메뉴 건너뛰기




Volumn 62, Issue 3, 2015, Pages 1803-1813

Screening of false induction motor fault alarms produced by axial air ducts based on the space-harmonic-induced current components

Author keywords

Condition monitoring; fault diagnosis; frequency domain analysis; induction motor; predictive maintenance

Indexed keywords

ALARM SYSTEMS; CONDITION MONITORING; DUCTS; ERRORS; FAILURE ANALYSIS; FAULT DETECTION; FREQUENCY DOMAIN ANALYSIS; HARMONIC ANALYSIS; INDUCTION MOTORS; TESTING;

EID: 84923076519     PISSN: 02780046     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIE.2014.2331027     Document Type: Article
Times cited : (29)

References (22)
  • 1
    • 84877742785 scopus 로고    scopus 로고
    • Validation of a faulted rotor induction machine model with an insightful geometrical interpretation of physical quantities
    • Sep
    • C. Concari, G. Franceschini, C. Tassoni, and A. Toscani, "Validation of a faulted rotor induction machine model with an insightful geometrical interpretation of physical quantities," IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 4074-4083, Sep. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.9 , pp. 4074-4083
    • Concari, C.1    Franceschini, G.2    Tassoni, C.3    Toscani, A.4
  • 2
    • 84877769102 scopus 로고    scopus 로고
    • High-resolution parameter estimation method to identify broken rotor bar faults in induction motors
    • Sep
    • Y. Kim, Y. Youn, D. Hwang, J. Sun, and D. Kang, "High-resolution parameter estimation method to identify broken rotor bar faults in induction motors," IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 4103-4117, Sep. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.9 , pp. 4103-4117
    • Kim, Y.1    Youn, Y.2    Hwang, D.3    Sun, J.4    Kang, D.5
  • 3
    • 84877754137 scopus 로고    scopus 로고
    • Detection and diagnosis of faults in induction motor using an improved artificial ant clustering technique
    • Sep
    • A. Soualhi, G. Clerc, and H. Razik, "Detection and diagnosis of faults in induction motor using an improved artificial ant clustering technique," IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 4053-4062, Sep. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.9 , pp. 4053-4062
    • Soualhi, A.1    Clerc, G.2    Razik, H.3
  • 4
    • 0024121951 scopus 로고
    • Noninvasive detection of broken rotor bars in operating induction motors
    • Dec
    • G. B. Kliman, R. A. Koegl, J. Stein, R. D. Endicott, and M. W. Madden, "Noninvasive detection of broken rotor bars in operating induction motors," IEEE Trans. Energy Convers., vol. 3, no. 4, pp. 873-879, Dec. 1988.
    • (1988) IEEE Trans. Energy Convers. , vol.3 , Issue.4 , pp. 873-879
    • Kliman, G.B.1    Koegl, R.A.2    Stein, J.3    Endicott, R.D.4    Madden, M.W.5
  • 5
    • 84891101514 scopus 로고    scopus 로고
    • Recent (2005-2006) case histories on the application of motor current signature analysis to detect broken rotor bars
    • Toronto, ON, Canada
    • W. Thomson, "Recent (2005-2006) case histories on the application of motor current signature analysis to detect broken rotor bars," in Proc. IRMC, Toronto, ON, Canada, 2006.
    • (2006) Proc. IRMC
    • Thomson, W.1
  • 6
    • 34147114973 scopus 로고    scopus 로고
    • Using current signature analysis technology to reliably detect cage winding defects in squirrel-cage induction motors
    • Mar./Apr
    • I. M. Culbert and W. Rhodes, "Using current signature analysis technology to reliably detect cage winding defects in squirrel-cage induction motors," IEEE Trans. Ind. Appl., vol. 43, no. 2, pp. 422-428, Mar./Apr. 2007.
    • (2007) IEEE Trans. Ind. Appl. , vol.43 , Issue.2 , pp. 422-428
    • Culbert, I.M.1    Rhodes, W.2
  • 7
    • 0002726897 scopus 로고
    • On-line current monitoring-The influence of mechanical loads or a unique rotor design on the diagnosis of broken rotor bars in induction motors
    • W. T. Thomson, "On-line current monitoring-The influence of mechanical loads or a unique rotor design on the diagnosis of broken rotor bars in induction motors," in Proc. ICEM, 1992, pp. 1236-1240.
    • (1992) Proc. ICEM , pp. 1236-1240
    • Thomson, W.T.1
  • 8
    • 0036631352 scopus 로고    scopus 로고
    • On-field experience with on-line diagnosis of large induction motors cage failures using MCSA
    • Jul./Aug
    • A. Bellini et al., "On-field experience with on-line diagnosis of large induction motors cage failures using MCSA," IEEE Trans. Ind. Appl., vol. 38, no. 4, pp. 1045-1053, Jul./Aug. 2002.
    • (2002) IEEE Trans. Ind. Appl. , vol.38 , Issue.4 , pp. 1045-1053
    • Bellini, A.1
  • 9
    • 84884651982 scopus 로고    scopus 로고
    • Evaluation of the influence of rotor axial air duct design on condition monitoring of induction motors
    • Oct
    • S. Lee et al., "Evaluation of the influence of rotor axial air duct design on condition monitoring of induction motors," IEEE Trans. Ind. Appl., vol. 49, no. 5, pp. 2024-2033, Oct. 2013.
