메뉴 건너뛰기




Volumn 4, Issue , 2014, Pages

Optical assay of erythrocyte function in banked blood

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN;

EID: 84922495421     PISSN: None     EISSN: 20452322     Source Type: Journal    
DOI: 10.1038/srep06211     Document Type: Article
Times cited : (41)

References (46)
  • 2
    • 36749038312 scopus 로고    scopus 로고
    • Evolution of adverse changes in stored RBCs
    • Bennett-Guerrero, E. et al. Evolution of adverse changes in stored RBCs. P Natl Acad Sci USA 104, 17063-17068 (2007).
    • (2007) P Natl Acad Sci USA , vol.104 , pp. 17063-17068
    • Bennett-Guerrero, E.1
  • 3
    • 77950542593 scopus 로고    scopus 로고
    • Bad blood: The risks of red cell storage
    • Lee, J. S. & Gladwin, M. T. Bad blood: the risks of red cell storage. Nat Med 16, 381-382 (2010).
    • (2010) Nat Med , vol.16 , pp. 381-382
    • Lee, J.S.1    Gladwin, M.T.2
  • 5
    • 17644431313 scopus 로고    scopus 로고
    • Fluctuation spectrum of fluid membranes coupled to an elastic meshwork: Jump of the effective surface tension at the mesh size
    • Fournier, J. B., Lacoste, D.&Raphael, E. Fluctuation spectrum of fluid membranes coupled to an elastic meshwork: jump of the effective surface tension at the mesh size. Phys Rev Lett 92, 018102 (2004).
    • (2004) Phys Rev Lett , vol.92 , pp. 018102
    • Fournier, J.B.1    Lacoste, D.2    Raphael, E.3
  • 6
    • 0034891566 scopus 로고    scopus 로고
    • Motion of red blood cells in a capillary with an endothelial surface layer: Effect of flow velocity
    • Secomb, T. W., Hsu, R. & Pries, A. R. Motion of red blood cells in a capillary with an endothelial surface layer: effect of flow velocity. AmJ Physiol Heart Circ Physiol 281, H629-636 (2001).
    • (2001) AmJ Physiol Heart Circ Physiol , vol.281 , pp. H629-636
    • Secomb, T.W.1    Hsu, R.2    Pries, A.R.3
  • 7
    • 84875360029 scopus 로고    scopus 로고
    • Age of red blood cells and transfusion in critically ill patients
    • Aubron, C., Nichol, A., Cooper, D. J. & Bellomo, R. Age of red blood cells and transfusion in critically ill patients. Ann Intensive Care 3, 2 (2013).
    • (2013) Ann Intensive Care , vol.3 , pp. 2
    • Aubron, C.1    Nichol, A.2    Cooper, D.J.3    Bellomo, R.4
  • 8
    • 0014576419 scopus 로고
    • Alteration of deformability of the erythrocyte membrane in stored blood
    • La Celle, P. L. Alteration of deformability of the erythrocyte membrane in stored blood. Transfusion 9, 238-245 (1969).
    • (1969) Transfusion , vol.9 , pp. 238-245
    • La Celle, P.L.1
  • 9
    • 84876770704 scopus 로고    scopus 로고
    • Decreased erythrocyte deformability after transfusion and the effects of erythrocyte storage duration
    • Frank, S. M. et al. Decreased erythrocyte deformability after transfusion and the effects of erythrocyte storage duration. Anesth Analg 116, 975-981 (2013).
    • (2013) Anesth Analg , vol.116 , pp. 975-981
    • Frank, S.M.1
  • 10
    • 77950221996 scopus 로고    scopus 로고
    • Is red blood cell rheology preserved during routine blood bank storage?
    • Henkelman, S. et al. Is red blood cell rheology preserved during routine blood bank storage? Transfusion 50, 941-948 (2010).
    • (2010) Transfusion , vol.50 , pp. 941-948
    • Henkelman, S.1
  • 11
    • 84891399763 scopus 로고    scopus 로고
    • Characterization of red blood cell deformability change during blood storage
    • Zheng, Y. et al. Characterization of red blood cell deformability change during blood storage. Lab Chip 14, 577-583 (2014).
