메뉴 건너뛰기




Volumn 7, Issue 9, 2014, Pages 882-892

Compressed sensing single-breath-hold CMR for fast quantification of LV function, volumes, and mass

Author keywords

cardiac function; fast imaging; fast LV assessment

Indexed keywords

ADULT; ARTICLE; BREATH HOLDING; CARDIOVASCULAR MAGNETIC RESONANCE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE ENDSYSTOLIC VOLUME; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE MASS; HEART LEFT VENTRICLE VOLUME; HEART STROKE VOLUME; HUMAN; IMAGE QUALITY; MALE; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; AGED; CASE CONTROL STUDY; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; DIAGNOSIS; FEASIBILITY STUDY; HEART VENTRICLE; MIDDLE AGED; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; PATHOPHYSIOLOGY; PREDICTIVE VALUE; REPRODUCIBILITY;

EID: 84922651061     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2014.04.016     Document Type: Article
Times cited : (120)

References (32)
  • 1
    • 0041730579 scopus 로고    scopus 로고
    • The association of left ventricular ejection fraction, mortality, and cause of death in stable outpatients with heart failure
    • Curtis JP, Sokol SI, Wang Y, et al. The association of left ventricular ejection fraction, mortality, and cause of death in stable outpatients with heart failure. J Am Coll Cardiol 2003;42:736-42.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 736-742
    • Curtis, J.P.1    Sokol, S.I.2    Wang, Y.3
  • 2
    • 0036623690 scopus 로고    scopus 로고
    • Chemotherapy-induced cardiotoxicity: Current practice and prospects of prophylaxis
    • Gharib MI, Burnett AK. Chemotherapy-induced cardiotoxicity: current practice and prospects of prophylaxis. Eur J Heart Fail 2002;4:235-42.
    • (2002) Eur J Heart Fail , vol.4 , pp. 235-242
    • Gharib, M.I.1    Burnett, A.K.2
  • 3
    • 19944429413 scopus 로고    scopus 로고
    • Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    • Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med 2005;352: 225-37.
    • (2005) N Engl J Med , vol.352 , pp. 225-237
    • Bardy, G.H.1    Lee, K.L.2    Mark, D.B.3
  • 4
    • 84877897377 scopus 로고    scopus 로고
    • Intracoronary injection of bone marrow-derived mononuclear cells early or late after acute myocardial infarction: Effects on global left ventricular function
    • Sürder D, Manka R, Lo Cicero V, et al. Intracoronary injection of bone marrow-derived mononuclear cells early or late after acute myocardial infarction: effects on global left ventricular function. Circulation 2013;127:1968-79.
    • (2013) Circulation , vol.127 , pp. 1968-1979
    • Sürder, D.1    Manka, R.2    Lo Cicero, V.3
  • 5
    • 63849177462 scopus 로고    scopus 로고
    • 2009 focused update incorporated into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults
    • Hunt SA, Abraham WT, Chin MH, et al. 2009 focused update incorporated into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults. J Am Coll Cardiol 2009;53:e1-90.
    • (2009) J Am Coll Cardiol , vol.53 , pp. e1-e90
    • Hunt, S.A.1    Abraham, W.T.2    Chin, M.H.3
  • 6
    • 84864493727 scopus 로고    scopus 로고
    • ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2012
    • McMurray JJV, Adamopoulos S, Anker SD, et al. ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2012. Eur Heart J 2012;33:1787-847.
    • (2012) Eur Heart J , vol.33 , pp. 1787-1847
    • McMurray, J.J.V.1    Adamopoulos, S.2    Anker, S.D.3
  • 7
    • 84885017843 scopus 로고    scopus 로고
    • Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update
    • Kramer C, Barkhausen J, Flamm S, et al. Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update. J Cardiovasc Magn Reson 2013;15:91.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 91
    • Kramer, C.1    Barkhausen, J.2    Flamm, S.3
  • 8
    • 77950479709 scopus 로고    scopus 로고
    • Recommendations for cardiovascular magnetic resonance in adults with congenital heart disease from the respective working groups of the European Society of Cardiology
    • Kilner PJ, Geva T, Kaemmerer H, et al. Recommendations for cardiovascular magnetic resonance in adults with congenital heart disease from the respective working groups of the European Society of Cardiology. Eur Heart J 2010;31:794-805.
    • (2010) Eur Heart J , vol.31 , pp. 794-805
    • Kilner, P.J.1    Geva, T.2    Kaemmerer, H.3
  • 9
    • 84879091688 scopus 로고    scopus 로고
    • Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR Registry: Description and validation of standardized criteria
    • Klinke V, Muzzarelli S, Lauriers N, et al. Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR Registry: description and validation of standardized criteria. J Cardiovasc Magn Reson 2013;15:55.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 55
    • Klinke, V.1    Muzzarelli, S.2    Lauriers, N.3
  • 10
    • 84872299548 scopus 로고    scopus 로고
