메뉴 건너뛰기




Volumn 55, Issue 3, 2015, Pages 522-531

In vitro evaluation of the quality of blood products collected and stored in systems completely free of di(2-ethylhexyl)phthalate-plasticized materials

Author keywords

[No Author keywords available]

Indexed keywords

2,3 DIPHOSPHOGLYCERIC ACID; ADENOSINE TRIPHOSPHATE; PHTHALIC ACID BIS(2 ETHYLHEXYL) ESTER; THROMBOCYTE CONCENTRATE; ADENINE; ADSOL; AS-3 PRESERVATIVE SOLUTION; CITRIC ACID; CYCLOHEXANECARBOXYLIC ACID DERIVATIVE; DICARBOXYLIC ACID; DIISONONYL 1,2-CYCLOHEXANEDICARBOXYLIC ACID; GLUCOSE; GUANOSINE; MANNITOL; PAGGS-M SOLUTION; PHOSPHATE; PLASTICIZER; SODIUM CHLORIDE; SOLUTION AND SOLUBILITY;

EID: 84924353751     PISSN: 00411132     EISSN: 15372995     Source Type: Journal    
DOI: 10.1111/trf.12870     Document Type: Article
Times cited : (45)

References (46)
  • 1
    • 0014959946 scopus 로고
    • Plasticizers from plastic devices extraction, metabolism, and accumulation by biological systems
    • Jaeger RJ, Rubin RJ,. Plasticizers from plastic devices extraction, metabolism, and accumulation by biological systems. Science 1970; 170 (3956): 460-462.
    • (1970) Science , vol.170 , Issue.3956 , pp. 460-462
    • Jaeger, R.J.1    Rubin, R.J.2
  • 2
    • 0015530106 scopus 로고
    • Migration of a phthalate ester plasticizer from polyvinyl chloride blood bags into stored human blood and its localization in human tissues
    • Jaeger RJ, Rubin RJ,. Migration of a phthalate ester plasticizer from polyvinyl chloride blood bags into stored human blood and its localization in human tissues. N Engl J Med 1972; 287: 1114-1118.
    • (1972) N Engl J Med , vol.287 , pp. 1114-1118
    • Jaeger, R.J.1    Rubin, R.J.2
  • 3
    • 79951599520 scopus 로고    scopus 로고
    • DEHP-plasticised PVC: Relevance to blood services
    • Sampson J, de Korte D,. DEHP-plasticised PVC: relevance to blood services. Transfus Med 2010; 21: 73-83.
    • (2010) Transfus Med , vol.21 , pp. 73-83
    • Sampson, J.1    De Korte, D.2
  • 4
    • 0017913163 scopus 로고
    • Di-2-ethylhexylphthalate (DEHP) content of blood or blood components stored in plastic bags
    • Sasakawa S, Mitomi Y,. Di-2-ethylhexylphthalate (DEHP) content of blood or blood components stored in plastic bags. Vox Sang 1978; 34: 81-86.
    • (1978) Vox Sang , vol.34 , pp. 81-86
    • Sasakawa, S.1    Mitomi, Y.2
  • 5
    • 0015798293 scopus 로고
    • Di-2-ethylhexyl phthalate, a plasticizer contaminant of platelet concentrates
    • Jaeger RJ, Rubin RJ,. Di-2-ethylhexyl phthalate, a plasticizer contaminant of platelet concentrates. Transfusion 1973; 13: 107-111.
    • (1973) Transfusion , vol.13 , pp. 107-111
    • Jaeger, R.J.1    Rubin, R.J.2
  • 6
    • 0016380696 scopus 로고
    • Accumulation of DI-2-ethylhexyl phthalate (DEHP) in WB, platelet concentrates, and platelet-poor plasma
    • Contreras TJ, Sheibley RH, Valeri CR,. Accumulation of DI-2-ethylhexyl phthalate (DEHP) in WB, platelet concentrates, and platelet-poor plasma. Transfusion 1974; 14: 34-46.
