메뉴 건너뛰기




Volumn 861, Issue , 2015, Pages 47-54

Direct drug analysis from oral fluid using medical swab touch spray mass spectrometry

Author keywords

Ambient ionization; Drug testing; Medical swab; Tandem mass spectrometry; Touch spray ionization; Toxicology

Indexed keywords

DATA ACQUISITION; FORENSIC SCIENCE; IONIZATION; MASS SPECTROMETRY; WELL TESTING;

EID: 84925260862     PISSN: 00032670     EISSN: 18734324     Source Type: Journal    
DOI: 10.1016/j.aca.2015.01.008     Document Type: Article
Times cited : (75)

References (50)
  • 1
    • 84876975096 scopus 로고    scopus 로고
    • Determination of pharmaceutical and illicit drugs in oral fluid by ultra-high performance liquid chromatography-tandem mass spectrometry
    • Di Corcia D., Lisi S., Pirro V., Gerace E., Salomone A., Vincenti M. Determination of pharmaceutical and illicit drugs in oral fluid by ultra-high performance liquid chromatography-tandem mass spectrometry. J. Chromatogr. B 2013, 927:133-141.
    • (2013) J. Chromatogr. B , vol.927 , pp. 133-141
    • Di Corcia, D.1    Lisi, S.2    Pirro, V.3    Gerace, E.4    Salomone, A.5    Vincenti, M.6
  • 2
    • 84893459616 scopus 로고    scopus 로고
    • The potential role of oral fluid in antidoping testing
    • Anizan S., Huestis M.A. The potential role of oral fluid in antidoping testing. Clin. Chem. 2014, 60:307-322.
    • (2014) Clin. Chem. , vol.60 , pp. 307-322
    • Anizan, S.1    Huestis, M.A.2
  • 3
    • 84894102880 scopus 로고    scopus 로고
    • Estimation of equivalent cutoff thresholds in blood and oral fluid for drug prevalence studies
    • Gjerde H., Langel K., Favretto D., Verstraete A.G. Estimation of equivalent cutoff thresholds in blood and oral fluid for drug prevalence studies. J. Anal. Toxicol. 2014, 38:92-98.
    • (2014) J. Anal. Toxicol. , vol.38 , pp. 92-98
    • Gjerde, H.1    Langel, K.2    Favretto, D.3    Verstraete, A.G.4
  • 4
    • 79953020485 scopus 로고    scopus 로고
    • Oral fluid and hair in workplace drug testing programs: new technology for immunoassays
    • Moore C. Oral fluid and hair in workplace drug testing programs: new technology for immunoassays. Drug Test. Anal. 2011, 3:166-168.
    • (2011) Drug Test. Anal. , vol.3 , pp. 166-168
    • Moore, C.1
  • 5
    • 70449701839 scopus 로고    scopus 로고
    • Oral fluid testing for drugs of abuse
    • Bosker W.M., Huestis M.A. Oral fluid testing for drugs of abuse. Clin. Chem. 2009, 55:1910-1931.
    • (2009) Clin. Chem. , vol.55 , pp. 1910-1931
    • Bosker, W.M.1    Huestis, M.A.2
  • 7
    • 79956210911 scopus 로고    scopus 로고
    • Guidelines for European workplace drug testing in oral fluid
    • Cooper G., Moore C., George C., Pichini S. Guidelines for European workplace drug testing in oral fluid. Drug Test. Anal. 2011, 3:269-276.
    • (2011) Drug Test. Anal. , vol.3 , pp. 269-276
    • Cooper, G.1    Moore, C.2    George, C.3    Pichini, S.4
  • 8
    • 42049119851 scopus 로고    scopus 로고
    • Introduction and review of collection techniques and applications of drug testing of oral fluid
    • Drummer O.H. Introduction and review of collection techniques and applications of drug testing of oral fluid. Ther. Drug Monit. 2008, 30:203-206.
    • (2008) Ther. Drug Monit. , vol.30 , pp. 203-206
    • Drummer, O.H.1
  • 9
    • 84878809028 scopus 로고    scopus 로고
    • Application of mass spectrometry to hair analysis for forensic toxicological investigations
    • Vincenti M., Salomone A., Gerace E., Pirro V. Application of mass spectrometry to hair analysis for forensic toxicological investigations. Mass Spectrom. Rev. 2013, 32:312-332.
