메뉴 건너뛰기




Volumn 62, Issue 2, 2009, Pages 440-449

Motion artifact correction in free-breathing abdominal MRI using overlapping partial samples to recover image deformations

Author keywords

Breathing; Conjugate gradient; Image reconstruction; Liver; Motion correction

Indexed keywords

CONJUGATE GRADIENT METHOD; DEFORMATION; IMAGE RESOLUTION; LIVER; MAGNETIC RESONANCE IMAGING;

EID: 67749133780     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22017     Document Type: Article
Times cited : (21)

References (31)
  • 1
    • 44449097633 scopus 로고    scopus 로고
    • Willatt JM, Hussain HK, Adusumilli S, Marrero JA. MR Imaging of hepatocellular carcinoma in the cirrhotic liver: challenges and controversies. Radiology 2008;247:311-330.
    • Willatt JM, Hussain HK, Adusumilli S, Marrero JA. MR Imaging of hepatocellular carcinoma in the cirrhotic liver: challenges and controversies. Radiology 2008;247:311-330.
  • 3
    • 38349091134 scopus 로고    scopus 로고
    • Post-processing of dynamic gadolinium-enhanced magnetic resonance imaging exams of the liver: Explanation and potential clinical applications for color-coded qualitative and quantitative analysis
    • Wang L, den Bos IC, Hussain SM, and Pattynama PM, Vogel MW, Krestin GP. Post-processing of dynamic gadolinium-enhanced magnetic resonance imaging exams of the liver: explanation and potential clinical applications for color-coded qualitative and quantitative analysis. Acta Radiol 2008;49:6-18.
    • (2008) Acta Radiol , vol.49 , pp. 6-18
    • Wang, L.1    den Bos, I.C.2    Hussain, S.M.3    Pattynama, P.M.4    Vogel, M.W.5    Krestin, G.P.6
  • 4
    • 34547897640 scopus 로고    scopus 로고
    • Image quality and focal lesion detection on T2-weighted MR imaging of the liver: Comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques
    • Lee SS, Byun JH, Hong HS, Park SH, Won HJ, Shin YM, Lee MG. Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques. J Magn Reson Imaging 2007;26:323-330.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 323-330
    • Lee, S.S.1    Byun, J.H.2    Hong, H.S.3    Park, S.H.4    Won, H.J.5    Shin, Y.M.6    Lee, M.G.7
  • 5
    • 1642280997 scopus 로고    scopus 로고
    • Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images
    • Rohlfing T, Maurer CR, O'Dell WG, Zhong J. Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images. Med Phys 2004;31:427-432.
    • (2004) Med Phys , vol.31 , pp. 427-432
    • Rohlfing, T.1    Maurer, C.R.2    O'Dell, W.G.3    Zhong, J.4
  • 7
    • 0039943513 scopus 로고    scopus 로고
    • Paige CC, Saunders MA. LSQR: An algorithm for sparse linear equations and sparse least squares. TOMS 1982;8:43-71.
    • Paige CC, Saunders MA. LSQR: An algorithm for sparse linear equations and sparse least squares. TOMS 1982;8:43-71.
  • 8
    • 84976657333 scopus 로고
    • Algorithm 583; LSQR: Sparse linear equations and least-squares problems
    • Paige CC, Saunders MA, Algorithm 583; LSQR: Sparse linear equations and least-squares problems. TOMS 1982;8:195-209.
    • (1982) TOMS , vol.8 , pp. 195-209
    • Paige, C.C.1    Saunders, M.A.2
  • 12
    • 34249715249 scopus 로고    scopus 로고
    • Dual-component model of respiratory motion based on the periodic autoregressive moving average (periodic ARMA) method
    • McCall KC, Jeraj R. Dual-component model of respiratory motion based on the periodic autoregressive moving average (periodic ARMA) method. Phys Med Biol 2007;52:3455-3466.
    • (2007) Phys Med Biol , vol.52 , pp. 3455-3466
    • McCall, K.C.1    Jeraj, R.2
  • 14
    • 33747623309 scopus 로고    scopus 로고
    • MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning
    • Blackall JM, Ahmad S, Miquel ME, McClelland JR, Landau DB, Hawkes DJ. MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning. Phys Med Biol 2006;51:4147-4169.
    • (2006) Phys Med Biol , vol.51 , pp. 4147-4169
    • Blackall, J.M.1    Ahmad, S.2    Miquel, M.E.3    McClelland, J.R.4    Landau, D.B.5    Hawkes, D.J.6
  • 17
    • 41849129269 scopus 로고    scopus 로고
    • Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging
    • Kellman P, Chefd'hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging. Magn Reson Med 2008;59:771-778.
    • (2008) Magn Reson Med , vol.59 , pp. 771-778
