메뉴 건너뛰기




Volumn 135, Issue 1, 2013, Pages

Optimization of a Y-Graft design for improved hepatic flow distribution in the fontan circulation

Author keywords

blood flow simulation; Fontan; hepatic flow distribution (HFD); optimization; surgical design; Y graft

Indexed keywords

BLOOD FLOW SIMULATIONS; BRANCH DIAMETER; CONGENITAL HEART DISEASE; DESIGN OPTIMIZATION; FLOW DISTRIBUTION; FLOW SPLITS; FONTAN; HEART DEFECTS; INFERIOR VENA CAVA; LAGRANGIAN PARTICLE TRACKING; OPTIMAL DESIGN; PATIENT MODELS; PROXIMAL ANASTOMOSIS; PULMONARY ARTERY; PULMONARY FLOW; SUPERIOR VENA CAVA; Y-GRAFT;

EID: 84871895129     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.4023089     Document Type: Article
Times cited : (50)

References (47)
  • 1
    • 20444491226 scopus 로고    scopus 로고
    • The fontan circulation: A challenge to williamharvey?
    • de Leval, M. R., 2005, "The Fontan Circulation: A Challenge to WilliamHarvey?" Nat. Clin. Pract. Cardiovasc. Med., 2, pp. 202-208.
    • (2005) Nat. Clin. Pract. Cardiovasc. Med , vol.2 , pp. 202-208
    • De Leval, M.R.1
  • 2
    • 0036785439 scopus 로고    scopus 로고
    • Outcomes after the fontan procedure
    • Marino, B. S., 2002. "Outcomes After the Fontan Procedure," Curr. Opin.Pediatr., 14, pp. 620-626.
    • (2002) Curr. Opin.Pediatr , vol.14 , pp. 620-626
    • Marino, B.S.1
  • 4
    • 0242552136 scopus 로고    scopus 로고
    • Pulmonary arteriovenous malformations after cavopulmonary anastomosis
    • DOI 10.1016/S0003-4975(03)00450-8
    • Duncan, B. W. and Desai, S., 2003. "Pulmonary Arteriovenous MalformationsAfter Cavopulmonary Anastomosis," Ann. Thorac. Surg., 76, pp. 1759-1766. (Pubitemid 37378366)
    • (2003) Annals of Thoracic Surgery , vol.76 , Issue.5 , pp. 1759-1766
    • Duncan, B.W.1    Desai, S.2
  • 5
  • 6
    • 0032709340 scopus 로고    scopus 로고
    • Redirection of hepatic venous drainage after total cavopulmonaryshunt in left isomerism
    • Uemura, H., Yagihara, T., Hattori, R., Kawahira, Y., Tsukano, S., and Watanabe,K., 1999, "Redirection of Hepatic Venous Drainage After Total CavopulmonaryShunt in Left Isomerism," Ann. Thorac. Surg., 68, pp. 1731-1735.
    • (1999) Ann. Thorac. Surg , vol.68 , pp. 1731-1735
    • Uemura, H.1    Yagihara, T.2    Hattori, R.3    Kawahira, Y.4    Tsukano, S.5    Watanabe, K.6
  • 7
    • 3242781894 scopus 로고    scopus 로고
    • Regression of severe pulmonary arteriovenous malformations after Fontan revision and "hepatic factor" rerouting
    • DOI 10.1016/j.athoracsur.2004.02.003, PII S0003497504002255
    • Pike, N. A., Vricella, L. A., Feinstein, J. A., Black, M. D., and Reitz, B. A.,2004, "Regression of Severe Pulmonary Arteriovenous Malformations AfterFontan Revision and Hepatic Factor Rerouting," Ann. Thorac. Surg., 78, pp.697-699. (Pubitemid 38980806)
    • (2004) Annals of Thoracic Surgery , vol.78 , Issue.2 , pp. 697-699
    • Pike, N.A.1    Vricella, L.A.2    Feinstein, J.A.3    Black, M.D.4    Reitz, B.A.5
  • 8
    • 79956105774 scopus 로고    scopus 로고
    • Cavopulmonary pathway modification in patients with heterotaxyand newly diagnosed or persistent pulmonary arteriovenous malformationsafter a modified fontan operation
    • McElhinney, D. B., Marx, G. R., Marshall, A. C., Mayer, J. E., and del Nido, P.J., 2011, "Cavopulmonary Pathway Modification in Patients With Heterotaxyand Newly Diagnosed or Persistent Pulmonary Arteriovenous MalformationsAfter a Modified Fontan Operation," J. Thorac. Cardiovasc. Surg., 141(6), pp.1362-1370.
