메뉴 건너뛰기




Volumn 33, Issue 12, 2014, Pages 2271-2292

Artifact suppressed dictionary learning for low-dose CT image processing

Author keywords

Artifact suppressed dictionary learning algorithm (ASDL); artifact suppression; dictionary learning; low dose computed tomography (LDCT); noise

Indexed keywords

ABDOMINAL RADIOGRAPHY; AGED; ALGORITHM; ARTIFACT; ARTIFICIAL INTELLIGENCE; COMPUTER ASSISTED TOMOGRAPHY; DEVICES; FEMALE; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; MALE; MIDDLE AGED; PROCEDURES; RADIATION DOSE; THORAX RADIOGRAPHY; VERY ELDERLY;

EID: 84914151853     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/TMI.2014.2336860     Document Type: Article
Times cited : (296)

References (49)
  • 1
    • 0033864575 scopus 로고    scopus 로고
    • Radiation-related cancer risks at low doses among atomic bomb survivors
    • D. Pierce and D. Preston, "Radiation-related cancer risks at low doses among atomic bomb survivors," Radiat. Res., vol. 154, pp. 178-186, 2000.
    • (2000) Radiat. Res. , vol.154 , pp. 178-186
    • Pierce, D.1    Preston, D.2
  • 2
    • 1342266221 scopus 로고    scopus 로고
    • Strategies for CT radiation dose optimization1
    • M. Kalra et al., "Strategies for CT radiation dose optimization1," Radiology, vol. 230, pp. 619-628, 2004.
    • (2004) Radiology , vol.230 , pp. 619-628
    • Kalra, M.1
  • 3
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
    • J. Hsieh, "Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise," Med. Phys., vol. 25, pp. 2139-2147, 1998.
    • (1998) Med. Phys. , vol.25 , pp. 2139-2147
    • Hsieh, J.1
  • 4
    • 39749194408 scopus 로고    scopus 로고
    • Multiscale penalized weighted least-squares sinogram restoration for low-dose X-Ray computed tomography
    • Mar.
    • J. Wang, H. Lu, J. Wen, and Z. Liang, "Multiscale penalized weighted least-squares sinogram restoration for low-dose X-Ray computed tomography," IEEE Trans. Biomed. Eng., vol. 55, no. 3, pp. 1022-1031, Mar. 2008.
    • (2008) IEEE Trans. Biomed. Eng. , vol.55 , Issue.3 , pp. 1022-1031
    • Wang, J.1    Lu, H.2    Wen, J.3    Liang, Z.4
  • 5
    • 84856103240 scopus 로고    scopus 로고
    • Noise reduction to decrease radiation dose and improve conspicuity of hepatic lesions at contrast-enhanced 80-kV hepatic CT using projection space denoising
    • E. Ehman et al., "Noise reduction to decrease radiation dose and improve conspicuity of hepatic lesions at contrast-enhanced 80-kV hepatic CT using projection space denoising," Am. J. Roentgenol., vol. 198, pp. 405-411, 2012.
    • (2012) Am. J. Roentgenol. , vol.198 , pp. 405-411
    • Ehman, E.1
  • 6
    • 0032216626 scopus 로고    scopus 로고
    • Accelerated iterative transmission CT reconstruction using an ordered subset convex algorithm
    • Dec.
    • C. Kamphuis and F. Beekman, "Accelerated iterative transmission CT reconstruction using an ordered subset convex algorithm," IEEE Trans. Med. Imag., vol. 17, no. 6, pp. 1101-1105, Dec. 1998.
    • (1998) IEEE Trans. Med. Imag. , vol.17 , Issue.6 , pp. 1101-1105
    • Kamphuis, C.1    Beekman, F.2
  • 8
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • J. Thibault, K. Sauer, C. Bouman, and J. Hsieh, "A three-dimensional statistical approach to improved image quality for multislice helical CT," Med. Phys., vol. 34, pp. 4526-4544, 2007.
    • (2007) Med. Phys. , vol.34 , pp. 4526-4544
    • Thibault, J.1    Sauer, K.2    Bouman, C.3    Hsieh, J.4
  • 9
    • 51849124226 scopus 로고    scopus 로고
    • Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
    • E. Sidky andX. Pan, "Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization," Phys. Med. Biol., vol. 53, pp. 4777-4807, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4777-4807
    • Sidky, E.1    Pan, X.2
  • 10
    • 84914146457 scopus 로고    scopus 로고
    • Analysis of discrete-to-discrete imaging models for iterative tomographic image reconstruction and compressive sensing
    • Feb.
