메뉴 건너뛰기




Volumn 24, Issue 12, 2014, Pages 3269-3276

Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study

Author keywords

Computed tomography; Digital tomosynthesis; Pulmonary nodule; Radiography; Thoracic imaging

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIGITAL IMAGING; DIGITAL TOMOSYNTHESIS; FREE RESPONSE RECEIVER OPERATING CHARACTERISTIC; GROUND GLASS OPACITY; IMAGE QUALITY; IMAGING PHANTOM; INTERMETHOD COMPARISON; LOW DOSE MULTIDETECTOR COMPUTED TOMOGRAPHY; LUNG NODULE; STATISTICAL ANALYSIS; THORAX RADIOGRAPHY; COMPARATIVE STUDY; HUMAN; MULTIDETECTOR COMPUTED TOMOGRAPHY; MULTIPLE PULMONARY NODULES; PROCEDURES; RADIOGRAPHY; RECEIVER OPERATING CHARACTERISTIC; REPRODUCIBILITY;

EID: 84911805659     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-014-3376-6     Document Type: Article
Times cited : (18)

References (27)
  • 1
    • 0032617845 scopus 로고    scopus 로고
    • Clinical utility of chest roentgenograms
    • COI: 1:STN:280:DyaK1M3otlehsg%3D%3D, PID: 10354893
    • Geitung JT, Skjaerstad LM, Gothlin JH (1999) Clinical utility of chest roentgenograms. Eur Radiol 9:721–723
    • (1999) Eur Radiol , vol.9 , pp. 721-723
    • Geitung, J.T.1    Skjaerstad, L.M.2    Gothlin, J.H.3
  • 2
    • 33747036920 scopus 로고    scopus 로고
    • Chest radiography in general practice: indications, diagnostic yield and consequences for patient management
    • PID: 16882374
    • Speets AM, van der Graaf Y, Hoes AW et al (2006) Chest radiography in general practice: indications, diagnostic yield and consequences for patient management. Br J Gen Pract 56:574–578
    • (2006) Br J Gen Pract , vol.56 , pp. 574-578
    • Speets, A.M.1    van der Graaf, Y.2    Hoes, A.W.3
  • 3
    • 0032748266 scopus 로고    scopus 로고
    • Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs
    • COI: 1:STN:280:DC%2BD3c%2Fls1Ohsg%3D%3D, PID: 10580946
    • Samei E, Flynn MJ, Eyler WR (1999) Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. Radiology 213:727–734
    • (1999) Radiology , vol.213 , pp. 727-734
    • Samei, E.1    Flynn, M.J.2    Eyler, W.R.3
  • 5
    • 77952481687 scopus 로고    scopus 로고
    • Dual energy CT of the chest: how about the dose?
    • Schenzle JC, Sommer WH, Neumaier K et al (2010) Dual energy CT of the chest: how about the dose? Investig Radiol 45:347–353
    • (2010) Investig Radiol , vol.45 , pp. 347-353
    • Schenzle, J.C.1    Sommer, W.H.2    Neumaier, K.3
  • 6
    • 78751615956 scopus 로고    scopus 로고
    • High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography
    • Lell MM, May M, Deak P et al (2011) High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Investig Radiol 46:116–123
    • (2011) Investig Radiol , vol.46 , pp. 116-123
    • Lell, M.M.1    May, M.2    Deak, P.3
  • 7
    • 84874935300 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M et al (2013) Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Investig Radiol 48:206–212
    • (2013) Investig Radiol , vol.48 , pp. 206-212
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 8
    • 0026228618 scopus 로고
    • Development of a high-resolution digital tomosynthesis system and its clinical application
    • COI: 1:STN:280:DyaK38%2FltlelsQ%3D%3D, PID: 1947318
    • Sone S, Kasuga T, Sakai F et al (1991) Development of a high-resolution digital tomosynthesis system and its clinical application. Radiographics 11:807–822
    • (1991) Radiographics , vol.11 , pp. 807-822
    • Sone, S.1    Kasuga, T.2    Sakai, F.3
  • 10
    • 44349192079 scopus 로고    scopus 로고
    • Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial
    • PID: 18649488
    • James TD, McAdams HP, Song JW et al (2008) Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial. Med Phys 35:2554–2557
    • (2008) Med Phys , vol.35 , pp. 2554-2557
    • James, T.D.1    McAdams, H.P.2    Song, J.W.3
  • 11
    • 58149198701 scopus 로고    scopus 로고
    • Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases
    • PID: 18849504
