메뉴 건너뛰기




Volumn 182, Issue 3-4, 2015, Pages 611-616

Chitosan-functionalized gold nanoparticles for colorimetric detection of mercury ions based on chelation-induced aggregation

Author keywords

Chitosan; Colorimetry; Gold nanoparticles; Mercury ion

Indexed keywords


EID: 84922076762     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-014-1365-8     Document Type: Article
Times cited : (51)

References (27)
  • 1
    • 0042823833 scopus 로고    scopus 로고
    • The chemical form of mercury in fish
    • COI: 1:CAS:528:DC%2BD3sXmvFejurs%3D
    • Harris HH, Pickering IJ, George GN (2003) The chemical form of mercury in fish. Science 301:1203
    • (2003) Science , vol.301 , pp. 1203
    • Harris, H.H.1    Pickering, I.J.2    George, G.N.3
  • 2
    • 0142213730 scopus 로고    scopus 로고
    • The toxicology of mercury–current exposures and clinical manifestations
    • COI: 1:CAS:528:DC%2BD3sXos1SmsbY%3D
    • Clarkson TW, Magos L, Myers GJ (2003) The toxicology of mercury–current exposures and clinical manifestations. N Engl J Med 349:1731–1737
    • (2003) N Engl J Med , vol.349 , pp. 1731-1737
    • Clarkson, T.W.1    Magos, L.2    Myers, G.J.3
  • 4
    • 0032117073 scopus 로고    scopus 로고
    • Simple direct method for the determination of total mercury levels in blood and urine and nitric acid digests of fish by inductively coupled plasma mass spectrometry
    • COI: 1:CAS:528:DyaK1cXktVGgurk%3D
    • Moreton JA, Delves HTJ (1998) Simple direct method for the determination of total mercury levels in blood and urine and nitric acid digests of fish by inductively coupled plasma mass spectrometry. Anal Atom Spectrom 13:659–665
    • (1998) Anal Atom Spectrom , vol.13 , pp. 659-665
    • Moreton, J.A.1    Delves, H.T.J.2
  • 5
    • 0031175670 scopus 로고    scopus 로고
    • Determination of mercury compounds in water samples by liquid chromatography inductively coupled plasma mass spectrometry with an in situ nebulizer/vapor generator
    • COI: 1:CAS:528:DyaK2sXkvVWhurg%3D
    • Wan CC, Chen CS, Jiang SJ (1997) Determination of mercury compounds in water samples by liquid chromatography inductively coupled plasma mass spectrometry with an in situ nebulizer/vapor generator. J Anal At Spectrom 12:683–687
    • (1997) J Anal At Spectrom , vol.12 , pp. 683-687
    • Wan, C.C.1    Chen, C.S.2    Jiang, S.J.3
  • 6
    • 43049138064 scopus 로고    scopus 로고
    • Determination of mercury in ash and soil samples by oxygen flask combustion method-cold vapor atomic fluorescence spectrometry (CVAFS)
    • COI: 1:CAS:528:DC%2BD1cXlsFCjs7Y%3D
    • Geng W, Nakajima T, Takanashi H, Ohki A (2008) Determination of mercury in ash and soil samples by oxygen flask combustion method-cold vapor atomic fluorescence spectrometry (CVAFS). J Hazard Mater 154:325–30
    • (2008) J Hazard Mater , vol.154 , pp. 325-330
    • Geng, W.1    Nakajima, T.2    Takanashi, H.3    Ohki, A.4
  • 7
    • 0344443375 scopus 로고    scopus 로고
    • Turn-on” fluorescent sensor for detection of mercuric ion in aqueous media
    • COI: 1:CAS:528:DC%2BD3sXosVOguro%3D
    • Nolan EM, Lippard SJA (2003) “Turn-on” fluorescent sensor for detection of mercuric ion in aqueous media. J Am Chem Soc 125:14270–14271
    • (2003) J Am Chem Soc , vol.125 , pp. 14270-14271
    • Nolan, E.M.1    Lippard, S.J.A.2
  • 8
    • 33644946681 scopus 로고    scopus 로고
    • Modulating the sensory response of a conjugated polymer by proteins: an agglutination assay for mercury ions in water
    • COI: 1:CAS:528:DC%2BD28XhtlSrtrk%3D