    • (1974) Transfusion , vol.14 , pp. 34-46
    • Contreras, T.J.1    Sheibley, R.H.2    Valeri, C.R.3
  • 7
    • 84892853051 scopus 로고    scopus 로고
    • Should DEHP be eliminated in blood bags?
    • van der Meer PF, Reesink HW, Panzer S, et-al. Should DEHP be eliminated in blood bags? Vox Sang 2014; 106: 176-195.
    • (2014) Vox Sang , vol.106 , pp. 176-195
    • Van Der Meer, P.F.1    Reesink, H.W.2    Panzer, S.3
  • 8
    • 82955195861 scopus 로고    scopus 로고
    • Progress in the removal of di-[2-ethylhexyl]-phthalate as plasticizer in blood bags
    • Simmchen J, Ventura R, Segura J,. Progress in the removal of di-[2-ethylhexyl]-phthalate as plasticizer in blood bags. Transfus Med Rev 2012; 26: 27-37.
    • (2012) Transfus Med Rev , vol.26 , pp. 27-37
    • Simmchen, J.1    Ventura, R.2    Segura, J.3
  • 9
    • 0021282227 scopus 로고
    • Five-day storage of platelet concentrates
    • Rock G, Sherring VA, Tittley P,. Five-day storage of platelet concentrates. Transfusion 1984; 24: 147-152.
    • (1984) Transfusion , vol.24 , pp. 147-152
    • Rock, G.1    Sherring, V.A.2    Tittley, P.3
  • 10
    • 0020569310 scopus 로고
    • Prevention of leakage of Di-(2-ethylhexyl)phthalate from blood bags by glow discharge treatment and its effect on aggregability of stored platelets
    • Ishikawa Y, Honda K, Sasakawa S, et-al. Prevention of leakage of Di-(2-ethylhexyl)phthalate from blood bags by glow discharge treatment and its effect on aggregability of stored platelets. Vox Sang 1983; 45: 68-76.
    • (1983) Vox Sang , vol.45 , pp. 68-76
    • Ishikawa, Y.1    Honda, K.2    Sasakawa, S.3
  • 11
    • 0022493532 scopus 로고
    • Platelet storage. Effects of leachable materials on morphology and function
    • Labow RS, Tocchi M, Rock G,. Platelet storage. Effects of leachable materials on morphology and function. Transfusion 1986; 26: 351-357.
    • (1986) Transfusion , vol.26 , pp. 351-357
    • Labow, R.S.1    Tocchi, M.2    Rock, G.3
  • 12
    • 0026002898 scopus 로고
    • Storage of platelets in a new plastic container. Polyvinyl chloride plasticized with butyryl-n-trihexyl citrate
    • Gulliksson H, Shanwell A, Wikman A, et-al. Storage of platelets in a new plastic container. Polyvinyl chloride plasticized with butyryl-n-trihexyl citrate. Vox Sang 1991; 61: 165-170.
    • (1991) Vox Sang , vol.61 , pp. 165-170
    • Gulliksson, H.1    Shanwell, A.2    Wikman, A.3
  • 13
    • 0021822387 scopus 로고
    • Extended storage of platelets in a new plastic container. I. Biochemical and morphologic changes
    • Grode G, Miripol J, Garber J, et-al. Extended storage of platelets in a new plastic container. I. Biochemical and morphologic changes. Transfusion 1985; 25: 204-208.
    • (1985) Transfusion , vol.25 , pp. 204-208
    • Grode, G.1    Miripol, J.2    Garber, J.3
  • 14
    • 0023502982 scopus 로고
    • Survival of red cells stored for 21 and 35 days in a non-di-(2-ethylhexyl)phthalate plastic container
    • Myhre BA, Johnson D, Marcus CS, et-al. Survival of red cells stored for 21 and 35 days in a non-di-(2-ethylhexyl)phthalate plastic container. Vox Sang 1987; 53: 199-202.
    • (1987) Vox Sang , vol.53 , pp. 199-202
    • Myhre, B.A.1    Johnson, D.2    Marcus, C.S.3
  • 15
    • 0036651660 scopus 로고    scopus 로고
    • Biochemical and structural changes in RBCs stored with different plasticizers: The role of hexanol
    • Draper CJ, Greenwalt TJ, Dumaswala UJ,. Biochemical and structural changes in RBCs stored with different plasticizers: the role of hexanol. Transfusion 2002; 42: 830-835.
