메뉴 건너뛰기




Volumn 106, Issue , 2015, Pages 404-413

Quantitative water content mapping at clinically relevant field strengths: A comparative study at 1.5 T and 3 T

Author keywords

Clinical field strength; Parametric mapping; Proton density; Quantitative imaging; Water content

Indexed keywords

ADULT; ARTICLE; BRAIN MAPPING; CEREBRAL WATER CONTENT; CEREBROSPINAL FLUID; CONTRAST TO NOISE RATIO; GRAY MATTER; HISTOGRAM; HUMAN; HUMAN EXPERIMENT; IN VIVO STUDY; INTERMETHOD COMPARISON; MAGNETIC FIELD; MAGNETIC FIELD STRENGTH; MALE; MEASUREMENT ACCURACY; MEASUREMENT PRECISION; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; RADIOFREQUENCY; WATER CONTENT; WHITE MATTER; WHOLE BODY SCINTISCANNING; BRAIN CHEMISTRY; COMPARATIVE STUDY; DIAGNOSTIC USE; IMAGE ENHANCEMENT; IMAGE PROCESSING; PROCEDURES; RADIOFREQUENCY RADIATION; SIGNAL NOISE RATIO; YOUNG ADULT;

EID: 84920150818     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2014.11.017     Document Type: Article
Times cited : (47)

