메뉴 건너뛰기




Volumn 44, Issue 6, 2013, Pages 863-866

The comparison of freehand fluoroscopic guidance and electromagnetic navigation for distal locking of intramedullary implants

Author keywords

Electromagnetic guidance; Fluoroscopy; Intramedullary nailing

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BONE IMPLANT; COMPARATIVE STUDY; ELECTROMAGNETIC FIELD; FEMALE; FEMUR FRACTURE; FLUOROSCOPY; HUMAN; INTERLOCKING NAIL; INTRAMEDULLARY NAILING; MAJOR CLINICAL STUDY; MALE; OPERATION DURATION; OUTCOME ASSESSMENT; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIATION EXPOSURE; TIBIA FRACTURE;

EID: 84877752797     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2012.12.009     Document Type: Article
Times cited : (28)

References (30)
  • 1
    • 0024430479 scopus 로고
    • Results of the treatment of femoral and tibial fractures following interlocking nailing and plate osteosynthesis. A comparative retrospective study
    • G. Asche Results of the treatment of femoral and tibial fractures following interlocking nailing and plate osteosynthesis. A comparative retrospective study Zentralbl Chir 114 17 1989 1146 1154
    • (1989) Zentralbl Chir , vol.114 , Issue.17 , pp. 1146-1154
    • Asche, G.1
  • 2
    • 78649524064 scopus 로고    scopus 로고
    • Hands-on robotic distal interlocking in intramedullary nail fixation of femoral shaft fractures
    • M. Oszwald, R. Westphal, R. Stier, R. Gaulke, A. Calafi, and C.W. Muller Hands-on robotic distal interlocking in intramedullary nail fixation of femoral shaft fractures Technol Health Care 18 4-5 2010 325 334
    • (2010) Technol Health Care , vol.18 , Issue.45 , pp. 325-334
    • Oszwald, M.1    Westphal, R.2    Stier, R.3    Gaulke, R.4    Calafi, A.5    Muller, C.W.6
  • 4
    • 0028228049 scopus 로고
    • A simple jig to ease the insertion of distal screws in intramedullary locking nails
    • AUGUST 6
    • A. Hashemi-Nejad, N. Garlick, and N.J. Goddard A simple jig to ease the insertion of distal screws in intramedullary locking nails Injury 25 August (6) 1994 407 408
    • (1994) Injury , vol.25 , pp. 407-408
    • Hashemi-Nejad, A.1    Garlick, N.2    Goddard, N.J.3
  • 5
    • 0029315373 scopus 로고
    • A simple technique for insertion of distal screws into interlocking nails
    • JUNE 3
    • S.S. Kelley, S. Bonar, O.D. Hussamy, and J.A. Morrison A simple technique for insertion of distal screws into interlocking nails J Orthop Trauma 9 June (3) 1995 227 230
    • (1995) J Orthop Trauma , vol.9 , pp. 227-230
    • Kelley, S.S.1    Bonar, S.2    Hussamy, O.D.3    Morrison, J.A.4
  • 6
    • 1842842835 scopus 로고    scopus 로고
    • Tibial intramedullary nail distal interlocking screw placement: Comparison of the free-hand versus distally-based targeting device techniques
    • DECEMBER
    • Z. Gugala, A. Nana, and R.W. Lindsey Tibial intramedullary nail distal interlocking screw placement: comparison of the free-hand versus distally-based targeting device techniques Injury 32 December Suppl (4) 2001 SD21 SD25
    • (2001) Injury , vol.32 , Issue.SUPPL. 4
    • Gugala, Z.1    Nana, A.2    Lindsey, R.W.3
  • 8
    • 78751613693 scopus 로고    scopus 로고
    • External jig-aided intramedullary interlocking nailing of diaphyseal fractures: Experience from a tropical developing centre
    • JANUARY 1
    • I. Ikpeme, N. Ngim, A. Udosen, O. Onuba, O. Enembe, and S. Bello External jig-aided intramedullary interlocking nailing of diaphyseal fractures: experience from a tropical developing centre Int Orthop 35 January (1) 2011 107 111
    • (2011) Int Orthop , vol.35 , pp. 107-111
    • Ikpeme, I.1    Ngim, N.2    Udosen, A.3    Onuba, O.4    Enembe, O.5    Bello, S.6
  • 10
    • 0343035709 scopus 로고    scopus 로고
    • In vitro and in vivo radiomorphometric analyses of distal screw hole position of the solid tibial nail following insertion
    • APRIL 3
