메뉴 건너뛰기




Volumn 263, Issue 1, 2012, Pages 253-259

Krypton ventilation imaging using dual-energy CT in chronic obstructive pulmonary disease patients: Initial experience

Author keywords

[No Author keywords available]

Indexed keywords

KRYPTON; DIAGNOSTIC AGENT;

EID: 84861312743     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.12111211     Document Type: Article
Times cited : (39)

References (29)
  • 2
    • 55349095807 scopus 로고    scopus 로고
    • Lung perfusion with dual-energy multidetector-row CT (MDCT): Feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients
    • Pontana F, Faivre JB, Remy-Jardin M, et al. Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol 2008;15(12):1494-1504.
    • (2008) Acad Radiol , vol.15 , Issue.12 , pp. 1494-1504
    • Pontana, F.1    Faivre, J.B.2    Remy-Jardin, M.3
  • 3
    • 49049090606 scopus 로고    scopus 로고
    • Xenon ventilation CT with a dual-energy technique of dual-source CT: Initial experience
    • Chae EJ, Seo JB, Goo HW, et al. Xenon ventilation CT with a dual-energy technique of dual-source CT: initial experience. Radiology 2008;248(2):615-624.
    • (2008) Radiology , vol.248 , Issue.2 , pp. 615-624
    • Chae, E.J.1    Seo, J.B.2    Goo, H.W.3
  • 4
    • 51649115502 scopus 로고    scopus 로고
    • Xenon ventilation CT using a dual-source dualenergy technique: Dynamic ventilation abnormality in a child with bronchial atresia
    • Goo HW, Chae EJ, Seo JB, Hong SJ. Xenon ventilation CT using a dual-source dualenergy technique: dynamic ventilation abnormality in a child with bronchial atresia. Pediatr Radiol 2008;38(10):1113-1116.
    • (2008) Pediatr Radiol , vol.38 , Issue.10 , pp. 1113-1116
    • Goo, H.W.1    Chae, E.J.2    Seo, J.B.3    Hong, S.J.4
  • 5
    • 77956406281 scopus 로고    scopus 로고
    • Xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans: Correlation of xenon and CT density values with pulmonary function test results
    • Goo HW, Yang DH, Hong SJ, et al. Xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans: correlation of xenon and CT density values with pulmonary function test results. Pediatr Radiol 2010;40(9):1490-1497.
    • (2010) Pediatr Radiol , vol.40 , Issue.9 , pp. 1490-1497
    • Goo, H.W.1    Yang, D.H.2    Hong, S.J.3
  • 6
    • 77956114536 scopus 로고    scopus 로고
    • Chronic obstructive pulmonary disease: Quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique
    • Park EA, Goo JM, Park SJ, et al. Chronic obstructive pulmonary disease: quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique. Radiology 2010;256(3):985-997.
    • (2010) Radiology , vol.256 , Issue.3 , pp. 985-997
    • Park, E.A.1    Goo, J.M.2    Park, S.J.3
  • 7
    • 78650303334 scopus 로고    scopus 로고
    • Pulmonary ventilation and perfusion imaging with dual-energy CT
    • Thieme SF, Hoegl S, Nikolaou K, et al. Pulmonary ventilation and perfusion imaging with dual-energy CT. Eur Radiol 2010;20(12):2882-2889.
    • (2010) Eur Radiol , vol.20 , Issue.12 , pp. 2882-2889
    • Thieme, S.F.1    Hoegl, S.2    Nikolaou, K.3
  • 8
    • 0023144262 scopus 로고
    • Adverse reactions to xenon-enhanced CT cerebral blood flow determination
    • Latchaw RE, Yonas H, Pentheny SL, Gur D. Adverse reactions to xenon-enhanced CT cerebral blood flow determination. Radiology 1987;163(1):251-254. (Pubitemid 17043037)
    • (1987) Radiology , vol.163 , Issue.1 , pp. 251-254
    • Latchaw, R.E.1    Yonas, H.2    Pentheny, S.L.3    Gur, D.4
  • 11
    • 0023219471 scopus 로고
    • Respiratory depression in goats by stable xenon: Implications for CT studies
    • Winkler SS, Nielsen A, Mesina J. Respiratory depression in goats by stable xenon: implications for CT studies. J Comput Assist Tomogr 1987;11(3):496-498. (Pubitemid 17081522)
    • (1987) Journal of Computer Assisted Tomography , vol.11 , Issue.3 , pp. 496-498
    • Winkler, S.S.1    Nielsen, A.2    Mesina, J.3
  • 13
    • 84862507430 scopus 로고    scopus 로고
    • Ann Arbor, Mich: Thomson Reuters, Updated January 14, Accessed July 2009
    • Microdex Poisindex system. Micromedex [database online]. Ann Arbor, Mich: Thomson Reuters, Updated January 14, 2008. http://www.micromedex.com. Accessed July 2009.
    • (2008) Micromedex [Database Online]
  • 14
    • 84862493629 scopus 로고    scopus 로고
    • Paris, France: Accessed 2010
    • Krypton. Gas encyclopaedia. Paris, France: Air Liquide-France, 2009. http://encyclopedia.airliquide.com/encyclopedia.asp?GasID=40&LanguageID= 2&CountryID=19. Accessed 2010.
    • (2009) Krypton. Gas Encyclopaedia
  • 15
    • 84862506791 scopus 로고    scopus 로고
    • Delft, the Netherlands: Accessed 2011
    • Krypton. Delft, the Netherlands: Lenntech BV, 2011. http://www.lenntech. com/fran%E7ais/DATA-PERIO/kr.htm. Accessed 2011.