    • (2002) Transfusion , vol.42 , pp. 830-835
    • Draper, C.J.1    Greenwalt, T.J.2    Dumaswala, U.J.3
  • 16
    • 0023243626 scopus 로고
    • The effect of the plasticizer di(2-ethylhexyl)phthalate on red cell deformability
    • Labow RS, Card RT, Rock G,. The effect of the plasticizer di(2-ethylhexyl)phthalate on red cell deformability. Blood 1987; 70: 319-323.
    • (1987) Blood , vol.70 , pp. 319-323
    • Labow, R.S.1    Card, R.T.2    Rock, G.3
  • 17
    • 0021684067 scopus 로고
    • Characterization of erythrocyte quality during the refrigerated storage of whole blood containing di-(2-ethylhexyl) phthalate
    • Estep TN, Pedersen RA, Miller TJ, et-al. Characterization of erythrocyte quality during the refrigerated storage of whole blood containing di-(2-ethylhexyl) phthalate. Blood 1984; 64: 1270-1276.
    • (1984) Blood , vol.64 , pp. 1270-1276
    • Estep, T.N.1    Pedersen, R.A.2    Miller, T.J.3
  • 18
    • 0021752532 scopus 로고
    • Incorporation of plasticizer into red cells during storage
    • Rock G, Tocchi M, Ganz PR, et-al. Incorporation of plasticizer into red cells during storage. Transfusion 1984; 24: 493-498.
    • (1984) Transfusion , vol.24 , pp. 493-498
    • Rock, G.1    Tocchi, M.2    Ganz, P.R.3
  • 19
    • 0021906486 scopus 로고
    • Stabilization of red blood cells by the plasticizer, diethylhexylphthalate
    • Horowitz B, Stryker MH, Waldman AA, et-al. Stabilization of red blood cells by the plasticizer, diethylhexylphthalate. Vox Sang 1985; 48: 150-155.
    • (1985) Vox Sang , vol.48 , pp. 150-155
    • Horowitz, B.1    Stryker, M.H.2    Waldman, A.A.3
  • 20
    • 0023853842 scopus 로고
    • The effect of the plasticizer di-2-ethylhexyl phthalate on the survival of stored RBCs
    • AuBuchon JP, Estep TN, Davey RJ,. The effect of the plasticizer di-2-ethylhexyl phthalate on the survival of stored RBCs. Blood 1988; 71: 448-452.
    • (1988) Blood , vol.71 , pp. 448-452
    • Aubuchon, J.P.1    Estep, T.N.2    Davey, R.J.3
  • 21
    • 33947663652 scopus 로고    scopus 로고
    • Substitution of di(2-ethylhexyl) phthalate by di(isononyl) cyclohexane-1,2-dicarboxylate as plasticizer for industrial vinyl plastisol formulations
    • Crespo JE, Balart R, Sanchez L, et-al. Substitution of di(2-ethylhexyl) phthalate by di(isononyl) cyclohexane-1,2-dicarboxylate as plasticizer for industrial vinyl plastisol formulations. J Appl Polym Sci 2007; 104: 1215-1220.
    • (2007) J Appl Polym Sci , vol.104 , pp. 1215-1220
    • Crespo, J.E.1    Balart, R.2    Sanchez, L.3
  • 22
    • 67650248285 scopus 로고    scopus 로고
    • Degradation of poly(vinyl chloride) plasticized with non-phthalate plasticizers under sterilization conditions
    • Burgos N, Jimenez A,. Degradation of poly(vinyl chloride) plasticized with non-phthalate plasticizers under sterilization conditions. Polym Degrad Staby 2009; 94: 1473-1478.
    • (2009) Polym Degrad Staby , vol.94 , pp. 1473-1478
    • Burgos, N.1    Jimenez, A.2
  • 23
    • 4544225274 scopus 로고    scopus 로고
    • An innovative plasticizer for sensitive applications
    • Wadey BL,. An innovative plasticizer for sensitive applications. J Vinyl Addit Technol 2003; 9: 172-176.
