메뉴 건너뛰기




Volumn 68, Issue 4, 2015, Pages 258-264

Historical perspectives in clinical pathology: A history of glucose measurement

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; GLUCOSE DEHYDROGENASE; GLUCOSE HEXOKINASE; GLUCOSE OXIDASE; HEXOKINASE; UNCLASSIFIED DRUG; BIOLOGICAL MARKER; GLUCOSE BLOOD LEVEL; TEST STRIP;

EID: 84925014056     PISSN: 00219746     EISSN: 14724146     Source Type: Journal    
DOI: 10.1136/jclinpath-2014-202672     Document Type: Review
Times cited : (36)

References (63)
  • 1
    • 80051566008 scopus 로고    scopus 로고
    • History of diabetes: From ants to analogs
    • Das AK, Shah S. History of diabetes: from ants to analogs. J Assoc Physicians India 2011;59(Suppl):6-7.
    • (2011) J Assoc Physicians India , vol.59 , pp. 6-7
    • Das, A.K.1    Shah, S.2
  • 2
    • 84944657920 scopus 로고
    • Matthew Dobson (1735?-1784) clinical investigator of diabetes mellitus
    • No authors listed
    • [No authors listed]. Matthew Dobson (1735?-1784) clinical investigator of diabetes mellitus. JAMA 1968;205:698.
    • (1968) JAMA , vol.205 , pp. 698
  • 3
    • 84892278890 scopus 로고    scopus 로고
    • The main events in the history of diabetes mellitus
    • Poretsky L, ed. edn. New York: Springer
    • nd edition edn. New York: Springer, 2010:3-16.
    • (2010) nd Edition , pp. 3-16
    • Zajac, J.1    Shrestha, A.2    Patel, P.3
  • 4
    • 84924947277 scopus 로고    scopus 로고
    • History to 1900
    • 1104085132 rev. no. 28. ed
    • Gale EAM. History to 1900. Diapedia 1104085132 rev. no. 28. ed, 2013.
    • (2013) Diapedia
    • Gale, E.A.M.1
  • 5
    • 84865182208 scopus 로고    scopus 로고
    • A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
    • Clarke SF, Foster JR. A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. Br J Biomed Sci 2012;69:83-93.
    • (2012) Br J Biomed Sci , vol.69 , pp. 83-93
    • Clarke, S.F.1    Foster, J.R.2
  • 6
    • 0041941579 scopus 로고    scopus 로고
    • A note from history: Discovery of the cerebrospinal fluid
    • Hajdu SI. A note from history: discovery of the cerebrospinal fluid. Ann Clin Lab Sci 2003;33:334-6.
    • (2003) Ann Clin Lab Sci , vol.33 , pp. 334-336
    • Hajdu, S.I.1
  • 8
    • 0001515314 scopus 로고
    • Unterscheidung von Gummin, Dextrin, Traubensucker und Rohrzucker
    • Trommer CA. Unterscheidung von Gummin, Dextrin, Traubensucker und Rohrzucker. Annalen der Chemie und Pharmacie 1841;39:360-2.
    • (1841) Annalen der Chemie und Pharmacie , vol.39 , pp. 360-362
    • Trommer, C.A.1
  • 9
    • 0010233167 scopus 로고
    • Die quantitative Bestimmung von Zucker und Stärkmehl mittelst Kupfervitriol
    • Fehling H. Die quantitative Bestimmung von Zucker und Stärkmehl mittelst Kupfervitriol. Annalen der Chemie und Pharmacie 1848;72:106-13.
    • (1848) Annalen der Chemie und Pharmacie , vol.72 , pp. 106-113
    • Fehling, H.1
  • 10
    • 84924947276 scopus 로고
    • Sur un nouveau réactif pour distinguer la présence du sucre dans certains liquides
    • Maumené EJ. Sur un nouveau réactif pour distinguer la présence du sucre dans certains liquides. J Pharm 1850;17:368-70.
    • (1850) J Pharm , vol.17 , pp. 368-370
    • Maumené, E.J.1
  • 11
    • 2642579686 scopus 로고
    • A reagent for the detection of reducing sugars
    • Benedict SR. A reagent for the detection of reducing sugars. J Biol Chem 1909;5:485-7.