    • (2011) J. Thorac. Cardiovasc. Surg , vol.141 , Issue.6 , pp. 1362-1370
    • McElhinney, D.B.1    Marx, G.R.2    Marshall, A.C.3    Mayer, J.E.4    Del Nido, P.J.5
  • 9
    • 33747095206 scopus 로고    scopus 로고
    • Redirection of the hepatic venous flow for the treatment of pulmonary arteriovenous malformations after Fontan operation
    • DOI 10.1007/s00246-006-1242-2
    • Imoto, Y., Sese, A., and Joh, K., 2006, "Redirection of the Hepatic VenousFlow for the Treatment of Pulmonary Arteriovenous Malformations After FontanOperation," Pediatr. Cardiol., 27, pp. 490-492. (Pubitemid 44222406)
    • (2006) Pediatric Cardiology , vol.27 , Issue.4 , pp. 490-492
    • Imoto, Y.1    Sese, A.2    Joh, K.3
  • 10
    • 0030068248 scopus 로고    scopus 로고
    • A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection
    • DOI 10.1016/0021-9290(95)00021-6
    • Dubini, G., de Leval, M. R., Pietrabissa, R., Montevecchi, F. M., and Fumero,R., 1996. "A Numerical Fluid Mechanical Study of Repaired Congenital HeartDefects: Application to the Total Cavopulmonary Connection," J. Biomech.,29(1), pp. 111-121. (Pubitemid 26009411)
    • (1996) Journal of Biomechanics , vol.29 , Issue.1 , pp. 111-121
    • Dubini, G.1    De Leval, M.R.2    Pietrabissa, R.3    Montevecchi, F.M.4    Fumero, R.5
  • 11
    • 0742306283 scopus 로고    scopus 로고
    • Computational Fluid Dynamics Simulations in Realistic 3-D Geometries of the Total Cavopulmonary Anastomosis: The Influence of the Inferior Caval Anastomosis
    • DOI 10.1115/1.1632523
    • Migliavacca, F., Dubini, G., Bove, E. L., and de Leval, M. R., 2003,"Computational Fluid Dynamics Simulations in Realistic 3-D Geometries ofthe Total Cavopulmonary Anastomosis: The Influence of the Inferior CavalAnastomosis," J. Biomech. Eng., 125, pp. 805-813. (Pubitemid 38160031)
    • (2003) Journal of Biomechanical Engineering , vol.125 , Issue.6 , pp. 805-813
    • Migliavacca, F.1    Dubini, G.2    Bove, E.L.3    De Leval, M.R.4
  • 12
    • 34748833584 scopus 로고    scopus 로고
    • Nonlinear power loss during exercise in single-ventricle patients after the fontan: Insights from computational fluiddynamics
    • Whitehead, K. K., Pekkan, K., Kitahima, H. D., Paridon, S. M., Yoganathan, A.P., and Fogel, M. A., 2007, "Nonlinear Power Loss During Exercise in Single-Ventricle Patients After the Fontan: Insights From Computational FluidDynamics," Circulation, 116, pp. I-165-I-171.
