메뉴 건너뛰기




Volumn 28, Issue 12, 2014, Pages e281-e283

Distal interlocking screw placement in the femur: Free-hand versus electromagnetic assisted technique (sureshot)

Author keywords

Distal locking; Intramedullary nails; Trauma

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; DISTAL INTERLOCKING SCREW; DRILL BIT; ELECTROMAGNETIC ASSISTED TECHNIQUE; ELECTROMAGNETIC RADIATION; FEMALE; FEMUR SHAFT FRACTURE; FLUOROSCOPY; FREE HAND TECHNIQUE; HUMAN; INTRAMEDULLARY NAIL; LOCKING SCREW; MAGNETIC AND ELECTROMAGNETIC EQUIPMENT; MAJOR CLINICAL STUDY; MALE; OPERATION DURATION; OUTCOME ASSESSMENT; PROSPECTIVE STUDY; RADIATION DOSE; RADIATION EXPOSURE; RANDOMIZED CONTROLLED TRIAL; SURGICAL TECHNIQUE; BONE SCREW; COMPUTER ASSISTED SURGERY; DEVICES; ELECTROMAGNETIC FIELD; FEMORAL FRACTURES; FEMUR; INTRAMEDULLARY NAILING; MIDDLE AGED; PROCEDURES; VERY ELDERLY; YOUNG ADULT;

EID: 84917676996     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0000000000000125     Document Type: Article
Times cited : (17)