    • (1909) J Biol Chem , vol.5 , pp. 485-487
    • Benedict, S.R.1
  • 12
    • 0002430339 scopus 로고
    • A System of Blood Analysis
    • Folin O, Wu H. A System of Blood Analysis. J Biol Chem 1919;38:81-110.
    • (1919) J Biol Chem , vol.38 , pp. 81-110
    • Folin, O.1    Wu, H.2
  • 13
    • 0000674033 scopus 로고
    • A photometric adaptation of the Somogyi method for the determination of glucose
    • Nelson N. A photometric adaptation of the Somogyi method for the determination of glucose. J Biol Chem 1944;153:375-80.
    • (1944) J Biol Chem , vol.153 , pp. 375-380
    • Nelson, N.1
  • 14
    • 0023241377 scopus 로고
    • Review of drug interference with urine glucose tests
    • Rotblatt MD, Koda-Kimble MA. Review of drug interference with urine glucose tests. Diabetes Care 1987;10:103-10.
    • (1987) Diabetes Care , vol.10 , pp. 103-110
    • Rotblatt, M.D.1    Koda-Kimble, M.A.2
  • 15
    • 0014513465 scopus 로고
    • An improved proceure for blood glucose determination with o-toluidine
    • Ceriotti G, De Nadai Frank A. An improved proceure for blood glucose determination with o-toluidine. Clin Chim Acta 1969;24:311-13.
    • (1969) Clin Chim Acta , vol.24 , pp. 311-313
    • Ceriotti, G.1    De Nadai Frank, A.2
  • 16
    • 0004090864 scopus 로고
    • Development and evaluation of a hexokinase/glucose-6-phosphate dehydrogenase procedure for use as a national glucose reference method
    • No. (CDC) 77-8330. Atlanta: Centers for Disease Control
    • Neese JWD, Duncan P, Bayse D. Development and evaluation of a hexokinase/glucose-6-phosphate dehydrogenase procedure for use as a national glucose reference method. HEW Publication No. (CDC) 77-8330. Atlanta: Centers for Disease Control, 1976.
    • (1976) HEW Publication
    • Neese, J.W.D.1    Duncan, P.2    Bayse, D.3
  • 17
    • 85116949751 scopus 로고    scopus 로고
    • Carbohydrates
    • Burtis CA, Ashwood ER, Bruns D, eds. St Louis, Missouri: Saunders Elsevier
    • th edn. St Louis, Missouri: Saunders Elsevier, 2008:389-93.
    • (2008) th Edn. , pp. 389-393
    • Sacks, D.B.1
  • 18
    • 0014201817 scopus 로고
    • Reagentless substrate analysis with immobilized enzymes
    • Updike SJ, Hicks GP. Reagentless substrate analysis with immobilized enzymes. Science 1967;158:270-2.
    • (1967) Science , vol.158 , pp. 270-272
    • Updike, S.J.1    Hicks, G.P.2
  • 19
    • 0014191637 scopus 로고
    • The enzyme electrode
    • Updike SJ, Hicks GP. The enzyme electrode. Nature 1967;214:986-8.
    • (1967) Nature , vol.214 , pp. 986-988
    • Updike, S.J.1    Hicks, G.P.2
  • 20
    • 77953494285 scopus 로고    scopus 로고
    • Glucose biosensors: An overview of use in clinical practice
    • Yoo EH, Lee SY. Glucose biosensors: an overview of use in clinical practice. Sensors (Basel) 2010;10:4558-76.
    • (2010) Sensors (Basel) , vol.10 , pp. 4558-4576
    • Yoo, E.H.1    Lee, S.Y.2
  • 21
    • 50549116480 scopus 로고
    • On bedside urinary tests: Detection of sugar in the urine by means of test papers
    • Oliver G. On bedside urinary tests: detection of sugar in the urine by means of test papers. Lancet 1883;121:858-60.
    • (1883) Lancet , vol.121 , pp. 858-860
    • Oliver, G.1
  • 22
    • 0013503696 scopus 로고
    • Studien iiber ein neues Enzym Glykoseoxydase
    • Muller D. Studien iiber ein neues Enzym Glykoseoxydase. Biochem Z 1928;199:136-70.
    • (1928) Biochem Z , vol.199 , pp. 136-170
    • Muller, D.1
  • 23
    • 0021451910 scopus 로고
    • Self testing, an emerging component of clinical chemistry
    • Free AH, Free HM. Self testing, an emerging component of clinical chemistry. Clin Chem 1984;30:829-38.