    • Kim IB, Bunz UHF (2006) Modulating the sensory response of a conjugated polymer by proteins: an agglutination assay for mercury ions in water. J Am Chem Soc 128:2818–2819
    • (2006) J Am Chem Soc , vol.128 , pp. 2818-2819
    • Kim, I.B.1    Bunz, U.H.F.2
  • 10
    • 35048868774 scopus 로고    scopus 로고
    • Rational design of “turn-on” allosteric DNAzyme catalytic beacons for aqueous mercury ions with ultrahigh sensitivity and selectivity
    • COI: 1:CAS:528:DC%2BD2sXhtF2rsrzM
    • Liu J, Lu Y (2007) Rational design of “turn-on” allosteric DNAzyme catalytic beacons for aqueous mercury ions with ultrahigh sensitivity and selectivity. Angew Chem Int Ed 46:7587–7590
    • (2007) Angew Chem Int Ed , vol.46 , pp. 7587-7590
    • Liu, J.1    Lu, Y.2
  • 12
    • 1442300807 scopus 로고    scopus 로고
    • Heterogeneous colorimetric sensor for mercuric salts
    • Palomares E, Vilar R, Durrant JR (2004) Heterogeneous colorimetric sensor for mercuric salts. Chem Commun 4:362–363
    • (2004) Chem Commun , vol.4 , pp. 362-363
    • Palomares, E.1    Vilar, R.2    Durrant, J.R.3
  • 14
    • 17944366258 scopus 로고    scopus 로고
    • Nanostructures in biodiagnostics
    • COI: 1:CAS:528:DC%2BD2MXisVymsLk%3D
    • Rosi NL, Mirkin CA (2005) Nanostructures in biodiagnostics. Chem Rev 105:1547–1562
    • (2005) Chem Rev , vol.105 , pp. 1547-1562
    • Rosi, N.L.1    Mirkin, C.A.2
  • 15
    • 54349097780 scopus 로고    scopus 로고
    • Design of gold nanoparticle-based colorimetric biosensing assays
    • COI: 1:CAS:528:DC%2BD1cXht12hsrzM
    • Zhao WA, Brook MA, Li YF (2008) Design of gold nanoparticle-based colorimetric biosensing assays. ChemBioChem 9:2363–2371
    • (2008) ChemBioChem , vol.9 , pp. 2363-2371
    • Zhao, W.A.1    Brook, M.A.2    Li, Y.F.3
  • 18
    • 36249021042 scopus 로고    scopus 로고
    • Polymer-induced synthesis of stable gold and silver nanoparticles and subsequent ligand exchange in water
    • COI: 1:CAS:528:DC%2BD2sXhtFalurzE
    • Sardar R, Rark JW, Shumaker-Parry JS (2007) Polymer-induced synthesis of stable gold and silver nanoparticles and subsequent ligand exchange in water. Langmuir 23:11883–11889
    • (2007) Langmuir , vol.23 , pp. 11883-11889
    • Sardar, R.1    Rark, J.W.2    Shumaker-Parry, J.S.3
  • 19
    • 24644523302 scopus 로고    scopus 로고
    • Aptamer-modified gold nanoparticles for colorimetric determination of platelet-derived growth factors and their receptors
    • COI: 1:CAS:528:DC%2BD2MXntVOksbw%3D
    • Huang CC, Li YF, Cao ZH, Tan WH, Chang HT (2005) Aptamer-modified gold nanoparticles for colorimetric determination of platelet-derived growth factors and their receptors. Anal Chem 77:5735–5741
    • (2005) Anal Chem , vol.77 , pp. 5735-5741
    • Huang, C.C.1    Li, Y.F.2    Cao, Z.H.3    Tan, W.H.4    Chang, H.T.5
  • 20
    • 34250156343 scopus 로고    scopus 로고
    • Determination of size and concentration of gold nanoparticles from UV–vis spectra
    • COI: 1:CAS:528:DC%2BD2sXksFCit7s%3D
    • Haiss W, Thanh NTK, Aveyard J, Fernig DG (2007) Determination of size and concentration of gold nanoparticles from UV–vis spectra. Anal Chem 79:4215–4221
    • (2007) Anal Chem , vol.79 , pp. 4215-4221
    • Haiss, W.1    Thanh, N.T.K.2    Aveyard, J.3    Fernig, D.G.4
  • 21
    • 77951635589 scopus 로고    scopus 로고
    • Visual detection of melamine in raw milk using gold nanoparticles as colorimetric probe
    • COI: 1:CAS:528:DC%2BC3cXlslCmsr4%3D
