메뉴 건너뛰기




Volumn 40, Issue 2, 2015, Pages 87-94

Monitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test

Author keywords

cumulative summation; freehand technique; posterior lumbar interbody fusion; robot assisted pedicle screw fixation

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CUMULATIVE SUMMATION TEST; DIAGNOSTIC TEST; FEMALE; HUMAN; LUMBAR SPINAL STENOSIS; LUMBAR SPINE; MALE; MINIMALLY INVASIVE SURGERY; MONITORING; OUTCOME ASSESSMENT; PEDICLE SCREW; PRIORITY JOURNAL; PROSPECTIVE STUDY; QUALITY CONTROL; RANDOMIZED CONTROLLED TRIAL; ROBOT ASSISTED PEDICLE SCREW FIXATION; ROBOTIC SURGICAL PROCEDURE; SPINE FUSION; DEVICES; LUMBAR VERTEBRA; MIDDLE AGED; PROCEDURES; ROBOTICS; SPINAL STENOSIS; TREATMENT OUTCOME; VERY ELDERLY;

EID: 84921384329     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0000000000000680     Document Type: Article
Times cited : (86)

References (33)
  • 1
    • 79952277212 scopus 로고    scopus 로고
    • Robotic technology in spine surgery: Current applications and future developments
    • Stuer C, Ringel F, Stoffel M, et al. Robotic technology in spine surgery: current applications and future developments. Acta Neurochir Suppl 2011; 109: 241-5.
    • (2011) Acta Neurochir Suppl , vol.109 , pp. 241-245
    • Stuer, C.1    Ringel, F.2    Stoffel, M.3
  • 2
    • 84883004888 scopus 로고    scopus 로고
    • Robotic-assisted pedicle screw placement: Lessons learned from the first 102 patients
    • Hu X, Ohnmeiss DD, Lieberman IH. Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients. Eur Spine J 2012; 22: 661-6.
    • (2012) Eur Spine J , vol.22 , pp. 661-666
    • Hu, X.1    Ohnmeiss, D.D.2    Lieberman, I.H.3
  • 3
    • 84864284348 scopus 로고    scopus 로고
    • Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system
    • Lieberman IH, Hardenbrook MA, Wang JC, et al. Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system. J Spinal Disord Tech 2012; 25: 241-8.
    • (2012) J Spinal Disord Tech , vol.25 , pp. 241-248
    • Lieberman, I.H.1    Hardenbrook, M.A.2    Wang, J.C.3
  • 4
    • 84901275108 scopus 로고    scopus 로고
    • What is the learning curve for robotic-assisted pedicle screw placement in spine surgery?
    • Hu X, Lieberman IH. What is the learning curve for robotic-assisted pedicle screw placement in spine surgery? Clin Orthop Relat Res 2013; 472: 1839-44.
    • (2013) Clin Orthop Relat Res , vol.472 , pp. 1839-1844
    • Hu, X.1    Lieberman, I.H.2
  • 5
    • 84872085582 scopus 로고    scopus 로고
    • Spinal robotics: Current applications and future perspectives
    • Roser F, Tatagiba M, Maier G. Spinal robotics: current applications and future perspectives. Neurosurgery 2013; 72 (suppl 1): 12-8.
    • (2013) Neurosurgery , vol.72 , pp. 12-18
    • Roser, F.1    Tatagiba, M.2    Maier, G.3
  • 6
    • 77950786659 scopus 로고    scopus 로고
    • CUSUM: A dynamic tool for monitoring competency in cataract surgery performance
    • Salowi MA, Choong YF, Goh PP, et al. CUSUM: a dynamic tool for monitoring competency in cataract surgery performance. Br J Ophthalmol 2010; 94: 445-9.
    • (2010) Br J Ophthalmol , vol.94 , pp. 445-449
    • Salowi, M.A.1    Choong, Y.F.2    Goh, P.P.3
  • 7
    • 0026578890 scopus 로고
    • Quality control: An application of the CUSUM
    • Williams SM, Parry BR, Schlup MM. Quality control: an application of the CUSUM. BMJ 1992; 304: 1359-61.
    • (1992) BMJ , vol.304 , pp. 1359-1361
    • Williams, S.M.1    Parry, B.R.2    Schlup, M.M.3
