메뉴 건너뛰기




Volumn 39, Issue 4, 2015, Pages 659-665

Sagittal gap balancing with the concept of a single radius femoral component in posterior cruciate sacrificing total knee arthroplasty with patient-specific instrumentation

Author keywords

Patient specific instrumentation; Sagittal gap balancing; Single radius femoral component; Total knee arthroplasty

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE RECONSTRUCTION; KNEE EXTENSION GAP; KNEE FLEXION GAP; KNEE FUNCTION; KNEE LIGAMENT; KNEE OSTEOARTHRITIS; KNEE PROSTHESIS; KNEE RADIOGRAPHY; MALE; MUSCULOSKELETAL SYSTEM PARAMETERS; OSTEOTOMY; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; TOTAL KNEE REPLACEMENT; DEVICES; JOINT CHARACTERISTICS AND FUNCTIONS; KNEE; KNEE ARTHROPLASTY; MIDDLE AGED; OSTEOARTHRITIS, KNEE; PATELLA; POSTOPERATIVE PERIOD; PROCEDURES; VERY ELDERLY;

EID: 84925543352     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-014-2536-2     Document Type: Article
Times cited : (6)

References (37)
  • 1
    • 0036155739 scopus 로고    scopus 로고
    • Perfect balance in total knee arthroplasty: the elusive compromise
    • COI: 1:STN:280:DC%2BD38%2FnvVOmsw%3D%3D, PID: 11805918
    • Winemaker MJ (2002) Perfect balance in total knee arthroplasty: the elusive compromise. J Arthroplasty 17:2–10
    • (2002) J Arthroplasty , vol.17 , pp. 2-10
    • Winemaker, M.J.1
  • 3
    • 0033638562 scopus 로고    scopus 로고
    • Accuracy of soft tissue balancing in total knee arthroplasty
    • COI: 1:STN:280:DC%2BD3M%2FpsVWiug%3D%3D, PID: 11112189
    • Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15(8):970–973
    • (2000) J Arthroplasty , vol.15 , Issue.8 , pp. 970-973
    • Griffin, F.M.1    Insall, J.N.2    Scuderi, G.R.3
  • 4
    • 0036787787 scopus 로고    scopus 로고
    • Posterior-stabilized versus cruciate-retaining total knee arthroplasty. Balancing the gap
    • PID: 12375237
    • Tanzer M, Smith K, Burnett S (2002) Posterior-stabilized versus cruciate-retaining total knee arthroplasty. Balancing the gap. J Arthroplasty 17:813–819
    • (2002) J Arthroplasty , vol.17 , pp. 813-819
    • Tanzer, M.1    Smith, K.2    Burnett, S.3
  • 5
    • 2642516292 scopus 로고    scopus 로고
    • Femoral component sizing in total knee arthroplasty: size matched resection versus flexion space balancing
    • PID: 15188110
    • Incavo SJ, Coughlin KM, Beynnon BD (2004) Femoral component sizing in total knee arthroplasty: size matched resection versus flexion space balancing. J Arthroplasty 19(4):493–497
    • (2004) J Arthroplasty , vol.19 , Issue.4 , pp. 493-497
    • Incavo, S.J.1    Coughlin, K.M.2    Beynnon, B.D.3
  • 6
    • 62349087363 scopus 로고    scopus 로고
    • Soft tissue balance measurement in posterior-stabilized total knee arthroplasty with a navigation system
    • PID: 18757174
    • Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kurosaka M, Kuroda R (2009) Soft tissue balance measurement in posterior-stabilized total knee arthroplasty with a navigation system. J Arthroplasty 24(3):358–364
    • (2009) J Arthroplasty , vol.24 , Issue.3 , pp. 358-364
    • Matsumoto, T.1    Muratsu, H.2    Tsumura, N.3    Mizuno, K.4    Kurosaka, M.5    Kuroda, R.6
  • 7
    • 77957343709 scopus 로고    scopus 로고
    • Femoral component placement changes soft tissue balance in posterior-stabilized total knee arthroplasty
