    Wizemann, V.2    Goubeaud, G.3    Rawer, P.4    Schutterle, G.5
  • 4
  • 5
    • 0002900526 scopus 로고    scopus 로고
    • Dialyzer evaluation
    • Winchester J, Koch K, Jacobs C, Kjiellestrand C eds, Dordrecht, Kluwer Academic Publishers
    • Hoenich N, Ronco C: Dialyzer evaluation; in Winchester J, Koch K, Jacobs C, Kjiellestrand C (eds): Replacement of Renal Function by Dialysis. Dordrecht, Kluwer Academic Publishers, 1996, pp 256-270.
    • (1996) Replacement of Renal Function by Dialysis , pp. 256-270
    • Hoenich, N.1    Ronco, C.2
  • 7
    • 0016410946 scopus 로고
    • Quantitative description of dialysis treatment: A dialysis index
    • Babb AL, Strand MJ, Uvelli DA, et al: Quantitative description of dialysis treatment: a dialysis index. Kidney Int 1975;7(suppl 2):23-28.
    • (1975) Kidney Int , vol.7 , Issue.SUPPL. 2 , pp. 23-28
    • Babb, A.L.1    Strand, M.J.2    Uvelli, D.A.3
  • 8
    • 0036043882 scopus 로고    scopus 로고
    • The role of technology in hemodialysis
    • Ronco C, La Greca G eds, Basel, Karger
    • Ronco C, La Greca G: The role of technology in hemodialysis; in Ronco C, La Greca G (eds): Hemodialysis Technology. Contrib Nephrol. Basel, Karger, 2002, vol 137, pp 1-12.
    • (2002) Hemodialysis Technology. Contrib Nephrol , vol.137 , pp. 1-12
    • Ronco, C.1    La Greca, G.2
  • 9
    • 21644471890 scopus 로고    scopus 로고
    • Hemodiafiltration
    • Maduell F: Hemodiafiltration. Hemodial Int. 2005;9:47-55.
    • (2005) Hemodial Int , vol.9 , pp. 47-55
    • Maduell, F.1
  • 10
    • 0029561488 scopus 로고
    • Prescription and surveillance of the acetatefree biofiltration sessions: The bicarbonate cycle
    • Pacitti A, Casino FG, Pedrini L, Santoro A, Atti M: Prescription and surveillance of the acetatefree biofiltration sessions: the bicarbonate cycle. Int. J Artif Organs 1995;18:722-725.
    • (1995) Int. J Artif Organs , vol.18 , pp. 722-725
    • Pacitti, A.1    Casino, F.G.2    Pedrini, L.3    Santoro, A.4    Atti, M.5
  • 11
    • 0033864894 scopus 로고    scopus 로고
    • Impact of biofeedbackinduced cardiovascular stability on hemodialysis tolerance and efficiency
    • Ronco C, Brendolan A, Milan M, Rodighiero MP, Zanella M, La Greca G: Impact of biofeedbackinduced cardiovascular stability on hemodialysis tolerance and efficiency. Kidney Int 2000;58:800-808.
    • (2000) Kidney Int , vol.58 , pp. 800-808
    • Ronco, C.1    Brendolan, A.2    Milan, M.3    Rodighiero, M.P.4    Zanella, M.5    La Greca, G.6
  • 12
    • 31544467314 scopus 로고    scopus 로고
    • Transmembrane pressure modulation in high-volume mixed hemodiafiltration to optimize efficiency and minimize protein loss
    • Pedrini LA, Cozzi G, Faranna P, Mercieri A, Ruggiero P, Zerbi S, Feliciani A, Riva A: Transmembrane pressure modulation in high-volume mixed hemodiafiltration to optimize efficiency and minimize protein loss. Kidney Int 2006;69:573-579.
    • (2006) Kidney Int , vol.69 , pp. 573-579
    • Pedrini, L.A.1    Cozzi, G.2    Faranna, P.3    Mercieri, A.4    Ruggiero, P.5    Zerbi, S.6    Feliciani, A.7    Riva, A.8
  • 13
    • 12544256753 scopus 로고    scopus 로고
    • On-line hemodiafiltration as routine treatment of end-stage renal failure: Why pre- or mixed dilution mode is necessary in on-line hemodiafiltration today?
    • Canaud B, Levesque R, Krieter D, Desmeules S, Chalabi L, Moragues H, Morena M, Cristol JP: On-line hemodiafiltration as routine treatment of end-stage renal failure: why pre- or mixed dilution mode is necessary in on-line hemodiafiltration today? Blood Purif 2004;22(suppl 2):40-48.
    • (2004) Blood Purif , vol.22 , Issue.SUPPL. 2 , pp. 40-48
    • Canaud, B.1    Levesque, R.2    Krieter, D.3    Desmeules, S.4    Chalabi, L.5    Moragues, H.6    Morena, M.7    Cristol, J.P.8
  • 14
    • 29244474088 scopus 로고    scopus 로고
    • Dialysis patients and cardiovascular problems: Can technology help solve the complex equation?
    • Ronco C, Bowry S, Tetta C: Dialysis patients and cardiovascular problems: can technology help solve the complex equation? Blood Purif 2006;24:39-45.