    • (1984) Clin Chem , vol.30 , pp. 829-838
    • Free, A.H.1    Free, H.M.2
  • 24
    • 26344455524 scopus 로고
    • Semiquantitative specific test paper for glucose in urine
    • Comer. Semiquantitative specific test paper for glucose in urine. Anal Chem 1956;28:1748-50.
    • (1956) Anal Chem , vol.28 , pp. 1748-1750
    • Comer1
  • 25
    • 0347377751 scopus 로고
    • Simple specific test for urine glucose
    • Free AH, Adams EC, Kercher ML, et al. Simple specific test for urine glucose. Clin Chem 1957;3:163-8.
    • (1957) Clin Chem , vol.3 , pp. 163-168
    • Free, A.H.1    Adams, E.C.2    Kercher, M.L.3
  • 27
    • 84924975089 scopus 로고    scopus 로고
    • Innovations in participatory medicine: The advent of do-it-yourself blood glucose monitoring
    • Frost J. Innovations in participatory medicine: the advent of do-it-yourself blood glucose monitoring. J Participat Med 2010;2:e7.
    • (2010) J Participat Med , vol.2 , pp. e7
    • Frost, J.1
  • 28
    • 77954230653 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose with a focus on analytical quality: An overview
    • Kristensen GB, Sandberg S. Self-monitoring of blood glucose with a focus on analytical quality: an overview. Clin Chem Lab Med 2010;48:963-72.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 963-972
    • Kristensen, G.B.1    Sandberg, S.2
  • 29
    • 25444456037 scopus 로고
    • A rapid method of estimating blood-glucose ranges
    • Kohn J. A rapid method of estimating blood-glucose ranges. Lancet 1957;273:119-21.
    • (1957) Lancet , vol.273 , pp. 119-121
    • Kohn, J.1
  • 30
    • 0348023805 scopus 로고
    • Rapid colorimetric micro-method for estimating glucose in blood and C. S. F. using glucose oxidase
    • Middleton JE, Griffiths WJ. Rapid colorimetric micro-method for estimating glucose in blood and C. S. F. using glucose oxidase. BMJ 1957;2:1525-7.
    • (1957) BMJ , vol.2 , pp. 1525-1527
    • Middleton, J.E.1    Griffiths, W.J.2
  • 31
    • 0029007137 scopus 로고
    • Rapid diagnosis of bacterial meningitis with reagent strips
    • Moosa AA, Quortum HA, Ibrahim MD. Rapid diagnosis of bacterial meningitis with reagent strips. Lancet 1995;345:1290-1.
    • (1995) Lancet , vol.345 , pp. 1290-1291
    • Moosa, A.A.1    Quortum, H.A.2    Ibrahim, M.D.3
  • 32
    • 0016248751 scopus 로고
    • A rapid and simple blood sugar determination using the Ames reflectance meter and Dextrostix system: A preliminary report
    • Cheah JS, Wong AF. A rapid and simple blood sugar determination using the Ames reflectance meter and Dextrostix system: a preliminary report. Singapore Med J 1974;15:51-2.
    • (1974) Singapore Med J , vol.15 , pp. 51-52
    • Cheah, J.S.1    Wong, A.F.2
  • 33
    • 84857419797 scopus 로고    scopus 로고
    • Historical achievements of self-monitoring of blood glucose technology development in Japan
    • Yamada S. Historical achievements of self-monitoring of blood glucose technology development in Japan. J Diabetes Sci Technol 2011;5:1300-6.
    • (2011) J Diabetes Sci Technol , vol.5 , pp. 1300-1306
    • Yamada, S.1
  • 34
    • 0019070626 scopus 로고
    • Calibration of the Dextrometer/Dextrostix system for the assay of whole blood glucose
    • Stewart TC. Calibration of the Dextrometer/Dextrostix system for the assay of whole blood glucose. Clin Chem 1980;26:1622-3.
    • (1980) Clin Chem , vol.26 , pp. 1622-1623
    • Stewart, T.C.1
  • 35
    • 0020693947 scopus 로고
    • Statistical comparison of blood glucose as determined by several test-strip procedures and by a hexokinase procedure
    • Stewart TC, Kleyle RM. Statistical comparison of blood glucose as determined by several test-strip procedures and by a hexokinase procedure. Clin Chem 1983;29:132-5.