    • (2014) Lab Chip , vol.14 , pp. 577-583
    • Zheng, Y.1
  • 12
    • 84890443965 scopus 로고    scopus 로고
    • Automated quantitative analysis of 3D morphology and mean corpuscular hemoglobin in human red blood cells stored in different periods
    • Moon, I. et al. Automated quantitative analysis of 3D morphology and mean corpuscular hemoglobin in human red blood cells stored in different periods. Opt Express 21, 30947-30957 (2013).
    • (2013) Opt Express , vol.21 , pp. 30947-30957
    • Moon, I.1
  • 13
    • 52949115297 scopus 로고    scopus 로고
    • Refractive index maps and membrane dynamics of human red blood cells parasitized by Plasmodium falciparum
    • Park, Y. K. et al. Refractive index maps and membrane dynamics of human red blood cells parasitized by Plasmodium falciparum. Proc Natl Acad Sci U S A 105, 13730 (2008).
    • (2008) Proc Natl Acad Sci U S A , vol.105 , pp. 13730
    • Park, Y.K.1
  • 14
    • 76549120274 scopus 로고    scopus 로고
    • Metabolic remodeling of the human red blood cell membran
    • Park, Y. K. et al. Metabolic remodeling of the human red blood cell membran. Proc. Nat. Acad. Sci. 107, 1289 (2010).
    • (2010) Proc. Nat. Acad. Sci. , vol.107 , pp. 1289
    • Park, Y.K.1
  • 15
    • 77951046170 scopus 로고    scopus 로고
    • Measurement of red blood cell mechanics during morphological changes
    • Park, Y. K. et al.Measurement of red blood cell mechanics during morphological changes. Proc. Nat. Acad. Sci. 107, 6731 (2010).
    • (2010) Proc. Nat. Acad. Sci. , vol.107 , pp. 6731
    • Park, Y.K.1
  • 18
    • 84858591344 scopus 로고    scopus 로고
    • Diffraction phase microscopy with white light
    • Bhaduri, B., Pham, H., Mir, M. & Popescu, G. Diffraction phase microscopy with white light. Opt. Lett. 37, 1094-1096 (2012).
    • (2012) Opt. Lett. , vol.37 , pp. 1094-1096
    • Bhaduri, B.1    Pham, H.2    Mir, M.3    Popescu, G.4
  • 19
  • 20
    • 84897584855 scopus 로고    scopus 로고
    • White-light diffraction tomography of unlabelled live cells
    • Kim, T. et al. White-light diffraction tomography of unlabelled live cells. Nat Photon 8, 256-263, doi:10.1038/nphoton.2013.350 (2014).
    • (2014) Nat Photon , vol.8 , pp. 256-263
    • Kim, T.1
  • 21
    • 84874085124 scopus 로고    scopus 로고
    • Cardiomyocyte Imaging Using Real-Time Spatial Light Interference Microscopy (SLIM)
    • Bhaduri, B. et al. Cardiomyocyte Imaging Using Real-Time Spatial Light Interference Microscopy (SLIM). PLoS One 8, e56930 (2013).
    • (2013) PLoS One , vol.8
    • Bhaduri, B.1
  • 22
    • 79959479613 scopus 로고    scopus 로고
    • Measuring the scattering parameters of tissues from quantitative phase imaging of thin slices
    • Ding, H. et al. Measuring the scattering parameters of tissues from quantitative phase imaging of thin slices. Opt Lett 36, 2281-2283 (2011).
    • (2011) Opt Lett , vol.36 , pp. 2281-2283
    • Ding, H.1
  • 24
    • 84859416786 scopus 로고    scopus 로고
    • Tissue refractive index as marker of disease
    • Wang, Z., Tangella, K., Balla, A.&Popescu, G. Tissue refractive index as marker of disease. J Biomed Opt 16, 116017 (2011).
    • (2011) J Biomed Opt , vol.16 , pp. 116017
    • Wang, Z.1    Tangella, K.2    Balla, A.3    Popescu, G.4
  • 25
    • 83155173506 scopus 로고    scopus 로고
    • High-resolution full-field optical coherence microscopy using a Mirau interferometer for the quantitative imaging of biological cells
    • Anna, T., Srivastava, V., Mehta, D. S. & Shakher, C. High-resolution full-field optical coherence microscopy using a Mirau interferometer for the quantitative imaging of biological cells. Appl Optics 50, 6343-6351 (2011).