    • C. Krettek, B. Konemann, T. Miclau, P. Schlandelmaier, M. Blauth, and H. Tscherne In vitro and in vivo radiomorphometric analyses of distal screw hole position of the solid tibial nail following insertion Clin Biomech 12 April (3) 1997 198 200
    • (1997) Clin Biomech , vol.12 , pp. 198-200
    • Krettek, C.1    Konemann, B.2    Miclau, T.3    Schlandelmaier, P.4    Blauth, M.5    Tscherne, H.6
  • 12
    • 0035067424 scopus 로고    scopus 로고
    • Stress analysis of the distal locking screws for femoral interlocking nailing
    • JANUARY 1
    • J. Lin, S.J. Lin, P.Q. Chen, and S.H. Yang Stress analysis of the distal locking screws for femoral interlocking nailing J Orthop Res 19 January (1) 2001 57 63
    • (2001) J Orthop Res , vol.19 , pp. 57-63
    • Lin, J.1    Lin, S.J.2    Chen, P.Q.3    Yang, S.H.4
  • 13
    • 0031733555 scopus 로고    scopus 로고
    • Comparison of a radiation-independent aiming system and free-hand technique for distal locking of unslotted femoral nails
    • NOVEMBER 11
    • C. Krettek, B. Konemann, R. Kolbli, T. Machreich, A. Kromm, and H. Tscherne Comparison of a radiation-independent aiming system and free-hand technique for distal locking of unslotted femoral nails Unfallchirurg 101 November (11) 1998 822 829
    • (1998) Unfallchirurg , vol.101 , pp. 822-829
    • Krettek, C.1    Konemann, B.2    Kolbli, R.3    MacHreich, T.4    Kromm, A.5    Tscherne, H.6
  • 15
    • 0027263335 scopus 로고
    • Insertion of distal screws in interlocking intramedullary nails
    • MAY 5
    • H.H. Noordeen, M.J. Sala, and G.J. Belham Insertion of distal screws in interlocking intramedullary nails Injury 24 May (5) 1993 357 358
    • (1993) Injury , vol.24 , pp. 357-358
    • Noordeen, H.H.1    Sala, M.J.2    Belham, G.J.3
  • 16
    • 0029031829 scopus 로고
    • The treatment of closed, unstable tibial shaft fractures with unreamed interlocking nails
    • JUNE
    • P. Gregory, and R. Sanders The treatment of closed, unstable tibial shaft fractures with unreamed interlocking nails Clin Orthop Relat Res 315 June 1995 48 55
    • (1995) Clin Orthop Relat Res , vol.315 , pp. 48-55
    • Gregory, P.1    Sanders, R.2
  • 17
    • 0030033440 scopus 로고    scopus 로고
    • The rationales of interlocking nailing of the femur, tibia, and humerus
    • MARCH
    • R.J. Brumback The rationales of interlocking nailing of the femur, tibia, and humerus Clin Orthop Relat Res 324 March 1996 292 320
    • (1996) Clin Orthop Relat Res , vol.324 , pp. 292-320
    • Brumback, R.J.1
  • 18
    • 80052425133 scopus 로고    scopus 로고
    • Are there any advantages in using a distal aiming device for tibial nailing? Comparing the Centro Nailing System with the unreamed Tibia Nail
    • OCTOBER 10
    • E.J. Veen, H.B. Ettema, R.G. Zuurmond, and A.K. Mostert Are there any advantages in using a distal aiming device for tibial nailing? Comparing the Centro Nailing System with the unreamed Tibia Nail Injury 42 October (10) 2011 1049 1052
    • (2011) Injury , vol.42 , pp. 1049-1052
    • Veen, E.J.1    Ettema, H.B.2    Zuurmond, R.G.3    Mostert, A.K.4
  • 19
    • 0029932964 scopus 로고    scopus 로고
    • A comparison of one versus two distal locking screws in tibial fractures treated with unreamed tibial nails: A prospective randomized clinical trial
    • MAY 4
    • T. Kneifel, and R. Buckley A comparison of one versus two distal locking screws in tibial fractures treated with unreamed tibial nails: a prospective randomized clinical trial Injury 27 May (4) 1996 271 273
    • (1996) Injury , vol.27 , pp. 271-273
    • Kneifel, T.1    Buckley, R.2
  • 20
    • 0027207261 scopus 로고
    • The AO classification of long bone fractures: An early study of its use in clinical practice
    • MAY 5
    • M.L. Newey, D. Ricketts, and L. Roberts The AO classification of long bone fractures: an early study of its use in clinical practice Injury 24 May (5) 1993 309 312
    • (1993) Injury , vol.24 , pp. 309-312
    • Newey, M.L.1    Ricketts, D.2    Roberts, L.3
  • 22
    • 11244271466 scopus 로고    scopus 로고
    • Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: A clinical study
    • DECEMBER 10
    • T.R. Blattert, U.A. Fill, E. Kunz, W. Panzer, A. Weckbach, and D.F. Regulla Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study Arch Orthop Trauma Surg 124 December (10) 2004 659 664
    • (2004) Arch Orthop Trauma Surg , vol.124 , pp. 659-664
    • Blattert, T.R.1    Fill, U.A.2    Kunz, E.3    Panzer, W.4    Weckbach, A.5    Regulla, D.F.6
  • 23
    • 68549083585 scopus 로고    scopus 로고
    • Efficacy of an aiming device for the placement of distal interlocking screws in trochanteric fixation nailing
    • SEPTEMBER 9
    • S. Boraiah, J.U. Barker, and D. Lorich Efficacy of an aiming device for the placement of distal interlocking screws in trochanteric fixation nailing Arch Orthop Trauma Surg 129 September (9) 2009 1177 1182
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 1177-1182
    • Boraiah, S.1    Barker, J.U.2    Lorich, D.3
  • 24
    • 33847009436 scopus 로고    scopus 로고
    • Intramedullary nailing of the lower extremity: Biomechanics and biology
    • FEBRUARY 2
    • M.R. Bong, F.J. Kummer, K.J. Koval, and K.A. Egol Intramedullary nailing of the lower extremity: biomechanics and biology J Am Acad Orthop Surg 15 February (2) 2007 97 106
    • (2007) J Am Acad Orthop Surg , vol.15 , pp. 97-106
    • Bong, M.R.1    Kummer, F.J.2    Koval, K.J.3    Egol, K.A.4
  • 25
    • 56049122436 scopus 로고    scopus 로고
    • Evaluation of the Stryker S2 im Nail Distal Targeting Device for reduction of radiation exposure: A case series study
    • OCOTOBER 10
    • G. Anastopoulos, P.G. Ntagiopoulos, D. Chissas, G. Loupasis, A. Asimakopoulos, and E. Athanaselis Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study Injury 39 Ocotober (10) 2008 1210 1215
    • (2008) Injury , vol.39 , pp. 1210-1215
    • Anastopoulos, G.1    Ntagiopoulos, P.G.2    Chissas, D.3    Loupasis, G.4    Asimakopoulos, A.5    Athanaselis, E.6
  • 26
    • 2342574698 scopus 로고    scopus 로고
    • Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study
    • JUNE 6
    • N. Suhm, P. Messmer, I. Zuna, L.A. Jacob, and P. Regazzoni Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study Injury 35 June (6) 2004 567 574
    • (2004) Injury , vol.35 , pp. 567-574
    • Suhm, N.1    Messmer, P.2    Zuna, I.3    Jacob, L.A.4    Regazzoni, P.5
  • 28
    • 0025612507 scopus 로고
    • Shielding of the patient's gonads during intramedullary interlocking femoral nailing
    • DECEMBER 10
    • L.M. Kwong, P.H. Johanson, D.M. Zinar, M.R. Lenihan, and M.W. Herman Shielding of the patient's gonads during intramedullary interlocking femoral nailing J Bone Joint Surg Am 72 December (10) 1990 1523 1526
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 1523-1526
    • Kwong, L.M.1    Johanson, P.H.2    Zinar, D.M.3    Lenihan, M.R.4    Herman, M.W.5
  • 29
    • 0023278854 scopus 로고
    • Radiation exposure to the surgeon during closed interlocking intramedullary nailing
    • JUNE 5
    • P.E. Levin, R.W. Schoen Jr., and B.D. Browner Radiation exposure to the surgeon during closed interlocking intramedullary nailing J Bone Joint Surg Am 69 June (5) 1987 761 766
    • (1987) J Bone Joint Surg Am , vol.69 , pp. 761-766
    • Levin, P.E.1    Schoen, Jr.R.W.2    Browner, B.D.3
  • 30
    • 84864241682 scopus 로고    scopus 로고
    • Next generation distal locking for intramedullary nails using an electromagnetic X-ray-radiation-free real-time navigation system
    • JULY 1
    • M. Hoffmann, M. Schroder, W. Lehmann, M. Kammal, J.M. Rueger, and A. Herrman Ruecker Next generation distal locking for intramedullary nails using an electromagnetic X-ray-radiation-free real-time navigation system J Trauma Acute Care Surg 73 July (1) 2012 243 248
    • (2012) J Trauma Acute Care Surg , vol.73 , pp. 243-248
    • Hoffmann, M.1    Schroder, M.2    Lehmann, W.3    Kammal, M.4    Rueger, J.M.5    Herrman Ruecker, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.