    • (2013) IEEE Trans. Ind. Appl. , vol.49 , Issue.5 , pp. 2024-2033
    • Lee, S.1
  • 10
    • 84891115288 scopus 로고    scopus 로고
    • Reliable detection of induction motor rotor faults under the rotor axial air duct influence
    • Raleigh, NC, USA, Sep.
    • C. Yang et al., "Reliable detection of induction motor rotor faults under the rotor axial air duct influence," in Proc. IEEE ECCE, Raleigh, NC, USA, Sep. 2013, pp. 2508-2515.
    • (2013) Proc. IEEE ECCE , pp. 2508-2515
    • Yang, C.1
  • 11
    • 84870879860 scopus 로고    scopus 로고
    • Induction motor case histories: A focus on electrically related phenomena
    • Harrisburg, PA, USA
    • B. D. Evans, "Induction motor case histories: A focus on electrically related phenomena," in Proc. Vib. Inst. Annu. Meet., Harrisburg, PA, USA, 2009.
    • (2009) Proc. Vib. Inst. Annu. Meet.
    • Evans, B.D.1
  • 12
    • 84923089861 scopus 로고    scopus 로고
    • Testing of Squirrel Cage Rotors, EASA AR100-2010, Oct.
    • Testing of Squirrel Cage Rotors, EASA AR100-2010, Oct. 2010.
    • (2010)
  • 13
    • 0004134267 scopus 로고    scopus 로고
    • Madison, WI, USA: Wisconsin Power Electron. Res. Center, Uiv, Wisconsin
    • T. A. Lipo, Introduction to AC Machine Design. Madison, WI, USA: Wisconsin Power Electron. Res. Center, Uiv, Wisconsin, 2004.
    • (2004) Introduction to AC Machine Design
    • Lipo, T.A.1
  • 14
    • 84861518172 scopus 로고    scopus 로고
    • Diagnostics of rotor-cage faults supported by effects due to higher MMF harmonics
    • Jun
    • T. J. Sobczyk and W. Maciolek, "Diagnostics of rotor-cage faults supported by effects due to higher MMF harmonics," in Proc. IEEE Power Tech Conf., Jun. 2003, vol. 2, pp. 1-5.
    • (2003) Proc. IEEE Power Tech Conf. , vol.2 , pp. 1-5
    • Sobczyk, T.J.1    Maciolek, W.2
  • 16
    • 20544439623 scopus 로고    scopus 로고
    • Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults
    • May/Jun
    • H. Henao, H. Razik, and G. A. Capolino, "Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults," IEEE Trans. Ind. Appl., vol. 41, no. 3, pp. 801-807, May/Jun. 2005.
    • (2005) IEEE Trans. Ind. Appl. , vol.41 , Issue.3 , pp. 801-807
    • Henao, H.1    Razik, H.2    Capolino, G.A.3
  • 17
    • 40449096322 scopus 로고    scopus 로고
    • Low order PWM inverter harmonics contributions to the inverter-fed induction machine fault diagnosis
    • Feb
    • B. Akin, U. Orguner, H. A. Toliyat, and M. Rayner, "Low order PWM inverter harmonics contributions to the inverter-fed induction machine fault diagnosis," IEEE Trans. Ind. Electron., vol. 55, no. 2, pp. 610-619, Feb. 2008.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , Issue.2 , pp. 610-619
    • Akin, B.1    Orguner, U.2    Toliyat, H.A.3    Rayner, M.4
  • 19
    • 57749200463 scopus 로고    scopus 로고
    • Analysis and application of particular current signatures (symptoms) for cage monitoring in nonsinusoidally fed motors with high rejection to drive load, inertia, frequency variations
    • Dec
    • C. Bruzzese, "Analysis and application of particular current signatures (symptoms) for cage monitoring in nonsinusoidally fed motors with high rejection to drive load, inertia, frequency variations," IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4137-4155, Dec. 2008.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , Issue.12 , pp. 4137-4155
    • Bruzzese, C.1
  • 20
    • 84877740747 scopus 로고    scopus 로고
    • Stator-current spectrum signature of healthy cage rotor induction machines
    • Sep
    • G. M. Joksimovic, J. Riger, T. M. Wolbank, N. Peric, and M. Vasak, "Stator-current spectrum signature of healthy cage rotor induction machines," IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 4025-4033, Sep. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.9 , pp. 4025-4033
    • Joksimovic, G.M.1    Riger, J.2    Wolbank, T.M.3    Peric, N.4    Vasak, M.5
  • 21
    • 81255147074 scopus 로고    scopus 로고
    • Some digital signal processing techniques for induction machines diagnosis
    • Sep
    • S. H. Kia, H. Henao, and G.-A. Capolino, "Some digital signal processing techniques for induction machines diagnosis," in Proc. IEEE SDEMPED, Sep. 2011, pp. 322-329.
    • (2011) Proc. IEEE Sdemped , pp. 322-329
    • Kia, S.H.1    Henao, H.2    Capolino, G.-A.3
  • 22
    • 84887078282 scopus 로고    scopus 로고
    • Effects of the simultaneous presence of static eccentricity and broken rotor bars on the stator current of induction machine
    • May
    • M. Y. Kaikaa and M. Hadjami, "Effects of the simultaneous presence of static eccentricity and broken rotor bars on the stator current of induction machine," IEEE Trans. Ind. Electron., vol. 61, no. 5, pp. 2452-2463, May 2014.
    • (2014) IEEE Trans. Ind. Electron. , vol.61 , Issue.5 , pp. 2452-2463
    • Kaikaa, M.Y.1    Hadjami, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.