메뉴 건너뛰기




Volumn 78, Issue 2, 2011, Pages 266-271

Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits

Author keywords

Aerosolised iodinated contrast media; Airway obstruction; Dual energy CT; Ventilation imaging

Indexed keywords

GELATIN SPONGE; IOPROMIDE;

EID: 79956209432     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2010.10.029     Document Type: Article
Times cited : (5)

References (28)
  • 1
    • 69549084880 scopus 로고    scopus 로고
    • Hyperpolarized gas MR Imaging of the lung: Current status as a research tool
    • S. Matsuoka, S. Patz, and M.S. Albert Hyperpolarized gas MR Imaging of the lung: current status as a research tool J Thorac Imaging 24 2009 181 188
    • (2009) J Thorac Imaging , vol.24 , pp. 181-188
    • Matsuoka, S.1    Patz, S.2    Albert, M.S.3
  • 2
    • 85047682091 scopus 로고    scopus 로고
    • Pulmonary perfusion and xenon gas exchange in rats: MR imaging with intravenous injection of hyperpolarized 129Xe
    • B. Driehuys, H.E. Möller, Z.I. Cleveland, J. Pollaro, and L.W. Hedlund Pulmonary perfusion and xenon gas exchange in rats: MR imaging with intravenous injection of hyperpolarized 129Xe Radiology 252 2009 386 393
    • (2009) Radiology , vol.252 , pp. 386-393
    • Driehuys, B.1    Möller, H.E.2    Cleveland, Z.I.3    Pollaro, J.4    Hedlund, L.W.5
  • 3
    • 67349104114 scopus 로고    scopus 로고
    • Volumetric xenon-CT imaging of conventional and high-frequency oscillatory ventilation
    • D.G. Mulreany, B.A. Simon, K.J. Murphy, and R.B. Easley Volumetric xenon-CT imaging of conventional and high-frequency oscillatory ventilation Acad Radiol 16 2009 718 725
    • (2009) Acad Radiol , vol.16 , pp. 718-725
    • Mulreany, D.G.1    Simon, B.A.2    Murphy, K.J.3    Easley, R.B.4
  • 6
    • 0035143503 scopus 로고    scopus 로고
    • Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs
    • C. Marcucci, D. Nyhan, and B.A. Simon Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs J Appl Physiol 90 2001 421 430 (Pubitemid 32118898)
    • (2001) Journal of Applied Physiology , vol.90 , Issue.2 , pp. 421-430
    • Marcucci, C.1    Nyhan, D.2    Simon, B.A.3
  • 7
    • 23644462253 scopus 로고    scopus 로고
    • The spatial and temporal heterogeneity of regional ventilation: Comparison of measurements by two high-resolution methods
    • DOI 10.1016/j.resp.2005.05.008, PII S1569904805001394
    • H.T. Robertson, T.C. Kreck, and M.A. Krueger The spatial and temporal heterogeneity of regional ventilation: comparison of measurements by two high-resolution methods Respir Physiol Neurobiol 148 2005 85 95 (Pubitemid 41132751)
    • (2005) Respiratory Physiology and Neurobiology , vol.148 , Issue.SPEC. ISS.1-2 , pp. 85-95
    • Robertson, H.T.1    Kreck, T.C.2    Krueger, M.A.3
  • 8
    • 0036183857 scopus 로고    scopus 로고
    • Subsecond multisection CT of regional pulmonary ventilation
    • DOI 10.1016/S1076-6332(03)80163-0
    • J.K. Tajik, D. Chon, C. Won, B.Q. Tran, and E.A. Hoffman Subsecond multisection CT of regional pulmonary ventilation Acad Radiol 9 2002 130 146 (Pubitemid 34184161)
    • (2002) Academic Radiology , vol.9 , Issue.2 , pp. 130-146
    • Tajik, J.K.1    Chon, D.2    Won, C.3    Tran, B.Q.4    Hoffman, E.A.5
  • 9
    • 51649115502 scopus 로고    scopus 로고
    • Xenon ventilation CT using a dual-source dual-energy technique: Dynamic ventilation abnormality in a child with bronchial atresia