    • (2011) Appl Optics , vol.50 , pp. 6343-6351
    • Anna, T.1    Srivastava, V.2    Mehta, D.S.3    Shakher, C.4
  • 26
    • 84870015802 scopus 로고    scopus 로고
    • Quantitative phase imaging of human red blood cells using phase-shifting white light interference microscopy with colour fringe analysis
    • Mehta, D. S. & Srivastava, V.Quantitative phase imaging of human red blood cells using phase-shifting white light interference microscopy with colour fringe analysis. Appl Phys Lett 101 (2012).
    • (2012) Appl Phys Lett , vol.101
    • Mehta, D.S.1    Srivastava, V.2
  • 27
    • 84861140760 scopus 로고    scopus 로고
    • Dynamic spectroscopic phase microscopy for quantifying hemoglobin concentration and dynamic membrane fluctuation in red blood cells
    • Jang, Y., Jang, J. & Park, Y. Dynamic spectroscopic phase microscopy for quantifying hemoglobin concentration and dynamic membrane fluctuation in red blood cells. Opt Express 20, 9673-9681 (2012).
    • (2012) Opt Express , vol.20 , pp. 9673-9681
    • Jang, Y.1    Jang, J.2    Park, Y.3
  • 28
    • 79955156728 scopus 로고    scopus 로고
    • Reflective interferometric chamber for quantitative phase imaging of biological sample dynamics
    • Shaked, N. T., Zhu, Y. Z., Badie, N., Bursac, N. & Wax, A. Reflective interferometric chamber for quantitative phase imaging of biological sample dynamics. J Biomed Opt 15 (2010).
    • (2010) J Biomed Opt , vol.15
    • Shaked, N.T.1    Zhu, Y.Z.2    Badie, N.3    Bursac, N.4    Wax, A.5
  • 29
    • 14844322300 scopus 로고    scopus 로고
    • Digital holographic microscopy: A noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy
    • Marquet, P. et al. Digital holographic microscopy: a noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy. Opt Lett 30, 468-470 (2005).
    • (2005) Opt Lett , vol.30 , pp. 468-470
    • Marquet, P.1
  • 30
    • 33645749891 scopus 로고    scopus 로고
    • Diffraction phase microscopy for quantifying cell structure and dynamics
    • Popescu, G., Ikeda, T.,Dasari, R. R. & Feld, M. S. Diffraction phase microscopy for quantifying cell structure and dynamics. Opt Lett 31, 775-777 (2006).
    • (2006) Opt Lett , vol.31 , pp. 775-777
    • Popescu, G.1    Ikeda, T.2    Dasari, R.R.3    Feld, M.S.4
  • 31
    • 20444410067 scopus 로고    scopus 로고
    • Hilbert phase microscopy for investigating fast dynamics in transparent systems
    • Ikeda, T., Popescu, G., Dasari, R. R. & Feld, M. S. Hilbert phase microscopy for investigating fast dynamics in transparent systems. Opt Lett 30, 1165-1167 (2005).
    • (2005) Opt Lett , vol.30 , pp. 1165-1167
    • Ikeda, T.1    Popescu, G.2    Dasari, R.R.3    Feld, M.S.4
  • 32
    • 9144273300 scopus 로고    scopus 로고
    • Fourier phase microscopy for investigation of biological structures and dynamics
    • Popescu, G. et al. Fourier phase microscopy for investigation of biological structures and dynamics. Opt Lett 29, 2503-2505 (2004).
    • (2004) Opt Lett , vol.29 , pp. 2503-2505
    • Popescu, G.1
  • 34
    • 27544435170 scopus 로고    scopus 로고
    • High-resolution quantitative phasecontrast microscopy by digital holography
    • Mann, C. J., Yu, L. F., Lo, C.M. & Kim, M. K. High-resolution quantitative phasecontrast microscopy by digital holography. Opt Express 13, 8693-8698 (2005).
    • (2005) Opt Express , vol.13 , pp. 8693-8698
    • Mann, C.J.1    Yu, L.F.2    Lo, C.M.3    Kim, M.K.4
  • 35
    • 76449112403 scopus 로고    scopus 로고
    • Quantitative phase imaging with broadband fields
    • Wang, Z. & Popescu, G. Quantitative phase imaging with broadband fields. Appl Phys Lett 96 (2010).