    • (2013) Mass Spectrom. Rev. , vol.32 , pp. 312-332
    • Vincenti, M.1    Salomone, A.2    Gerace, E.3    Pirro, V.4
  • 10
    • 84877125998 scopus 로고    scopus 로고
    • What is the future of (ultra) high performance liquid chromatography coupled to low and high resolution mass spectrometry for toxicological drug screening?
    • Maurer H.H. What is the future of (ultra) high performance liquid chromatography coupled to low and high resolution mass spectrometry for toxicological drug screening?. J. Chromatogr. A 2013, 1292:19-24.
    • (2013) J. Chromatogr. A , vol.1292 , pp. 19-24
    • Maurer, H.H.1
  • 11
    • 84897453813 scopus 로고    scopus 로고
    • Performance evaluation of on-site oral fluid drug screening devices in normal police procedure in Germany
    • Musshoff F., Hokamp E.G., Bott U., Madea B. Performance evaluation of on-site oral fluid drug screening devices in normal police procedure in Germany. Forensic Sci. Int. 2014, 238:120-124.
    • (2014) Forensic Sci. Int. , vol.238 , pp. 120-124
    • Musshoff, F.1    Hokamp, E.G.2    Bott, U.3    Madea, B.4
  • 12
    • 84885806182 scopus 로고    scopus 로고
    • Quantitative measurement of synthetic cathinones in oral fluid
    • Amaratunga P., Lorenz Lemberg B., Lemberg D. Quantitative measurement of synthetic cathinones in oral fluid. J. Anal. Toxicol. 2013, 37:622-628.
    • (2013) J. Anal. Toxicol. , vol.37 , pp. 622-628
    • Amaratunga, P.1    Lorenz Lemberg, B.2    Lemberg, D.3
  • 13
    • 84866042001 scopus 로고    scopus 로고
    • Ultra high performance liquid chromatography-electrospray ionization-tandem mass spectrometry screening method of direct analysis of designer drugs, spice and stimulants in oral fluid
    • Strano-Rossi S., Anzillotti L., Castrignanò E., Romolo F.S., Chiarotti M. Ultra high performance liquid chromatography-electrospray ionization-tandem mass spectrometry screening method of direct analysis of designer drugs, spice and stimulants in oral fluid. J. Chromatogr. A 2012, 1258:37-42.
    • (2012) J. Chromatogr. A , vol.1258 , pp. 37-42
    • Strano-Rossi, S.1    Anzillotti, L.2    Castrignanò, E.3    Romolo, F.S.4    Chiarotti, M.5
  • 14
    • 70449701837 scopus 로고    scopus 로고
    • Simultaneous screening and quantitation of 29 drugs of abuse in oral fluid by solid-phase extraction and ultra performance LC-MS/MS
    • Badawi N., Simonsen K.W., Steentoft A., Bernhoft I.M., Linnet K. Simultaneous screening and quantitation of 29 drugs of abuse in oral fluid by solid-phase extraction and ultra performance LC-MS/MS. Clin. Chem. 2009, 55:2004-2018.
    • (2009) Clin. Chem. , vol.55 , pp. 2004-2018
    • Badawi, N.1    Simonsen, K.W.2    Steentoft, A.3    Bernhoft, I.M.4    Linnet, K.5
  • 15
    • 79953315731 scopus 로고    scopus 로고
    • A validated method for the detection and quantitation of 50 drugs of abuse and medicinal drugs in oral fluid by gas chromatography-mass spectrometry
    • Langel K., Gunnar T., Ariniemi K., Rajamäki O., Lillsunde P. A validated method for the detection and quantitation of 50 drugs of abuse and medicinal drugs in oral fluid by gas chromatography-mass spectrometry. J. Chromatogr. B 2011, 879:859-870.
    • (2011) J. Chromatogr. B , vol.879 , pp. 859-870
    • Langel, K.1    Gunnar, T.2    Ariniemi, K.3    Rajamäki, O.4    Lillsunde, P.5
  • 16
    • 84886783006 scopus 로고    scopus 로고
    • Quantification of selected synthetic cannabinoids and δ9-tetrahydrocannabinol in oral fluid by liquid chromatography-tandem mass spectrometry
    • de Castro A., Piñeiro B., Lendoiro E., Cruz A., López-Rivadulla M. Quantification of selected synthetic cannabinoids and δ9-tetrahydrocannabinol in oral fluid by liquid chromatography-tandem mass spectrometry. J. Chromatogr. A 2013, 1295:99-106.
