메뉴 건너뛰기




Volumn 27, Issue 1, 2015, Pages 12-16

Efficacy of the transillumination method for appropriate tracheal tube placement in small children: A randomized controlled trial

Author keywords

Child; General anesthesia; Intubation; Transillumination

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CHILD; CLINICAL EFFECTIVENESS; COMPARATIVE EFFECTIVENESS; CONTROLLED STUDY; DIAGNOSTIC IMAGING; ELECTIVE SURGERY; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE STYLET; GENERAL ANESTHESIA; HUMAN; IMAGING AND DISPLAY; MAIN STEM METHOD; MAJOR CLINICAL STUDY; OPERATING ROOM; PEDIATRIC ANESTHESIA; PEDIATRIC SURGERY; PRESCHOOL CHILD; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; STERNOCLAVICULAR JOINT; THORAX; THORAX RADIOGRAPHY; TRACHEOSTOMY TUBE; UNIVERSITY HOSPITAL; INFANT; NEWBORN; PROCEDURES;

EID: 84923262173     PISSN: 09528180     EISSN: 18734529     Source Type: Journal    
DOI: 10.1016/j.jclinane.2014.09.003     Document Type: Article
Times cited : (2)

References (15)
  • 1
    • 33644670239 scopus 로고    scopus 로고
    • A comparison of three methods for estimating appropriate tracheal tube depth in children
    • E.R. Mariano, C. Ramamoorthy, L.F. Chu, M. Chen, and G.B. Hammer A comparison of three methods for estimating appropriate tracheal tube depth in children Pediatr Anesth 15 2005 846 851
    • (2005) Pediatr Anesth , vol.15 , pp. 846-851
    • Mariano, E.R.1    Ramamoorthy, C.2    Chu, L.F.3    Chen, M.4    Hammer, G.B.5
  • 2
    • 0021888385 scopus 로고
    • Early experience with illuminated endotracheal tubes in premature and term infants
    • R.M. Heller, and R.B. Cotton Early experience with illuminated endotracheal tubes in premature and term infants Pediatrics 75 1985 664 666
    • (1985) Pediatrics , vol.75 , pp. 664-666
    • Heller, R.M.1    Cotton, R.B.2
  • 3
    • 0026265403 scopus 로고
    • Correct placement of endotracheal tube by single strand fiberoptic light in prematures. Initial clinical experience (in German with English abstract)
    • V. Zanardo, M. Ronconi, and G. Bertocchi Correct placement of endotracheal tube by single strand fiberoptic light in prematures. Initial clinical experience (in German with English abstract) Padiatr Padol 26 1991 227 228
    • (1991) Padiatr Padol , vol.26 , pp. 227-228
    • Zanardo, V.1    Ronconi, M.2    Bertocchi, G.3
  • 5
    • 0016753481 scopus 로고
    • Diagnosis of pneumothorax or pneumomediastinum in the neonate by transillumination
    • L.R. Kuhns, F.J. Bednarek, M.L. Wyman, D.W. Roloff, and R.C. Borer Diagnosis of pneumothorax or pneumomediastinum in the neonate by transillumination Pediatrics 56 1975 355 360
    • (1975) Pediatrics , vol.56 , pp. 355-360
    • Kuhns, L.R.1    Bednarek, F.J.2    Wyman, M.L.3    Roloff, D.W.4    Borer, R.C.5
  • 7
    • 0032146391 scopus 로고    scopus 로고
    • Assessment of the proper depth of endotracheal tube placement with the Trachlight
    • G.L. Locker, T. Staudinger, and S. Knapp Assessment of the proper depth of endotracheal tube placement with the Trachlight J Clin Anesth 10 1998 389 393
    • (1998) J Clin Anesth , vol.10 , pp. 389-393
    • Locker, G.L.1    Staudinger, T.2    Knapp, S.3
  • 8
    • 0035103597 scopus 로고    scopus 로고
    • Finding appropriate endotracheal tube position by Trachlight in children (in Japanese with English abstract)
    • Y. Hayakawa, A. Iizawa, H. Iida, and S. Dohi Finding appropriate endotracheal tube position by Trachlight in children (in Japanese with English abstract) Masui 50 2001 175 178
    • (2001) Masui , vol.50 , pp. 175-178
    • Hayakawa, Y.1    Iizawa, A.2    Iida, H.3    Dohi, S.4
  • 9
    • 3042521169 scopus 로고    scopus 로고
    • Auscultation of Bilateral breath sounds does not rule out endobronchial intubation in children
    • S.D. Verghese, R.S. Hannallah, M.C. Slack, R.R. Cross, and K.M. Patel Auscultation of Bilateral breath sounds does not rule out endobronchial intubation in children Anesth Analg 99 2004 56 58
    • (2004) Anesth Analg , vol.99 , pp. 56-58
    • Verghese, S.D.1    Hannallah, R.S.2    Slack, M.C.3    Cross, R.R.4    Patel, K.M.5
  • 10
    • 0033032727 scopus 로고    scopus 로고
    • Does the Murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation?
    • K. Sugiyama, K. Yokoyama, and K. Satoh Does the Murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation? Anesth Analg 88 1999 1380 1383
    • (1999) Anesth Analg , vol.88 , pp. 1380-1383
    • Sugiyama, K.1    Yokoyama, K.2    Satoh, K.3
  • 11
    • 0141677974 scopus 로고    scopus 로고
    • The intubation depth marker: The confusion of the black line
    • S. Goel, and S.L. LIM The intubation depth marker: the confusion of the black line Paediatr Anaesth 13 2003 579 583
    • (2003) Paediatr Anaesth , vol.13 , pp. 579-583
    • Goel, S.1    Lim, S.L.2
  • 12
  • 13
    • 0029314396 scopus 로고
    • Alterations in endobronchial tube position with head and neck movement
    • K.O. Sun Alterations in endobronchial tube position with head and neck movement Anaesth Intensive Care 23 1995 403 404
    • (1995) Anaesth Intensive Care , vol.23 , pp. 403-404
    • Sun, K.O.1
  • 14
    • 0022136925 scopus 로고
    • Movement of the distal end of the endotracheal tube during flexion and extension of the neck
    • T.J. Roung, R. Grayson, and J. Saklad Movement of the distal end of the endotracheal tube during flexion and extension of the neck Anesth Analg 64 1985 1030 1032
    • (1985) Anesth Analg , vol.64 , pp. 1030-1032
    • Roung, T.J.1    Grayson, R.2    Saklad, J.3
  • 15
    • 0018873730 scopus 로고
    • Mechanism of endotracheal tube movement with change of head position in the neonate
    • S.M. Donn, and L.R. Kuhns Mechanism of endotracheal tube movement with change of head position in the neonate Pediatr Radiol 9 1980 37 40
    • (1980) Pediatr Radiol , vol.9 , pp. 37-40
    • Donn, S.M.1    Kuhns, L.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.