-
1
-
-
0034802243
-
Determination of regional ventilation and perfusion in the lung using xenon and computed tomography
-
Kreck TC, Krueger MA, Altemeier WA, Sinclair SE, Robertson HT, Shade ED, Hildebrandt J, Lamm WJ, Frazer DA, Polissar NL, Hlastala MP: Determination of regional ventilation and perfusion in the lung using xenon and computed tomography. J Appl Physiol. 2001;91(4):1741-1749.
-
(2001)
J Appl Physiol
, vol.91
, Issue.4
, pp. 1741-1749
-
-
Kreck, T.C.1
Krueger, M.A.2
Altemeier, W.A.3
Sinclair, S.E.4
Robertson, H.T.5
Shade, E.D.6
Hildebrandt, J.7
Lamm, W.J.8
Frazer, D.A.9
Polissar, N.L.10
Hlastala, M.P.11
-
2
-
-
0035143503
-
Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs
-
Marcucci C, Nyhan D, Simon BA: Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs. J Appl Physiol. 2001;90(2):421-430.
-
(2001)
J Appl Physiol
, vol.90
, Issue.2
, pp. 421-430
-
-
Marcucci, C.1
Nyhan, D.2
Simon, B.A.3
-
3
-
-
23744510690
-
Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies
-
Chon D, Simon BA, Beck KC, Shikata H, Saba OI, Won C, Hoffman EA: Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies. Respir Physiol Neurobiol. 2005;148(1-2):65-83.
-
(2005)
Respir Physiol Neurobiol
, vol.148
, Issue.1-2
, pp. 65-83
-
-
Chon, D.1
Simon, B.A.2
Beck, K.C.3
Shikata, H.4
Saba, O.I.5
Won, C.6
Hoffman, E.A.7
-
4
-
-
49049090606
-
Xenon ventilation CT with a dual-energy technique of dual-source CT: Initial experience
-
Chae EJ, Seo JB, Goo HW, Kim N, Song KS, Lee SD, Hong SJ, Krauss B: Xenon ventilation CT with a dual-energy technique of dual-source CT: initial experience. Radiology. 2008;248(2):615-624.
-
(2008)
Radiology
, vol.248
, Issue.2
, pp. 615-624
-
-
Chae, E.J.1
Seo, J.B.2
Goo, H.W.3
Kim, N.4
Song, K.S.5
Lee, S.D.6
Hong, S.J.7
Krauss, B.8
-
5
-
-
31444454089
-
First performance evaluation of a dual-source CT (DSCT) system
-
Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Suss C, Grasruck M, Stierstorfer K, Krauss B, Raupach R, Primak AN, Kuttner A, Achenbach S, Becker C, Kopp A, Ohnesorge BM: First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16(2):256-268.
-
(2006)
Eur Radiol
, vol.16
, Issue.2
, pp. 256-268
-
-
Flohr, T.G.1
McCollough, C.H.2
Bruder, H.3
Petersilka, M.4
Gruber, K.5
Suss, C.6
Grasruck, M.7
Stierstorfer, K.8
Krauss, B.9
Raupach, R.10
Primak, A.N.11
Kuttner, A.12
Achenbach, S.13
Becker, C.14
Kopp, A.15
Ohnesorge, B.M.16
-
6
-
-
34248673159
-
Material differentiation by dual energy CT: Initial experience
-
Johnson TR, Krauss B, Sedlmair M, Grasruck M, Bruder H, Morhard D, Fink C, Weckbach S, Lenhard M, Schmidt B, Flohr T, Reiser MF, Becker CR: Material differentiation by dual energy CT: initial experience. Eur Radiol. 2007;17(6):1510-1517.
-
(2007)
Eur Radiol
, vol.17
, Issue.6
, pp. 1510-1517
-
-
Johnson, T.R.1
Krauss, B.2
Sedlmair, M.3
Grasruck, M.4
Bruder, H.5
Morhard, D.6
Fink, C.7
Weckbach, S.8
Lenhard, M.9
Schmidt, B.10
Flohr, T.11
Reiser, M.F.12
Becker, C.R.13
-
7
-
-
51649115502
-
Xenon ventilation CT using a dual-source dual-energy technique: Dynamic ventilation abnormality in a child with bronchial atresia
-
Goo HW, Chae EJ, Seo JB, Hong SJ: Xenon ventilation CT using a dual-source dual-energy technique: dynamic ventilation abnormality in a child with bronchial atresia. Pediatr Radiol. 2008;38(10):1113-1116.
-
(2008)
Pediatr Radiol
, vol.38
, Issue.10
, pp. 1113-1116
-
-
Goo, H.W.1
Chae, E.J.2
Seo, J.B.3
Hong, S.J.4
-
8
-
-
77952680664
-
Collateral ventilation in a canine model with bronchial obstruction: Assessment with xenon-enhanced dual-energy CT
-
Chae EJ, Seo JB, Kim N, Song KS, Shin JH, Kim TH, Lee Y: Collateral ventilation in a canine model with bronchial obstruction: assessment with xenon-enhanced dual-energy CT. Radiology. 2010;255(3):790-798.