    • (2003) J Vinyl Addit Technol , vol.9 , pp. 172-176
    • Wadey, B.L.1
  • 24
    • 84863805903 scopus 로고    scopus 로고
    • Exploratory in vitro study of red blood cell storage containers formulated with an alternative plasticizer
    • Dumont LJ, Baker S, Dumont DF, et-al. Exploratory in vitro study of red blood cell storage containers formulated with an alternative plasticizer. Transfusion 2012; 52: 1439-1445.
    • (2012) Transfusion , vol.52 , pp. 1439-1445
    • Dumont, L.J.1    Baker, S.2    Dumont, D.F.3
  • 25
    • 84924412443 scopus 로고    scopus 로고
    • In vitro evaluation of the quality of red blood cells collected and stored in systems completely free of DEHP plasticized materials
    • Lagerberg JW, Vlaar R, Gouwerok CW, et-al. In vitro evaluation of the quality of red blood cells collected and stored in systems completely free of DEHP plasticized materials. Vox Sang 2012; 103 (Suppl 1): 120.
    • (2012) Vox Sang , vol.103 , pp. 120
    • Lagerberg, J.W.1    Vlaar, R.2    Gouwerok, C.W.3
  • 26
    • 0033668245 scopus 로고    scopus 로고
    • Polyvinylchloride infusion lines expose infants to large amounts of toxic plasticizers
    • Loff S, Kabs F, Witt K, et-al. Polyvinylchloride infusion lines expose infants to large amounts of toxic plasticizers. J Pediatr Surg 2000; 35: 1775-1781.
    • (2000) J Pediatr Surg , vol.35 , pp. 1775-1781
    • Loff, S.1    Kabs, F.2    Witt, K.3
  • 27
    • 53849125444 scopus 로고    scopus 로고
    • Erythrocyte storage in hypertonic (SAGM) or isotonic (PAGGSM) conservation medium: Influence on cell properties
    • Zehnder L, Schulzki T, Goede JS, et-al. Erythrocyte storage in hypertonic (SAGM) or isotonic (PAGGSM) conservation medium: influence on cell properties. Vox Sang 2008; 95: 280-287.
    • (2008) Vox Sang , vol.95 , pp. 280-287
    • Zehnder, L.1    Schulzki, T.2    Goede, J.S.3
  • 28
    • 78651389298 scopus 로고    scopus 로고
    • Effect of additive solutions on red blood cell (RBC) membrane properties of stored RBCs prepared from whole blood held for 24 hours at room temperature
    • Veale MF, Healey G, Sparrow RL,. Effect of additive solutions on red blood cell (RBC) membrane properties of stored RBCs prepared from whole blood held for 24 hours at room temperature. Transfusion 2011; 51: 25S-33S.
    • (2011) Transfusion , vol.51 , pp. 25S-33S
    • Veale, M.F.1    Healey, G.2    Sparrow, R.L.3
  • 29
    • 84882453414 scopus 로고    scopus 로고
    • Quality of red blood cells washed using the ACP 215 cell processor: Assessment of optimal pre- and postwash storage times and conditions
    • Hansen A, Yi QL, Acker JP,. Quality of red blood cells washed using the ACP 215 cell processor: assessment of optimal pre- and postwash storage times and conditions. Transfusion 2013; 53: 1772-1779.
    • (2013) Transfusion , vol.53 , pp. 1772-1779
    • Hansen, A.1    Yi, Q.L.2    Acker, J.P.3
  • 30
    • 36348965279 scopus 로고    scopus 로고
    • Altered processing of thawed red cells to improve the in vitro quality during postthaw storage at 4 degrees C
    • Lagerberg JW, Truijens-de Lange R, de Korte D, et-al. Altered processing of thawed red cells to improve the in vitro quality during postthaw storage at 4 degrees C. Transfusion 2007; 47: 2242-2249.
