-
1
-
-
30844463248
-
Assessment of reproducibility and stability of different breath-hold manoeuvres by dynamic MRI: Comparison between healthy adults and patients with pulmonary hypertension
-
Plathow C, Ley S, Zaporozhan J, Schöbinger M, Gruenig E, Puderbach M, Eichinger M, Meinzer HP, Zuna I, Kauczor HU,. Assessment of reproducibility and stability of different breath-hold manoeuvres by dynamic MRI: comparison between healthy adults and patients with pulmonary hypertension. Eur Radiol 2006; 16: 173-179.
-
(2006)
Eur Radiol
, vol.16
, pp. 173-179
-
-
Plathow, C.1
Ley, S.2
Zaporozhan, J.3
Schöbinger, M.4
Gruenig, E.5
Puderbach, M.6
Eichinger, M.7
Meinzer, H.P.8
Zuna, I.9
Kauczor, H.U.10
-
2
-
-
60349125586
-
3d cine displacement-encoded MRI of pulsatile brain motion
-
Soellinger M, Rutz AK, Kozerke S, Boesiger P,. 3d cine displacement-encoded MRI of pulsatile brain motion. Magn Reson Med 2009; 61: 153-162.
-
(2009)
Magn Reson Med
, vol.61
, pp. 153-162
-
-
Soellinger, M.1
Rutz, A.K.2
Kozerke, S.3
Boesiger, P.4
-
3
-
-
84874371031
-
Prospective motion correction in brain imaging: A review
-
Maclaren J, Herbst M, Speck O, Zaitsev M,. Prospective motion correction in brain imaging: a review. Magn Reson Med 2012; 69: 621-636.
-
(2012)
Magn Reson Med
, vol.69
, pp. 621-636
-
-
MacLaren, J.1
Herbst, M.2
Speck, O.3
Zaitsev, M.4
-
4
-
-
0036770219
-
Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3d image registration
-
Manke D, Rösch P, Nehrke K, Börnert P, Dössel O,. Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3d image registration. IEEE Trans Med Imaging 2002; 21: 1132-1141.
-
(2002)
IEEE Trans Med Imaging
, vol.21
, pp. 1132-1141
-
-
Manke, D.1
Rösch, P.2
Nehrke, K.3
Börnert, P.4
Dössel, O.5
-
6
-
-
27644511256
-
Matrix description of general motion correction applied to multishot images
-
Batchelor P, Atkinson D, Irarrazaval P, Hill D, Hajnal J, Larkman D,. Matrix description of general motion correction applied to multishot images. Magn Reson Med 2005; 54: 1273-1280.
-
(2005)
Magn Reson Med
, vol.54
, pp. 1273-1280
-
-
Batchelor, P.1
Atkinson, D.2
Irarrazaval, P.3
Hill, D.4
Hajnal, J.5
Larkman, D.6
-
7
-
-
44949166653
-
Generalized MRI reconstruction including elastic physiological motion and coil sensitivity encoding
-
Odille F, Cîndea N, Mandry D, Pasquier C, Vuissoz PA, Felblinger J,. Generalized MRI reconstruction including elastic physiological motion and coil sensitivity encoding. Magn Reson Med 2008; 59: 1401-1411.
-
(2008)
Magn Reson Med
, vol.59
, pp. 1401-1411
-
-
Odille, F.1
Cîndea, N.2
Mandry, D.3
Pasquier, C.4
Vuissoz, P.A.5
Felblinger, J.6
-
8
-
-
81355161604
-
Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA
-
Schmidt J, Buehrer M, Boesiger P, Kozerke S,. Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA. Magn Reson Med 2011; 66: 1541-1549.