    • Muratsu H, Matsumoto T, Kubo S, Maruo A, Miya H, Kurosaka M et al (2010) Femoral component placement changes soft tissue balance in posterior-stabilized total knee arthroplasty. Clin Biomech (Bristol, Avon) 25(9):926–930
    • (2010) Clin Biomech (Bristol, Avon) , vol.25 , Issue.9 , pp. 926-930
    • Muratsu, H.1    Matsumoto, T.2    Kubo, S.3    Maruo, A.4    Miya, H.5    Kurosaka, M.6
  • 8
    • 84865395375 scopus 로고    scopus 로고
    • The intraoperative gap difference (flexion gap minus extension gap) is altered by insertion of the trial femoral component
    • PID: 21889347
    • Hananouchi T, Yamamoto K, Ando W, Fudo K, Ohzono K (2012) The intraoperative gap difference (flexion gap minus extension gap) is altered by insertion of the trial femoral component. Knee 19(5):601–605
    • (2012) Knee , vol.19 , Issue.5 , pp. 601-605
    • Hananouchi, T.1    Yamamoto, K.2    Ando, W.3    Fudo, K.4    Ohzono, K.5
  • 9
    • 58149343701 scopus 로고    scopus 로고
    • Patient-specific approach in total knee arthroplasty
    • PID: 18814618
    • Lombardi AVJ, Berend KR, Adams JB (2008) Patient-specific approach in total knee arthroplasty. Orthopedics 31:927–930
    • (2008) Orthopedics , vol.31 , pp. 927-930
    • Lombardi, A.V.J.1    Berend, K.R.2    Adams, J.B.3
  • 10
    • 84870049108 scopus 로고    scopus 로고
    • A review of rapid prototyped surgical guides for patient-specific total knee replacement
    • COI: 1:STN:280:DC%2BC3s%2Fpt1WlsA%3D%3D
    • Krishnan SP, Dawood A, Richards R, Henckel J, Hart AJ (2012) A review of rapid prototyped surgical guides for patient-specific total knee replacement. J Bone Joint Surg (Br) 94:1457–1461
    • (2012) J Bone Joint Surg (Br) , vol.94 , pp. 1457-1461
    • Krishnan, S.P.1    Dawood, A.2    Richards, R.3    Henckel, J.4    Hart, A.J.5
  • 13
    • 38849096978 scopus 로고    scopus 로고
    • CT-based planning of a single-radius femoral component in total knee arthroplasty using the ROBODOC system
    • PID: 18240052
    • Hananouchi T, Nakamura N, Kakimoto A, Yohsikawa H, Sugano N (2008) CT-based planning of a single-radius femoral component in total knee arthroplasty using the ROBODOC system. Comput Aided Surg 13(1):23–29
    • (2008) Comput Aided Surg , vol.13 , Issue.1 , pp. 23-29
    • Hananouchi, T.1    Nakamura, N.2    Kakimoto, A.3    Yohsikawa, H.4    Sugano, N.5
  • 14
    • 84870242556 scopus 로고    scopus 로고
    • The kinematics and stability of single-radius versus multi-radius femoral components related to mid-range instability after TKA
    • PID: 22696446
    • Stoddard JE, Deehan DJ, Bull AM, McCaskie AW, Amis AA (2013) The kinematics and stability of single-radius versus multi-radius femoral components related to mid-range instability after TKA. J Orthop Res 31(1):53–58
    • (2013) J Orthop Res , vol.31 , Issue.1 , pp. 53-58
    • Stoddard, J.E.1    Deehan, D.J.2    Bull, A.M.3    McCaskie, A.W.4    Amis, A.A.5
  • 15
    • 0027400765 scopus 로고
    • Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis
    • PID: 8425366
    • Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47
    • (1993) Clin Orthop Relat Res , vol.286 , pp. 40-47
    • Berger, R.A.1    Rubash, H.E.2    Seel, M.J.3    Thompson, W.H.4    Crossett, L.S.5
  • 17
    • 0034957088 scopus 로고    scopus 로고
    • Relationship between frontal knee alignment and reference axes in the distal femur
    • PID: 11451114
    • Akagi M, Yamashita E, Nakagawa T, Asano T, Nakamura T (2001) Relationship between frontal knee alignment and reference axes in the distal femur. Clin Orthop Relat Res 388:147–156
