메뉴 건너뛰기




Volumn 179, Issue , 2015, Pages 539-545

Predictors of paravalvular aortic regurgitation following self-expanding Medtronic CoreValve implantation: The role of annulus size, degree of calcification, and balloon size during pre-implantation valvuloplasty and implant depth

Author keywords

Aortic stenosis; Paravalvular aortic regurgitation; Transcatheter aortic valve intervention

Indexed keywords

CALCIUM; CONTRAST MEDIUM;

EID: 84920659198     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2014.10.117     Document Type: Article
Times cited : (31)

References (32)
  • 9
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    • M. Abdel-Wahab, R. Zahn, M. Horack, U. Gerckens, G. Schuler, H. Sievert, H. Eggebrecht, J. Senges, and G. Richardt Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry Heart 97 2011 899 906
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3    Gerckens, U.4    Schuler, G.5    Sievert, H.6    Eggebrecht, H.7    Senges, J.8    Richardt, G.9
  • 14
    • 76649123667 scopus 로고    scopus 로고
    • Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding corevalve prosthesis
    • D. John, L. Buellesfeld, S. Yuecel, R. Mueller, G. Latsios, H. Beucher, U. Gerckens, and E. Grube Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding corevalve prosthesis JACC Cardiovasc. Interv. 3 2010 233 243
    • (2010) JACC Cardiovasc. Interv. , vol.3 , pp. 233-243
    • John, D.1    Buellesfeld, L.2    Yuecel, S.3    Mueller, R.4    Latsios, G.5    Beucher, H.6    Gerckens, U.7    Grube, E.8
  • 16
    • 78751655791 scopus 로고    scopus 로고
    • Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the medtronic corevalve bioprosthesis
    • M.A. Sherif, M. Abdel-Wahab, B. Stocker, V. Geist, D. Richardt, R. Tolg, and G. Richardt Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the medtronic corevalve bioprosthesis J. Am. Coll. Cardiol. 56 2010 1623 1629
    • (2010) J. Am. Coll. Cardiol. , vol.56 , pp. 1623-1629
    • Sherif, M.A.1    Abdel-Wahab, M.2    Stocker, B.3    Geist, V.4    Richardt, D.5    Tolg, R.6    Richardt, G.7
  • 18
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence
    • D. Detaint, L. Lepage, D. Himbert, E. Brochet, D. Messika-Zeitoun, B. Iung, and A. Vahanian Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence JACC Cardiovasc. Interv. 2 2009 821 827
    • (2009) JACC Cardiovasc. Interv. , vol.2 , pp. 821-827
    • Detaint, D.1    Lepage, L.2    Himbert, D.3    Brochet, E.4    Messika-Zeitoun, D.5    Iung, B.6    Vahanian, A.7
  • 19
    • 84870743337 scopus 로고    scopus 로고
    • SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    • S. Achenbach, V. Delgado, J. Hausleiter, P. Schoenhagen, J.K. Min, and J.A. Leipsic SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) J. Cardiovasc. Comput. Tomogr. 6 2012 366 380
    • (2012) J. Cardiovasc. Comput. Tomogr. , vol.6 , pp. 366-380
    • Achenbach, S.1    Delgado, V.2    Hausleiter, J.3    Schoenhagen, P.4    Min, J.K.5    Leipsic, J.A.6
  • 22
    • 84861678628 scopus 로고    scopus 로고
    • Direct aortic transcatheter aortic valve implantation: A feasible approach for patients with severe peripheral vascular disease
    • E. Alegria-Barrero, P.H. Chan, C. Di Mario, and N.E. Moat Direct aortic transcatheter aortic valve implantation: a feasible approach for patients with severe peripheral vascular disease Cardiovasc. Revasc. Med. 13 201 2012 e205 e207
    • (2012) Cardiovasc. Revasc. Med. , vol.13 , Issue.201 , pp. e205-e207
    • Alegria-Barrero, E.1    Chan, P.H.2    Di Mario, C.3    Moat, N.E.4
  • 25
    • 49749212248 scopus 로고
    • Left retrograde cardioangiography in acquired cardiac disease: Technic, indications and interpretations in 700 cases
    • R.D. Sellers, M.J. Levy, K. Amplatz, and C.W. Lillehei Left retrograde cardioangiography in acquired cardiac disease: technic, indications and interpretations in 700 cases Am. J. Cardiol. 14 1964 437 447
    • (1964) Am. J. Cardiol. , vol.14 , pp. 437-447
    • Sellers, R.D.1    Levy, M.J.2    Amplatz, K.3    Lillehei, C.W.4
  • 26
    • 84862838372 scopus 로고    scopus 로고
    • Valvular leak after transcatheter aortic valve implantation: A clinician update on epidemiology, pathophysiology and clinical implications
    • G. Tarantini, V. Gasparetto, M. Napodano, C. Fraccaro, G. Gerosa, and G. Isabella Valvular leak after transcatheter aortic valve implantation: a clinician update on epidemiology, pathophysiology and clinical implications Am. J. Cardiovasc. Dis. 1 2011 312 320
    • (2011) Am. J. Cardiovasc. Dis. , vol.1 , pp. 312-320
    • Tarantini, G.1    Gasparetto, V.2    Napodano, M.3    Fraccaro, C.4    Gerosa, G.5    Isabella, G.6
  • 28
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 fr) corevalve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • N. Piazza, E. Grube, U. Gerckens, P. den Heijer, A. Linke, O. Luha, A. Ramondo, G. Ussia, P. Wenaweser, S. Windecker, J.C. Laborde, P. de Jaegere, and P.W. Serruys Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval EuroIntervention 4 2008 242 249
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.C.11    De Jaegere, P.12    Serruys, P.W.13
  • 30
    • 79958178970 scopus 로고    scopus 로고
    • Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation
    • R. Koos, A.H. Mahnken, G. Dohmen, K. Brehmer, R.W. Gunther, R. Autschbach, N. Marx, and R. Hoffmann Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation Int. J. Cardiol. 150 2011 142 145
    • (2011) Int. J. Cardiol. , vol.150 , pp. 142-145
    • Koos, R.1    Mahnken, A.H.2    Dohmen, G.3    Brehmer, K.4    Gunther, R.W.5    Autschbach, R.6    Marx, N.7    Hoffmann, R.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.