  • 8
    • 33644894448 scopus 로고    scopus 로고
    • Transplant center quality assessment using a continuously updatable, risk-adjusted technique (CUSUM)
    • Axelrod DA, Guidinger MK, Metzger RA, et al. Transplant center quality assessment using a continuously updatable, risk-adjusted technique (CUSUM). Am J Transplant 2006; 6: 313-23.
    • (2006) Am J Transplant , vol.6 , pp. 313-323
    • Axelrod, D.A.1    Guidinger, M.K.2    Metzger, R.A.3
  • 9
    • 33745650895 scopus 로고    scopus 로고
    • Continuous monitoring of the performance of hip prostheses
    • Hardoon SL, Lewsey JD, Gregg PJ, et al. Continuous monitoring of the performance of hip prostheses. J Bone Joint Surg Br 2006; 88: 716-20.
    • (2006) J Bone Joint Surg Br , vol.88 , pp. 716-720
    • Hardoon, S.L.1    Lewsey, J.D.2    Gregg, P.J.3
  • 10
    • 66249091235 scopus 로고    scopus 로고
    • Monitoring surgical performance: An application to total hip replacement
    • Biau DJ, Milet A, Thevenin F, et al. Monitoring surgical performance: an application to total hip replacement. J Eval Clin Pract 2009; 15: 420-4.
    • (2009) J Eval Clin Pract , vol.15 , pp. 420-424
    • Biau, D.J.1    Milet, A.2    Thevenin, F.3
  • 11
    • 80052797565 scopus 로고    scopus 로고
    • Monitoring the quality of total hip replacement in a tertiary care department using a cumulative summation statistical method (CUSUM)
    • Biau DJ, Meziane M, Bhumbra RS, et al. Monitoring the quality of total hip replacement in a tertiary care department using a cumulative summation statistical method (CUSUM). J Bone Joint Surg Br 2011; 93: 1183-8.
    • (2011) J Bone Joint Surg Br , vol.93 , pp. 1183-1188
    • Biau, D.J.1    Meziane, M.2    Bhumbra, R.S.3
  • 12
    • 84863776762 scopus 로고    scopus 로고
    • Monitoring the one-year postoperative infection rate after primary total hip replacement
    • Biau DJ, Leclerc P, Marmor S, et al. Monitoring the one-year postoperative infection rate after primary total hip replacement. Int Orthop 2012; 36: 1155-61.
    • (2012) Int Orthop , vol.36 , pp. 1155-1161
    • Biau, D.J.1    Leclerc, P.2    Marmor, S.3
  • 13
    • 84875801197 scopus 로고    scopus 로고
    • Using the CUSUM test to control the proportion of inadequate open biopsies of musculoskel-etal tumors
    • Biau DJ, Weiss KR, Bhumbra RS, et al. Using the CUSUM test to control the proportion of inadequate open biopsies of musculoskel-etal tumors. Clin Orthop Relat Res 2013; 471: 905-14.
    • (2013) Clin Orthop Relat Res , vol.471 , pp. 905-914
    • Biau, D.J.1    Weiss, K.R.2    Bhumbra, R.S.3
  • 14
    • 79954438742 scopus 로고    scopus 로고
    • Defining the learning curve in laparoscopic paraesophageal hernia repair: A CUSUM analysis
    • Okrainec A, Ferri LE, Feldman LS, et al. Defining the learning curve in laparoscopic paraesophageal hernia repair: a CUSUM analysis. Surg Endosc 2011; 25: 1083-7.
    • (2011) Surg Endosc , vol.25 , pp. 1083-1087
    • Okrainec, A.1    Ferri, L.E.2    Feldman, L.S.3
  • 15
    • 4043154277 scopus 로고    scopus 로고
    • Use of the CUSUM technique for evaluation of a CT-based navigation system for total knee replacement
    • Nizard RS, Porcher R, Ravaud P, et al. Use of the CUSUM technique for evaluation of a CT-based navigation system for total knee replacement. Clin Orthop Relat Res 2004; 425: 180-8.
    • (2004) Clin Orthop Relat Res , vol.425 , pp. 180-188
    • Nizard, R.S.1    Porcher, R.2    Ravaud, P.3
  • 16
