메뉴 건너뛰기




Volumn 149, Issue 1, 2015, Pages 247-255

Flow simulations and validation for the first cohort of patients undergoing the Y-graft Fontan procedure

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CASE REPORT; COHORT ANALYSIS; COMPUTATIONAL FLUID DYNAMICS; FONTAN PROCEDURE; HUMAN; LIVER BLOOD FLOW; LUNG PERFUSION; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTOPERATIVE CARE; PRIORITY JOURNAL; SHEAR STRESS; SIMULATION; THROMBOSIS; Y GRAFT FONTAN PROCEDURE; BIOLOGICAL MODEL; BLOOD FLOW; BLOOD VESSEL PROSTHESIS; BLOOD VESSEL TRANSPLANTATION; COMPUTER SIMULATION; HEART DEFECTS, CONGENITAL; HEMODYNAMICS; INFERIOR CAVA VEIN; LIVER CIRCULATION; LUNG CIRCULATION; PATHOPHYSIOLOGY; PROSTHESIS; PULMONARY ARTERY; RADIOGRAPHY; TIME; TREATMENT OUTCOME; VALIDATION STUDY;

EID: 84922332723     PISSN: 00225223     EISSN: 1097685X     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2014.08.069     Document Type: Article
Times cited : (61)

References (31)
  • 1
    • 20444491226 scopus 로고    scopus 로고
    • The Fontan circulation: A challenge to William Harvey?
    • de Leval MR. The Fontan circulation: a challenge to William Harvey? Nat Clin Pract Cardiovasc Med. 2005;2:202-8.
    • (2005) Nat Clin Pract Cardiovasc Med. , vol.2 , pp. 202-208
    • De Leval, M.R.1
  • 2
    • 0030068248 scopus 로고    scopus 로고
    • A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection
    • Dubini G, de Leval MR, Pietrabissa R, Montevecchi FM, Fumero R. A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection. J Biomech. 1996;29:111-21.
    • (1996) J Biomech. , vol.29 , pp. 111-121
    • Dubini, G.1    De Leval, M.R.2    Pietrabissa, R.3    Montevecchi, F.M.4    Fumero, R.5
  • 6
    • 78650179076 scopus 로고    scopus 로고
    • Imaging and patientspecific simulations for the Fontan surgery: Current methodologies and clinical applications
    • De Zelicourt DA, Marsden AL, Fogel MA, Yoganathan AP. Imaging and patientspecific simulations for the Fontan surgery: current methodologies and clinical applications. Prog Pediatr Cardiol. 2010;30:31-44.
    • (2010) Prog Pediatr Cardiol. , vol.30 , pp. 31-44
    • De Zelicourt, D.A.1    Marsden, A.L.2    Fogel, M.A.3    Yoganathan, A.P.4
  • 8
    • 33846307817 scopus 로고    scopus 로고
    • Effects of exercise and respiration on the hemodynamic efficiency of the total cavopulmonary connection
    • Marsden AL, Vignon-Clementel IE, Chan F, Feinstein JA, Taylor CA. Effects of exercise and respiration on the hemodynamic efficiency of the total cavopulmonary connection. Ann Biomed Eng. 2007;35:250-63.
    • (2007) Ann Biomed Eng. , vol.35 , pp. 250-263
    • Marsden, A.L.1    Vignon-Clementel, I.E.2    Chan, F.3    Feinstein, J.A.4    Taylor, C.A.5
  • 9
    • 77953616515 scopus 로고    scopus 로고
    • Constrained optimization of an idealized Yshaped baffle for the Fontan surgery at rest and exercise
    • Yang W, Feinstein JA, Marsden AL. Constrained optimization of an idealized Yshaped baffle for the Fontan surgery at rest and exercise. Comput Meth Appl Mech Eng. 2010;199:2135-49.
    • (2010) Comput Meth Appl Mech Eng. , vol.199 , pp. 2135-2149
    • Yang, W.1    Feinstein, J.A.2    Marsden, A.L.3
  • 10
    • 84859772737 scopus 로고    scopus 로고
    • Hepatic blood flow distribution and performance in conventional and novel Y-graft Fontan geometries: A case series computational fluid dynamics study
