메뉴 건너뛰기




Volumn 8, Issue 6, 2014, Pages 459-467

A simplified D-shaped model of the mitral annulus to facilitate CT-based sizing before transcatheter mitral valve implantation

Author keywords

Computed tomography; Mitral annulus; Mitral regurgitation; Transapical mitral valve replacement; Transcatheter mitral valve implantation

Indexed keywords

AGED; ANATOMIC MODEL; ARTICLE; CLINICAL ASSESSMENT; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; D SHAPED MODEL MITRAL ANNULUS; ELECTROCARDIOGRAM; FEMALE; HEART LEFT VENTRICLE OUTFLOW TRACT; HUMAN; IMAGING SOFTWARE; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE; MITRAL VALVE REGURGITATION; MITRAL VALVE REPLACEMENT; PRIORITY JOURNAL; TRANSCATHETER MITRAL VALVE IMPLANTATION; BIOLOGICAL MODEL; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; DEVICES; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; MIDDLE AGED; MITRAL VALVE INSUFFICIENCY; PATHOPHYSIOLOGY; PREDICTIVE VALUE; PROCEDURES; PROSTHESIS; RADIOGRAPHY; REPRODUCIBILITY; RETROSPECTIVE STUDY; SEVERITY OF ILLNESS INDEX; VERY ELDERLY;

EID: 84922343501     PISSN: 19345925     EISSN: 1876861X     Source Type: Journal    
DOI: 10.1016/j.jcct.2014.09.009     Document Type: Article
Times cited : (118)

