메뉴 건너뛰기




Volumn 3, Issue 5, 2013, Pages 303-312

Fused-core particle technology in high-performance liquid chromatography: An overview

Author keywords

Core shell particles; Drug separations; Fused core particles; Peptides; Proteins; Superficially porous particles

Indexed keywords

4 HYDROXYCOUMARIN; ACETONITRILE; ALPHA1 GLYCOPROTEIN; AMMONIUM ACETATE; AMMONIUM FORMATE; BOVINE INSULIN; CARBONATE DEHYDRATASE; CATALASE; CHYMOTRYPSIN A; CLONAZEPAM; COUMARIN; COUMATETRALYL; DESIPRAMINE; DIAZEPAM; ENOLASE; FLUNITRAZEPAM; FORMIC ACID; HUMAN INSULIN; IMIPRAMINE; LORAZEPAM; LYSOZYME; NITRAZEPAM; OXAZEPAM; RIBONUCLEASE A; RIMONABANT; TEMAZEPAM; TRIFLUOROACETIC ACID; URACIL; WARFARIN;

EID: 84925835408     PISSN: 20951779     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jpha.2013.02.005     Document Type: Article
Times cited : (76)

References (21)
  • 1
    • 40449103315 scopus 로고    scopus 로고
    • Characteristics of superficially-porous silica particles for fast HPLC: Some performance comparisons with sub-2-μm particles
    • J. DeStefano, T. Langlois, and J. Kirkland Characteristics of superficially-porous silica particles for fast HPLC: some performance comparisons with sub-2-μm particles J. Chromatogr. Sci. 46 2008 254 260
    • (2008) J. Chromatogr. Sci. , vol.46 , pp. 254-260
    • Destefano, J.1    Langlois, T.2    Kirkland, J.3
  • 2
    • 37848999751 scopus 로고    scopus 로고
    • Fused core particle technology as an alternative to sub-2 μm particles to achieve high separation efficiency with low backpressure
    • J. Cunliffe, and T. Maloney Fused core particle technology as an alternative to sub-2 μm particles to achieve high separation efficiency with low backpressure J. Sep. Sci. 30 2007 3104 3109
    • (2007) J. Sep. Sci. , vol.30 , pp. 3104-3109
    • Cunliffe, J.1    Maloney, T.2
  • 3
    • 56549122608 scopus 로고    scopus 로고
    • Fused-core particles: A practical alternative to sub-2 μm particles
    • J. Salisbury Fused-core particles: a practical alternative to sub-2 μm particles J. Chromatogr. Sci. 46 2008 883 886
    • (2008) J. Chromatogr. Sci. , vol.46 , pp. 883-886
    • Salisbury, J.1
  • 4
    • 34547832128 scopus 로고    scopus 로고
    • Fused core particles for HPLC columns
    • J. Kirkland, T. Langlois, and J. DeStefano Fused core particles for HPLC columns Am. Lab. 39 2007 18 21
    • (2007) Am. Lab. , vol.39 , pp. 18-21
    • Kirkland, J.1    Langlois, T.2    Destefano, J.3
  • 5
    • 77955743161 scopus 로고    scopus 로고
    • Wider pore superficially porous particles for peptide separations by HPLC
    • S.A. Schuster, B.M. Wagner, and B.E. Boyes Wider pore superficially porous particles for peptide separations by HPLC J. Chromatogr. Sci. 48 2010 566 571
    • (2010) J. Chromatogr. Sci. , vol.48 , pp. 566-571
    • Schuster, S.A.1    Wagner, B.M.2    Boyes, B.E.3
  • 6
    • 84859268779 scopus 로고    scopus 로고
    • Evaluation of a new wide pore core-shell material (Aeris™ WIDEPORE) and comparison with other existing stationary phases for the analysis of intact proteins
    • S. Fekete, R. Berky, and J. Fekete Evaluation of a new wide pore core-shell material (Aeris™ WIDEPORE) and comparison with other existing stationary phases for the analysis of intact proteins J. Chromatogr. A 1236 2012 177 188
    • (2012) J. Chromatogr. A , vol.1236 , pp. 177-188
    • Fekete, S.1    Berky, R.2    Fekete, J.3
  • 7
    • 84867900832 scopus 로고    scopus 로고
    • Superficially porous silica particles with wide pores for biomacromolecular separations
    • B.M. Wagner, S.A. Schuster, and B.E. Boyes Superficially porous silica particles with wide pores for biomacromolecular separations J. Chromatogr. A 2012 22 30
    • (2012) J. Chromatogr. A , pp. 22-30
    • Wagner, B.M.1    Schuster, S.A.2    Boyes, B.E.3
  • 8
    • 84866015063 scopus 로고    scopus 로고
    • Performance characteristics of new superficially porous particles
    • J. DeStefano, S.A. Schuster, and J.M. Lawhorn Performance characteristics of new superficially porous particles J. Chromatogr. A 1258 2012 76 83
    • (2012) J. Chromatogr. A , vol.1258 , pp. 76-83
    • Destefano, J.1    Schuster, S.A.2    Lawhorn, J.M.3
  • 12
    • 0017522710 scopus 로고
    • Sampling and extra-column effects in high-performance liquid chromatography; Influence of peak skew on plate count calculations