    • J. Jørgensen, E. Sidky, and X. Pan, "Analysis of discrete-to-discrete imaging models for iterative tomographic image reconstruction and compressive sensing," IEEE Trans. Med. Imag., vol. 32, no. 2, pp. 406-474, Feb. 2013.
    • (2013) IEEE Trans. Med. Imag. , vol.32 , Issue.2 , pp. 406-474
    • Jørgensen, J.1    Sidky, E.2    Pan, X.3
  • 12
    • 58149141914 scopus 로고    scopus 로고
    • Iterative image reconstruction for CBCT using edge-preserving prior
    • J.Wang, T. Li, and L. Xing, "Iterative image reconstruction for CBCT using edge-preserving prior," Med. Phys., vol. 36, pp. 252-260, 2009.
    • (2009) Med. Phys. , vol.36 , pp. 252-260
    • Wang, J.1    Li, T.2    Xing, L.3
  • 13
    • 38049054399 scopus 로고    scopus 로고
    • Nonlocal prior Bayesian tomographic reconstruction
    • Y. Chen, J. Ma, Q. Feng, L. Luo, W. Chen, and P. Shi, "Nonlocal prior Bayesian tomographic reconstruction," J. Math. Imag. Vis., vol. 30, pp. 133-146, 2008.
    • (2008) J. Math. Imag. Vis. , vol.30 , pp. 133-146
    • Chen, Y.1    Ma, J.2    Feng, Q.3    Luo, L.4    Chen, W.5    Shi, P.6
  • 14
    • 70350089978 scopus 로고    scopus 로고
    • Bayesian statistical reconstruction for low-dose X-ray computed tomography using an adaptive-weighting nonlocal prior
    • Y. Chen et al., "Bayesian statistical reconstruction for low-dose X-ray computed tomography using an adaptive-weighting nonlocal prior," Comput. Med. Imag. Graph, vol. 33, pp. 495-500, 2009.
    • (2009) Comput. Med. Imag. Graph , vol.33 , pp. 495-500
    • Chen, Y.1
  • 15
    • 70350645492 scopus 로고    scopus 로고
    • Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms
    • G.Chen, J. Tang, and B. Nett, "Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms," Phys. Med. Biol., vol. 54, pp. 5781-5804, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 5781-5804
    • Chen, G.1    Tang, J.2    Nett, B.3
  • 16
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    • G. Chen, J. Tang, and S. Leng, "Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets," Med. Phys., vol. 35, pp. 660-663, 2008.
    • (2008) Med. Phys. , vol.35 , pp. 660-663
    • Chen, G.1    Tang, J.2    Leng, S.3
  • 17
    • 84859757301 scopus 로고    scopus 로고
    • Time-resolved interventional cardiac C-arm cone-beam CT: An application of the PICCS algorithm
    • Apr.
    • G. Chen et al., "Time-resolved interventional cardiac C-arm cone-beam CT: An application of the PICCS algorithm," IEEE Trans. Med. Imag., vol. 31, no. 4, pp. 907-923, Apr. 2012.
    • (2012) IEEE Trans. Med. Imag. , vol.31 , Issue.4 , pp. 907-923
    • Chen, G.1
  • 18
    • 79959559491 scopus 로고    scopus 로고
    • Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm
    • M. Lubner, P. Pickhardt, J. Tang, and G. Chen, "Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm," Radiology, vol. 260, pp. 248-256, 2011.
    • (2011) Radiology , vol.260 , pp. 248-256
    • Lubner, M.1    Pickhardt, P.2    Tang, J.3    Chen, G.4
  • 19
    • 74749087439 scopus 로고    scopus 로고
    • Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
    • A. Silva, H. Lawder, A. Hara, J. Kujak, andW. Pavlicek, "Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm," Am. J. Roentgenol., vol. 194, pp. 191-199, 2010.
    • (2010) Am. J. Roentgenol. , vol.194 , pp. 191-199
    • Silva, A.1    Lawder, H.2    Hara, A.3    Kujak, J.4    Pavlicek, W.5
  • 20
    • 77958550185 scopus 로고    scopus 로고
    • Improvement of image quality of low radiation dose abdominal CT by increasing contrast enhancement
    • H. Watanabe et al., "Improvement of image quality of low radiation dose abdominal CT by increasing contrast enhancement," Am. J. Roentgenol., vol. 195, pp. 986-992, 2010.
    • (2010) Am. J. Roentgenol. , vol.195 , pp. 986-992
    • Watanabe, H.1
  • 21
    • 56849091499 scopus 로고    scopus 로고
    • Wavelet based noise reduction in CT-images using correlation analysis
    • A. Borsdorf, R. Raupach, T. Flohr, and J. Hornegger, "Wavelet based noise reduction in CT-images using correlation analysis," IEEE Trans. Med. Imag., vol. 27, pp. 1685-1703, 2008.