    • (2007) Circulation , vol.116
    • Whitehead, K.K.1    Pekkan, K.2    Kitahima, H.D.3    Paridon, S.M.4    Yoganathan, A.P.5    Fogel, M.A.6
  • 13
    • 33846307817 scopus 로고    scopus 로고
    • Effects of exercise and respiration on hemodynamic efficiency in CFD simulations of the total cavopulmonary connection
    • DOI 10.1007/s10439-006-9224-3
    • Marsden, A. L., Vignon-Clementel, I. E., Chan, F., Feinstein, J. A., and Taylor,C. A., 2007, "Effects of Exercise and Respiration on Hemodynamic Efficiencyin CFD Simulations of the Total Cavopulmonary Connection," Ann. Biomed.Eng., 35(2), pp. 250-263. (Pubitemid 46122180)
    • (2007) Annals of Biomedical Engineering , vol.35 , Issue.2 , pp. 250-263
    • Marsden, A.L.1    Vignon-Clementel, I.E.2    Chan, F.P.3    Feinstein, J.A.4    Taylor, C.A.5
  • 14
    • 0035660433 scopus 로고    scopus 로고
    • Distribution of hepatic venous blood in the total cavo pulmonary connection: An in vitro study into the effects of connection geometry
    • DOI 10.1115/1.1407827
    • Walker, P. G., Oweis, G. F., and Watterson, K. G., 2001, "Distribution of HepaticVenous Blood in the Total Cavo Pulmonary Connection: An In Vitro Study intothe Effects of Connection Geometry," J. Biomech. Eng., 123(6), pp. 558-564. (Pubitemid 34019208)
    • (2001) Journal of Biomechanical Engineering , vol.123 , Issue.6 , pp. 558-564
    • Walker, P.G.1    Oweis, G.F.2    Watterson, K.G.3
  • 15
    • 0142244799 scopus 로고    scopus 로고
    • Computational fluid dynamics in the evaluation of hemodynamic performance of cavopulmonary connections after the Norwood procedure for hypoplastic left heart syndrome
    • DOI 10.1016/S0022-5223(03)00698-6
    • Bove, E. L., de Leval, M. R., Migliavacca, F., Guadagni, G., and Dubini, G.,2003, "Computational Fluid Dynamics in the Evaluation of Hemodynamic Performanceof Cavopulmonary Connections After the Norwood Procedure forHypoplastic Left Heart Syndrome," J. Thorac. Cardiovasc. Surg., 126, pp.1040-1047. (Pubitemid 37305687)
    • (2003) Journal of Thoracic and Cardiovascular Surgery , vol.126 , Issue.4 , pp. 1040-1047
    • Bove, E.L.1    De Leval, M.R.2    Migliavacca, F.3    Guadagni, G.4    Dubini, G.5
  • 16
    • 44649107730 scopus 로고    scopus 로고
    • Characterization of coherent structuresin the cardiovascular system
    • Shadden, S. C., and Taylor, C. A., 2008, "Characterization of Coherent Structuresin the Cardiovascular System," Ann. Biomed. Eng., 36(7), pp. 1152-1162.
    • (2008) Ann. Biomed. Eng , vol.36 , Issue.7 , pp. 1152-1162
    • Shadden, S.C.1    Taylor, C.A.2
  • 19
    • 84859772737 scopus 로고    scopus 로고
    • Hepatic blood flow distribution and performancein traditional and y-graft fontan geometries: A case series computational fluiddynamics study
    • Yang, W., Vignon-Clementel, I. E., Troianowski, G., Reddy, V. M., Feinstein, J.A., and Marsden, A. L., 2012, "Hepatic Blood Flow Distribution and Performancein Traditional and Y-Graft Fontan Geometries: A Case Series Computational FluidDynamics Study," J. Thorac. Cardiovasc. Surg., 143, pp. 1086-1097.
    • (2012) J. Thorac. Cardiovasc. Surg , vol.143 , pp. 1086-1097
    • Yang, W.1    Vignon-Clementel, I.E.2    Troianowski, G.3    Reddy, V.M.4    Feinstein, J.A.5    Marsden, A.L.6
  • 21
    • 77953616515 scopus 로고    scopus 로고
    • Constrained optimizationof an idealized y-shaped baffle for the fontan surgery at rest and exercise
    • Yang, W., Feinstein, J. A., and Marsden, A. L., 2010, "Constrained Optimizationof an Idealized Y-Shaped Baffle for the Fontan Surgery at Rest and Exercise,"Comput. Methods Appl. Mech. Eng., 199(33-36), pp. 2135-2149.
    • (2010) Comput. Methods Appl. Mech. Eng , vol.199 , Issue.33-36 , pp. 2135-2149
    • Yang, W.1    Feinstein, J.A.2    Marsden, A.L.3
  • 22
    • 40249118214 scopus 로고    scopus 로고
    • A computationalframework for derivative-free optimization of cardiovascular geometries
    • Marsden, A. L., Feinstein, J. A., and Taylor, C. A., 2008, "A ComputationalFramework for Derivative-Free Optimization of Cardiovascular Geometries,"Comput. Methods Appl. Mech. Eng., 197(21-24), pp. 1890-1905.