    • (2010) Appl Phys Lett , vol.96
    • Wang, Z.1    Popescu, G.2
  • 36
    • 78751523507 scopus 로고    scopus 로고
    • Spatial light interference microscopy (SLIM)
    • Wang, Z. et al. Spatial light interference microscopy (SLIM). Opt Express 19, 1016-1026 (2011).
    • (2011) Opt Express , vol.19 , pp. 1016-1026
    • Wang, Z.1
  • 37
    • 33745755109 scopus 로고
    • Phase contrast, a new method for the microscopic observation of transparent objects
    • Zernike, F. Phase contrast, a new method for the microscopic observation of transparent objects. Physica 9, 686-698 (1942).
    • (1942) Physica , vol.9 , pp. 686-698
    • Zernike, F.1
  • 38
    • 34250769340 scopus 로고
    • A new microscopic principle
    • Gabor, D. A new microscopic principle. Nature 161, 777-778 (1948).
    • (1948) Nature , vol.161 , pp. 777-778
    • Gabor, D.1
  • 39
    • 77951046170 scopus 로고    scopus 로고
    • Measurement of red blood cell mechanics during morphological changes
    • Park, Y. et al. Measurement of red blood cell mechanics during morphological changes. P Natl Acad Sci USA 107, 6731-6736, doi:10.1073/pnas.0909533107 (2010).
    • (2010) P Natl Acad Sci USA , vol.107 , pp. 6731-6736
    • Park, Y.1
  • 40
    • 60549102702 scopus 로고    scopus 로고
    • Diffraction Phase Cytometry: Blood on a CD-ROM
    • Mir, M.,Wang, Z., Tangella, K. & Popescu, G.Diffraction Phase Cytometry: blood on a CD-ROM. Opt Express 17, 2579-2585 (2009).
    • (2009) Opt Express , vol.17 , pp. 2579-2585
    • Mir, M.1    Wang, Z.2    Tangella, K.3    Popescu, G.4
  • 41
    • 0000123864 scopus 로고
    • Interference microscopy and mass determination
    • Barer, R. Interference microscopy and mass determination. Nature 169, 366 (1952).
    • (1952) Nature , vol.169 , pp. 366
    • Barer, R.1
  • 42
    • 36549059956 scopus 로고
    • Interference microscopy and mass determination
    • Davies, H. & Wilkins, M. Interference microscopy and mass determination. Nature 169, 541 (1952).
    • (1952) Nature , vol.169 , pp. 541
    • Davies, H.1    Wilkins, M.2
  • 43
    • 33745159952 scopus 로고    scopus 로고
    • Model function to calculate the refractive index of native hemoglobin in the wavelength range of 250-1100 nm dependent on concentration
    • Friebel, M.&Meinke, M. Model function to calculate the refractive index of native hemoglobin in the wavelength range of 250-1100 nm dependent on concentration. Appl Optics 45, 2838-2842 (2006).
    • (2006) Appl Optics , vol.45 , pp. 2838-2842
    • Friebel, M.1    Meinke, M.2
  • 44
    • 0026528393 scopus 로고
    • Effect of irradiation on red cell cation content and transport
    • Brugnara, C.&Churchill, W. H. Effect of irradiation on red cell cation content and transport. Transfusion 32, 246-252 (1992).
    • (1992) Transfusion , vol.32 , pp. 246-252
    • Brugnara, C.1    Churchill, W.H.2
  • 45
    • 33751263668 scopus 로고    scopus 로고
    • Optical measurement of cell membrane tension
    • Popescu, G. et al.Optical measurement of cell membrane tension. Phys Rev Lett 97 (2006).
    • (2006) Phys Rev Lett , vol.97
    • Popescu, G.1
  • 46
    • 77949291119 scopus 로고    scopus 로고
    • A 5.5 M pixel 100 frames/sec wide dynamic range low noise CMOS image sensor for scientific applications
    • Fowler, B. C. L., Mims, S., Balicki, J., Li, W., Do, H., Appelbaum, J. & Vu, P. A 5.5 M pixel 100 Frames/sec Wide Dynamic Range Low Noise CMOS Image Sensor for Scientific Applications. Proc. SPIE 7536, 12 (2010).
    • (2010) Proc. SPIE , vol.7536 , pp. 12
    • Fowler, B.C.L.1    Mims, S.2    Balicki, J.3    Li, W.4    Do, H.5    Appelbaum, J.6    Vu, P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.