메뉴 건너뛰기




Volumn 120, Issue 2, 2015, Pages 355-361

Macroscopic barotrauma caused by stiff and soft-tipped airway exchange catheters: An in vitro case series

Author keywords

[No Author keywords available]

Indexed keywords

OXYGEN;

EID: 84922018556     PISSN: 00032999     EISSN: 15267598     Source Type: Journal    
DOI: 10.1213/ANE.0000000000000569     Document Type: Article
Times cited : (15)

References (22)
  • 1
    • 84856896588 scopus 로고    scopus 로고
    • Difficult Airway Society Guidelines for the management of tracheal extubation
    • Difficult Airway Society Extubation Guidelines Group: Popat M, Mitchell V, Dravid R, Patel A, Swampillai, Higgs A. Difficult Airway Society Guidelines for the management of tracheal extubation. Anaesthesia 2012; 67: 318-40
    • (2012) Anaesthesia , vol.67 , pp. 318-340
    • Popat, M.1    Mitchell, V.2    Dravid, R.3    Patel, A.4    Swampillai, H.A.5
  • 4
    • 0025744073 scopus 로고
    • Lung laceration after tracheal extubation over a plastic tube changer
    • deLima LG, Bishop MJ. Lung laceration after tracheal extubation over a plastic tube changer. Anesth Analg 1991; 73: 350-1
    • (1991) Anesth Analg , vol.73 , pp. 350-351
    • Delima, L.G.1    Bishop, M.J.2
  • 5
    • 0024815952 scopus 로고
    • Endobronchial rupture from endotracheal reintubation with an endotracheal tube guide
    • Seitz PA, Gravenstein N. Endobronchial rupture from endotracheal reintubation with an endotracheal tube guide. J Clin Anesth 1989; 1: 214-7
    • (1989) J Clin Anesth , vol.1 , pp. 214-217
    • Seitz, P.A.1    Gravenstein, N.2
  • 6
    • 34648834532 scopus 로고    scopus 로고
    • Tracheal laceration after the use of an airway exchange catheter for double-lumen tube placement
    • Thomas V, Neustein SM. Tracheal laceration after the use of an airway exchange catheter for double-lumen tube placement. J Cardiothorac Vasc Anesth 2007; 21: 718-9
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 718-719
    • Thomas, V.1    Neustein, S.M.2
  • 7
    • 79959934412 scopus 로고    scopus 로고
    • Brief review: Supplementing oxygen through an airway exchange catheter: Efficacy, complications, and recommendations
    • Duggan LV, Law JA, Murphy MF. Brief review: supplementing oxygen through an airway exchange catheter: efficacy, complications, and recommendations. Can J Anesth 2011; 58: 560-8
    • (2011) Can J Anesth , vol.58 , pp. 560-568
    • Duggan, L.V.1    Law, J.A.2    Murphy, M.F.3
  • 8
    • 33646757827 scopus 로고    scopus 로고
    • Unforeseen esophageal misplacement of airway exchange catheter leading to gastric perforation
    • Fetterman D, Dubovoy A, Reay M. Unforeseen esophageal misplacement of airway exchange catheter leading to gastric perforation. Anesthesiology 2006; 104: 1111-2
    • (2006) Anesthesiology , vol.104 , pp. 1111-1112
    • Fetterman, D.1    Dubovoy, A.2    Reay, M.3
  • 9
    • 84889041637 scopus 로고    scopus 로고
    • Airway exchange failure and complications with the use of the cook airway exchange catheter® : A single center cohort study of 1177 patients
    • McLean S, Lanam CR, Benedict W, Kirkpatrick N, Kheterpal S, Ramachandran SK. Airway exchange failure and complications with the use of the Cook Airway Exchange Catheter® : A single center cohort study of 1177 patients. Anesth Analg 2013; 117: 1325-7
    • (2013) Anesth Analg , vol.117 , pp. 1325-1327
    • McLean, S.1    Lanam, C.R.2    Benedict, W.3    Kirkpatrick, N.4    Kheterpal, S.5    Ramachandran, S.K.6
  • 10
    • 0032868737 scopus 로고    scopus 로고
    • Airway exchange catheters: Simple concept, potentially great danger
    • Benumof JL. Airway exchange catheters: simple concept, potentially great danger. Anesthesiology 1999; 91: 342-4
    • (1999) Anesthesiology , vol.91 , pp. 342-344
    • Benumof, J.L.1
  • 11
    • 79954556594 scopus 로고    scopus 로고