    • Kellman, P.1    Chefd'hotel, C.2    Lorenz, C.H.3    Mancini, C.4    Arai, A.E.5    McVeigh, E.R.6
  • 18
    • 44949166653 scopus 로고    scopus 로고
    • Generalized MRI reconstruction including elastic physiological motion and coil sensitivity encoding
    • Odille F, Cîndea N, Mandry D, Pasquier C, Vuissoz PA, Felblinger J. Generalized MRI reconstruction including elastic physiological motion and coil sensitivity encoding. Magn Reson Med 2008;59:1401-1411.
    • (2008) Magn Reson Med , vol.59 , pp. 1401-1411
    • Odille, F.1    Cîndea, N.2    Mandry, D.3    Pasquier, C.4    Vuissoz, P.A.5    Felblinger, J.6
  • 19
    • 85092120088 scopus 로고    scopus 로고
    • Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free-breathing MRI
    • Forthcoming
    • Odille F, Vuissoz PA, Marie PY, Felblinger J. Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free-breathing MRI. Magn Reson Med. Forthcoming.
    • Magn Reson Med
    • Odille, F.1    Vuissoz, P.A.2    Marie, P.Y.3    Felblinger, J.4
  • 20
    • 27144517439 scopus 로고    scopus 로고
    • Anisotropic multi-scale fluid registration: Evaluation in magnetic resonance breast imaging
    • Crum WR, Tanner C, Hawkes DJ. Anisotropic multi-scale fluid registration: Evaluation in magnetic resonance breast imaging. Phys Med Biol 2005;50:5153-5174.
    • (2005) Phys Med Biol , vol.50 , pp. 5153-5174
    • Crum, W.R.1    Tanner, C.2    Hawkes, D.J.3
  • 23
    • 67749126093 scopus 로고    scopus 로고
    • Galassi M, Davies J, Theiler J, Gough B, Jungman G, Booth M, Rossi F. GNU Scientific Library reference manual, revised 2nd ed. Network Theory Limited / Free Software Foundation; 2006. ISBN 0-9541617-3-4.
    • Galassi M, Davies J, Theiler J, Gough B, Jungman G, Booth M, Rossi F. GNU Scientific Library reference manual, revised 2nd ed. Network Theory Limited / Free Software Foundation; 2006. ISBN 0-9541617-3-4.
  • 24
    • 79551689414 scopus 로고    scopus 로고
    • Methods for inverting dense displacement fields: Evaluation in brain image registration
    • Crum WR, Camara O, Hawkes DJ. Methods for inverting dense displacement fields: evaluation in brain image registration. Med Image Comput Comput Assist Interv Int Conf 2007;10 (Part 1):900-907.
    • (2007) Med Image Comput Comput Assist Interv Int Conf , vol.10 , Issue.PART 1 , pp. 900-907
    • Crum, W.R.1    Camara, O.2    Hawkes, D.J.3
  • 25
    • 26844558803 scopus 로고    scopus 로고
    • Convergence behavior of iterative SENSE reconstruction with non-Cartesian trajectories
    • Qu P, Zhong K, Zhang B, Wang J, Shen GX. Convergence behavior of iterative SENSE reconstruction with non-Cartesian trajectories. Magn Reson Med 2005;54:1040-1045.
    • (2005) Magn Reson Med , vol.54 , pp. 1040-1045
    • Qu, P.1    Zhong, K.2    Zhang, B.3    Wang, J.4    Shen, G.X.5
  • 27
    • 0004148166 scopus 로고    scopus 로고
    • The Objective Caml System release 3.10: Documentation and users manual
    • France: Institute National de Recherche en Informatique et en Automatique INRIA
    • Leroy X, Doligez D, Garrigue J, Rémy D, Vouillon J. The Objective Caml System release 3.10: Documentation and users manual. France: Institute National de Recherche en Informatique et en Automatique (INRIA); 2007.
    • (2007)
    • Leroy, X.1    Doligez, D.2    Garrigue, J.3    Rémy, D.4    Vouillon, J.5
  • 28
    • 2642574503 scopus 로고    scopus 로고
    • R Development Core Team R:, Vienna, Austria: R Foundation for Statistical Computing; ISBN 3-900051-07-0
    • R Development Core Team R: A language and environment for statistical computing. Vienna, Austria: R Foundation for Statistical Computing; ISBN 3-900051-07-0.
    • A language and environment for statistical computing
  • 30
    • 51049092304 scopus 로고    scopus 로고
    • Acceleration and validation of optical flow based deformable registration for image-guided radiotherapy
    • Østergaard Noe K, De Senneville BD, Elstrøm UV, Tanderup K, Sørensen TS. Acceleration and validation of optical flow based deformable registration for image-guided radiotherapy. Acta Oncol 2008;47:1286-1293.
    • (2008) Acta Oncol , vol.47 , pp. 1286-1293
    • Østergaard Noe, K.1    De Senneville, B.D.2    Elstrøm, U.V.3    Tanderup, K.4    Sørensen, T.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.