References (16)
  • 1
    • 0024239204 scopus 로고
    • Intramedullary nailing of femoral shaft fractures. Part I: Decision-making errors with interlocking fixation
    • Brumback RJ, Reilly JP, Poka A, et al. Intramedullary nailing of femoral shaft fractures. Part I: decision-making errors with interlocking fixation. J Bone Joint Surg Am. 1988;70:1441-14 52.
    • (1988) J Bone Joint Surg Am. , vol.70 , pp. 1441-1452
    • Brumback, R.J.1    Reilly, J.P.2    Poka, A.3
  • 2
    • 0021885423 scopus 로고
    • Closed locked intramedullary nailing. Its application to comminuted fractures of the femur
    • Kempf I, Grosse A, Beck G. Closed locked intramedullary nailing. Its application to comminuted fractures of the femur. J Bone Joint Surg Am. 1985;67:709-720.
    • (1985) J Bone Joint Surg Am. , vol.67 , pp. 709-720
    • Kempf, I.1    Grosse, A.2    Beck, G.3
  • 3
    • 0024211938 scopus 로고
    • Intramedullary nailing of femoral shaft fractures. Part II: Fracture-healing with static interlocking fixation
    • Brumback RJ, Uwagie-Ero S, Lakatos A, et al. Intramedullary nailing of femoral shaft fractures. Part II: fracture-healing with static interlocking fixation. J Bone Joint Surg Am. 1988;70:1453-1462.
    • (1988) J Bone Joint Surg Am. , vol.70 , pp. 1453-1462
    • Brumback, R.J.1    Uwagie-Ero, S.2    Lakatos, A.3
  • 4
    • 31344455712 scopus 로고    scopus 로고
    • Literature review of current techniques for the insertion of distal screws into intramedullary locking nails
    • Wh atling GM, Nokes LDM. Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury. 2006;37:109-119.
    • (2006) Injury. , vol.37 , pp. 109-119
    • Whatling, G.M.1    Nokes, L.D.M.2
  • 5
    • 2342574698 scopus 로고    scopus 로고
    • Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study
    • Suhm N, Messmer P, Zuna I, et a l. Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study. Injury. 2004;35:567-574.
    • (2004) Injury. , vol.35 , pp. 567-574
    • Suhm, N.1    Messmer, P.2    Zuna, I.3
  • 6
    • 2642701689 scopus 로고    scopus 로고
    • A new mechanical aiming device for the placement of distal interlocking screws in femoral nails
    • Krettek C, Kö nemann B, Miclau T, et al. A new mechanical aiming device for the placement of distal interlocking screws in femoral nails. Arch Orthop Trauma Surg. 1998;117:147-152.
    • (1998) Arch Orthop Trauma Surg. , vol.117 , pp. 147-152
    • Krettek, C.1    Könemann, B.2    Miclau, T.3
  • 8
  • 9
    • 0022977181 scopus 로고
    • Insertion of the distal screws in interlocking nail fixation of femoral shaft fractures. Technical note
    • Medoff RJ. Insertion of the distal screws in interlocking nail fixation of femoral shaft fractures. Technical note. J Bone Joint Surg Am. 1986;68: 1275-1277.
    • (1986) J Bone Joint Surg Am. , vol.68 , pp. 1275-1277
    • Medoff, R.J.1
  • 10
    • 39149129995 scopus 로고    scopus 로고
    • Fracture and dislocation classification compendium-2007: Orthopaedic Trauma Association classification, database and outcomes committee
    • Marsh JL, Slongo TF, Agel J, et al. Fracture and dislocation classification compendium-2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma. 2007;21(suppl 10):S1-S133.
    • (2007) J Orthop Trauma. , vol.21 , pp. S1-S133
    • Marsh, J.L.1    Slongo, T.F.2    Agel, J.3
  • 12
    • 84877752797 scopus 로고    scopus 로고
    • The comparison of freehand fluoroscopic guidance and electromagnetic navigation for distal locking of intramedullary implants
    • Uruc V,Ozden R,Dogramac? Y,et al. epub ahead of print
    • Uruc V, Ozden R, Dogramac? Y, et al. The comparison of freehand fluoroscopic guidance and electromagnetic navigation for distal locking of intramedullary implants. Injury. 2013 [epub ahead of print].
    • (2013) Injury.
  • 13
    • 84880174333 scopus 로고    scopus 로고
    • Distal locking using an electromagnetic field guided computer based real time system for orthopaedic trauma patients
    • epub ahead of print
    • Langfitt MK, Halvorson JJ, Scott AT, et al. Distal locking using an electromagnetic field guided computer based real time system for orthopaedic trauma patients. J Orthop Trauma. 2013 [epub ahead of print].
    • (2013) J Orthop Trauma.
    • Langfitt, M.K.1    Halvorson, J.J.2    Scott, A.T.3
  • 14
    • 84877744113 scopus 로고    scopus 로고
    • Radiation-free distal locking of intramedullary nails: Evaluation of a new electromagnetic computer-assisted guidance system
    • Stathopoulos I, Karampinas P, Evangelopoulos DS, et al. Radiation-free distal locking of intramedullary nails: evaluation of a new electromagnetic computer-assisted guidance system. Injury. 2013;44:872-875.
    • (2013) Injury. , vol.44 , pp. 872-875
    • Stathopoulos, I.1    Karampinas, P.2    Evangelopoulos, D.S.3
  • 15
    • 85028175183 scopus 로고    scopus 로고
    • Insertion of distal locking screws of tibial intramedullary nails: A comparison between the free-hand technique and the SURESHOT™ Distal Targeting System
    • epub ahead of print
    • Moreschini O, Petrucci V, Cannata R. Insertion of distal locking screws of tibial intramedullary nails: a comparison between the free-hand technique and the SURESHOT™ Distal Targeting System. Injury. 2013;20: 432-434 [epub ahead of print].
    • (2013) Injury. , vol.20 , pp. 432-434
    • Moreschini, O.1    Petrucci, V.2    Cannata, R.3
  • 16
    • 18744389169 scopus 로고    scopus 로고
    • Occupational radiation exposure to the surgeon
    • Singer G. Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg. 2005;13:69-76.
    • (2005) J Am Acad Orthop Surg. , vol.13 , pp. 69-76
    • Singer, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.