메뉴 건너뛰기




Volumn 16, Issue 12, 2006, Pages 1238-1243

New formulae for predicting tracheal tube length

Author keywords

Intubation; Pediatric critical care; Pediatrics; Tracheal; Tracheal tubes

Indexed keywords

ACCURACY; ADOLESCENT; AGE DISTRIBUTION; ARTICLE; CHILD; DATA ANALYSIS; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; HUMAN; INFANT; INFORMATION PROCESSING; INTENSIVE CARE UNIT; LINEAR REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MATHEMATICAL ANALYSIS; MEDICAL DOCUMENTATION; NASOTRACHEAL INTUBATION; NEWBORN; PATIENT SELECTION; PEDIATRIC ADVANCED LIFE SUPPORT; PRACTICE GUIDELINE; PRIORITY JOURNAL; SAMPLE SIZE;

EID: 33751028700     PISSN: 11555645     EISSN: 14609592     Source Type: Journal    
DOI: 10.1111/j.1460-9592.2006.01982.x     Document Type: Article
Times cited : (52)

References (16)
  • 2
    • 0004225579 scopus 로고    scopus 로고
    • Collective Pty Ltd, 2003 (ISBN 0-9587434-2-8)
    • Shann F. Drug Doses, 12th edn. Collective Pty Ltd, 2003 (ISBN 0-9587434-2-8).
    • Drug Doses, 12th Edn.
    • Shann, F.1
  • 3
    • 24944538906 scopus 로고    scopus 로고
    • Accurate endotracheal tube placement in children: Depth of insertion is part of a process
    • Luten R. Accurate endotracheal tube placement in children: depth of insertion is part of a process. Pediatr Crit Care Med 2005; 6: 606-608.
    • (2005) Pediatr Crit Care Med , vol.6 , pp. 606-608
    • Luten, R.1
  • 4
    • 0033788576 scopus 로고    scopus 로고
    • Appropriateness of endotracheal tube size and insertion depth in children undergoing air medical transport
    • Orf J, Thomas SH, Ahmed W et al. Appropriateness of endotracheal tube size and insertion depth in children undergoing air medical transport. Pediatr Emerg Care 2000; 16: 321-327.
    • (2000) Pediatr Emerg Care , vol.16 , pp. 321-327
    • Orf, J.1    Thomas, S.H.2    Ahmed, W.3
  • 5
    • 0036656019 scopus 로고    scopus 로고
    • Endotracheal tube position in pediatrics and neonates: Comparison between flexible fiberoptic bronchoscopy and chest radiograph
    • Lee YS, Soong WJ, Jeng MJ et al. Endotracheal tube position in pediatrics and neonates: comparison between flexible fiberoptic bronchoscopy and chest radiograph. Zhonghua Yi Xue Za Zhi (Taipei) 2002; 65: 341-344.
    • (2002) Zhonghua Yi Xue Za Zhi (Taipei) , vol.65 , pp. 341-344
    • Lee, Y.S.1    Soong, W.J.2    Jeng, M.J.3
  • 6
    • 0141677974 scopus 로고    scopus 로고
    • The intubation depth marker: The confusion of the black line
    • Goel S, Lim SL. The intubation depth marker: the confusion of the black line. Paediatr Anaesth 2003; 13: 579-583.
    • (2003) Paediatr Anaesth , vol.13 , pp. 579-583
    • Goel, S.1    Lim, S.L.2
  • 7
    • 0036088825 scopus 로고    scopus 로고
    • Estimation of the length of nasotracheal tube to be introduced in children
    • de la Sierra AM, López-Herce J, Rupérez M et al. Estimation of the length of nasotracheal tube to be introduced in children. J Pediatr 2002; 140: 772-774.
    • (2002) J Pediatr , vol.140 , pp. 772-774
    • De La Sierra, A.M.1    López-Herce, J.2    Rupérez, M.3
  • 8
    • 24944591430 scopus 로고    scopus 로고
    • Prospective assessment of guidelines for determining appropriate depth of endotracheal tube placement in children
    • Phipps LM, Thomas NJ, Gilmore RK et al. Prospective assessment of guidelines for determining appropriate depth of endotracheal tube placement in children. Pediatr Crit Care Med 2005; 6: 519-522.
    • (2005) Pediatr Crit Care Med , vol.6 , pp. 519-522