    • (2001) Clin Orthop Relat Res , vol.388 , pp. 147-156
    • Akagi, M.1    Yamashita, E.2    Nakagawa, T.3    Asano, T.4    Nakamura, T.5
  • 18
    • 84899585684 scopus 로고    scopus 로고
    • Satisfactory results at 8 years mean follow-up after ADVANCE® medial-pivot total knee arthroplasty
    • PID: 24440451
    • Chinzei N, Ishida K, Tsumura N, Matsumoto T, Kitagawa A, Iguchi T et al (2014) Satisfactory results at 8 years mean follow-up after ADVANCE® medial-pivot total knee arthroplasty. Knee 21(2):387–390
    • (2014) Knee , vol.21 , Issue.2 , pp. 387-390
    • Chinzei, N.1    Ishida, K.2    Tsumura, N.3    Matsumoto, T.4    Kitagawa, A.5    Iguchi, T.6
  • 19
    • 79955970934 scopus 로고    scopus 로고
    • Kneeling is safe for patients implanted with medial-pivot total knee arthroplasty designs
    • PID: 20541359
    • Barnes CL, Sharma A, Blaha JD, Nambu SN, Carroll ME (2011) Kneeling is safe for patients implanted with medial-pivot total knee arthroplasty designs. J Arthroplasty 26(4):549–554
    • (2011) J Arthroplasty , vol.26 , Issue.4 , pp. 549-554
    • Barnes, C.L.1    Sharma, A.2    Blaha, J.D.3    Nambu, S.N.4    Carroll, M.E.5
  • 20
    • 77950516822 scopus 로고    scopus 로고
    • Primitive results after medial-pivot knee arthroplasties: a minimum 5-year follow-up study
    • PID: 19577880
    • Fan CY, Hsieh JT, Hsieh MS, Shih YC, Lee CH (2010) Primitive results after medial-pivot knee arthroplasties: a minimum 5-year follow-up study. J Arthroplasty 25(3):492–496
    • (2010) J Arthroplasty , vol.25 , Issue.3 , pp. 492-496
    • Fan, C.Y.1    Hsieh, J.T.2    Hsieh, M.S.3    Shih, Y.C.4    Lee, C.H.5
  • 21
    • 63849122447 scopus 로고    scopus 로고
    • The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement
    • COI: 1:STN:280:DC%2BD1M3kvFCgsg%3D%3D
    • Matsumoto T, Kuroda R, Kubo S, Muratsu H, Mizuno K, Kurosaka M (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement. J Bone Joint Surg (Br) 91(4):475–480
    • (2009) J Bone Joint Surg (Br) , vol.91 , Issue.4 , pp. 475-480
    • Matsumoto, T.1    Kuroda, R.2    Kubo, S.3    Muratsu, H.4    Mizuno, K.5    Kurosaka, M.6
  • 22
    • 79960457080 scopus 로고    scopus 로고
    • Soft tissue tension in cruciate-retaining and posterior-stabilized total knee arthroplasty
    • PID: 20663642
    • Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kurosaka M, Kuroda R (2011) Soft tissue tension in cruciate-retaining and posterior-stabilized total knee arthroplasty. J Arthroplasty 26(5):788–795
    • (2011) J Arthroplasty , vol.26 , Issue.5 , pp. 788-795
    • Matsumoto, T.1    Muratsu, H.2    Kubo, S.3    Matsushita, T.4    Kurosaka, M.5    Kuroda, R.6
  • 23
    • 84866387701 scopus 로고    scopus 로고
    • Intraoperative soft tissue balance reflects minimum 5-year midterm outcomes in cruciate-retaining and posterior-stabilized total knee arthroplasty
    • PID: 22554731
    • Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kurosaka M, Kuroda R (2012) Intraoperative soft tissue balance reflects minimum 5-year midterm outcomes in cruciate-retaining and posterior-stabilized total knee arthroplasty. J Arthroplasty 27(9):1723–1730
    • (2012) J Arthroplasty , vol.27 , Issue.9 , pp. 1723-1730
    • Matsumoto, T.1    Muratsu, H.2    Kubo, S.3    Matsushita, T.4    Kurosaka, M.5    Kuroda, R.6
  • 24