    • (2008) IEEE Trans. Med. Imag. , vol.27 , pp. 1685-1703
    • Borsdorf, A.1    Raupach, R.2    Flohr, T.3    Hornegger, J.4
  • 22
    • 80053642215 scopus 로고    scopus 로고
    • Improving low-dose abdominal CT images by weighted intensity averaging over large-scale neighborhoods
    • Y. Chen et al., "Improving low-dose abdominal CT images by weighted intensity averaging over large-scale neighborhoods," Eur. J. Radiol., vol. 80, pp. e42-e49, 2011.
    • (2011) Eur. J. Radiol. , vol.80 , pp. e42-e49
    • Chen, Y.1
  • 23
    • 84860153691 scopus 로고    scopus 로고
    • Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means
    • Y. Chen et al., "Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means," Phys. Med. Biol., vol. 57, pp. 2667-2688, 2012.
    • (2012) Phys. Med. Biol. , vol.57 , pp. 2667-2688
    • Chen, Y.1
  • 24
    • 0029938380 scopus 로고    scopus 로고
    • Emergence of simple-cell receptive field properties by learning a sparse code for natural images
    • M. Lewic, B. Olshausen, and D. Field, "Emergence of simple-cell receptive field properties by learning a sparse code for natural images," Nature, vol. 381, pp. 607-609, 1996.
    • (1996) Nature , vol.381 , pp. 607-609
    • Lewic, M.1    Olshausen, B.2    Field, D.3
  • 25
    • 0034133184 scopus 로고    scopus 로고
    • Learning overcomplete representations
    • M. Lewicki, "Learning overcomplete representations," Neural Comput., vol. 12, pp. 337-365, 2000.
    • (2000) Neural Comput. , vol.12 , pp. 337-365
    • Lewicki, M.1
  • 26
    • 0037313218 scopus 로고    scopus 로고
    • Dictionary learning algorithms for sparse representation
    • K. Delgado et al., "Dictionary learning algorithms for sparse representation," Neural Comput., vol. 15, pp. 349-396, 2003.
    • (2003) Neural Comput. , vol.15 , pp. 349-396
    • Delgado, K.1
  • 27
    • 0037418225 scopus 로고    scopus 로고
    • Maximal sparsity representation via l1 minimization
    • D. Donoho and M. Elad, "Maximal sparsity representation via l1 minimization," Proc. Nat. Aca. Sci., vol. 100, pp. 2197-2202, 2003.
    • (2003) Proc. Nat. Aca. Sci. , vol.100 , pp. 2197-2202
    • Donoho, D.1    Elad, M.2
  • 28
    • 33751379736 scopus 로고    scopus 로고
    • Image denoising via sparse and redundant representations over learned dictionaries
    • Dec.
    • M. Elad and M. Aharon, "Image denoising via sparse and redundant representations over learned dictionaries," IEEE Trans. Image Process., vol. 15, no. 12, pp. 3736-3745, Dec. 2006.
    • (2006) IEEE Trans. Image Process. , vol.15 , Issue.12 , pp. 3736-3745
    • Elad, M.1    Aharon, M.2
  • 29
    • 39149089704 scopus 로고    scopus 로고
    • Sparse representation for color image restoration
    • Jan.
    • J. Mairal, M. Elad, and G. Sapiro, "Sparse representation for color image restoration," IEEE Trans. Image Process., vol. 17, no. 1, pp. 53-69, Jan. 2008.
    • (2008) IEEE Trans. Image Process. , vol.17 , Issue.1 , pp. 53-69
    • Mairal, J.1    Elad, M.2    Sapiro, G.3
  • 30
    • 55149117992 scopus 로고    scopus 로고
    • Learning multiscale sparse representations for image and video restoration
    • J. Mairal, G. Sapiro, and M. Elad, "Learning multiscale sparse representations for image and video restoration," SIAM Multiscale Model. Simulat., vol. 7, pp. 214-241, 2008.
    • (2008) SIAM Multiscale Model. Simulat. , vol.7 , pp. 214-241
    • Mairal, J.1    Sapiro, G.2    Elad, M.3
  • 32
    • 79955633431 scopus 로고    scopus 로고
    • MR image reconstruction from highly undersampled k-space data by dictionary learning
    • May
    • S. Ravishankar and Y. Bresler, "MR image reconstruction from highly undersampled k-space data by dictionary learning," IEEE Trans. Med. Imag., vol. 30, no. 5, pp. 1028-1041, May 2011.