    • Vikgren J, Zachrisson S, Svalkvist A et al (2008) Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 249:1034–1041
    • (2008) Radiology , vol.249 , pp. 1034-1041
    • Vikgren, J.1    Zachrisson, S.2    Svalkvist, A.3
  • 12
    • 79959807399 scopus 로고    scopus 로고
    • Fast scanning tomosynthesis for the detection of pulmonary nodules: diagnostic performance compared with chest radiography, using multidetector-row computed tomography as the reference
    • Yamada Y, Jinzaki M, Hasegawa I et al (2011) Fast scanning tomosynthesis for the detection of pulmonary nodules: diagnostic performance compared with chest radiography, using multidetector-row computed tomography as the reference. Investig Radiol 46:471–477
    • (2011) Investig Radiol , vol.46 , pp. 471-477
    • Yamada, Y.1    Jinzaki, M.2    Hasegawa, I.3
  • 13
    • 84875222125 scopus 로고    scopus 로고
    • Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease
    • COI: 1:STN:280:DC%2BC3s7lvFOmsQ%3D%3D, PID: 23177084
    • Lee G, Jeong YJ, Kim KI et al (2013) Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease. Clin Radiol 68:376–382
    • (2013) Clin Radiol , vol.68 , pp. 376-382
    • Lee, G.1    Jeong, Y.J.2    Kim, K.I.3
  • 14
    • 84880329808 scopus 로고    scopus 로고
    • Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference
    • PID: 23515916
    • Yamada Y, Jinzaki M, Hashimoto M et al (2013) Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference. Eur Radiol 23:2118–2126
    • (2013) Eur Radiol , vol.23 , pp. 2118-2126
    • Yamada, Y.1    Jinzaki, M.2    Hashimoto, M.3
  • 15
    • 84871689360 scopus 로고    scopus 로고
    • Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society
    • PID: 23070270
    • Naidich DP, Bankier AA, MacMahon H et al (2013) Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society. Radiology 266:304–317
    • (2013) Radiology , vol.266 , pp. 304-317
    • Naidich, D.P.1    Bankier, A.A.2    MacMahon, H.3
  • 16
    • 65349125981 scopus 로고    scopus 로고
    • Detectability of peripheral lung cancer on chest radiographs: effect of the size, location and extent of ground-glass opacity
    • COI: 1:STN:280:DC%2BD1M3jsVOlsQ%3D%3D, PID: 19029222
    • Hayashi H, Ashizawa K, Uetani M et al (2009) Detectability of peripheral lung cancer on chest radiographs: effect of the size, location and extent of ground-glass opacity. Br J Radiol 82:272–278
    • (2009) Br J Radiol , vol.82 , pp. 272-278
    • Hayashi, H.1    Ashizawa, K.2    Uetani, M.3
  • 17
    • 84901660798 scopus 로고    scopus 로고
    • Optimal image reconstruction for detection and characterization of small pulmonary nodules during low-dose CT
    • PID: 24658869
    • Hashemi S, Mehrez H, Cobbold RS, Paul NS (2014) Optimal image reconstruction for detection and characterization of small pulmonary nodules during low-dose CT. Eur Radiol. doi:10.1007/s00330-014-3142-9
    • (2014) Eur Radiol
    • Hashemi, S.1    Mehrez, H.2    Cobbold, R.S.3    Paul, N.S.4
  • 18
    • 84879507000 scopus 로고    scopus 로고
    • Lung cancer detection with digital chest tomosynthesis: baseline results from the observational study SOS
    • PID: 23612466
    • Terzi A, Bertolaccini L, Viti A et al (2013) Lung cancer detection with digital chest tomosynthesis: baseline results from the observational study SOS. J Thorac Oncol 8:685–692
    • (2013) J Thorac Oncol , vol.8 , pp. 685-692
    • Terzi, A.1    Bertolaccini, L.2    Viti, A.3
  • 19
    • 84893312213 scopus 로고    scopus 로고
    • Chest tomosynthesis: technical and clinical perspectives
    • PID: 24481756
    • Johnsson AA, Vikgren J, Bath M (2014) Chest tomosynthesis: technical and clinical perspectives. Semin Respir Crit Care Med 35:17–26
    • (2014) Semin Respir Crit Care Med , vol.35 , pp. 17-26
    • Johnsson, A.A.1    Vikgren, J.2    Bath, M.3
  • 20
    • 84866696080 scopus 로고    scopus 로고
    • Experimental study of detection of nodules showing ground-glass opacity and radiation dose by using anthropomorphic chest phantom: digital tomosynthesis and multidetector CT