    • 84884533075 scopus 로고    scopus 로고
    • Different pattern in gap balancing between the cruciate-retaining and posterior-stabilized total knee arthroplasty
    • PID: 23322266
    • Matsumoto T, Kubo S, Muratsu H, Matsushita T, Ishida K, Kawakami Y et al (2013) Different pattern in gap balancing between the cruciate-retaining and posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21(10):2338–2345
    • (2013) Knee Surg Sports Traumatol Arthrosc , vol.21 , Issue.10 , pp. 2338-2345
    • Matsumoto, T.1    Kubo, S.2    Muratsu, H.3    Matsushita, T.4    Ishida, K.5    Kawakami, Y.6
  • 25
    • 84898873833 scopus 로고    scopus 로고
    • Soft-tissue balancing in total knee arthroplasty: cruciate-retaining versus posterior-stabilised, and measured-resection versus gap technique
    • PID: 24146174
    • Matsumoto T, Muratsu H, Kawakami Y, Takayama K, Ishida K, Matsushita T et al (2014) Soft-tissue balancing in total knee arthroplasty: cruciate-retaining versus posterior-stabilised, and measured-resection versus gap technique. Int Orthop 38(3):531–537
    • (2014) Int Orthop , vol.38 , Issue.3 , pp. 531-537
    • Matsumoto, T.1    Muratsu, H.2    Kawakami, Y.3    Takayama, K.4    Ishida, K.5    Matsushita, T.6
  • 26
    • 84904474108 scopus 로고    scopus 로고
    • The influence of the tibial slope on intra-operative soft tissue balance in cruciate-retaining and posterior-stabilized total knee arthroplasty
    • PID: 23689963
    • Oka S, Matsumoto T, Muratsu H, Kubo S, Matsushita T, Ishida K et al (2014) The influence of the tibial slope on intra-operative soft tissue balance in cruciate-retaining and posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(8):1812–1818
    • (2014) Knee Surg Sports Traumatol Arthrosc , vol.22 , Issue.8 , pp. 1812-1818
    • Oka, S.1    Matsumoto, T.2    Muratsu, H.3    Kubo, S.4    Matsushita, T.5    Ishida, K.6
  • 27
    • 85027937220 scopus 로고    scopus 로고
    • The influence of patella height on soft tissue balance in cruciate-retaining and posterior-stabilised total knee arthroplasty
    • PID: 23275081
    • Nishizawa Y, Matsumoto T, Kubo S, Muratsu H, Matsushita T, Oka S et al (2013) The influence of patella height on soft tissue balance in cruciate-retaining and posterior-stabilised total knee arthroplasty. Int Orthop 37(3):421–425
    • (2013) Int Orthop , vol.37 , Issue.3 , pp. 421-425
    • Nishizawa, Y.1    Matsumoto, T.2    Kubo, S.3    Muratsu, H.4    Matsushita, T.5    Oka, S.6
  • 28
    • 0032998511 scopus 로고    scopus 로고
    • Posterior cruciate ligament effects on the flexion space in total knee arthroplasty
    • Mihalko WM, Krackow KA (1999) Posterior cruciate ligament effects on the flexion space in total knee arthroplasty. Clin Orthop Relat Res (360):243–250
    • (1999) Clin Orthop Relat Res (360) , pp. 243-250
    • Mihalko, W.M.1    Krackow, K.A.2
  • 29
    • 0034786715 scopus 로고    scopus 로고
    • Effects of posterior cruciate ligament resection on the tibiofemoral joint gap
    • Kadoya Y, Kobayashi A, Komatsu T, Nakagawa S, Yamano Y (2001) Effects of posterior cruciate ligament resection on the tibiofemoral joint gap. Clin Orthop Relat Res (391):210–217
    • (2001) Clin Orthop Relat Res (391) , pp. 210-217
  • 30
    • 73949102715 scopus 로고    scopus 로고
    • Effect of PCL on flexion-extension gaps and femoral component decision in TKA
    • PID: 19835303