    • (2006) Blood Purif , vol.24 , pp. 39-45
    • Ronco, C.1    Bowry, S.2    Tetta, C.3
  • 16
    • 0031708390 scopus 로고    scopus 로고
    • Enhancement of convectivo transport by internal filtration in a modified experimental hemodialyzer
    • Ronco C, Brendolan A, Lupi A, Bettini MC, La Greca G: Enhancement of convectivo transport by internal filtration in a modified experimental hemodialyzer. Kidney Int 1998;54:979-985.
    • (1998) Kidney Int , vol.54 , pp. 979-985
    • Ronco, C.1    Brendolan, A.2    Lupi, A.3    Bettini, M.C.4    La Greca, G.5
  • 17
    • 33845920152 scopus 로고    scopus 로고
    • A new semiempirical mathematical model, for prediction of internal filtration in. hollow fiber hemodialyzers
    • Fiore GB, Guadagni G, Lupi A, Ricci Z, Ronco C: A new semiempirical mathematical model, for prediction of internal filtration in. hollow fiber hemodialyzers. Blood Purif 2006;24:555-568.
    • (2006) Blood Purif , vol.24 , pp. 555-568
    • Fiore, G.B.1    Guadagni, G.2    Lupi, A.3    Ricci, Z.4    Ronco, C.5
  • 19
    • 0035717261 scopus 로고    scopus 로고
    • Continuous urea monitoring in hemodialysis: A model approach to forecast dialytic performance: results of a multicenter study
    • Arrigo G, Tetta C, Santoro A, Ghezzi. P, Ronco C, Colasanti G, La Greca G, Zucchelli P, D'Amico G: Continuous urea monitoring in hemodialysis: a model approach to forecast dialytic performance: results of a multicenter study. J Nephrol 2001;14:481-487.
    • (2001) J Nephrol , vol.14 , pp. 481-487
    • Arrigo, G.1    Tetta, C.2    Santoro, A.3    Ghezzi, P.4    Ronco, C.5    Colasanti, G.6    La Greca, G.7    Zucchelli, P.8    D'Amico, G.9
  • 20
    • 33845936798 scopus 로고    scopus 로고
    • A mathematical model for the prediction of solute kinetics, osmolarity and fluid volume changes during hemodiafiltration with on-line regeneration of ultrafiltrate (HFR)
    • Ursino M, Coli L, Magosso E, Capriotti P, Fiorenzi A, Baroni P, Stefoni S: A mathematical model for the prediction of solute kinetics, osmolarity and fluid volume changes during hemodiafiltration with on-line regeneration of ultrafiltrate (HFR). Int J Artif Organs 2006;29:1031-1040.
    • (2006) Int J Artif Organs , vol.29 , pp. 1031-1040
    • Ursino, M.1    Coli, L.2    Magosso, E.3    Capriotti, P.4    Fiorenzi, A.5    Baroni, P.6    Stefoni, S.7
  • 21
    • 33645833855 scopus 로고    scopus 로고
    • Evaluation of hygiene and safety controls for on-line paired hemodiafiltration (PHF)
    • Mandolfo S, Corsi A, Wratten ML, Sereni L, Imbasciati E: Evaluation of hygiene and safety controls for on-line paired hemodiafiltration (PHF). Int. J Artif Organs 2006;29:160-165.
    • (2006) Int. J Artif Organs , vol.29 , pp. 160-165
    • Mandolfo, S.1    Corsi, A.2    Wratten, M.L.3    Sereni, L.4    Imbasciati, E.5
  • 24
    • 0033390951 scopus 로고    scopus 로고
    • Push/pull hemodiafiltration: Technical aspects and clinical effectiveness
    • Miwa M, Shinzato T: Push/pull hemodiafiltration: technical aspects and clinical effectiveness. Artif Organs 1999;23:1123-1126.
    • (1999) Artif Organs , vol.23 , pp. 1123-1126
    • Miwa, M.1    Shinzato, T.2
  • 25
    • 0035651804 scopus 로고    scopus 로고
    • On-line preparation of solutions for dialysis: Practical aspects versus safety and regulations
    • Ledebo I: On-line preparation of solutions for dialysis: practical aspects versus safety and regulations. J Am Soc Nephrol 2002;23(suppl 1):S78-S83.
    • (2002) J Am Soc Nephrol , vol.23 , Issue.SUPPL. 1
    • Ledebo, I.1
  • 26
    • 0034003943 scopus 로고    scopus 로고
    • On-line haemodiafiltration: Safety and efficacy in long-term clinical practice
    • Canaud B, Bosc JY, Leray-Moragues H, et al: On-line haemodiafiltration: safety and efficacy in long-term clinical practice. Nephrol Dial Transplant 2000;5(suppl 1):S60-S67.
    • (2000) Nephrol Dial Transplant , vol.5 , Issue.SUPPL. 1
    • Canaud, B.1    Bosc, J.Y.2    Leray-Moragues, H.3
  • 27
    • 0038558131 scopus 로고    scopus 로고
    • On-line production of ultrapure substitution fluid reduces TNF-alpha- and IL-6 release in patients on hemodiafiltration therapy
    • Guth HJ, Gruska S, Kraatz G: On-line production of ultrapure substitution fluid reduces TNF-alpha- and IL-6 release in patients on hemodiafiltration therapy. Int J Artif Organs 2003;26:181-187.
    • (2003) Int J Artif Organs , vol.26 , pp. 181-187
    • Guth, H.J.1    Gruska, S.2    Kraatz, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.