    • Major complications of airway management in the uk: Results of the fourth national audit project of the royal college of anaesthetists and the difficult airway society: Part 2: Intensive care and emergency departments
    • Cook T, Woodall N, Harper J, Benger J; Fourth National Audit Project. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society: Part 2: intensive care and emergency departments. Br J Anaesth 2011; 106: 632-42
    • (2011) Br J Anaesth , vol.106 , pp. 632-642
    • Cook, T.1    Woodall, N.2    Harper, J.3    Benger, J.4
  • 12
    • 84922028266 scopus 로고    scopus 로고
    • Cook Airway Exchange Catheters with Rapi-Fit™ Adapters: Instructions for use. Bloomington, IN: Cook Medical
    • Cook Airway Exchange Catheters with Rapi-Fit™ Adapters: Instructions for use. Bloomington, IN: Cook Medical. Available at: https: //www. cookmedical. com/data/IFU-PDF/C-T-CAE- REV4. pdf.
  • 13
    • 0021804210 scopus 로고
    • Barotrauma and hypotension resulting from jet ventilation in critically ill patients
    • Egol A, Culpepper JA, Snyder JV. Barotrauma and hypotension resulting from jet ventilation in critically ill patients. Chest 1985; 88: 98-102
    • (1985) Chest , vol.88 , pp. 98-102
    • Egol, A.1    Culpepper, J.A.2    Snyder, J.V.3
  • 15
    • 0030041544 scopus 로고    scopus 로고
    • The use of an endotracheal ventilation catheter in the management of difficult extubations
    • Cooper RM. The use of an endotracheal ventilation catheter in the management of difficult extubations. Can J Anesth 1996; 43: 90-3
    • (1996) Can J Anesth , vol.43 , pp. 90-93
    • Cooper, R.M.1
  • 18
    • 0030975058 scopus 로고    scopus 로고
    • A prospective study of the safety of tracheal extubation using a pediatric airway exchange catheter for patients with a known difficult airway
    • Loudermilk EP, Hartmannsgruber M, Stoltzfus DP, Langevin PB. A prospective study of the safety of tracheal extubation using a pediatric airway exchange catheter for patients with a known difficult airway. Chest 1997; 111: 1660-5
    • (1997) Chest , vol.111 , pp. 1660-1665
    • Loudermilk, E.P.1    Hartmannsgruber, M.2    Stoltzfus, D.P.3    Langevin, P.B.4
  • 19
    • 27144448939 scopus 로고    scopus 로고
    • The routine use of pediatric airway exchange catheter after extubation of adult patients who have undergone maxillofacial or major neck surgery: A clinical observational study
    • Dosemeci L, Yilmaz M, Yegin A, Cengiz M, Ramazanoglu A. The routine use of pediatric airway exchange catheter after extubation of adult patients who have undergone maxillofacial or major neck surgery: A clinical observational study. Crit Care 2004; 8: R385-90
    • (2004) Crit Care , vol.8 , pp. R385-R390
    • Dosemeci, L.1    Yilmaz, M.2    Yegin, A.3    Cengiz, M.4    Ramazanoglu, A.5
  • 20
    • 70349895332 scopus 로고    scopus 로고
    • Utility of airway exchange catheters in pediatric patients with a known difficult airway
    • Wise-Faberowski L, Nargaozian C. Utility of airway exchange catheters in pediatric patients with a known difficult airway. Pediatr Crit Care Med 2009; 10: 558-61
    • (2009) Pediatr Crit Care Med , vol.10 , pp. 558-561
    • Wise-Faberowski, L.1    Nargaozian, C.2
  • 21
    • 0030974225 scopus 로고    scopus 로고
    • Airway exchange catheters for safe extubation: The clinical and scientific details that make the concept work
    • Benumof JL. Airway exchange catheters for safe extubation: the clinical and scientific details that make the concept work. Chest 1997; 111: 1483-6
    • (1997) Chest , vol.111 , pp. 1483-1486
    • Benumof, J.L.1
  • 22
    • 84894317437 scopus 로고    scopus 로고
    • The traffic light bougie: A study of a novel safety modification
    • Paul A, Gibson AA, Robinson OD, Koch J. The traffic light bougie: A study of a novel safety modification. Anaesthesia 2014; 69: 214-8
    • (2014) Anaesthesia , vol.69 , pp. 214-218
    • Paul, A.1    Gibson, A.A.2    Robinson, O.D.3    Koch, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.