    • (2011) IEEE Trans. Med. Imag. , vol.30 , Issue.5 , pp. 1028-1041
    • Ravishankar, S.1    Bresler, Y.2
  • 33
    • 84880199209 scopus 로고    scopus 로고
    • A Dictionary learning approach for Poisson image deblurring
    • Jul.
    • L. Ma et al., "A Dictionary learning approach for Poisson image deblurring," IEEE Trans. Med. Imag., vol. 32, no. 7, pp. 1277-1289, Jul. 2013.
    • (2013) IEEE Trans. Med. Imag. , vol.32 , Issue.7 , pp. 1277-1289
    • Ma, L.1
  • 34
    • 67649892573 scopus 로고    scopus 로고
    • Compressed sensing based interior tomography
    • H. Yu and G.Wang, "Compressed sensing based interior tomography," Phys. Med. Biol., vol. 54, pp. 2791-805, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 2791-2805
    • Yu, H.1    Wang, G.2
  • 35
    • 84867561335 scopus 로고    scopus 로고
    • Lowdose x-ray CT reconstruction via dictionary learning
    • Sep.
    • Q. Xu, H. Y. Yu, X. Q. Mou, L. Zhang, J. Hsieh, and G. Wang, "Lowdose x-ray CT reconstruction via dictionary learning," IEEE Trans. Med. Imag., vol. 31, no. 9, pp. 1682-1697, Sep. 2012.
    • (2012) IEEE Trans. Med. Imag. , vol.31 , Issue.9 , pp. 1682-1697
    • Xu, Q.1    Yu, H.Y.2    Mou, X.Q.3    Zhang, L.4    Hsieh, J.5    Wang, G.6
  • 36
    • 84862960680 scopus 로고    scopus 로고
    • An efficient dictionary learning algorithmand its application to 3-Dmedical image denoising
    • Feb.
    • S. Li, L. Fang, and H. Yin, "An efficient dictionary learning algorithmand its application to 3-Dmedical image denoising," IEEE Trans. Biomed. Eng., vol. 59, no. 2, pp. 417-427, Feb. 2012.
    • (2012) IEEE Trans. Biomed. Eng. , vol.59 , Issue.2 , pp. 417-427
    • Li, S.1    Fang, L.2    Yin, H.3
  • 37
    • 83455236058 scopus 로고    scopus 로고
    • Few-view image reconstruction with dual dictionaries
    • Y. Lu, J. Zhao, and G. Wang, "Few-view image reconstruction with dual dictionaries," Phys. Med. Biol., vol. 57, pp. 173-189, 2012.
    • (2012) Phys. Med. Biol. , vol.57 , pp. 173-189
    • Lu, Y.1    Zhao, J.2    Wang, G.3
  • 38
    • 84871242060 scopus 로고    scopus 로고
    • Dual-dictionary learning-based iterative image reconstruction for spectral computed tomography application
    • B. Zhao et al., "Dual-dictionary learning-based iterative image reconstruction for spectral computed tomography application," Phys. Med. Biol., vol. 57, pp. 8217-8229, 2012.
    • (2012) Phys. Med. Biol. , vol.57 , pp. 8217-8229
    • Zhao, B.1
  • 39
    • 84881458652 scopus 로고    scopus 로고
    • Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing
    • Y. Chen et al., "Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing," Phys. Med. Biol., vol. 58, pp. 5803-5820, 2013.
    • (2013) Phys. Med. Biol. , vol.58 , pp. 5803-5820
    • Chen, Y.1
  • 41
    • 79953811027 scopus 로고    scopus 로고
    • Statistical sinogram smoothing for low-dose CT with segmentation-based adaptive filtering
    • Oct.
    • Y. K. Zhang, J. Y. Zhang, and H. B. Lu, "Statistical sinogram smoothing for low-dose CT with segmentation-based adaptive filtering," IEEE Trans. Nucl. Sci., vol. 57, no. 5, pp. 2587-2598, Oct. 2010.
    • (2010) IEEE Trans. Nucl. Sci. , vol.57 , Issue.5 , pp. 2587-2598
    • Zhang, Y.K.1    Zhang, J.Y.2    Lu, H.B.3
  • 42
    • 8344272167 scopus 로고    scopus 로고
    • Nonlinear sinogram smoothing for low-dose X-ray CT
    • Oct.
    • T. Li, X. Li, J.Wang, J. Wen, H. Lu, J.Hsieh, and Z. Liang, "Nonlinear sinogram smoothing for low-dose X-ray CT," IEEE Trans. Nucl. Sci, vol. 51, no. 5, pp. 2505-2513, Oct. 2004.