    • (2007) Transfusion , vol.47 , pp. 2242-2249
    • Lagerberg, J.W.1    Truijens-De Lange, R.2    De Korte, D.3
  • 31
    • 44849127632 scopus 로고    scopus 로고
    • Prolonged maintenance of 2,3-diphosphoglycerate acid and adenosine triphosphate in red blood cells during storage
    • de Korte D, Kleine M, Korsten HG, et-al. Prolonged maintenance of 2,3-diphosphoglycerate acid and adenosine triphosphate in red blood cells during storage. Transfusion 2008; 48: 1081-1089.
    • (2008) Transfusion , vol.48 , pp. 1081-1089
    • De Korte, D.1    Kleine, M.2    Korsten, H.G.3
  • 32
    • 0024498597 scopus 로고
    • Storage of whole blood for up to 24 hours at ambient temperature prior to component preparation
    • Pietersz RN, de Korte D, Reesink HW, et-al. Storage of whole blood for up to 24 hours at ambient temperature prior to component preparation. Vox Sang 1989; 56: 145-150.
    • (1989) Vox Sang , vol.56 , pp. 145-150
    • Pietersz, R.N.1    De Korte, D.2    Reesink, H.W.3
  • 33
    • 0033044701 scopus 로고    scopus 로고
    • Automated separation of whole blood in top and bottom bags into components using the Compomat G4
    • van der Meer P, Pietersz R, Hinloopen B, et-al. Automated separation of whole blood in top and bottom bags into components using the Compomat G4. Vox Sang 1999; 76: 90-99.
    • (1999) Vox Sang , vol.76 , pp. 90-99
    • Van Der Meer, P.1    Pietersz, R.2    Hinloopen, B.3
  • 34
    • 0141928003 scopus 로고    scopus 로고
    • Composition of the additive solution affects red blood cell integrity after photodynamic treatment
    • Besselink GA, Ebbing IG, Hilarius PM, et-al. Composition of the additive solution affects red blood cell integrity after photodynamic treatment. Vox Sang 2003; 85: 183-189.
    • (2003) Vox Sang , vol.85 , pp. 183-189
    • Besselink, G.A.1    Ebbing, I.G.2    Hilarius, P.M.3
  • 35
    • 0021248849 scopus 로고
    • Quantitative assessment of platelet morphology by light scattering: A potential method for the evaluation of platelets for transfusion
    • Fratantoni JC, Poindexter BJ, Bonner RF,. Quantitative assessment of platelet morphology by light scattering: a potential method for the evaluation of platelets for transfusion. J Lab Clin Med 1984; 103: 620-631.
    • (1984) J Lab Clin Med , vol.103 , pp. 620-631
    • Fratantoni, J.C.1    Poindexter, B.J.2    Bonner, R.F.3
  • 36
    • 0016630609 scopus 로고
    • A study of variables affecting the quality of platelets stored at "room temperature
    • Kunicki TJ, Tuccelli M, Becker GA, et-al. A study of variables affecting the quality of platelets stored at "room temperature." Transfusion 1975; 15: 414-421.
    • (1975) Transfusion , vol.15 , pp. 414-421
    • Kunicki, T.J.1    Tuccelli, M.2    Becker, G.A.3
  • 37
    • 52049116925 scopus 로고    scopus 로고
    • Flow cytometric measurement of CD62P (P-selectin) expression on platelets: A multicenter optimization and standardization effort
    • Curvers J, de Wildt-Eggen J, Heeremans J, et-al. Flow cytometric measurement of CD62P (P-selectin) expression on platelets: a multicenter optimization and standardization effort. Transfusion 2008; 48: 1439-1446.
    • (2008) Transfusion , vol.48 , pp. 1439-1446
    • Curvers, J.1    De Wildt-Eggen, J.2    Heeremans, J.3
  • 38
    • 0030020463 scopus 로고    scopus 로고
    • Detection of altered membrane phospholipid asymmetry in subpopulations of human red blood cells using fluorescently labeled annexin v
    • Kuypers FA, Lewis RA, Hua M, et-al. Detection of altered membrane phospholipid asymmetry in subpopulations of human red blood cells using fluorescently labeled annexin V. Blood 1996; 87: 1179-1187.