    • (2013) J. Chromatogr. A , vol.1295 , pp. 99-106
    • de Castro, A.1    Piñeiro, B.2    Lendoiro, E.3    Cruz, A.4    López-Rivadulla, M.5
  • 17
    • 84874696988 scopus 로고    scopus 로고
    • Mass spectrometry made easy: the quest for simplicity
    • Schwab N.V., Eberlin M.N. Mass spectrometry made easy: the quest for simplicity. Drug Test. Anal. 2013, 5:137-144.
    • (2013) Drug Test. Anal. , vol.5 , pp. 137-144
    • Schwab, N.V.1    Eberlin, M.N.2
  • 18
    • 84896505746 scopus 로고    scopus 로고
    • Mini 12, miniature mass spectrometer for clinical and other applications. Introduction and characterization
    • Li L., Chen T.C., Ren Y., Hendricks P.I., Cooks R.G., Ouyang Z. Mini 12, miniature mass spectrometer for clinical and other applications. Introduction and characterization. Anal. Chem. 2014, 86:2909-2916.
    • (2014) Anal. Chem. , vol.86 , pp. 2909-2916
    • Li, L.1    Chen, T.C.2    Ren, Y.3    Hendricks, P.I.4    Cooks, R.G.5    Ouyang, Z.6
  • 20
    • 78651322735 scopus 로고    scopus 로고
    • New ionization methods and miniature mass spectrometers for biomedicine: DESI imaging for cancer diagnostics and paper spray ionization for therapeutic drug monitoring
    • Cooks R.G., Manicke N.E., Dill A.L., Ifa D.R., Eberlin L.S., Costa A.B., Wang H., Huang G., Ouyang Z. New ionization methods and miniature mass spectrometers for biomedicine: DESI imaging for cancer diagnostics and paper spray ionization for therapeutic drug monitoring. Faraday Discuss. 2011, 149:247-267.
    • (2011) Faraday Discuss. , vol.149 , pp. 247-267
    • Cooks, R.G.1    Manicke, N.E.2    Dill, A.L.3    Ifa, D.R.4    Eberlin, L.S.5    Costa, A.B.6    Wang, H.7    Huang, G.8    Ouyang, Z.9
  • 21
    • 84899847773 scopus 로고    scopus 로고
    • Touch spray mass spectrometry for in situ analysis of complex samples
    • Kerian K.S., Jarmusch A.K., Cooks R.G. Touch spray mass spectrometry for in situ analysis of complex samples. Analyst 2014, 139:2714-2720.
    • (2014) Analyst , vol.139 , pp. 2714-2720
    • Kerian, K.S.1    Jarmusch, A.K.2    Cooks, R.G.3
  • 23
    • 83655192577 scopus 로고    scopus 로고
    • Biological tissue diagnosis using needle biopsy and spray ionization mass spectrometry
    • Liu J., Cooks R.G., Ouyang Z. Biological tissue diagnosis using needle biopsy and spray ionization mass spectrometry. Anal. Chem. 2011, 83:9221-9225.
    • (2011) Anal. Chem. , vol.83 , pp. 9221-9225
    • Liu, J.1    Cooks, R.G.2    Ouyang, Z.3
  • 24
    • 80155134164 scopus 로고    scopus 로고
    • Electrospray ionization using wooden tips
    • Hu B., So P.K., Chen H., Yao Z.P. Electrospray ionization using wooden tips. Anal. Chem. 2011, 83:8201-8207.
    • (2011) Anal. Chem. , vol.83 , pp. 8201-8207
    • Hu, B.1    So, P.K.2    Chen, H.3    Yao, Z.P.4
  • 26
    • 84883237410 scopus 로고    scopus 로고
    • Rapid detection and quantitation of ketamine and norketamine in urine and oral fluid by wooden-tip electrospray ionization mass spectrometry
    • So P.K., Ng T.T., Wang H., Hu B., Yao Z.P. Rapid detection and quantitation of ketamine and norketamine in urine and oral fluid by wooden-tip electrospray ionization mass spectrometry. Analyst 2013, 138:2239-2243.