    • Park SJ, Seon JK, Park JK, Song EK (2009) Effect of PCL on flexion-extension gaps and femoral component decision in TKA. Orthopedics 32(10 Suppl):22–25
    • (2009) Orthopedics , vol.32 , pp. 22-25
    • Park, S.J.1    Seon, J.K.2    Park, J.K.3    Song, E.K.4
  • 31
    • 77950350305 scopus 로고    scopus 로고
    • Effects of posterior cruciate ligament resection in total knee arthroplasty using computer assisted surgery
    • Chaiyakit P, Meknavin S, Hongku N (2009) Effects of posterior cruciate ligament resection in total knee arthroplasty using computer assisted surgery. J Med Assoc Thai 92 Suppl 6:S80–84
    • (2009) J Med Assoc Thai 92 Suppl , vol.6 , pp. 80-84
    • Chaiyakit, P.1    Meknavin, S.2    Hongku, N.3
  • 32
    • 84899433246 scopus 로고    scopus 로고
    • Flexion-extension gap in cruciate-retaining versus posterior-stabilized total knee arthroplasty: a cadaveric study
    • PID: 24474152
    • Matthews J, Chong A, McQueen D, O’Guinn J, Wooley P (2014) Flexion-extension gap in cruciate-retaining versus posterior-stabilized total knee arthroplasty: a cadaveric study. J Orthop Res 32(5):627–632
    • (2014) J Orthop Res , vol.32 , Issue.5 , pp. 627-632
    • Matthews, J.1    Chong, A.2    McQueen, D.3    O’Guinn, J.4    Wooley, P.5
  • 33
    • 84858795863 scopus 로고    scopus 로고
    • Is the effect of a posterior cruciate ligament resection in total knee arthroplasty predictable?
    • PID: 21706197
    • Schnurr C, Eysel P, König DP (2012) Is the effect of a posterior cruciate ligament resection in total knee arthroplasty predictable? Int Orthop 36(1):83–88
    • (2012) Int Orthop , vol.36 , Issue.1 , pp. 83-88
    • Schnurr, C.1    Eysel, P.2    König, D.P.3
  • 34
    • 84865102501 scopus 로고    scopus 로고
    • Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA
    • PID: 21809150
    • Ng VY, Declaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99–107
    • (2012) Clin Orthop Relat Res , vol.470 , Issue.1 , pp. 99-107
    • Ng, V.Y.1    Declaire, J.H.2    Berend, K.R.3    Gulick, B.C.4    Lombardi, A.V.5
  • 35
    • 84856958576 scopus 로고    scopus 로고
    • Do patient-specific instrumentations improve coronal alignment in total knee arthroplasty?
    • Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific instrumentations improve coronal alignment in total knee arthroplasty? Clin Orthop Relat 470(3):895–902
    • (2012) Clin Orthop Relat , vol.470 , Issue.3 , pp. 895-902
    • Nunley, R.M.1    Ellison, B.S.2    Zhu, J.3    Ruh, E.L.4    Howell, S.M.5    Barrack, R.L.6
  • 36
    • 84891747010 scopus 로고    scopus 로고
    • Patient-specific instrumentations do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial
    • PID: 23616267
    • Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific instrumentations do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res 472(1):263–271
    • (2014) Clin Orthop Relat Res , vol.472 , Issue.1 , pp. 263-271
    • Victor, J.1    Dujardin, J.2    Vandenneucker, H.3    Arnout, N.4    Bellemans, J.5
  • 37
    • 84925539592 scopus 로고    scopus 로고
    • The use of patient-specific intra-operative guides for total knee arthroplasty (TKA)
    • Delport H, Chandrashekar P (2012) The use of patient-specific intra-operative guides for total knee arthroplasty (TKA). Arch Clin Exp Surg 1(4):206–212
    • (2012) Arch Clin Exp Surg , vol.1 , Issue.4 , pp. 206-212
    • Delport, H.1    Chandrashekar, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.