-
(2011)
Magn Reson Med
, vol.66
, pp. 1541-1549
-
-
Schmidt, J.1
Buehrer, M.2
Boesiger, P.3
Kozerke, S.4
-
9
-
-
77955300174
-
Model-based reconstruction for cardiac cine MRI without ECG or breath holding
-
Odille F, Uribe S, Batchelor PG, Prieto C, Schäffter T, Atkinson D,. Model-based reconstruction for cardiac cine MRI without ECG or breath holding. Magn Reson Med 2010; 63: 1247-1257.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1247-1257
-
-
Odille, F.1
Uribe, S.2
Batchelor, P.G.3
Prieto, C.4
Schäffter, T.5
Atkinson, D.6
-
10
-
-
84856277712
-
Free-breathing imaging of the heart using 2d cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function
-
Vuissoz PA, Odille F, Fernandez B, Lohezic M, Benhadid A, Mandry D, Felblinger J,. Free-breathing imaging of the heart using 2d cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function. J Magn Reson Imaging 2012; 35: 340-351.
-
(2012)
J Magn Reson Imaging
, vol.35
, pp. 340-351
-
-
Vuissoz, P.A.1
Odille, F.2
Fernandez, B.3
Lohezic, M.4
Benhadid, A.5
Mandry, D.6
Felblinger, J.7
-
11
-
-
84865478167
-
Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction
-
Hansen M, Sørensen T, Arai A, Kellman P,. Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction. Magn Reson Med 2012; 68: 741-750.
-
(2012)
Magn Reson Med
, vol.68
, pp. 741-750
-
-
Hansen, M.1
Sørensen, T.2
Arai, A.3
Kellman, P.4
-
12
-
-
67749133780
-
Motion artifact correction in free-breathing abdominal MRI using overlapping partial samples to recover image deformations
-
White MJ, Hawkes DJ, Melbourne A, Collins DJ, Coolens C, Hawkins M, Leach MO, Atkinson D,. Motion artifact correction in free-breathing abdominal MRI using overlapping partial samples to recover image deformations. Magn Reson Med 2009; 62: 440-449.
-
(2009)
Magn Reson Med
, vol.62
, pp. 440-449
-
-
White, M.J.1
Hawkes, D.J.2
Melbourne, A.3
Collins, D.J.4
Coolens, C.5
Hawkins, M.6
Leach, M.O.7
Atkinson, D.8
-
13
-
-
46849091615
-
Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI
-
Odille F, Vuissoz P, Marie P, Felblinger J,. Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI. Magn Reson Med 2008; 60: 146-157.
-
(2008)
Magn Reson Med
, vol.60
, pp. 146-157
-
-
Odille, F.1
Vuissoz, P.2
Marie, P.3
Felblinger, J.4
-
14
-
-
84872509979
-
Joint reconstruction of image and motion in MRI: Implicit regularization using an adaptive 3D mesh
-
Menini A, Vuissoz PA, Felblinger J, Odille F,. Joint reconstruction of image and motion in MRI: implicit regularization using an adaptive 3D mesh. Med Image Comput Comput Assist Interv 2012; 15: 264-271.
-
(2012)
Med Image Comput Comput Assist Interv
, vol.15
, pp. 264-271
-
-
Menini, A.1
Vuissoz, P.A.2
Felblinger, J.3
Odille, F.4
-
15
-
-
84870052858
-
Nonrigid motion correction in 3d using autofocusing with localized linear translations
-
Cheng JY, Alley MT, Cunningham CH, Vasanawala SS, Pauly JM, Lustig M,. Nonrigid motion correction in 3d using autofocusing with localized linear translations. Magn Reson Med 2012; 68: 1785-1997.
-
(2012)
Magn Reson Med
, vol.68
, pp. 1785-1997
-
-
Cheng, J.Y.1
Alley, M.T.2
Cunningham, C.H.3
Vasanawala, S.S.4
Pauly, J.M.5
Lustig, M.6
-
16
-
-
84881188787
-
Motion corrected compressed sensing for free-breathing dynamic cardiac MRI
-
Usman M, Atkinson D, Odille F, Kolbitsch C, Vaillant G, Schaeffter T, Batchelor PG, Prieto C,. Motion corrected compressed sensing for free-breathing dynamic cardiac MRI. Magn Reson Med 2012; 70: 504-516.