    • (2013) Analyst , vol.138 , pp. 2239-2243
    • So, P.K.1    Ng, T.T.2    Wang, H.3    Hu, B.4    Yao, Z.P.5
  • 27
    • 84883212863 scopus 로고    scopus 로고
    • Direct detection of trace level illicit drugs in human body fluids by probe electrospray ionization mass spectrometry (PESI-MS)
    • Saha S., Mandal M.K., Hiraoka K. Direct detection of trace level illicit drugs in human body fluids by probe electrospray ionization mass spectrometry (PESI-MS). Anal. Methods 2013, 5:4731-4738.
    • (2013) Anal. Methods , vol.5 , pp. 4731-4738
    • Saha, S.1    Mandal, M.K.2    Hiraoka, K.3
  • 28
    • 80052672953 scopus 로고    scopus 로고
    • Quantitative analysis of therapeutic drug in dried blood spot samples by paper spray mass spectrometry: an avenue to therapeutic drug monitoring
    • Manicke N.E., Abu-Rabie P., Spooner N., Ouyang Z., Cooks R.G. Quantitative analysis of therapeutic drug in dried blood spot samples by paper spray mass spectrometry: an avenue to therapeutic drug monitoring. J. Am. Soc. Mass Spectrom. 2011, 22:1501-1507.
    • (2011) J. Am. Soc. Mass Spectrom. , vol.22 , pp. 1501-1507
    • Manicke, N.E.1    Abu-Rabie, P.2    Spooner, N.3    Ouyang, Z.4    Cooks, R.G.5
  • 29
    • 84905714931 scopus 로고    scopus 로고
    • Paper spray and extraction spray mass spectrometry for the direct and simultaneous quantification of eight drugs of abuse in whole blood
    • Espy R.D., Teunissen S.F., Manicke N.E., Ren Y., Ouyang Z., van Asten A., Cooks R.G. Paper spray and extraction spray mass spectrometry for the direct and simultaneous quantification of eight drugs of abuse in whole blood. Anal. Chem. 2014, 86:7712-7718.
    • (2014) Anal. Chem. , vol.86 , pp. 7712-7718
    • Espy, R.D.1    Teunissen, S.F.2    Manicke, N.E.3    Ren, Y.4    Ouyang, Z.5    van Asten, A.6    Cooks, R.G.7
  • 30
    • 84906664114 scopus 로고    scopus 로고
    • Detection of strep throat causing bacterium directly from medical swabs by touch spray-mass spectrometry
    • Jarmusch A.K., Pirro V., Kerian K.S., Cooks R.G. Detection of strep throat causing bacterium directly from medical swabs by touch spray-mass spectrometry. Analyst 2014, 139:4785-4789.
    • (2014) Analyst , vol.139 , pp. 4785-4789
    • Jarmusch, A.K.1    Pirro, V.2    Kerian, K.S.3    Cooks, R.G.4
  • 31
    • 84925250861 scopus 로고    scopus 로고
    • Linee guida per le strutture dotate di laboratori per gli accertamenti di sostanze d'abuso con finalita tossicologico-forensi e medico-legali, 2012 (accessed 03.06.13)
    • GTFI, Linee guida per le strutture dotate di laboratori per gli accertamenti di sostanze d'abuso con finalita tossicologico-forensi e medico-legali, 2012 (accessed 03.06.13). http://tossicologia-forense.unina2.it/dwn/LINEEGUIDA%20-%20REV.3_2010.pdf.
  • 32
    • 84925250860 scopus 로고    scopus 로고
    • implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results (2002).
    • Commission Decision 2002/657/EC of 12 August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results (2002).
    • (2002)
  • 33
    • 0025482937 scopus 로고
    • Systematic delineation of scan modes in multidimensional mass spectrometry
    • Schwartz J.C., Wade A.P., Enke C.G., Cooks R.G. Systematic delineation of scan modes in multidimensional mass spectrometry. Anal. Chem. 1990, 62:1809-1818.
    • (1990) Anal. Chem. , vol.62 , pp. 1809-1818
    • Schwartz, J.C.1    Wade, A.P.2    Enke, C.G.3    Cooks, R.G.4
  • 35
    • 84925276093 scopus 로고    scopus 로고
    • Application note. Data-Dependent™ Neutral-Loss Mass Spectrometry for the Identification of Protein Phosphorylation. (accessed 25.09.14)
    • Thermo. Application note. Data-Dependent™ Neutral-Loss Mass Spectrometry for the Identification of Protein Phosphorylation. (accessed 25.09.14). http://www.thermoscientific.com/content/dam/tfs/ATG/CMD/cmd-support/ltq-xl/scientific-resources/application-notes/App-Note-332-Data-Dependent-Neutral-Loss-Mass-Spectrometry-for-the-Identification-of-Protein-Phosphorylation.pdf.