    • (1996) Blood , vol.87 , pp. 1179-1187
    • Kuypers, F.A.1    Lewis, R.A.2    Hua, M.3
  • 39
    • 0018165283 scopus 로고
    • The accumulation of mono-2-ethylhexylphthalate (MEHP) during storage of whole blood and plasma
    • Rock G, Secours VE, Franklin CA, et-al. The accumulation of mono-2-ethylhexylphthalate (MEHP) during storage of whole blood and plasma. Transfusion 1978; 18: 553-558.
    • (1978) Transfusion , vol.18 , pp. 553-558
    • Rock, G.1    Secours, V.E.2    Franklin, C.A.3
  • 40
    • 0018744526 scopus 로고
    • Di-2-ethylhexyl phthalate (DEHP) and mono-2-ethylhexyl phthalate (MEHP) accumulation in whole blood and red cell concentrates
    • Peck CC, Odom DG, Friedman HI, et-al. Di-2-ethylhexyl phthalate (DEHP) and mono-2-ethylhexyl phthalate (MEHP) accumulation in whole blood and red cell concentrates. Transfusion 1979; 19: 137-146.
    • (1979) Transfusion , vol.19 , pp. 137-146
    • Peck, C.C.1    Odom, D.G.2    Friedman, H.I.3
  • 41
    • 84880836929 scopus 로고    scopus 로고
    • In vitro investigation of the effect of plasticizers on the blood compatibility of medical grade plasticized poly (vinyl chloride)
    • Zhong R, Wang H, Wu X, et-al. In vitro investigation of the effect of plasticizers on the blood compatibility of medical grade plasticized poly (vinyl chloride). J Mater Sci Mater Med 2013; 24: 1985-1992.
    • (2013) J Mater Sci Mater Med , vol.24 , pp. 1985-1992
    • Zhong, R.1    Wang, H.2    Wu, X.3
  • 42
    • 0021131861 scopus 로고
    • Erythrocyte membrane vesiculation and changes in membrane composition during storage in citrate-phosphate-dextrose-adenine-1
    • Greenwalt TJ, Bryan DJ, Dumaswala UJ,. Erythrocyte membrane vesiculation and changes in membrane composition during storage in citrate-phosphate-dextrose-adenine-1. Vox Sang 1984; 47: 261-270.
    • (1984) Vox Sang , vol.47 , pp. 261-270
    • Greenwalt, T.J.1    Bryan, D.J.2    Dumaswala, U.J.3
  • 43
    • 84898823838 scopus 로고    scopus 로고
    • Red cell storage in E-Sol 5 and Adsol additive solutions: Paired comparison using mixed and non-mixed study designs
    • Radwanski K, Thill M, Min K,. Red cell storage in E-Sol 5 and Adsol additive solutions: paired comparison using mixed and non-mixed study designs. Vox Sang 2013; 106: 322-329.
    • (2013) Vox Sang , vol.106 , pp. 322-329
    • Radwanski, K.1    Thill, M.2    Min, K.3
  • 44
    • 67651169521 scopus 로고    scopus 로고
    • Opinion of the Scientific Panel on food additives, flavourings, processing aids and materials in contact with food (AFC) on a request related to the 12th list of substances for food contact materials
    • Opinion of the Scientific Panel on food additives, flavourings, processing aids and materials in contact with food (AFC) on a request related to the 12th list of substances for food contact materials. EFSA J 2006; 395-401: 1-21.
    • (2006) EFSA J , vol.395-401 , pp. 1-21
  • 45
    • 84924371975 scopus 로고    scopus 로고
    • NICNAS. File No: EX/170 (STD/1259) Public Report. 1,2-Cyclohexanedicarboxylic acid, 1,2-diisononyl ester ("Hexamoll DINCH"). [cited 2014 Aug 8]. Available from
    • NICNAS. File No: EX/170 (STD/1259) Public Report. 1,2-Cyclohexanedicarboxylic acid, 1,2-diisononyl ester ("Hexamoll DINCH"). 2012 [cited 2014 Aug 8]. Available from: http://www.nicnas.gov.au/data/assets/worddoc/0003/6699/EX170FR.docx
    • (2012)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.