    • J.J. Kirkland, W.W. Yau, and H.J. Stocklosa Sampling and extra-column effects in high-performance liquid chromatography; influence of peak skew on plate count calculations J. Chromatogr. Sci. 15 1977 303 316
    • (1977) J. Chromatogr. Sci. , vol.15 , pp. 303-316
    • Kirkland, J.J.1    Yau, W.W.2    Stocklosa, H.J.3
  • 13
    • 77951205929 scopus 로고    scopus 로고
    • Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments
    • F. Gritti, C.A. Sanchez, and T. Farkas Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments J. Chromatogr. A 1217 2010 3000 3012
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3000-3012
    • Gritti, F.1    Sanchez, C.A.2    Farkas, T.3
  • 14
    • 34547743751 scopus 로고    scopus 로고
    • Fused-core silica column high-performance liquid chromatography/tandem mass spectrometric determination of rimonabant in mouse plasma
    • Y. Hsieh, C. Duncan, and J. Brisson Fused-core silica column high-performance liquid chromatography/tandem mass spectrometric determination of rimonabant in mouse plasma Anal. Chem. 79 2007 5668 5673
    • (2007) Anal. Chem. , vol.79 , pp. 5668-5673
    • Hsieh, Y.1    Duncan, C.2    Brisson, J.3
  • 15
    • 72149119460 scopus 로고    scopus 로고
    • Optimization and validation of a high performance liquid chromatography method for rapid determination of sinafloxacin, a novel fluoroquinolone in rat plasma using a fused-core C18-silica column
    • S. Wang, J. Wen, and L. Cui Optimization and validation of a high performance liquid chromatography method for rapid determination of sinafloxacin, a novel fluoroquinolone in rat plasma using a fused-core C18-silica column J. Pharm. Biomed. Anal. 51 2010 889 893
    • (2010) J. Pharm. Biomed. Anal. , vol.51 , pp. 889-893
    • Wang, S.1    Wen, J.2    Cui, L.3
  • 16
    • 77955842014 scopus 로고    scopus 로고
    • Accelerating high quality bioanalytical LC/MS/MS assays using fused-core columns
    • E.R. Badman, R.L. Beardsley, and Z. Liang Accelerating high quality bioanalytical LC/MS/MS assays using fused-core columns J. Chromatogr. B 878 2010 2307 2313
    • (2010) J. Chromatogr. B , vol.878 , pp. 2307-2313
    • Badman, E.R.1    Beardsley, R.L.2    Liang, Z.3
  • 17
    • 65649138794 scopus 로고    scopus 로고
    • A high-throughput LC-MS/MS method for the quantitation of posaconazole in human plasma: Implementing fused core silica liquid chromatography
    • J. Cunliffe, C. Noren, and R. Hayes A high-throughput LC-MS/MS method for the quantitation of posaconazole in human plasma: implementing fused core silica liquid chromatography J. Pharm. Biomed. Anal. 50 2009 46 52
    • (2009) J. Pharm. Biomed. Anal. , vol.50 , pp. 46-52
    • Cunliffe, J.1    Noren, C.2    Hayes, R.3
  • 18
    • 58249131745 scopus 로고    scopus 로고
    • The use of partially porous particle columns for the routine, generic analysis of biological samples for pharmacokinetic studies in drug discovery by reversed-phase ultra-high performance liquid chromatography-tandem mass spectrometry
    • D.N. Mallett, and C. Ramirez-Molina The use of partially porous particle columns for the routine, generic analysis of biological samples for pharmacokinetic studies in drug discovery by reversed-phase ultra-high performance liquid chromatography-tandem mass spectrometry J. Pharm. Biomed. Anal. 49 2009 100 107
    • (2009) J. Pharm. Biomed. Anal. , vol.49 , pp. 100-107
    • Mallett, D.N.1    Ramirez-Molina, C.2
  • 19
    • 67650364379 scopus 로고    scopus 로고
    • Comparison of fused-core and conventional particle size columns by LC-MS/MS and UV: Application to pharmacokinetic study
    • W. Song, D. Pabbisetty, and E. Groeber Comparison of fused-core and conventional particle size columns by LC-MS/MS and UV: application to pharmacokinetic study J. Pharm. Biomed. Anal. 50 2009 491 500
    • (2009) J. Pharm. Biomed. Anal. , vol.50 , pp. 491-500
    • Song, W.1    Pabbisetty, D.2    Groeber, E.3
  • 20
    • 0035979756 scopus 로고    scopus 로고
    • Ultra-short columns and ballistic gradients: Considerations for ultra-fast chromatographic liquid chromatographic-tandem mass spectrometric analysis
    • L.A. Romanyshyn, and P.R. Tiller Ultra-short columns and ballistic gradients: considerations for ultra-fast chromatographic liquid chromatographic-tandem mass spectrometric analysis J. Chromatogr. A 928 2001 41 51
    • (2001) J. Chromatogr. A , vol.928 , pp. 41-51
    • Romanyshyn, L.A.1    Tiller, P.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.