  • 36
    • 84878313326 scopus 로고    scopus 로고
    • Improved detection of drugs of abuse using high-performance ion mobility spectrometry with electrospray ionization (ESI-HPIMS) for urine matrices
    • Midey A.J., Patel A., Moraff C., Krueger C.A., Wu C. Improved detection of drugs of abuse using high-performance ion mobility spectrometry with electrospray ionization (ESI-HPIMS) for urine matrices. Talanta 2013, 116:77-83.
    • (2013) Talanta , vol.116 , pp. 77-83
    • Midey, A.J.1    Patel, A.2    Moraff, C.3    Krueger, C.A.4    Wu, C.5
  • 38
    • 79952440270 scopus 로고    scopus 로고
    • Reliability of ion mobility spectrometry for the qualitative analysis of complex, multicomponent illicit drug samples
    • Verkouteren J.R., Staymates J.L. Reliability of ion mobility spectrometry for the qualitative analysis of complex, multicomponent illicit drug samples. Forensic Sci. Int. 2011, 206:190-196.
    • (2011) Forensic Sci. Int. , vol.206 , pp. 190-196
    • Verkouteren, J.R.1    Staymates, J.L.2
  • 39
    • 47249153321 scopus 로고    scopus 로고
    • Mass spectrometric analysis of illicit drugs in wastewater and surface water
    • Castiglioni E., Zuccato C., Chiabrando R., Fanelli R. Mass spectrometric analysis of illicit drugs in wastewater and surface water. Mass Spectrom. Rev. 2008, 27:378-394.
    • (2008) Mass Spectrom. Rev. , vol.27 , pp. 378-394
    • Castiglioni, E.1    Zuccato, C.2    Chiabrando, R.3    Fanelli, R.4
  • 40
    • 80052818083 scopus 로고    scopus 로고
    • Fragmentation pathways of drugs of abuse and their metabolites based on QTOF MS/MS and MS(E) accurate-mass spectra
    • Bijlsma L., Sancho J.V., Hernández F., Niessen W.M. Fragmentation pathways of drugs of abuse and their metabolites based on QTOF MS/MS and MS(E) accurate-mass spectra. J. Mass Spectrom. 2011, 46:865-875.
    • (2011) J. Mass Spectrom. , vol.46 , pp. 865-875
    • Bijlsma, L.1    Sancho, J.V.2    Hernández, F.3    Niessen, W.M.4
  • 41
    • 79960332447 scopus 로고    scopus 로고
    • Selection of an immunoassay screening cutoff concentration for opioids in oral fluid
    • Garnier M., Coulter C., Moore C. Selection of an immunoassay screening cutoff concentration for opioids in oral fluid. J. Anal. Toxicol. 2011, 35:369-374.
    • (2011) J. Anal. Toxicol. , vol.35 , pp. 369-374
    • Garnier, M.1    Coulter, C.2    Moore, C.3
  • 42
    • 77749341053 scopus 로고    scopus 로고
    • Roche DAT immunoassay: sensitivity and specificity testing for amphetamines, cocaine, and opiates in oral fluid
    • Crooks C.R., Brown S. Roche DAT immunoassay: sensitivity and specificity testing for amphetamines, cocaine, and opiates in oral fluid. J. Anal. Toxicol. 2010, 34:103-109.
    • (2010) J. Anal. Toxicol. , vol.34 , pp. 103-109
    • Crooks, C.R.1    Brown, S.2
  • 43
    • 84867012103 scopus 로고    scopus 로고
    • More reliable on-site detection of cannabis in oral fluid
    • Verstraete A.G. More reliable on-site detection of cannabis in oral fluid. Clin. Chem. 2012, 58:1389-1391.