    • (1983) Clin Chem , vol.29 , pp. 132-135
    • Stewart, T.C.1    Kleyle, R.M.2
  • 36
    • 0022883359 scopus 로고
    • Laboratory assessment of three new monitors of blood glucose: Accu-Chek II, Glucometer II, and Glucoscan 2000
    • Brooks KE, Rawal N, Henderson AR. Laboratory assessment of three new monitors of blood glucose: Accu-Chek II, Glucometer II, and Glucoscan 2000. Clin Chem 1986;32:2195-200.
    • (1986) Clin Chem , vol.32 , pp. 2195-2200
    • Brooks, K.E.1    Rawal, N.2    Henderson, A.R.3
  • 37
    • 0021268816 scopus 로고
    • A laboratory trial of two new blood-glucose reflectance meters featuring automatic external calibration
    • Walford S, Home PD, Alberti KG. A laboratory trial of two new blood-glucose reflectance meters featuring automatic external calibration. Ann Clin Biochem 1984;21(Pt 2):116-19.
    • (1984) Ann Clin Biochem , vol.21 , Issue.2 , pp. 116-119
    • Walford, S.1    Home, P.D.2    Alberti, K.G.3
  • 38
    • 0023513555 scopus 로고
    • Screening for diabetes mellitus in general practice using a reflectance meter system. The Islington Diabetes Survey
    • Forrest RD, Jackson CA, Yudkin JS. Screening for diabetes mellitus in general practice using a reflectance meter system. The Islington Diabetes Survey. Diabetes Res 1987;6:119-22.
    • (1987) Diabetes Res , vol.6 , pp. 119-122
    • Forrest, R.D.1    Jackson, C.A.2    Yudkin, J.S.3
  • 39
    • 0027143423 scopus 로고
    • Laboratory assessment of five glucose meters designed for self-monitoring of blood glucose concentration
    • Devreese K, Leroux-Roels G. Laboratory assessment of five glucose meters designed for self-monitoring of blood glucose concentration. Eur J Clin Chem Clin Biochem 1993;31:829-37.
    • (1993) Eur J Clin Chem Clin Biochem , vol.31 , pp. 829-837
    • Devreese, K.1    Leroux-Roels, G.2
  • 40
    • 0023239559 scopus 로고
    • Consensus statement on self-monitoring of blood glucose
    • ADA. Consensus statement on self-monitoring of blood glucose. Diabetes Care 1987;10:95-9.
    • (1987) Diabetes Care , vol.10 , pp. 95-99
    • ADA1
  • 41
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke WL, Cox D, Gonder-Frederick LA, et al. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987;10:622-8.
    • (1987) Diabetes Care , vol.10 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3
  • 42
    • 0025605004 scopus 로고
    • Short-term evaluation of an electro-chemical system (ExacTech) for blood glucose monitoring
    • Ross D, Heinemann L, Chantelau EA. Short-term evaluation of an electro-chemical system (ExacTech) for blood glucose monitoring. Diabetes Res Clin Pract 1990;10:281-5.
    • (1990) Diabetes Res Clin Pract , vol.10 , pp. 281-285
    • Ross, D.1    Heinemann, L.2    Chantelau, E.A.3
  • 43
    • 0023714852 scopus 로고
    • New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose
    • Koschinsky T, Dannehl K, Gries FA. New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose. Diabetes Care 1988;11:619-29.
    • (1988) Diabetes Care , vol.11 , pp. 619-629
    • Koschinsky, T.1    Dannehl, K.2    Gries, F.A.3
  • 44
    • 0023883950 scopus 로고
    • An evaluation and comparison of Reflolux II and Glucometer II, two new portable reflectance meters for capillary blood glucose determination
    • Schier GM, Moses RG, Gan IE, et al. An evaluation and comparison of Reflolux II and Glucometer II, two new portable reflectance meters for capillary blood glucose determination. Diabetes Res Clin Pract 1988;4:177-81.
    • (1988) Diabetes Res Clin Pract , vol.4 , pp. 177-181
    • Schier, G.M.1    Moses, R.G.2    Gan, I.E.3
  • 45
    • 0026779446 scopus 로고
    • HemoCue: Evaluation of a portable photometric system for determining glucose in whole blood
    • Ashworth L, Gibb I, Alberti KG. HemoCue: evaluation of a portable photometric system for determining glucose in whole blood. Clin Chem 1992;38(8 Pt 1):1479-82.