    • (2011) Krypton
  • 16
    • 0001101644 scopus 로고
    • The anesthetic properties of xenon in animals and human beings, with additional observations on krypton
    • Cullen SC, Gross EG. The anesthetic properties of xenon in animals and human beings, with additional observations on krypton. Science 1951;113(2942):580-582.
    • (1951) Science , vol.113 , Issue.2942 , pp. 580-582
    • Cullen, S.C.1    Gross, E.G.2
  • 17
    • 0017343087 scopus 로고
    • Xenon and krypton as radiographic inhalation contrast media with computerized tomography: preliminary note
    • Winkler SS, Holden JE, Sackett JF, Flemming DC, Alexander SC. Xenon and krypton as radiographic inhalation contrast media with computerized tomography: preliminary note. Invest Radiol 1977;12(1):19-20. (Pubitemid 8058787)
    • (1977) Investigative Radiology , vol.12 , Issue.1 , pp. 19-20
    • Winkler, S.S.1    Holden, J.E.2    Sackett, J.F.3
  • 18
    • 34147169594 scopus 로고    scopus 로고
    • Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements
    • DOI 10.1152/japplphysiol.01235.2005
    • Chon D, Beck KC, Simon BA, Shikata H, Saba OI, Hoffman EA. Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements. J Appl Physiol 2007;102(4):1535-1544. (Pubitemid 46571050)
    • (2007) Journal of Applied Physiology , vol.102 , Issue.4 , pp. 1535-1544
    • Chon, D.1    Beck, K.C.2    Simon, B.A.3    Shikata, H.4    Saba, O.I.5    Hoffman, E.A.6
  • 19
    • 0020108590 scopus 로고
    • One-sample multiple testing procedure for phase II clinical trials
    • Fleming TR. One-sample multiple testing procedure for phase II clinical trials. Biometrics 1982;38(1):143-151.
    • (1982) Biometrics , vol.38 , Issue.1 , pp. 143-151
    • Fleming, T.R.1
  • 21
    • 0027378045 scopus 로고
    • Cause of regional ventilation-perfusion mismatching in patients with idiopathic pulmonary fibrosis: A combined CT and scintigraphic study
    • Strickland NH, Hughes JM, Hart DA, Myers MJ, Lavender JP. Cause of regional ventilation-perfusion mismatching in patients with idiopathic pulmonary fibrosis: a combined CT and scintigraphic study. AJR Am J Roentgenol 1993;161(4):719-725. (Pubitemid 23296618)
    • (1993) American Journal of Roentgenology , vol.161 , Issue.4 , pp. 719-725
    • Strickland, N.H.1    Hughes, J.M.B.2    Hart, D.A.3    Myers, M.J.4    Lavender, J.P.5
  • 22
    • 34250163586 scopus 로고    scopus 로고
    • Coregistered Ventilation and Perfusion SPECT Using Krypton-81m and Tc-99m-Labeled Macroaggregated Albumin With Multislice CT. Utility for Prediction of Postoperative Lung Function in Non-Small Cell Lung Cancer Patients
    • DOI 10.1016/j.acra.2007.03.013, PII S107663320700178X
    • Ohno Y, Koyama H, Takenaka D, et al. Coregistered ventilation and perfusion SPECT using krypton-81m and Tc-99m-labeled macroaggregated albumin with multislice CT utility for prediction of postoperative lung function in non-small cell lung cancer patients. Acad Radiol 2007;14(7):830-838. (Pubitemid 46898851)
    • (2007) Academic Radiology , vol.14 , Issue.7 , pp. 830-838
    • Ohno, Y.1    Koyama, H.2    Takenaka, D.3    Nogami, M.4    Kotani, Y.5    Nishimura, Y.6    Yoshimura, M.7    Yoshikawa, T.8    Sugimura, K.9
  • 26
    • 0024405206 scopus 로고
    • Origin and behaviour of emphysematous bullae
    • Morgan MDL, Edwards CW, Morris J, Matthews HR. Origin and behaviour of emphysematous bullae. Thorax 1989;44(7):533-538. (Pubitemid 19175477)
    • (1989) Thorax , vol.44 , Issue.7 , pp. 533-538
    • Morgan, M.D.L.1    Edwards, C.W.2    Morris, J.3    Matthews, H.R.4
  • 27
    • 77952680664 scopus 로고    scopus 로고
    • Collateral ventilation in a canine model with bronchial obstruction: Assessment with xenon-enhanced dual-energy CT
    • Chae EJ, Seo JB, Kim N, et al. Collateral ventilation in a canine model with bronchial obstruction: assessment with xenon-enhanced dual-energy CT. Radiology 2010;255(3):790-798.
    • (2010) Radiology , vol.255 , Issue.3 , pp. 790-798
    • Chae, E.J.1    Seo, J.B.2    Kim, N.3
  • 28
    • 84862507432 scopus 로고    scopus 로고
    • Department of Human Health Protection and Dosimetry. Paris, France: Institut de Protection et de SÛreté Nucléaire
    • Krypton 85. Department of Human Health Protection and Dosimetry. Paris, France: Institut de Protection et de SÛreté Nucléaire, 2001.
    • (2001) Krypton 85
  • 29
    • 84862507239 scopus 로고    scopus 로고
    • Paris, France: French Institute of Radioprotection and Nuclear Safety
    • Solier L, Boust D. Report 10G03. Paris, France: French Institute of Radioprotection and Nuclear Safety, 2010.
    • (2010) Report 10G03
    • Solier, L.1    Boust, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.