    • (2012) Clin. Chem. , vol.58 , pp. 1389-1391
    • Verstraete, A.G.1
  • 44
    • 84889874485 scopus 로고    scopus 로고
    • Oral fluid cannabinoids in chronic cannabis smokers during oral δ9-tetrahydrocannabinoltherapy and smoked cannabis challenge
    • Lee D., Vandrey R., Mendu D.R., Anizan S., Milman G., Murray J.A., Barnes A.J., Huestis M.A. Oral fluid cannabinoids in chronic cannabis smokers during oral δ9-tetrahydrocannabinoltherapy and smoked cannabis challenge. Clin. Chem. 2013, 59:1770-1779.
    • (2013) Clin. Chem. , vol.59 , pp. 1770-1779
    • Lee, D.1    Vandrey, R.2    Mendu, D.R.3    Anizan, S.4    Milman, G.5    Murray, J.A.6    Barnes, A.J.7    Huestis, M.A.8
  • 45
    • 84871479375 scopus 로고    scopus 로고
    • Chemical Reagents and Derivatization Procedures in Drug Analysis in Encyclopedia of Analytical Chemistry
    • in: R.A. Meyers (ed.)
    • N.D. Danielson, P.A., Gallagher, J.J. Bao. Chemical Reagents and Derivatization Procedures in Drug Analysis in Encyclopedia of Analytical Chemistry. in: R.A. Meyers (ed.) (2008) pp 7042-7076.
    • (2008) , pp. 7042-7076
    • Danielson, N.D.1    Gallagher, P.A.2    Bao, J.J.3
  • 46
    • 84899854550 scopus 로고    scopus 로고
    • Beyond the flask: Reactions on the fly in ambient mass spectrometry
    • Espy R.D., Wleklinski M., Yan X., Cooks R.G. Beyond the flask: Reactions on the fly in ambient mass spectrometry. Trends Anal. Chem. 2014, 57:135-146.
    • (2014) Trends Anal. Chem. , vol.57 , pp. 135-146
    • Espy, R.D.1    Wleklinski, M.2    Yan, X.3    Cooks, R.G.4
  • 47
    • 33750686965 scopus 로고    scopus 로고
    • The Hortwitz ratio (HorRat): a useful index of method performance with respect to precision
    • Hortwitz W., Albert R.J. The Hortwitz ratio (HorRat): a useful index of method performance with respect to precision. Assoc. Off. Anal. Chem. 2006, 89:1095-1109.
    • (2006) Assoc. Off. Anal. Chem. , vol.89 , pp. 1095-1109
    • Hortwitz, W.1    Albert, R.J.2
  • 48
    • 84893775554 scopus 로고    scopus 로고
    • Evaluation of commercial multi-drug oral fluid devices to identify 39 new amphetamine-designer drugs
    • Nieddu M., Burrai L., Trignano C., Boatto G. Evaluation of commercial multi-drug oral fluid devices to identify 39 new amphetamine-designer drugs. Leg. Med. (Tokyo) 2014, 16:106-109.
    • (2014) Leg. Med. (Tokyo) , vol.16 , pp. 106-109
    • Nieddu, M.1    Burrai, L.2    Trignano, C.3    Boatto, G.4
  • 49
    • 84883011706 scopus 로고    scopus 로고
    • Validation of a novel immunoassay for the detection of synthetic cannabinoids and metabolites in urine specimens
    • Arntson A., Ofsa B., Lancaster D., Simon J.R., McMullin M., Logan B. Validation of a novel immunoassay for the detection of synthetic cannabinoids and metabolites in urine specimens. J. Anal. Toxicol. 2013, 37:284-290.
    • (2013) J. Anal. Toxicol. , vol.37 , pp. 284-290
    • Arntson, A.1    Ofsa, B.2    Lancaster, D.3    Simon, J.R.4    McMullin, M.5    Logan, B.6
  • 50
    • 84901593842 scopus 로고    scopus 로고
    • LC-QTOF-MS as a superior strategy to immunoassay for the comprehensive analysis of synthetic cannabinoids in urine
    • Kronstrand R., Brinkhagen L., Birath-Karlsson C., Roman M., Josefsson M. LC-QTOF-MS as a superior strategy to immunoassay for the comprehensive analysis of synthetic cannabinoids in urine. Anal. Bioanal. Chem. 2014, 406:3599-3609.
    • (2014) Anal. Bioanal. Chem. , vol.406 , pp. 3599-3609
    • Kronstrand, R.1    Brinkhagen, L.2    Birath-Karlsson, C.3    Roman, M.4    Josefsson, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.