    • (2008) Comput. Methods Appl. Mech. Eng , vol.197 , Issue.21-24 , pp. 1890-1905
    • Marsden, A.L.1    Feinstein, J.A.2    Taylor, C.A.3
  • 24
    • 0030958062 scopus 로고    scopus 로고
    • Lung perfusion patterns after bidirectional cavopulmonary anastomosis (hemi-Fontan procedure)
    • DOI 10.1007/s002469900146
    • Seliem, M. A., Murphy, J., Vetter, J., Heyman, S., and Norwood, W., 1997,"Lung Perfusion Patterns After Bidirectional Cavopulmonary Anastomosis(Hemi-Fontan Procedure)," Pediatr. Cardiol., 18, pp. 191-196. (Pubitemid 27203232)
    • (1997) Pediatric Cardiology , vol.18 , Issue.3 , pp. 191-196
    • Seliem, M.A.1    Murphy, J.2    Vetter, J.3    Heyman, S.4    Norwood, W.5
  • 25
    • 82955195078 scopus 로고    scopus 로고
    • Three-dimensional simulations in glenn patients: Clinically basedboundary conditions, hemodynamic results and sensitivity to input data
    • Troianowski, G., Taylor, C. A., Feinstein, J. A., and Vignon-Clementel, I.,2011, "Three-Dimensional Simulations in Glenn Patients: Clinically BasedBoundary Conditions, Hemodynamic Results and Sensitivity to Input Data," J.Biomech. Eng., 133(11).
    • (2011) J.Biomech. Eng , vol.133 , pp. 11
    • Troianowski, G.1    Taylor, C.A.2    Feinstein, J.A.3    Vignon-Clementel, I.4
  • 26
    • 84958175395 scopus 로고    scopus 로고
    • A software framework for creating patient specific geometric models from medical imaging data for simulation based medical planning of vascular surgery
    • Medical Image Computing and Computer-Assisted Intervention - MICCAI 2001
    • Wilson, N., Wang, K., Dutton, R., and Taylor, C. A., 2001, "A Software Frameworkfor Creating Patient Specific Geometric Models From Medical ImagingData for Simulation Based Medical Planning of Vascular Surgery," Lect. NotesComput. Sci., 2208, pp. 449-456. (Pubitemid 33352443)
    • (2001) Lecture Notes in Computer Science , Issue.2208 , pp. 449-456
    • Wilson, N.1    Wang, K.2    Dutton, R.W.3    Taylor, C.4
  • 28
    • 0035104904 scopus 로고    scopus 로고
    • In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging
    • DOI 10.1016/S0003-4975(00)02517-0, PII S0003497500025170
    • Sharma, S., Ensley, A. E., Hopkins, K., Chatzimavrodis, G. P., Healy, T. M.,Tam, V. K. H., Kanter, K. R., and Yoganathan, A. P., 2001, "In Vivo Flow Dynamicsof the Total Cavopulmonary Connection From Three-Dimensional MultisliceMagnetic Resonance Imaging," Ann. Thorac. Surg., 71(3), pp. 889-898. (Pubitemid 32210396)
    • (2001) Annals of Thoracic Surgery , vol.71 , Issue.3 , pp. 889-898
    • Sharma, S.1    Ensley, A.E.2    Hopkins, K.3    Chatzimavroudis, G.P.4    Healy, T.M.5    Tam, V.K.H.6    Kanter, K.R.7    Yoganathan, A.P.8
  • 32
    • 0041915627 scopus 로고    scopus 로고
    • Effects of exercise and respiration on blood flow in total cavopulmonary connection: A real-time magnetic resonance flow study
    • DOI 10.1161/01.CIR.0000087406.27922.6B
    • Hjortdal, V. E., Emmertsen, K., Stenbog, E., Frund, T., Rahbek Schmidt, M.,Kromann, O., Sorensen, K., and Pedersen, E. M., 2003, "Effects of Exerciseand Respiration on Blood Flow in Total Cavopulmonary Connection: A Real-Time Magnetic Resonance Flow Study," Circulation, 108(10), pp. 1227-1231. (Pubitemid 37099992)
    • (2003) Circulation , vol.108 , Issue.10 , pp. 1227-1231
    • Hjortdal, V.E.1    Emmertsen, K.2    Stenbog, E.3    Frund, T.4    Schmidt, M.R.5    Kromann, O.6    Sorensen, K.7    Pedersen, E.M.8
  • 33
    • 77955704226 scopus 로고    scopus 로고
    • Outflow boundary conditions for 3d simulations of non-periodicblood flow and pressure fields in deformable arteries
    • Vignon-Clementel, I. E., Figueroa, C. A., Jansen, K. E., and Taylor, C. A.,2010, "Outflow Boundary Conditions for 3D Simulations of Non-PeriodicBlood Flow and Pressure Fields in Deformable Arteries," Comput. MethodsBiomech. Biomed. Eng., 13(5), pp. 625-640.