    • PID: 22992600
    • Zhao F, Zeng Y, Peng G et al (2012) Experimental study of detection of nodules showing ground-glass opacity and radiation dose by using anthropomorphic chest phantom: digital tomosynthesis and multidetector CT. J Comput Assist Tomogr 36:523–527
    • (2012) J Comput Assist Tomogr , vol.36 , pp. 523-527
    • Zhao, F.1    Zeng, Y.2    Peng, G.3
  • 21
    • 84866127866 scopus 로고    scopus 로고
    • Comparison between chest digital tomosynthesis and CT as a screening method to detect artificial pulmonary nodules: a phantom study
    • COI: 1:STN:280:DC%2BC38vntValuw%3D%3D, PID: 22422390
    • Gomi T, Nakajima M, Fujiwara H et al (2012) Comparison between chest digital tomosynthesis and CT as a screening method to detect artificial pulmonary nodules: a phantom study. Br J Radiol 85:e622–e629
    • (2012) Br J Radiol , vol.85 , pp. e622-e629
    • Gomi, T.1    Nakajima, M.2    Fujiwara, H.3
  • 22
    • 77957365354 scopus 로고    scopus 로고
    • Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography
    • PID: 20851944
    • Kim EY, Chung MJ, Lee HY, Koh WJ, Jung HN, Lee KS (2010) Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography. Radiology 257:269–277
    • (2010) Radiology , vol.257 , pp. 269-277
    • Kim, E.Y.1    Chung, M.J.2    Lee, H.Y.3    Koh, W.J.4    Jung, H.N.5    Lee, K.S.6
  • 23
    • 77956482391 scopus 로고    scopus 로고
    • The value of digital tomosynthesis in the diagnosis of suspected pulmonary lesions on chest radiography: analysis of diagnostic accuracy and confidence
    • PID: 20591695
    • Quaia E, Baratella E, Cioffi V et al (2010) The value of digital tomosynthesis in the diagnosis of suspected pulmonary lesions on chest radiography: analysis of diagnostic accuracy and confidence. Acad Radiol 17:1267–1274
    • (2010) Acad Radiol , vol.17 , pp. 1267-1274
    • Quaia, E.1    Baratella, E.2    Cioffi, V.3
  • 24
    • 0036897238 scopus 로고    scopus 로고
    • Measurement of localized ground-glass attenuation on thin-section computed tomography images: correlation with the progression of bronchioloalveolar carcinoma of the lung
    • Nagao M, Murase K, Yasuhara Y et al (2002) Measurement of localized ground-glass attenuation on thin-section computed tomography images: correlation with the progression of bronchioloalveolar carcinoma of the lung. Investig Radiol 37:692–697
    • (2002) Investig Radiol , vol.37 , pp. 692-697
    • Nagao, M.1    Murase, K.2    Yasuhara, Y.3
  • 25
    • 84864373822 scopus 로고    scopus 로고
    • Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT
    • PID: 22692035
    • McCollough CH, Chen GH, Kalender W et al (2012) Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. Radiology 264:567–580
    • (2012) Radiology , vol.264 , pp. 567-580
    • McCollough, C.H.1    Chen, G.H.2    Kalender, W.3
  • 26
    • 43649092041 scopus 로고    scopus 로고
    • Ground-glass opacities on thin-section helical CT: differentiation between bronchioloalveolar carcinoma and atypical adenomatous hyperplasia
    • PID: 18430856
    • Oda S, Awai K, Liu D et al (2008) Ground-glass opacities on thin-section helical CT: differentiation between bronchioloalveolar carcinoma and atypical adenomatous hyperplasia. AJR Am J Roentgenol 190:1363–1368
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 1363-1368
    • Oda, S.1    Awai, K.2    Liu, D.3
  • 27
    • 35449003214 scopus 로고    scopus 로고
    • Differential diagnosis of ground-glass opacity nodules: CT number analysis by three-dimensional computerized quantification
    • PID: 17573486
    • Ikeda K, Awai K, Mori T, Kawanaka K, Yamashita Y, Nomori H (2007) Differential diagnosis of ground-glass opacity nodules: CT number analysis by three-dimensional computerized quantification. Chest 132:984–990
    • (2007) Chest , vol.132 , pp. 984-990
    • Ikeda, K.1    Awai, K.2    Mori, T.3    Kawanaka, K.4    Yamashita, Y.5    Nomori, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.