References (36)
  • 1
    • 84911984826 scopus 로고    scopus 로고
    • Analysis of proton-density bias corrections based on T measurement for robust quantification of water content in the brain at 3Tesla
    • Abbas Z., Gras V., Mollenhoff K., Keil F., Oros-Peusquens A.M., Shah N.J. Analysis of proton-density bias corrections based on T measurement for robust quantification of water content in the brain at 3Tesla. Magn. Reson. Med. 2014, 72:1735-1745.
    • (2014) Magn. Reson. Med. , vol.72 , pp. 1735-1745
    • Abbas, Z.1    Gras, V.2    Mollenhoff, K.3    Keil, F.4    Oros-Peusquens, A.M.5    Shah, N.J.6
  • 2
    • 84920113240 scopus 로고    scopus 로고
    • Quantitative cerebral water content changes after CSF removal in idiopathic normal pressure hydrocephalus: a preliminary analysis using MRI at 3 T
    • Abbas Z., Reetz K., Costa A.S., Gras V., Mirzazade S., Schiefer J., Neuloh G., Schulz J.B., Shah N.J. Quantitative cerebral water content changes after CSF removal in idiopathic normal pressure hydrocephalus: a preliminary analysis using MRI at 3 T. proc.ISMRM 2014, 1896.
    • (2014) proc.ISMRM , pp. 1896
    • Abbas, Z.1    Reetz, K.2    Costa, A.S.3    Gras, V.4    Mirzazade, S.5    Schiefer, J.6    Neuloh, G.7    Schulz, J.B.8    Shah, N.J.9
  • 3
    • 9344257289 scopus 로고    scopus 로고
    • Towards a molecular understanding of water homeostasis in the brain
    • Agre P., Nielsen S., Ottersen O.P. Towards a molecular understanding of water homeostasis in the brain. Neuroscience 2004, 129:849-850.
    • (2004) Neuroscience , vol.129 , pp. 849-850
    • Agre, P.1    Nielsen, S.2    Ottersen, O.P.3
  • 4
    • 0344430036 scopus 로고    scopus 로고
    • The molecular basis of water transport in the brain
    • Amiry-Moghaddam M., Ottersen O.P. The molecular basis of water transport in the brain. Nat. Rev. Neurosci. 2003, 4:991-1001.
    • (2003) Nat. Rev. Neurosci. , vol.4 , pp. 991-1001
    • Amiry-Moghaddam, M.1    Ottersen, O.P.2
  • 5
    • 0030955159 scopus 로고    scopus 로고
    • In vivo estimation of water content in cerebral white matter of brain tumour patients and normal individuals: towards a quantitative brain oedema definition
    • (discussion 255-246)
    • Andersen C. In vivo estimation of water content in cerebral white matter of brain tumour patients and normal individuals: towards a quantitative brain oedema definition. Acta Neurochir. (Wien) 1997, 139:249-255. (discussion 255-246).
    • (1997) Acta Neurochir. (Wien) , vol.139 , pp. 249-255
    • Andersen, C.1
  • 7
    • 0025117756 scopus 로고
    • Evaluation of proton density by magnetic resonance imaging: phantom experiments and analysis of multiple component proton transverse relaxation
    • Brix G., Schad L.R., Lorenz W.J. Evaluation of proton density by magnetic resonance imaging: phantom experiments and analysis of multiple component proton transverse relaxation. Phys. Med. Biol. 1990, 35:53-66.
    • (1990) Phys. Med. Biol. , vol.35 , pp. 53-66
    • Brix, G.1    Schad, L.R.2    Lorenz, W.J.3
  • 10
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    • Deoni S.C., Rutt B.K., Peters T.M. Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn. Reson. Med. 2003, 49:515-526.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 515-526
    • Deoni, S.C.1    Rutt, B.K.2    Peters, T.M.3
  • 11
    • 0026013025 scopus 로고
    • In vivo brain water determination by T1 measurements: effect of total water content, hydration fraction, and field strength
    • Fatouros P.P., Marmarou A., Kraft K.A., Inao S., Schwarz F.P. In vivo brain water determination by T1 measurements: effect of total water content, hydration fraction, and field strength. Magn. Reson. Med. 1991, 17:402-413.
    • (1991) Magn. Reson. Med. , vol.17 , pp. 402-413
    • Fatouros, P.P.1    Marmarou, A.2    Kraft, K.A.3    Inao, S.4    Schwarz, F.P.5
  • 12
    • 0035157986 scopus 로고    scopus 로고
    • Interregional variation of longitudinal relaxation rates in human brain at 3.0T: relation to estimated iron and water contents
    • Gelman N., Ewing J.R., Gorell J.M., Spickler E.M., Solomon E.G. Interregional variation of longitudinal relaxation rates in human brain at 3.0T: relation to estimated iron and water contents. Magn. Reson. Med. 2001, 45:71-79.
    • (2001) Magn. Reson. Med. , vol.45 , pp. 71-79
    • Gelman, N.1    Ewing, J.R.2    Gorell, J.M.3    Spickler, E.M.4    Solomon, E.G.5
  • 14
    • 84878422412 scopus 로고    scopus 로고
    • Spoiled FLASH MRI with slice selective excitation: signal equation with a correction term