    • Yang W, Vignon-Clementel IE, Troianowski G, Reddy VM, Feinstein JA, Marsden AL. Hepatic blood flow distribution and performance in conventional and novel Y-graft Fontan geometries: a case series computational fluid dynamics study. J Thorac Cardiovasc Surg. 2012;143:1086-97.
    • (2012) J Thorac Cardiovasc Surg. , vol.143 , pp. 1086-1097
    • Yang, W.1    Vignon-Clementel, I.E.2    Troianowski, G.3    Reddy, V.M.4    Feinstein, J.A.5    Marsden, A.L.6
  • 12
    • 84922407076 scopus 로고    scopus 로고
    • Technical feasibility and intermediate outcomes of a hand-crafted, area-preserving, bifurcated "Y-graft" Fontan
    • Martin MH, Feinstein JA, Chan FP, Marsden AL, Yang W, Reddy VM. Technical feasibility and intermediate outcomes of a hand-crafted, area-preserving, bifurcated "Y-graft" Fontan. J Thorac Cardiovasc Surg. 2015;149:249-55.
    • (2015) J Thorac Cardiovasc Surg. , vol.149 , pp. 249-255
    • Martin, M.H.1    Feinstein, J.A.2    Chan, F.P.3    Marsden, A.L.4    Yang, W.5    Reddy, V.M.6
  • 13
    • 33748581912 scopus 로고    scopus 로고
    • Relative lung perfusion distribution in normal lung scans: Observation and clinical implications
    • Cheng CP, Taur AS, Lee GS, Goris ML, Feinstein JA. Relative lung perfusion distribution in normal lung scans: observation and clinical implications. Congenit Heart Dis. 2006;1:210-6.
    • (2006) Congenit Heart Dis. , vol.1 , pp. 210-216
    • Cheng, C.P.1    Taur, A.S.2    Lee, G.S.3    Goris, M.L.4    Feinstein, J.A.5
  • 16
    • 33846307817 scopus 로고    scopus 로고
    • Effects of exercise and respiration on hemodynamic efficiency in CFD simulations of the total cavopulmonary connection
    • Marsden AL, Vignon-Clementel IE, Chan FP, Feinstein JA, Taylor CA. Effects of exercise and respiration on hemodynamic efficiency in CFD simulations of the total cavopulmonary connection. Ann Biomed Eng. 2007;35: 250-63.
    • (2007) Ann Biomed Eng. , vol.35 , pp. 250-263
    • Marsden, A.L.1    Vignon-Clementel, I.E.2    Chan, F.P.3    Feinstein, J.A.4    Taylor, C.A.5
  • 17
    • 82955195078 scopus 로고    scopus 로고
    • Three-dimensional simulations in Glenn patients: Clinically based boundary conditions, hemodynamic results and sensitivity to input data
    • Troianowski G, Taylor CA, Feinstein JA, Vignon-Clementel I. Three-dimensional simulations in Glenn patients: clinically based boundary conditions, hemodynamic results and sensitivity to input data. J Biomech Eng. 2011;133: 111006.
    • (2011) J Biomech Eng. , vol.133 , pp. 111006
    • Troianowski, G.1    Taylor, C.A.2    Feinstein, J.A.3    Vignon-Clementel, I.4
  • 18
    • 0030958062 scopus 로고    scopus 로고
    • Lung perfusion patterns after bidirectional cavopulmonary anastomosis (hemi-Fontan procedure)
    • Seliem MA, Murphy J, Vetter J, Heyman S, Norwood W. Lung perfusion patterns after bidirectional cavopulmonary anastomosis (hemi-Fontan procedure). Pediatr Cardiol. 1997;18:191-6.
    • (1997) Pediatr Cardiol. , vol.18 , pp. 191-196
    • Seliem, M.A.1    Murphy, J.2    Vetter, J.3    Heyman, S.4    Norwood, W.5
  • 19
    • 44649107730 scopus 로고    scopus 로고
    • Characterization of coherent structures in the cardiovascular system
    • Shadden SC, Taylor CA. Characterization of coherent structures in the cardiovascular system. Ann Biomed Eng. 2008;36:1152-62.
    • (2008) Ann Biomed Eng. , vol.36 , pp. 1152-1162
    • Shadden, S.C.1    Taylor, C.A.2
  • 21
    • 0033537660 scopus 로고    scopus 로고