    • 39549111874 scopus 로고    scopus 로고
    • Clinical practice. Lumbar spinal stenosis
    • Katz JN, Harris MB. Clinical practice. Lumbar spinal stenosis. N Engl J Med 2008; 358: 818-25.
    • (2008) N Engl J Med , vol.358 , pp. 818-825
    • Katz, J.N.1    Harris, M.B.2
  • 17
    • 43749121419 scopus 로고    scopus 로고
    • Degenerative lumbar spinal stenosis: An evidence-based clinical guideline for the diagnosis and treatment of degenerative lumbar spinal stenosis
    • Watters WC III, Baisden J, Gilbert TJ, et al. Degenerative lumbar spinal stenosis: an evidence-based clinical guideline for the diagnosis and treatment of degenerative lumbar spinal stenosis. Spine J 2008; 8: 305-10.
    • (2008) Spine J , vol.8 , pp. 305-310
    • Watters, W.C.1    Baisden, J.2    Gilbert, T.J.3
  • 18
    • 84859955993 scopus 로고    scopus 로고
    • Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: A prospective randomized comparison to conventional freehand screw implantation
    • Ringel F, Stuer C, Reinke A, et al. Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation. Spine (Phila Pa 1976) 2012; 37: E496-501.
    • (2012) Spine (Phila Pa 1976) , vol.37 , pp. E496-501
    • Ringel, F.1    Stuer, C.2    Reinke, A.3
  • 21
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976) 2007; 32: E111-20.
    • (2007) Spine (Phila Pa 1976) , vol.32 , pp. E111-E120
    • Kosmopoulos, V.1    Schizas, C.2
  • 22
    • 70349804873 scopus 로고    scopus 로고
    • The learning curve of pedicle screw placement: How many screws are enough?
    • Gonzalvo A, Fitt G, Liew S, et al. The learning curve of pedicle screw placement: how many screws are enough? Spine (Phila Pa 1976) 2009; 34: E761-5.
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. E761-E765
    • Gonzalvo, A.1    Fitt, G.2    Liew, S.3
  • 23
    • 78650923994 scopus 로고    scopus 로고
    • Accuracy of freehand pedicle screws in the thoracic and lumbar spine: Analysis of 6816 consecutive screws
    • discussion 8
    • Parker SL, McGirt MJ, Farber SH, et al. Accuracy of freehand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 2011; 68: 170-8; discussion 8.
    • (2011) Neurosurgery , vol.68 , pp. 170-178
    • Parker, S.L.1    McGirt, M.J.2    Farber, S.H.3
  • 24
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 2000; 9: 235-40.
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 25
    • 80052594088 scopus 로고    scopus 로고
    • Perioperative course and accuracy of screw positioning in conventional, open robotic-guided, and percutaneous robotic-guided, pedicle screw placement
    • Kantelhardt SR, Martinez R, Baerwinkel S, et al. Perioperative course and accuracy of screw positioning in conventional, open robotic-guided, and percutaneous robotic-guided, pedicle screw placement. Eur Spine J 2011; 20: 860-8.
    • (2011) Eur Spine J , vol.20 , pp. 860-868
    • Kantelhardt, S.R.1    Martinez, R.2    Baerwinkel, S.3
  • 26
    • 84880050461 scopus 로고    scopus 로고
    • Feasibility of intra-operative computed tomography navigation system for pedicle screw insertion of the thoracolumbar spine [published online ahead of print December 3, 2012]
    • Lee MH, Lin MH, Weng HH, et al. Feasibility of intra-operative computed tomography navigation system for pedicle screw insertion of the thoracolumbar spine [published online ahead of print December 3, 2012]. J Spinal Disord Tech 2012. doi:10.1097/BSD.0b013e31828054c8.
    • (2012) J Spinal Disord Tech
    • Lee, M.H.1    Lin, M.H.2    Weng, H.H.3