    • Phipps, L.M.1    Thomas, N.J.2    Gilmore, R.K.3
  • 9
    • 0023318177 scopus 로고
    • Estimation of nasotracheal tube length in infants and children
    • Yates AP, Harries AJ, Hatch DJ. Estimation of nasotracheal tube length in infants and children. Br J Anaesth 1987; 59: 524-526.
    • (1987) Br J Anaesth , vol.59 , pp. 524-526
    • Yates, A.P.1    Harries, A.J.2    Hatch, D.J.3
  • 10
    • 0023880609 scopus 로고
    • A rapid method for estimating weight and resuscitation drug dosages from length in the pediatric age group
    • Lubitz DS, Seidel JS, Chameides L et al. A rapid method for estimating weight and resuscitation drug dosages from length in the pediatric age group. Ann Emerg Med 1988; 17: 576-581.
    • (1988) Ann Emerg Med , vol.17 , pp. 576-581
    • Lubitz, D.S.1    Seidel, J.S.2    Chameides, L.3
  • 11
    • 0141748274 scopus 로고    scopus 로고
    • Does the use of a specialised paediatric retrieval service result in the loss of vital stabilisation skills among referring hospital staff?
    • Ramnarayan P, Britto J, Tanna A et al. Does the use of a specialised paediatric retrieval service result in the loss of vital stabilisation skills among referring hospital staff? Arch Dis Child 2003; 88: 851-854.
    • (2003) Arch Dis Child , vol.88 , pp. 851-854
    • Ramnarayan, P.1    Britto, J.2    Tanna, A.3
  • 12
    • 0023918233 scopus 로고
    • Tracheal intubation in children: A new method for assuring correct depth of tube placement
    • Bloch EC, Ossey K, Ginsberg B. Tracheal intubation in children: a new method for assuring correct depth of tube placement. Anesth Analg 1988; 67: 590-592.
    • (1988) Anesth Analg , vol.67 , pp. 590-592
    • Bloch, E.C.1    Ossey, K.2    Ginsberg, B.3
  • 13
    • 0042326285 scopus 로고    scopus 로고
    • Comparative evaluation of methods for ensuring the correct position of the tracheal tube in children undergoing open heart surgery
    • Kim KO, Um WS, Kim CS. Comparative evaluation of methods for ensuring the correct position of the tracheal tube in children undergoing open heart surgery. Anaesthesia 2003; 58: 889-893.
    • (2003) Anaesthesia , vol.58 , pp. 889-893
    • Kim, K.O.1    Um, W.S.2    Kim, C.S.3
  • 14
    • 3042521169 scopus 로고    scopus 로고
    • Auscultation of bilateral breath sounds does not rule out endobronchial intubation in children
    • Verghese ST, Hannallah RS, Slack MC et al. Auscultation of bilateral breath sounds does not rule out endobronchial intubation in children. Anesth Analg 2004; 99: 56-58.
    • (2004) Anesth Analg , vol.99 , pp. 56-58
    • Verghese, S.T.1    Hannallah, R.S.2    Slack, M.C.3
  • 15
    • 0033032727 scopus 로고    scopus 로고
    • Does the Murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation?
    • Sugiyama K, Yokoyama K, Satoh K et al. Does the Murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation? Anesth Analg 1999; 88: 1380-1383.
    • (1999) Anesth Analg , vol.88 , pp. 1380-1383
    • Sugiyama, K.1    Yokoyama, K.2    Satoh, K.3
  • 16
    • 33644670239 scopus 로고    scopus 로고
    • A comparison of three methods for estimating appropriate tracheal tube depth in children
    • Mariano ER, Ramamoorthy C, Chu LF et al. A comparison of three methods for estimating appropriate tracheal tube depth in children. Pediatr Anesth 2005; 15: 846-851.
    • (2005) Pediatr Anesth , vol.15 , pp. 846-851
    • Mariano, E.R.1    Ramamoorthy, C.2    Chu, L.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.