    • (2004) IEEE Trans. Nucl. Sci , vol.51 , Issue.5 , pp. 2505-2513
    • Li, T.1    Li, X.2    Wang, J.3    Wen, J.4    Lu, H.5    Hsieh, J.6    Liang, Z.7
  • 43
    • 1942436689 scopus 로고    scopus 로고
    • Image quality assessment: From error visibility to structural similarity
    • Apr.
    • Z. Wang, A. C. Bovik, H. R. Sheikh, and E. P. Simoncelli, "Image quality assessment: From error visibility to structural similarity," IEEE Trans. Image Process., vol. 13, no. 4, pp. 600-612, Apr. 2004.
    • (2004) IEEE Trans. Image Process. , vol.13 , Issue.4 , pp. 600-612
    • Wang, Z.1    Bovik, A.C.2    Sheikh, H.R.3    Simoncelli, E.P.4
  • 44
    • 67249099122 scopus 로고    scopus 로고
    • ViewDEX 2.0: A Java-based DICOM-compatible software for observer performance studies
    • M. Hakansson, S. Svensson, S. Zachrisson, A. Svalkvist, M. Bath, and L. G. Mansson, "ViewDEX 2.0: A Java-based DICOM-compatible software for observer performance studies," in Proc. SPIE, 2009, vol. 7263, pp. 72631G1-72631G10.
    • (2009) Proc. SPIE , vol.7263 , pp. 72631G1-72631G10
    • Hakansson, M.1    Svensson, S.2    Zachrisson, S.3    Svalkvist, A.4    Bath, M.5    Mansson, L.G.6
  • 45
    • 84874782588 scopus 로고    scopus 로고
    • A filtered backprojection algorithm with ray-by-ray noise weighting
    • G. Zeng and A. Zamyatin, "A filtered backprojection algorithm with ray-by-ray noise weighting," Med. Phys., vol. 40, p. 031113, 2013.
    • (2013) Med. Phys. , vol.40 , pp. 031113
    • Zeng, G.1    Zamyatin, A.2
  • 46
    • 84877359798 scopus 로고    scopus 로고
    • Iterative total-variation reconstruction versus weighted filtered-backprojection reconstruction with edgepreserving filtering
    • G. Zeng, Y. Li, and A. Zamyatin, "Iterative total-variation reconstruction versus weighted filtered-backprojection reconstruction with edgepreserving filtering," Phys. Med. Biol., vol. 58, pp. 3413-3431, 2013.
    • (2013) Phys. Med. Biol. , vol.58 , pp. 3413-3431
    • Zeng, G.1    Li, Y.2    Zamyatin, A.3
  • 47
    • 84901691549 scopus 로고    scopus 로고
    • Magnetic resonance image reconstruction from undersampled measurements using a patch-based nonlocal operator
    • X. Qu, Y. Hou, F. Lam, D. Guo, J. H. Zhong, and Z. Chen, "Magnetic resonance image reconstruction from undersampled measurements using a patch-based nonlocal operator," Med. Image Anal. [Online]. Available: http://dx.doi.org/10.1016/j.media.2013.09.007
    • Med. Image Anal
    • Qu, X.1    Hou, Y.2    Lam, F.3    Guo, D.4    Zhong, J.H.5    Chen, Z.6
  • 48
    • 78149479401 scopus 로고    scopus 로고
    • Segmenting CT prostate images using population and patient-specific statistics for radiotherapy
    • Q. Feng, M. Foskey, W. Chen, and D. Shen, "Segmenting CT prostate images using population and patient-specific statistics for radiotherapy," Med. Phys., vol. 37, pp. 4121-4132, 2010.
    • (2010) Med. Phys. , vol.37 , pp. 4121-4132
    • Feng, Q.1    Foskey, M.2    Chen, W.3    Shen, D.4
  • 49
    • 33847699693 scopus 로고    scopus 로고
    • Multiresolution elastic registration of X-Ray angiography images using thin-plate spline
    • Feb.
    • J.Yang, Y.Wang, S. Tang, S. Zhou,Y. Liu, andW. Chen, "Multiresolution elastic registration of X-Ray angiography images using thin-plate spline," IEEE Trans. Nucl. Sci., vol. 54, no. 1, pp. 152-166, Feb. 2007
    • (2007) IEEE Trans. Nucl. Sci. , vol.54 , Issue.1 , pp. 152-166
    • Yang, J.1    Wang, Y.2    Tang, S.3    Zhou, S.4    Liu, Y.5    Chen, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.