    • (2010) Comput. MethodsBiomech. Biomed. Eng , vol.13 , Issue.5 , pp. 625-640
    • Vignon-Clementel, I.E.1    Figueroa, C.A.2    Jansen, K.E.3    Taylor, C.A.4
  • 35
    • 33750265086 scopus 로고    scopus 로고
    • Mesh adaptive direct search algorithmsfor constrained optimization
    • Audet, C., and Dennis, Jr., J. E., 2006, "Mesh Adaptive Direct Search Algorithmsfor Constrained Optimization," SIAM J. Optim., 17(1), pp. 2-11.
    • (2006) SIAM J. Optim , vol.17 , Issue.1 , pp. 2-11
    • Audet, C.1    Dennis Jr., J.E.2
  • 36
    • 0043032999 scopus 로고    scopus 로고
    • Analysis of generalized patternsearches
    • Audet, C., and Dennis, Jr., J. E., 2003, "Analysis of Generalized PatternSearches," SIAM J. Optim., 13(3), pp. 889-903.
    • (2003) SIAM J. Optim , vol.13 , Issue.3 , pp. 889-903
    • Audet, C.1    Dennis Jr., J.E.2
  • 37
    • 0031540855 scopus 로고    scopus 로고
    • On the convergence of pattern search algorithms
    • Torczon, V., 1997, "On the Convergence of Pattern Search Algorithms," SIAMJ. Optim., 7, pp. 1-25.
    • (1997) SIAMJ. Optim , vol.7 , pp. 1-25
    • Torczon, V.1
  • 38
    • 7244230335 scopus 로고    scopus 로고
    • Optimalaeroacoustic shape design using the surrogate management framework
    • Special Issue: Surrogate Optimization
    • Marsden, A. L., Wang, M., Dennis, Jr., J. E., and Moin, P., 2004, "OptimalAeroacoustic Shape Design Using the Surrogate Management Framework,"Optim. Eng., 5(2), pp. 235-262. Special Issue: Surrogate Optimization.
    • (2004) Optim. Eng , vol.5 , Issue.2 , pp. 235-262
    • Marsden, A.L.1    Wang, M.2    Dennis Jr., J.E.3    Moin, P.4
  • 39
    • 7244253635 scopus 로고    scopus 로고
    • A pattern search filter method fornonlinear programming without derivatives
    • Audet, C., and Dennis, Jr., J. E., 2004, "A Pattern Search Filter Method forNonlinear Programming Without Derivatives," SIAM J. Optim., 14(4), pp.980-1010.
    • (2004) SIAM J. Optim , vol.14 , Issue.4 , pp. 980-1010
    • Audet, C.1    Dennis Jr., J.E.2
  • 45
    • 77951532031 scopus 로고    scopus 로고
    • A method for stochastic constrainedoptimization using derivative-free surrogate pattern search andcollocation
    • Audet, S. S. C., and Marsden, A. L., 2010, "A Method for Stochastic ConstrainedOptimization Using Derivative-Free Surrogate Pattern Search andCollocation," J. Comput. Phys., 229(12), pp. 4664-4682.
    • (2010) J. Comput. Phys , vol.229 , Issue.12 , pp. 4664-4682
    • Audet, S.S.C.1    Marsden, A.L.2
  • 46
    • 0031818179 scopus 로고    scopus 로고
    • Mechanics of end-to-end artery-to-PTFE graft anastomoses
    • DOI 10.1007/s100169900161
    • Dobrin, P. B., Mirande, P., Kang, S., Dong, Q. S., and Mrkvicka, R., 1998,"Mechanics of End-to-End Artery-to-PTFE Graft Anastomoses," Ann. Vasc.Surg., 12(4), pp. 317-323. (Pubitemid 28317628)
    • (1998) Annals of Vascular Surgery , vol.12 , Issue.4 , pp. 317-323
    • Dobrin, P.B.1    Mirande, R.2    Kang, S.3    Dong, Q.S.4    Mrkvicka, R.5
  • 47
    • 70349659157 scopus 로고    scopus 로고
    • Computational fluid-structure interaction: Methods and application to atotal cavopulmonary connection
    • Bazilevs, Y., Hsu, M.-C., Besnon, D., Sankaran, S., and Marsden, A. L., 2008,"Computational Fluid-Structure Interaction: Methods and Application to aTotal Cavopulmonary Connection," Comput. Mech., 45(1), pp. 77-89.
    • (2008) Comput. Mech , vol.45 , Issue.1 , pp. 77-89
    • Bazilevs, Y.1    Hsu, M.-C.2    Besnon, D.3    Sankaran, S.4    Marsden, A.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.