    • (1992) Clin Chem , vol.38 , Issue.8 , pp. 1479-1482
    • Ashworth, L.1    Gibb, I.2    Alberti, K.G.3
  • 46
    • 0029856217 scopus 로고    scopus 로고
    • Accuracy of home blood glucose meters during hypoglycemia
    • Trajanoski Z, Brunner GA, Gfrerer RJ, et al. Accuracy of home blood glucose meters during hypoglycemia. Diabetes Care 1996;19:1412-15.
    • (1996) Diabetes Care , vol.19 , pp. 1412-1415
    • Trajanoski, Z.1    Brunner, G.A.2    Gfrerer, R.J.3
  • 47
    • 0031688085 scopus 로고    scopus 로고
    • Improved glycemic control in intensively treated type 1 diabetic patients using blood glucose meters with storage capability and computer-assisted analyses
    • Strowig SM, Raskin P. Improved glycemic control in intensively treated type 1 diabetic patients using blood glucose meters with storage capability and computer-assisted analyses. Diabetes Care 1998;21:1694-8.
    • (1998) Diabetes Care , vol.21 , pp. 1694-1698
    • Strowig, S.M.1    Raskin, P.2
  • 48
    • 70350175257 scopus 로고    scopus 로고
    • Glucose meters: A review of technical challenges to obtaining accurate results
    • Tonyushkina K, Nichols JH. Glucose meters: a review of technical challenges to obtaining accurate results. J Diabetes Sci Technol 2009;3:971-80.
    • (2009) J Diabetes Sci Technol , vol.3 , pp. 971-980
    • Tonyushkina, K.1    Nichols, J.H.2
  • 49
    • 39049121806 scopus 로고    scopus 로고
    • A glucose meter accuracy and precision comparison: The FreeStyle Flash versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic
    • Thomas LE, Kane MP, Bakst G, et al. A glucose meter accuracy and precision comparison: the FreeStyle Flash versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic. Diabetes Technol Ther 2008;10:102-10.
    • (2008) Diabetes Technol Ther , vol.10 , pp. 102-110
    • Thomas, L.E.1    Kane, M.P.2    Bakst, G.3
  • 50
    • 0032882086 scopus 로고    scopus 로고
    • Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes
    • Garg SK, Potts RO, Ackerman NR, et al. Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes. Diabetes Care 1999;22:1708-14.
    • (1999) Diabetes Care , vol.22 , pp. 1708-1714
    • Garg, S.K.1    Potts, R.O.2    Ackerman, N.R.3
  • 51
    • 0020402631 scopus 로고
    • Wearable artificial endocrine pancrease with needle-type glucose sensor
    • Shichiri M, Kawamori R, Yamasaki Y, et al. Wearable artificial endocrine pancrease with needle-type glucose sensor. Lancet 1982;2:1129-31.
    • (1982) Lancet , vol.2 , pp. 1129-1131
    • Shichiri, M.1    Kawamori, R.2    Yamasaki, Y.3
  • 52
    • 0033759474 scopus 로고    scopus 로고
    • Can interstitial glucose assessment replace blood glucose measurements?
    • Rebrin K, Steil GM. Can interstitial glucose assessment replace blood glucose measurements? Diabetes Technol Ther 2000;2:461-72.
    • (2000) Diabetes Technol Ther , vol.2 , pp. 461-472
    • Rebrin, K.1    Steil, G.M.2
  • 53
    • 4344699878 scopus 로고    scopus 로고
    • The public health impact of the MiniMed Continuous Glucose Monitoring System (CGMS)-an assessment of the literature
    • Tavris DR, Shoaibi A. The public health impact of the MiniMed Continuous Glucose Monitoring System (CGMS)-an assessment of the literature. Diabetes Technol Ther 2004;6:518-22.