  • 27
    • 80052604137 scopus 로고    scopus 로고
    • Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: Comparison between freehand and O-arm based navigation techniques
    • Silbermann J, Riese F, Allam Y, et al. Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between freehand and O-arm based navigation techniques. Eur Spine J 2011; 20: 875-81.
    • (2011) Eur Spine J , vol.20 , pp. 875-881
    • Silbermann, J.1    Riese, F.2    Allam, Y.3
  • 28
    • 64749091332 scopus 로고    scopus 로고
    • Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: First experiences and accuracy of screw placement
    • Pechlivanis I, Kiriyanthan G, Engelhardt M, et al. Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement. Spine (Phila Pa 1976) 2009; 34: 392-8.
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. 392-398
    • Pechlivanis, I.1    Kiriyanthan, G.2    Engelhardt, M.3
  • 29
    • 0037294229 scopus 로고    scopus 로고
    • Risk-adjusted sequential probability ratio tests: Applications to Bristol, Shipman and adult cardiac surgery
    • Spiegelhalter D, Grigg O, Kinsman R, et al. Risk-adjusted sequential probability ratio tests: applications to Bristol, Shipman and adult cardiac surgery. Int J Qual Health Care 2003; 15: 7-13.
    • (2003) Int J Qual Health Care , vol.15 , pp. 7-13
    • Spiegelhalter, D.1    Grigg, O.2    Kinsman, R.3
  • 30
    • 79952313199 scopus 로고    scopus 로고
    • Use of the learning curve-cumulative summation test for quantitative and individualized assessment of competency of a surgical procedure in obstetrics and gynecology: Fetoscopic laser ablation as a model
    • Papanna R, Biau DJ, Mann LK, et al. Use of the learning curve-cumulative summation test for quantitative and individualized assessment of competency of a surgical procedure in obstetrics and gynecology: fetoscopic laser ablation as a model. Am J Obstet Gynecol 2011; 204: 218 e1-9.
    • (2011) Am J Obstet Gynecol , vol.204 , pp. 218e1-9
    • Papanna, R.1    Biau, D.J.2    Mann, L.K.3
  • 31
    • 47249164267 scopus 로고    scopus 로고
    • Quantitative and individualized assessment of the learning curve using LC-CUSUM
    • Biau DJ, Williams SM, Schlup MM, et al. Quantitative and individualized assessment of the learning curve using LC-CUSUM. Br J Surg 2008; 95: 925-9.
    • (2008) Br J Surg , vol.95 , pp. 925-929
    • Biau, D.J.1    Williams, S.M.2    Schlup, M.M.3
  • 32
    • 84864559463 scopus 로고    scopus 로고
    • Pedicle screw navigation: A systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion
    • Shin BJ, James AR, Njoku IU, et al. Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion. J Neurosurg Spine 2012; 17: 113-22.
    • (2012) J Neurosurg Spine , vol.17 , pp. 113-122
    • Shin, B.J.1    James, A.R.2    Njoku, I.U.3
  • 33
    • 84866063323 scopus 로고    scopus 로고
    • Economics of less invasive spinal surgery: An analysis of hospital cost differences between open and minimally invasive instrumented spinal fusion procedures during the perioperative period
    • Lucio JC, Vanconia RB, Deluzio KJ, et al. Economics of less invasive spinal surgery: an analysis of hospital cost differences between open and minimally invasive instrumented spinal fusion procedures during the perioperative period. Risk Manag Healthc Policy 2012; 5: 65-74.
    • (2012) Risk Manag Healthc Policy , vol.5 , pp. 65-74
    • Lucio, J.C.1    Vanconia, R.B.2    Deluzio, K.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.