    • Caval contribution to flow in the branch pulmonary arteries of Fontan patients with a novel application of magnetic resonance presaturation pulse
    • Fogel MA, Weinberg PM, Rychik J, Hubbard A, Jacobs M, Spray TL, et al. Caval contribution to flow in the branch pulmonary arteries of Fontan patients with a novel application of magnetic resonance presaturation pulse. Circulation. 1999;99:1215-21.
    • (1999) Circulation , vol.99 , pp. 1215-1221
    • Fogel, M.A.1    Weinberg, P.M.2    Rychik, J.3    Hubbard, A.4    Jacobs, M.5    Spray, T.L.6
  • 23
    • 0242552136 scopus 로고    scopus 로고
    • Pulmonary arteriovenous malformations after cavopulmonary anastomosis
    • Duncan BW, Desai S. Pulmonary arteriovenous malformations after cavopulmonary anastomosis. Ann Thorac Surg. 2003;76:1759-66.
    • (2003) Ann Thorac Surg. , vol.76 , pp. 1759-1766
    • Duncan, B.W.1    Desai, S.2
  • 24
    • 3242781894 scopus 로고    scopus 로고
    • Regression of severe pulmonary arteriovenous malformations after Fontan revision and "hepatic factor" rerouting
    • Pike NA, Vricella LA, Feinstein JA, Black MD, Reitz BA. Regression of severe pulmonary arteriovenous malformations after Fontan revision and "hepatic factor" rerouting. Ann Thorac Surg. 2004;78:697-9.
    • (2004) Ann Thorac Surg. , vol.78 , pp. 697-699
    • Pike, N.A.1    Vricella, L.A.2    Feinstein, J.A.3    Black, M.D.4    Reitz, B.A.5
  • 25
    • 33747095206 scopus 로고    scopus 로고
    • Redirection of the hepatic venous flow for the treatment of pulmonary arteriovenous malformations after Fontan operation
    • Imoto Y, Sese A, Joh K. Redirection of the hepatic venous flow for the treatment of pulmonary arteriovenous malformations after Fontan operation. Pediatr Cardiol. 2006;27:490-2.
    • (2006) Pediatr Cardiol. , vol.27 , pp. 490-492
    • Imoto, Y.1    Sese, A.2    Joh, K.3
  • 26
    • 84862975364 scopus 로고    scopus 로고
    • Radionuclide and angiographic assessment of pulmonary perfusion after Fontan procedure: Comparative interim outcomes
    • Yin Z, Wang H, Wang Z, Zhu H, Zhang R, Hou M, et al. Radionuclide and angiographic assessment of pulmonary perfusion after Fontan procedure: comparative interim outcomes. Ann Thorac Surg. 2012;93:620-5.
    • (2012) Ann Thorac Surg. , vol.93 , pp. 620-625
    • Yin, Z.1    Wang, H.2    Wang, Z.3    Zhu, H.4    Zhang, R.5    Hou, M.6
  • 27
    • 84871895129 scopus 로고    scopus 로고
    • Optimization of a Y-graft design for improved hepatic flow distribution in the Fontan circulation
    • Yang W, Feinstein JA, Shadden SC, Vignon-Clementel IE, Marsden AL. Optimization of a Y-graft design for improved hepatic flow distribution in the Fontan circulation. J Biomech Eng. 2013;135:011002.
    • (2013) J Biomech Eng. , vol.135 , pp. 011002
    • Yang, W.1    Feinstein, J.A.2    Shadden, S.C.3    Vignon-Clementel, I.E.4    Marsden, A.L.5
  • 31
    • 70349659157 scopus 로고    scopus 로고
    • Computational fluid-structure interaction: Methods and application to a total cavopulmonary connection
    • Bazilevs Y, Hsu M-C, Besnon DJ, Sankaran S, Marsden AL. Computational fluid-structure interaction: methods and application to a total cavopulmonary connection. Comput Mech. 2008;45:77-89.
    • (2008) Comput Mech. , vol.45 , pp. 77-89
    • Bazilevs, Y.1    Hsu, M.-C.2    Besnon, D.J.3    Sankaran, S.4    Marsden, A.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.