    • European Cardiovascular Magnetic Resonance (EuroCMR) Registry-multi national results from 57 centers in 15 countries
    • Bruder O, Wagner A, Lombardi M, et al. European Cardiovascular Magnetic Resonance (EuroCMR) Registry-multi national results from 57 centers in 15 countries. J Cardiovasc Magn Reson 2013;15:1-9.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 1-9
    • Bruder, O.1    Wagner, A.2    Lombardi, M.3
  • 11
    • 47249163805 scopus 로고    scopus 로고
    • Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods
    • Kozerke S, Plein S. Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods. J Cardiovasc Magn Reson 2008;10:29.
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 29
    • Kozerke, S.1    Plein, S.2
  • 12
    • 34047142157 scopus 로고    scopus 로고
    • Fourdimensional single breathhold magnetic resonance imaging using kt-BLAST enables reliable assessment of left- and right-ventricular volumes and mass
    • Jahnke C, Nagel E, Gebker R, et al. Fourdimensional single breathhold magnetic resonance imaging using kt-BLAST enables reliable assessment of left- and right-ventricular volumes and mass. J Magn Reson Imaging 2007;25:737-42.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 737-742
    • Jahnke, C.1    Nagel, E.2    Gebker, R.3
  • 13
    • 76949090846 scopus 로고    scopus 로고
    • Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function
    • Eberle H, Nassenstein K, Jensen C, et al. Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function. Eur Radiol 2010;20:73-80.
    • (2010) Eur Radiol , vol.20 , pp. 73-80
    • Eberle, H.1    Nassenstein, K.2    Jensen, C.3
  • 14
    • 56149093323 scopus 로고    scopus 로고
    • K-t SENSE-accelerated myocardial perfusion MR imaging at 3.0 Tesla-comparison with 1.5 Tesla
    • Plein S, Schwitter J, Suerder D, et al. k-t SENSE-accelerated myocardial perfusion MR imaging at 3.0 Tesla-comparison with 1.5 Tesla. Radiology 2008;249:493-500.
    • (2008) Radiology , vol.249 , pp. 493-500
    • Plein, S.1    Schwitter, J.2    Suerder, D.3
  • 15
    • 33746875583 scopus 로고    scopus 로고
    • 2Dspatially- selective real-time magnetic resonance imaging for the assessment of microvascular function and its relation to the cardiovascular risk profile
    • Schwitter J, Oelhafen M, Wyss BM, et al. 2Dspatially- selective real-time magnetic resonance imaging for the assessment of microvascular function and its relation to the cardiovascular risk profile. J Cardiovasc Magn Reson 2006;8:759-69.
    • (2006) J Cardiovasc Magn Reson , vol.8 , pp. 759-769
    • Schwitter, J.1    Oelhafen, M.2    Wyss, B.M.3
  • 16
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007;58:1182-95.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 17
    • 84955173714 scopus 로고    scopus 로고
    • Dynamic cardiac MRI reconstruction with weighted redundant Haar wavelets (abstr)
    • Liu J. Dynamic cardiac MRI reconstruction with weighted redundant Haar wavelets (abstr). Proc Int Soc Magn Reson Med 2012;67:4249.
    • (2012) Proc Int Soc Magn Reson Med , vol.67 , pp. 4249
    • Liu, J.1
  • 18
    • 0033880824 scopus 로고    scopus 로고
    • Left ventricular mass and volume: Fast calculation with guide-point modeling on MR images
    • Young AA, Cowan BR, Thrupp SF, Hedley WJ, Dell'Italia LJ. Left ventricular mass and volume: fast calculation with guide-point modeling on MR images. Radiology 2000;216:597-602.
    • (2000) Radiology , vol.216 , pp. 597-602
    • Young, A.A.1    Cowan, B.R.2    Thrupp, S.F.3    Hedley, W.J.4    Dell'italia, L.J.5
  • 19
    • 0034643899 scopus 로고    scopus 로고
    • Magnetic resonance-based assessment of global coronary flow and flow reserve and its relation to left ventricular functional parameters: A comparison with positron emission tomography
    • Schwitter J, DeMarco T, Kneifel S, et al. Magnetic resonance-based assessment of global coronary flow and flow reserve and its relation to left ventricular functional parameters: a comparison with positron emission tomography. Circulation 2000;101:2696-702.
    • (2000) Circulation , vol.101 , pp. 2696-2702
    • Schwitter, J.1    Demarco, T.2    Kneifel, S.3
  • 20
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.1    Altman, D.2
  • 21
    • 84884890660 scopus 로고    scopus 로고
    • Impact of the Advisa MRI pacing system on the diagnostic quality of cardiac MR images and contraction patterns of cardiac muscle during scans: Advisa MRI randomized clinical multicenter study results
    • Schwitter J, Kanal E, Schmitt M, et al. Impact of the Advisa MRI pacing system on the diagnostic quality of cardiac MR images and contraction patterns of cardiac muscle during scans: Advisa MRI randomized clinical multicenter study results. Heart Rhythm 2013;10:864-72.
    • (2013) Heart Rhythm , vol.10 , pp. 864-872
    • Schwitter, J.1    Kanal, E.2    Schmitt, M.3
  • 22
    • 17644387147 scopus 로고    scopus 로고
    • Operator induced variability in cardiovascular MR: Left ventricular measurements and their reproducibility