    • (2004) Diabetes Technol Ther , vol.6 , pp. 518-522
    • Tavris, D.R.1    Shoaibi, A.2
  • 54
    • 78049505569 scopus 로고    scopus 로고
    • Patient perceptions of different lancing sites for self-monitoring of blood glucose: A comparison of fingertip site with palm site using the OneTouch Ultra Blood Glucose Monitoring System
    • Ito T, Kamoi K, Minagawa S, et al. Patient perceptions of different lancing sites for self-monitoring of blood glucose: a comparison of fingertip site with palm site using the OneTouch Ultra Blood Glucose Monitoring System. J Diabetes Sci Technol 2010;4:906-10.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 906-910
    • Ito, T.1    Kamoi, K.2    Minagawa, S.3
  • 55
    • 23944480390 scopus 로고    scopus 로고
    • Alternative site self blood glucose testing is preferred by women with gestational diabetes
    • Clarke P, Coleman MA, Holt RI. Alternative site self blood glucose testing is preferred by women with gestational diabetes. Diabetes Technol Ther 2005;7:604-8.
    • (2005) Diabetes Technol Ther , vol.7 , pp. 604-608
    • Clarke, P.1    Coleman, M.A.2    Holt, R.I.3
  • 56
    • 4344718414 scopus 로고    scopus 로고
    • Clinical performance and ease of use of the Ascensia Breeze
    • Lekarcyk J, Ghiloni S. Clinical performance and ease of use of the Ascensia Breeze. Diabetes Technol Ther 2004;6:503-4.
    • (2004) Diabetes Technol Ther , vol.6 , pp. 503-504
    • Lekarcyk, J.1    Ghiloni, S.2
  • 57
    • 0242363717 scopus 로고    scopus 로고
    • A continuous glucose sensor based on wired enzyme technology - Results from a 3-day trial in patients with type 1 diabetes
    • Feldman B, Brazg R, Schwartz S, et al. A continuous glucose sensor based on wired enzyme technology - results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther 2003;5:769-79.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 769-779
    • Feldman, B.1    Brazg, R.2    Schwartz, S.3
  • 58
    • 17844400984 scopus 로고    scopus 로고
    • Evaluation of a new blood glucose monitoring system with auto-calibration
    • Kilo C, Pinson M, Joynes JO, et al. Evaluation of a new blood glucose monitoring system with auto-calibration. Diabetes Technol Ther 2005;7:283-94.
    • (2005) Diabetes Technol Ther , vol.7 , pp. 283-294
    • Kilo, C.1    Pinson, M.2    Joynes, J.O.3
  • 59
    • 84873191107 scopus 로고    scopus 로고
    • Integrated self-monitoring of blood glucose system: Handling step analysis
    • Freckmann G, Schmid C, Ruhland K, et al. Integrated self-monitoring of blood glucose system: handling step analysis. J Diabetes Sci Technol 2012;6:938-46.
    • (2012) J Diabetes Sci Technol , vol.6 , pp. 938-946
    • Freckmann, G.1    Schmid, C.2    Ruhland, K.3
  • 60
    • 84888106763 scopus 로고    scopus 로고
    • Two site evaluation of the performance of a new generation point-of-care glucose meter for use in a neonatal intensive care unit
    • Tendl KA, Christoph J, Bohn A, et al. Two site evaluation of the performance of a new generation point-of-care glucose meter for use in a neonatal intensive care unit. Clin Chem Lab Med 2013;51:1747-54.
    • (2013) Clin Chem Lab Med , vol.51 , pp. 1747-1754
    • Tendl, K.A.1    Christoph, J.2    Bohn, A.3
  • 61
    • 77953074552 scopus 로고    scopus 로고
    • Performance analysis of the OneTouch UltraVue blood glucose monitoring system
    • Chang A, Orth A, Le B, et al. Performance analysis of the OneTouch UltraVue blood glucose monitoring system. J Diabetes Sci Technol 2009;3:1158-65.
    • (2009) J Diabetes Sci Technol , vol.3 , pp. 1158-1165
    • Chang, A.1    Orth, A.2    Le, B.3
  • 62
    • 79955557642 scopus 로고    scopus 로고
    • Accuracy and precision evaluation of seven self-monitoring blood glucose systems
    • Kuo CY, Hsu CT, Ho CS, et al. Accuracy and precision evaluation of seven self-monitoring blood glucose systems. Diabetes Technol Ther 2011;13:596-600.
    • (2011) Diabetes Technol Ther , vol.13 , pp. 596-600
    • Kuo, C.Y.1    Hsu, C.T.2    Ho, C.S.3
  • 63
    • 0019531971 scopus 로고
    • Blood glucose control
    • Bernstein RK. Blood glucose control. Arch Intern Med 1981;141:267-8.
    • (1981) Arch Intern Med , vol.141 , pp. 267-268
    • Bernstein, R.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.