    • Gras V., Abbas Z., Shah N.J. Spoiled FLASH MRI with slice selective excitation: signal equation with a correction term. Concepts Magn. Reson. A 2013, 42:89-100.
    • (2013) Concepts Magn. Reson. A , vol.42 , pp. 89-100
    • Gras, V.1    Abbas, Z.2    Shah, N.J.3
  • 17
    • 0035384136 scopus 로고    scopus 로고
    • A global optimisation method for robust affine registration of brain images
    • Jenkinson M., Smith S. A global optimisation method for robust affine registration of brain images. Med. Image Anal. 2001, 5:143-156.
    • (2001) Med. Image Anal. , vol.5 , pp. 143-156
    • Jenkinson, M.1    Smith, S.2
  • 18
    • 84866161886 scopus 로고    scopus 로고
    • Investigation of the spatial correlation in human white matter and the influence of age using 3-dimensional variography applied to MP-RAGE data
    • Keil F., Oros-Peusquens A.M., Shah N.J. Investigation of the spatial correlation in human white matter and the influence of age using 3-dimensional variography applied to MP-RAGE data. NeuroImage 2012, 63:1374-1383.
    • (2012) NeuroImage , vol.63 , pp. 1374-1383
    • Keil, F.1    Oros-Peusquens, A.M.2    Shah, N.J.3
  • 19
    • 9344258586 scopus 로고    scopus 로고
    • Water homeostasis in the brain: basic concepts
    • Kimelberg H.K. Water homeostasis in the brain: basic concepts. Neuroscience 2004, 129:851-860.
    • (2004) Neuroscience , vol.129 , pp. 851-860
    • Kimelberg, H.K.1
  • 20
    • 1642413441 scopus 로고    scopus 로고
    • Water content and myelin water fraction in multiple sclerosis. A T2 relaxation study
    • Laule C., Vavasour I.M., Moore G.R., Oger J., Li D.K., Paty D.W., MacKay A.L. Water content and myelin water fraction in multiple sclerosis. A T2 relaxation study. J. Neurol. 2004, 251:284-293.
    • (2004) J. Neurol. , vol.251 , pp. 284-293
    • Laule, C.1    Vavasour, I.M.2    Moore, G.R.3    Oger, J.4    Li, D.K.5    Paty, D.W.6    MacKay, A.L.7
  • 23
    • 33745727899 scopus 로고    scopus 로고
    • Enhancing the precision of quantitative water content mapping by optimizing sequence parameters
    • Neeb H., Shah N.J. Enhancing the precision of quantitative water content mapping by optimizing sequence parameters. Magn. Reson. Med. 2006, 56:224-229.
    • (2006) Magn. Reson. Med. , vol.56 , pp. 224-229
    • Neeb, H.1    Shah, N.J.2
  • 25
    • 33744942355 scopus 로고    scopus 로고
    • A new method for fast quantitative mapping of absolute water content in vivo
    • Neeb H., Zilles K., Shah N.J. A new method for fast quantitative mapping of absolute water content in vivo. NeuroImage 2006, 31:1156-1168.
    • (2006) NeuroImage , vol.31 , pp. 1156-1168
    • Neeb, H.1    Zilles, K.2    Shah, N.J.3
  • 28
    • 0035036729 scopus 로고    scopus 로고
    • Accurate multislice gradient echo T1 measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity
    • Parker G.J.M., Barker G.J., Tofts P.S. Accurate multislice gradient echo T1 measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity. Magn. Reson. Med. 2001, 45:838-845.
    • (2001) Magn. Reson. Med. , vol.45 , pp. 838-845
    • Parker, G.J.M.1    Barker, G.J.2    Tofts, P.S.3
  • 32
    • 84862249195 scopus 로고    scopus 로고
    • Correction of systematic errors in quantitative proton density mapping
    • Volz S., Noth U., Deichmann R. Correction of systematic errors in quantitative proton density mapping. Magn. Reson. Med. 2012, 68:74-85.
    • (2012) Magn. Reson. Med. , vol.68 , pp. 74-85
    • Volz, S.1    Noth, U.2    Deichmann, R.3
  • 33
    • 84864375585 scopus 로고    scopus 로고
    • Quantitative proton density mapping: correcting the receiver sensitivity bias via pseudo proton densities
    • Volz S., Noth U., Jurcoane A., Ziemann U., Hattingen E., Deichmann R. Quantitative proton density mapping: correcting the receiver sensitivity bias via pseudo proton densities. NeuroImage 2012, 63:540-552.
    • (2012) NeuroImage , vol.63 , pp. 540-552
    • Volz, S.1    Noth, U.2    Jurcoane, A.3    Ziemann, U.4    Hattingen, E.5    Deichmann, R.6
  • 34
    • 33847701745 scopus 로고    scopus 로고
    • Novel method for rapid, simultaneous T1, T2*, and proton density quantification
    • Warntjes J., Dahlqvist O., Lundberg P. Novel method for rapid, simultaneous T1, T2*, and proton density quantification. Magn. Reson. Med. 2007, 57:528-537.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 528-537
    • Warntjes, J.1    Dahlqvist, O.2    Lundberg, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.