    • Danilouchkine M, Westenberg J, De Roos A, Reiber J, Lelieveldt P. Operator induced variability in cardiovascular MR: left ventricular measurements and their reproducibility. J Cardiovasc Magn Reson 2005;7:447-57.
    • (2005) J Cardiovasc Magn Reson , vol.7 , pp. 447-457
    • Danilouchkine, M.1    Westenberg, J.2    De Roos, A.3    Reiber, J.4    Lelieveldt, P.5
  • 23
    • 0036642629 scopus 로고    scopus 로고
    • Comparison of interstudy reproducibility of cardiovascular magnetic resonance with 2-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy
    • Grothues F, Smith G, Moon J, et al. Comparison of interstudy reproducibility of cardiovascular magnetic resonance with 2-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 2002;90:29-34.
    • (2002) Am J Cardiol , vol.90 , pp. 29-34
    • Grothues, F.1    Smith, G.2    Moon, J.3
  • 24
    • 47249135718 scopus 로고    scopus 로고
    • Feasibility of single breath-hold left ventricular function with 3 Tesla TSENSE acquisition and 3D modeling analysis
    • Young A, Cowan B, Schoenberg S, Wintersperger B. Feasibility of single breath-hold left ventricular function with 3 Tesla TSENSE acquisition and 3D modeling analysis. J Cardiovasc Magn Reson 2008;10:24.
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 24
    • Young, A.1    Cowan, B.2    Schoenberg, S.3    Wintersperger, B.4
  • 25
    • 69949142546 scopus 로고    scopus 로고
    • Left ventricular dyssynchrony in patients with left bundle branch block and patients after myocardial infarction: Integration of mechanics and viability by cardiac magnetic resonance
    • Rutz AK, Manka R, Kozerke S, et al. Left ventricular dyssynchrony in patients with left bundle branch block and patients after myocardial infarction: integration of mechanics and viability by cardiac magnetic resonance. Eur Heart J 2009; 30:2117-27.
    • (2009) Eur Heart J , vol.30 , pp. 2117-2127
    • Rutz, A.K.1    Manka, R.2    Kozerke, S.3
  • 26
    • 84879412623 scopus 로고    scopus 로고
    • Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE
    • Feng L, Srichai MB, Lim RP, et al. Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE. Magn Reson Med 2013;70:64-74.
    • (2013) Magn Reson Med , vol.70 , pp. 64-74
    • Feng, L.1    Srichai, M.B.2    Lim, R.P.3
  • 27
    • 0035190823 scopus 로고    scopus 로고
    • Cine MRI using steady-state free precession in the radial long-axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle
    • Bloomer T, Plein S, Radjenovic A, et al. Cine MRI using steady-state free precession in the radial long-axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle. J Magn Reson Imaging 2001;14: 685-92.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 685-692
    • Bloomer, T.1    Plein, S.2    Radjenovic, A.3
  • 28
    • 0033302585 scopus 로고    scopus 로고
    • The influence of through-plane motion on left ventricular volumes measured by magnetic resonance imaging: Implications for image acquisition and analysis
    • Marcus J, Goette M, DeWaal L, et al. The influence of through-plane motion on left ventricular volumes measured by magnetic resonance imaging: implications for image acquisition and analysis. J Cardiovasc Magn Reson 1999;1:1-6.
    • (1999) J Cardiovasc Magn Reson , vol.1 , pp. 1-6
    • Marcus, J.1    Goette, M.2    Dewaal, L.3
  • 29
    • 84891391007 scopus 로고    scopus 로고
    • Quantification of aortic flow by phase-contrast magnetic resonance in patients with bicuspid aortic valve
    • Muzzarelli S, Monney P, O'Brien K, et al. Quantification of aortic flow by phase-contrast magnetic resonance in patients with bicuspid aortic valve. Eur Heart J Cardiovasc Imaging 2013; 15:77-84.
    • (2013) Eur Heart J Cardiovasc Imaging , vol.15 , pp. 77-84
    • Muzzarelli, S.1    Monney, P.2    O'brien, K.3
  • 30
    • 84877306053 scopus 로고    scopus 로고
    • Quantification of left ventricular trabeculae using fractal analysis
    • Captur G, Muthurangu V, Cook C, et al. Quantification of left ventricular trabeculae using fractal analysis. J Cardiovasc Magn Reson 2013; 15:36.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 36
    • Captur, G.1    Muthurangu, V.2    Cook, C.3
  • 31
    • 20744453356 scopus 로고    scopus 로고
    • Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging
    • Papavassiliu T, Kühl HP, Schröder M, et al. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology 2005; 236:57-64.
    • (2005) Radiology , vol.236 , pp. 57-64
    • Papavassiliu, T.1    Kühl, H.P.2    Schröder, M.3
  • 32
    • 0036104746 scopus 로고    scopus 로고
    • Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    • Moon J, Lorenz C, Francis J, Smith G, Pennell D. Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology 2002;223: 789-97.
    • (2002) Radiology , vol.223 , pp. 789-797
    • Moon, J.1    Lorenz, C.2    Francis, J.3    Smith, G.4    Pennell, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.