-
(2010)
Radiology
, vol.255
, Issue.3
, pp. 790-798
-
-
Chae, E.J.1
Seo, J.B.2
Kim, N.3
Song, K.S.4
Shin, J.H.5
Kim, T.H.6
Lee, Y.7
-
9
-
-
77952470631
-
Xenon ventilation imaging using dual-energy computed tomography in asthmatics: Initial experience
-
Chae EJ, Seo JB, Lee J, Kim N, Goo HW, Lee HJ, Lee CW, Ra SW, Oh YM, Cho YS: Xenon ventilation imaging using dual-energy computed tomography in asthmatics: initial experience. Invest Radiol. 2010;45(6):354-361.
-
(2010)
Invest Radiol
, vol.45
, Issue.6
, pp. 354-361
-
-
Chae, E.J.1
Seo, J.B.2
Lee, J.3
Kim, N.4
Goo, H.W.5
Lee, H.J.6
Lee, C.W.7
Ra, S.W.8
Oh, Y.M.9
Cho, Y.S.10
-
10
-
-
77956406281
-
Xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans: Correlation of xenon and CT density values with pulmonary function test results
-
Goo HW, Yang DH, Hong SJ, Yu J, Kim BJ, Seo JB, Chae EJ, Lee J, Krauss B: Xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans: correlation of xenon and CT density values with pulmonary function test results. Pediatr Radiol. 2010;40(9):1490-1497.
-
(2010)
Pediatr Radiol
, vol.40
, Issue.9
, pp. 1490-1497
-
-
Goo, H.W.1
Yang, D.H.2
Hong, S.J.3
Yu, J.4
Kim, B.J.5
Seo, J.B.6
Chae, E.J.7
Lee, J.8
Krauss, B.9
-
11
-
-
77956114536
-
Chronic obstructive pulmonary disease: Quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique
-
Park EA, Goo JM, Park SJ, Lee HJ, Lee CH, Park CM, Yoo CG, Kim JH: Chronic obstructive pulmonary disease: quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique. Radiology. 2010;256(3):985-997.
-
(2010)
Radiology
, vol.256
, Issue.3
, pp. 985-997
-
-
Park, E.A.1
Goo, J.M.2
Park, S.J.3
Lee, H.J.4
Lee, C.H.5
Park, C.M.6
Yoo, C.G.7
Kim, J.H.8
-
12
-
-
0017343087
-
Xenon and krypton as radiographic inhalation contrast media with computerized tomography: Preliminary note
-
Winkler SS, Holden JE, Sackett JF, Flemming DC, Alexander SC: Xenon and krypton as radiographic inhalation contrast media with computerized tomography: preliminary note. Invest Radiol. 1977;12(1):19-20.
-
(1977)
Invest Radiol
, vol.12
, Issue.1
, pp. 19-20
-
-
Winkler, S.S.1
Holden, J.E.2
Sackett, J.F.3
Flemming, D.C.4
Alexander, S.C.5
-
13
-
-
0001101644
-
The anesthetic properties of xenon in animals and human beings, with additional observations on krypton
-
Cullen SC, Gross EG: The anesthetic properties of xenon in animals and human beings, with additional observations on krypton. Science. 1951;113(2942):580-582.
-
(1951)
Science
, vol.113
, Issue.2942
, pp. 580-582
-
-
Cullen, S.C.1
Gross, E.G.2
-
14
-
-
84861312743
-
Krypton ventilation imaging using dual-energy CT in chronic obstructive pulmonary disease patients: Initial experience
-
Hachulla AL, Pontana F, Wemeau-Stervinou L, Khung S, Faivre JB, Wallaert B, Cazaubon JF, Duhamel A, Perez T, Devos P, Remy J, Remy-Jardin M: Krypton ventilation imaging using dual-energy CT in chronic obstructive pulmonary disease patients: initial experience. Radiology. 2012;263(1):253-259.
-
(2012)
Radiology
, vol.263
, Issue.1
, pp. 253-259
-
-
Hachulla, A.L.1
Pontana, F.2
Wemeau-Stervinou, L.3
Khung, S.4
Faivre, J.B.5
Wallaert, B.6
Cazaubon, J.F.7
Duhamel, A.8
Perez, T.9
Devos, P.10
Remy, J.11
Remy-Jardin, M.12
-
16
-
-
56149087454
-
Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: Initial experience
-
Chae EJ, Song JW, Seo JB, Krauss B, Jang YM, Song KS: Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: initial experience. Radiology. 2008;249(2):671-681.
-
(2008)
Radiology
, vol.249
, Issue.2
, pp. 671-681
-
-
Chae, E.J.1
Song, J.W.2
Seo, J.B.3
Krauss, B.4
Jang, Y.M.5
Song, K.S.6
-
17
-
-
34147169594
-
Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements
-
Chon D, Beck KC, Simon BA, Shikata H, Saba OI, Hoffman EA: Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements. J Appl Physiol. 2007;102(4):1535-1544.
-
(2007)
J Appl Physiol
, vol.102
, Issue.4
, pp. 1535-1544
-
-
Chon, D.1
Beck, K.C.2
Simon, B.A.3
Shikata, H.4
Saba, O.I.5
Hoffman, E.A.6
-
18
-
-
79956209432
-
Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits
-
Zhang LJ, Wang ZJ, Lu L, Zhu K, Chai X, Zhao YE, Peng J, Lu GM: Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits. Eur J Radiol. 2011;78(2):266-271.
-
(2011)
Eur J Radiol
, vol.78
, Issue.2
, pp. 266-271
-
-
Zhang, L.J.1
Wang, Z.J.2
Lu, L.3
Zhu, K.4
Chai, X.5
Zhao, Y.E.6
Peng, J.7
Lu, G.M.8
|