    • Li L, Li B, Cheng D, Mao L (2010) Visual detection of melamine in raw milk using gold nanoparticles as colorimetric probe. Food Chem 122:895–900
    • (2010) Food Chem , vol.122 , pp. 895-900
    • Li, L.1    Li, B.2    Cheng, D.3    Mao, L.4
  • 22
    • 84881635455 scopus 로고    scopus 로고
    • Colorimetric sensing strategy for mercury(II) and melamine utilizing cysteamine-modified gold nanoparticles
    • COI: 1:CAS:528:DC%2BC3sXht1CltbrL
    • Ma Y, Jiang L, Mei Y, Song R, Tian D, Huang H (2013) Colorimetric sensing strategy for mercury(II) and melamine utilizing cysteamine-modified gold nanoparticles. Analyst 138:5338–5343
    • (2013) Analyst , vol.138 , pp. 5338-5343
    • Ma, Y.1    Jiang, L.2    Mei, Y.3    Song, R.4    Tian, D.5    Huang, H.6
  • 23
    • 84876580322 scopus 로고    scopus 로고
    • A colorimetric logic gate based on free gold nanoparticles and the coordination strategy between melamine and mercury ions
    • COI: 1:CAS:528:DC%2BC3sXmt1Cjtro%3D
    • Du JJ, Yin SY, Jiang L, Ma B, Chen XD (2013) A colorimetric logic gate based on free gold nanoparticles and the coordination strategy between melamine and mercury ions. Chem Commun 49:4196–4198
    • (2013) Chem Commun , vol.49 , pp. 4196-4198
    • Du, J.J.1    Yin, S.Y.2    Jiang, L.3    Ma, B.4    Chen, X.D.5
  • 24
    • 84876709429 scopus 로고    scopus 로고
    • Aptamer functionalized gold nanoparticles based fluorescent probe for the detection of mercury (II) ion in aqueous solution
    • COI: 1:CAS:528:DC%2BC3sXot1CjsbY%3D
    • Tan DD, He Y, Xing XJ, Zhao Y, Tang HW, Pang DW (2013) Aptamer functionalized gold nanoparticles based fluorescent probe for the detection of mercury (II) ion in aqueous solution. Talanta 113:26–30
    • (2013) Talanta , vol.113 , pp. 26-30
    • Tan, D.D.1    He, Y.2    Xing, X.J.3    Zhao, Y.4    Tang, H.W.5    Pang, D.W.6
  • 25
    • 84872119658 scopus 로고    scopus 로고
    • Selective fluorescent sensor for mercury ions in aqueous media using a 1,4-dihydropyridine derivative
    • COI: 1:CAS:528:DC%2BC38XhvFWht7jF
    • Homraruen D, Sirijindalert T, Dubas L, Sukwattanasinitt M, Ajavakom A (2013) Selective fluorescent sensor for mercury ions in aqueous media using a 1,4-dihydropyridine derivative. Tetrahedron 69:1617–1621
    • (2013) Tetrahedron , vol.69 , pp. 1617-1621
    • Homraruen, D.1    Sirijindalert, T.2    Dubas, L.3    Sukwattanasinitt, M.4    Ajavakom, A.5
  • 26
    • 84879699787 scopus 로고    scopus 로고
    • A FRET ratiometric fluorescence sensing system for mercury detection and intracellular colorimetric imaging in live Hela cells
    • COI: 1:CAS:528:DC%2BC3sXhtFCku77N
    • Hu B, Hu LL, Chen ML, Wang JH (2013) A FRET ratiometric fluorescence sensing system for mercury detection and intracellular colorimetric imaging in live Hela cells. Biosens Bioelectron 49:499–505
    • (2013) Biosens Bioelectron , vol.49 , pp. 499-505
    • Hu, B.1    Hu, L.L.2    Chen, M.L.3    Wang, J.H.4
  • 27
    • 84879866619 scopus 로고    scopus 로고
    • Highly sensitive, selective and reusable mercury(II) ion sensor based on a ssDNA-functionalized photonic crystal film
    • COI: 1:CAS:528:DC%2BC3sXhtVartLnI
    • Zhang YQ, Gao LJ, Wen LP, Heng LP, Song YL (2013) Highly sensitive, selective and reusable mercury(II) ion sensor based on a ssDNA-functionalized photonic crystal film. Phys Chem Chem Phys 15:11943–11949
    • (2013) Phys Chem Chem Phys , vol.15 , pp. 11943-11949
    • Zhang, Y.Q.1    Gao, L.J.2    Wen, L.P.3    Heng, L.P.4    Song, Y.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.