-
(2012)
Magn Reson Med
, vol.70
, pp. 504-516
-
-
Usman, M.1
Atkinson, D.2
Odille, F.3
Kolbitsch, C.4
Vaillant, G.5
Schaeffter, T.6
Batchelor, P.G.7
Prieto, C.8
-
17
-
-
84887987972
-
Blind retrospective motion correction of MR images
-
Loktyushin A, Nickisch H, Pohmann R, Schölkopf B,. Blind retrospective motion correction of MR images. Magn Reson Med 2013; 70: 1608-1618.
-
(2013)
Magn Reson Med
, vol.70
, pp. 1608-1618
-
-
Loktyushin, A.1
Nickisch, H.2
Pohmann, R.3
Schölkopf, B.4
-
19
-
-
77956001536
-
-
San Francisco, California, USA
-
Hirsch M, Sra S, Schölkopf B, Harmeling S,. Efficient filter flow for space-variant multiframe blind deconvolution. In IEEE Conference on Computer Vision and Pattern Recognition (CVPR), San Francisco, California, USA, 2010. pp 607-614.
-
(2010)
Efficient Filter Flow for Space-variant Multiframe Blind Deconvolution. in IEEE Conference on Computer Vision and Pattern Recognition (CVPR)
, pp. 607-614
-
-
Hirsch, M.1
Sra, S.2
Schölkopf, B.3
Harmeling, S.4
-
20
-
-
0021958023
-
MR image artifacts from periodic motion
-
Wood M, Henkelman R,. MR image artifacts from periodic motion. Med Phys 1985; 12: 143 -151.
-
(1985)
Med Phys
, vol.12
, pp. 143-151
-
-
Wood, M.1
Henkelman, R.2
-
21
-
-
79958071014
-
An image-based approach to understanding the physics of MR artifacts
-
Morelli J, Runge V, Ai F, Attenberger U, Vu L, Schmeets S, Nitz W, Kirsch J,. An image-based approach to understanding the physics of MR artifacts. Radiographics 2011; 31: 849-866.
-
(2011)
Radiographics
, vol.31
, pp. 849-866
-
-
Morelli, J.1
Runge, V.2
Ai, F.3
Attenberger, U.4
Vu, L.5
Schmeets, S.6
Nitz, W.7
Kirsch, J.8
-
22
-
-
0033953459
-
Image metric-based correction (autocorrection) of motion effects: Analysis of image metrics
-
McGee K, Manduca A, Felmlee J, Riederer S, Ehman R,. Image metric-based correction (autocorrection) of motion effects: analysis of image metrics. J Magn Reson Imaging 2000; 11: 174-181.
-
(2000)
J Magn Reson Imaging
, vol.11
, pp. 174-181
-
-
McGee, K.1
Manduca, A.2
Felmlee, J.3
Riederer, S.4
Ehman, R.5
-
23
-
-
0000732463
-
A limited memory algorithm for bound constrained optimization
-
Byrd RH, Lu P, Nocedal J, Zhu C,. A limited memory algorithm for bound constrained optimization. SIAM J Sci Stat Comput 1995; 16: 1190-1208.
-
(1995)
SIAM J Sci Stat Comput
, vol.16
, pp. 1190-1208
-
-
Byrd, R.H.1
Lu, P.2
Nocedal, J.3
Zhu, C.4
-
24
-
-
33749249573
-
Removing camera shake from a single photograph
-
Fergus R, Singh B, Hertzmann A, Roweis ST, Freeman WT,. Removing camera shake from a single photograph. ACM Trans Graphics 2006; 25: 787-794.
-
(2006)
ACM Trans Graphics
, vol.25
, pp. 787-794
-
-
Fergus, R.1
Singh, B.2
Hertzmann, A.3
Roweis, S.T.4
Freeman, W.T.5
-
25
-
-
77749243157
-
Fast motion deblurring
-
Cho S, Lee S,. Fast motion deblurring. ACM Trans Graphics 2009; 28: 145:1-145:8.
-
(2009)
ACM Trans Graphics
, vol.28
, pp. 1451-1458
-
-
Cho, S.1
Lee, S.2
|