References (20)
  • 1
    • 84894353245 scopus 로고    scopus 로고
    • Transapical mitral implantation of the Tiara bioprosthesis: pre-clinical results
    • Banai S., Verheye S., Cheung A., et al. Transapical mitral implantation of the Tiara bioprosthesis: pre-clinical results. JACC Cardiovasc Interv 2014, 7:154-162.
    • (2014) JACC Cardiovasc Interv , vol.7 , pp. 154-162
    • Banai, S.1    Verheye, S.2    Cheung, A.3
  • 2
    • 84922358779 scopus 로고    scopus 로고
    • Neovasc Inc. Press release Neovasc Inc., Richmond, BC
    • Neovasc Inc. Press release Neovasc Inc., Richmond, BC .2014. http://www.neovasc.com/wp-content/uploads/2014/02/Neovasc_Tiara_First_in_Human.pdf.
    • (2014)
  • 3
    • 84867081029 scopus 로고    scopus 로고
    • Tiara: a novel catheter-based mitral valve bioprosthesis: initial experiments and short-term pre-clinical results
    • Banai S., Jolicoeur E.M., Schwartz M., et al. Tiara: a novel catheter-based mitral valve bioprosthesis: initial experiments and short-term pre-clinical results. JAm Coll Cardiol 2012, 60:1430-1431.
    • (2012) JAm Coll Cardiol , vol.60 , pp. 1430-1431
    • Banai, S.1    Jolicoeur, E.M.2    Schwartz, M.3
  • 4
    • 0024423585 scopus 로고
    • Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse
    • Levine R.A., Handschumacher M.D., Sanfilippo A.J., et al. Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse. Circulation 1989, 80:589-598.
    • (1989) Circulation , vol.80 , pp. 589-598
    • Levine, R.A.1    Handschumacher, M.D.2    Sanfilippo, A.J.3
  • 5
    • 0033998965 scopus 로고    scopus 로고
    • Analysis of shape and motion of the mitral annulus in subjects with and without cardiomyopathy by echocardiographic 3-dimensional reconstruction
    • Flachskampf F.A., Chandra S., Gaddipatti A., et al. Analysis of shape and motion of the mitral annulus in subjects with and without cardiomyopathy by echocardiographic 3-dimensional reconstruction. JAm Soc Echocardiogr 2000, 13:277-287.
    • (2000) JAm Soc Echocardiogr , vol.13 , pp. 277-287
    • Flachskampf, F.A.1    Chandra, S.2    Gaddipatti, A.3
  • 6
    • 67651087220 scopus 로고    scopus 로고
    • Mitral annular shape, size, and motion in normals and in patients with cardiomyopathy: evaluation with computed tomography
    • Alkadhi H., Desbiolles L., Stolzmann P., et al. Mitral annular shape, size, and motion in normals and in patients with cardiomyopathy: evaluation with computed tomography. Invest Radiol 2009, 44:218-225.
    • (2009) Invest Radiol , vol.44 , pp. 218-225
    • Alkadhi, H.1    Desbiolles, L.2    Stolzmann, P.3
  • 7
    • 84874078736 scopus 로고    scopus 로고
    • Quantitative analysis of mitral valve morphology in mitral valve prolapse with real-time 3-dimensional echocardiography: importance of annular saddle shape in the pathogenesis of mitral regurgitation
    • Lee A.P., Hsiung M.C., Salgo I.S., et al. Quantitative analysis of mitral valve morphology in mitral valve prolapse with real-time 3-dimensional echocardiography: importance of annular saddle shape in the pathogenesis of mitral regurgitation. Circulation 2013, 127:832-841.
    • (2013) Circulation , vol.127 , pp. 832-841
    • Lee, A.P.1    Hsiung, M.C.2    Salgo, I.S.3
  • 8
    • 84891629495 scopus 로고    scopus 로고
    • Regional annular geometry in patients with mitral regurgitation: implications for annuloplasty ring selection
    • Jassar A.S., Vergnat M., Jackson B.M., et al. Regional annular geometry in patients with mitral regurgitation: implications for annuloplasty ring selection. Ann Thorac Surg 2014, 97:64-70.
    • (2014) Ann Thorac Surg , vol.97 , pp. 64-70
    • Jassar, A.S.1    Vergnat, M.2    Jackson, B.M.3
  • 9
    • 84898802770 scopus 로고    scopus 로고
    • Sizing the mitral annulus in healthy subjects and patients with mitral regurgitation: 2D versus 3D measurements from cardiac CT
    • Gordic S., Nguyen-Kim T.D., Manka R., et al. Sizing the mitral annulus in healthy subjects and patients with mitral regurgitation: 2D versus 3D measurements from cardiac CT. Int J Cardiovasc Imaging 2014, 30:389-398.
    • (2014) Int J Cardiovasc Imaging , vol.30 , pp. 389-398
    • Gordic, S.1    Nguyen-Kim, T.D.2    Manka, R.3
  • 10
    • 0036839367 scopus 로고    scopus 로고
    • Anatomy of the mitral valve
    • Ho S.Y. Anatomy of the mitral valve. Heart 2002, 88(Suppl 4):iv5-iv10.
    • (2002) Heart , vol.88 , pp. iv5-iv10
    • Ho, S.Y.1
  • 11
    • 0031898051 scopus 로고    scopus 로고
    • Three-dimensional measurement of the mitral annulus by multiplane transesophageal echocardiography: invitro validation and invivo demonstration
    • Legget M.E., Bashein G., McDonald J.A., et al. Three-dimensional measurement of the mitral annulus by multiplane transesophageal echocardiography: invitro validation and invivo demonstration. JAm Soc Echocardiogr 1998, 11:188-200.
    • (1998) JAm Soc Echocardiogr , vol.11 , pp. 188-200
    • Legget, M.E.1    Bashein, G.2    McDonald, J.A.3
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 84908126520 scopus 로고    scopus 로고
    • First-in-Human Off-Pump Transcatheter Mitral Vlave Replacment
    • Lutter G., Lozonschi L., Ebner A., et al. First-in-Human Off-Pump Transcatheter Mitral Vlave Replacment. JACC Cardiovasc Interv 2014, 7:1077-1078.
    • (2014) JACC Cardiovasc Interv , vol.7 , pp. 1077-1078
    • Lutter, G.1    Lozonschi, L.2    Ebner, A.3
  • 14
    • 65549124053 scopus 로고    scopus 로고
    • Assessment of mitral valve anatomy and geometry with multislice computed tomography
    • Delgado V., Tops L.F., Schuijf J.D., et al. Assessment of mitral valve anatomy and geometry with multislice computed tomography. JACC Cardiovasc Imaging 2009, 2:556-565.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 556-565
    • Delgado, V.1    Tops, L.F.2    Schuijf, J.D.3
  • 15
    • 84863180193 scopus 로고    scopus 로고
    • Mechanism of asymmetric leaflet tethering in ischemic mitral regurgitation: 3D analysis with multislice CT
    • Kim K., Kaji S., An Y., et al. Mechanism of asymmetric leaflet tethering in ischemic mitral regurgitation: 3D analysis with multislice CT. JACC Cardiovasc Imaging 2012, 5:230-232.
    • (2012) JACC Cardiovasc Imaging , vol.5 , pp. 230-232
    • Kim, K.1    Kaji, S.2    An, Y.3
  • 16
    • 84884491914 scopus 로고    scopus 로고
    • Assessment of mitral valve adaptation with gated cardiac computed tomography: validation with three-dimensional echocardiography and mechanistic insight to functional mitral regurgitation
    • Beaudoin J., Thai W.E., Wai B., Handschumacher M.D., Levine R.A., Truong Q.A. Assessment of mitral valve adaptation with gated cardiac computed tomography: validation with three-dimensional echocardiography and mechanistic insight to functional mitral regurgitation. Circ Cardiovasc Imaging 2013, 6:784-789.
    • (2013) Circ Cardiovasc Imaging , vol.6 , pp. 784-789
    • Beaudoin, J.1    Thai, W.E.2    Wai, B.3    Handschumacher, M.D.4    Levine, R.A.5    Truong, Q.A.6
  • 17
    • 81855227692 scopus 로고    scopus 로고
    • Aortic annulus diameter determination by multidetector computed tomography reproducibility, applicability, and implications for transcatheter aortic valve implantation
    • Gurvitch R., Webb J.G., Yuan R., et al. Aortic annulus diameter determination by multidetector computed tomography reproducibility, applicability, and implications for transcatheter aortic valve implantation. JAm Coll Cardiol Intv 2011, 4:1235-1245.
    • (2011) JAm Coll Cardiol Intv , vol.4 , pp. 1235-1245
    • Gurvitch, R.1    Webb, J.G.2    Yuan, R.3
  • 18
    • 78649323412 scopus 로고    scopus 로고
    • Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method
    • Blanke P., Siepe M., Reinohl J., et al. Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method. Eur J Cardiothorac Surg 2010, 38:750-758.
    • (2010) Eur J Cardiothorac Surg , vol.38 , pp. 750-758
    • Blanke, P.1    Siepe, M.2    Reinohl, J.3
  • 19
    • 84859160648 scopus 로고    scopus 로고
    • 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis
    • Willson A.B., Webb J.G., Labounty T.M., et al. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. JAm Coll Cardiol 2012, 59:1287-1294.
    • (2012) JAm Coll Cardiol , vol.59 , pp. 1287-1294
    • Willson, A.B.1    Webb, J.G.2    Labounty, T.M.3
  • 20
    • 84866379958 scopus 로고    scopus 로고
    • Conformational pulsatilechanges of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement
    • Blanke P., Russe M., Leipsic J., et al. Conformational pulsatilechanges of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement. JACC Cardiovasc Interv 2012, 5:984-994.
    • (2012) JACC Cardiovasc Interv , vol.5 , pp. 984-994
    • Blanke, P.1    Russe, M.2    Leipsic, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.