    • H.W. Goo, E.J. Chae, J.B. Seo, and S.J. Hong Xenon ventilation CT using a dual-source dual-energy technique: dynamic ventilation abnormality in a child with bronchial atresia Pediatr Radiol 38 2008 1113 1116
    • (2008) Pediatr Radiol , vol.38 , pp. 1113-1116
    • Goo, H.W.1    Chae, E.J.2    Seo, J.B.3    Hong, S.J.4
  • 10
    • 49049090606 scopus 로고    scopus 로고
    • Xenon ventilation CT with a dual-energy technique of dual-source CT: Initial experience
    • E.J. Chae, J.B. Seo, and H.W. Goo Xenon ventilation CT with a dual-energy technique of dual-source CT: initial experience Radiology 248 2008 615 624
    • (2008) Radiology , vol.248 , pp. 615-624
    • Chae, E.J.1    Seo, J.B.2    Goo, H.W.3
  • 11
    • 67650306387 scopus 로고    scopus 로고
    • Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma
    • S.F. Thieme, T.R. Johnson, and C. Lee Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma AJR Am J Roentgenol 193 2009 144 149
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 144-149
    • Thieme, S.F.1    Johnson, T.R.2    Lee, C.3
  • 12
    • 67650075304 scopus 로고    scopus 로고
    • Pulmonary embolism detection with dual-energy CT: Experimental study of dual-source CT in rabbits
    • L.J. Zhang, Y.E. Zhao, and S.Y. Wu Pulmonary embolism detection with dual-energy CT: experimental study of dual-source CT in rabbits Radiology 252 2009 61 70
    • (2009) Radiology , vol.252 , pp. 61-70
    • Zhang, L.J.1    Zhao, Y.E.2    Wu, S.Y.3
  • 13
    • 71449105418 scopus 로고    scopus 로고
    • Detection of pulmonary embolism by dual energy CT: Correlation with perfusion scintigraphy and histopathological findings in rabbits
    • L.J. Zhang, X. Chai, and S.Y. Wu Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits Eur Radiol 19 2009 1844 1854
    • (2009) Eur Radiol , vol.19 , pp. 1844-1854
    • Zhang, L.J.1    Chai, X.2    Wu, S.Y.3
  • 14
    • 70350003930 scopus 로고    scopus 로고
    • Detection of pulmonary embolism using dual-energy computed tomography and correlation with cardiovascular measurements: A preliminary study
    • L.J. Zhang, G.F. Yang, Y.E. Zhao, C.S. Zhou, and G.M. Lu Detection of pulmonary embolism using dual-energy computed tomography and correlation with cardiovascular measurements: a preliminary study Acta Radiol 50 2009 892 901
    • (2009) Acta Radiol , vol.50 , pp. 892-901
    • Zhang, L.J.1    Yang, G.F.2    Zhao, Y.E.3    Zhou, C.S.4    Lu, G.M.5
  • 15
    • 77749277564 scopus 로고    scopus 로고
    • Dual-energy CT for assessment of the severity of acute pulmonary embolism: Pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio
    • E.J. Chae, J.B. Seo, and Y.M. Jang Dual-energy CT for assessment of the severity of acute pulmonary embolism: pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio AJR Am J Roentgenol 194 2010 604 610
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 604-610
    • Chae, E.J.1    Seo, J.B.2    Jang, Y.M.3
  • 16
    • 77952530864 scopus 로고    scopus 로고
    • Dual source dual energy CT of acute myocardial infarction: Correlation with histopathological findings in a canine model
    • L.J. Zhang, J. Peng, S.Y. Wu, B.M. Yeh, C.S. Zhou, and G.M. Lu Dual source dual energy CT of acute myocardial infarction: correlation with histopathological findings in a canine model Invest Radiol 45 2010 290 297
    • (2010) Invest Radiol , vol.45 , pp. 290-297
    • Zhang, L.J.1    Peng, J.2    Wu, S.Y.3    Yeh, B.M.4    Zhou, C.S.5    Lu, G.M.6
  • 17
    • 54049156093 scopus 로고    scopus 로고
    • Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience
    • B. Ruzsics, H. Lee, P.L. Zwerner, M. Gebregziabher, P. Costello, and U.J. Schoepf Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience Eur Radiol 18 2008 2414 2424
    • (2008) Eur Radiol , vol.18 , pp. 2414-2424
    • Ruzsics, B.1    Lee, H.2    Zwerner, P.L.3    Gebregziabher, M.4    Costello, P.5    Schoepf, U.J.6
  • 18
    • 74749083661 scopus 로고    scopus 로고
    • Dual-energy CT angiography in the evaluation of intracranial aneurysms: Image quality, radiation dose, and comparison with 3D rotational digital subtraction angiography
    • L.J. Zhang, S.Y. Wu, and J.B. Niu Dual-energy CT angiography in the evaluation of intracranial aneurysms: image quality, radiation dose, and comparison with 3D rotational digital subtraction angiography AJR Am J Roentgenol 194 2010 23 30
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 23-30
    • Zhang, L.J.1    Wu, S.Y.2    Niu, J.B.3
  • 19
    • 62649173588 scopus 로고    scopus 로고
    • Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: Comparison with conventional digital subtraction angiography
    • Y. Watanabe, K. Uotani, and T. Nakazawa Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography Eur Radiol 19 2009 1019 1024
    • (2009) Eur Radiol , vol.19 , pp. 1019-1024
    • Watanabe, Y.1    Uotani, K.2    Nakazawa, T.3
  • 20
    • 56149116093 scopus 로고    scopus 로고
    • Endoleaks after endovascular abdominal aortic aneurysm repair: Detection with dual-energy dual-source CT
    • P. Stolzmann, T. Frauenfelder, and T. Pfammatter Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT Radiology 249 2008 682 691
    • (2008) Radiology , vol.249 , pp. 682-691
    • Stolzmann, P.1    Frauenfelder, T.2    Pfammatter, T.3
  • 21
    • 56149119702 scopus 로고    scopus 로고
    • Abdominal aorta: Evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms - Initial observations
    • H. Chandarana, M.C. Godoy, and I. Vlahos Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms - initial observations Radiology 249 2008 692 700
    • (2008) Radiology , vol.249 , pp. 692-700
    • Chandarana, H.1    Godoy, M.C.2    Vlahos, I.3
  • 22
    • 56149087454 scopus 로고    scopus 로고
    • Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: Initial experience
    • E.J. Chae, J.W. Song, J.B. Seo, B. Krauss, Y.M. Jang, and K.S. Song Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: initial experience Radiology 249 2008 671 681
    • (2008) Radiology , vol.249 , pp. 671-681
    • Chae, E.J.1    Song, J.W.2    Seo, J.B.3    Krauss, B.4    Jang, Y.M.5    Song, K.S.6
  • 23
    • 0029085799 scopus 로고
    • Computertomographische messung der lungen ventilation durch inhalation von isovist-300
    • J.T.R. Kloppel Computertomographische messung der lungen ventilation durch inhalation von isovist-300 Rontgenpraxis 48 1995 259 260 [in Germany]
    • (1995) Rontgenpraxis , vol.48 , pp. 259-260
    • Kloppel, J.T.R.1
  • 26
    • 0023144262 scopus 로고
    • Adverse reactions to xenon-enhanced CT cerebral blood flow determination
    • R.E. Latchaw, H. Yonas, S.L. Pentheny, and D. Gur Adverse reactions to xenon-enhanced CT cerebral blood flow determination Radiology 163 1987 251 254 (Pubitemid 17043037)
    • (1987) Radiology , vol.163 , Issue.1 , pp. 251-254
    • Latchaw, R.E.1    Yonas, H.2    Pentheny, S.L.3    Gur, D.4
  • 27
    • 27244448709 scopus 로고    scopus 로고
    • Regional ventilation and lung mechanics using X-ray CT
    • DOI 10.1016/j.acra.2005.07.009, PII S1076633205006483
    • B.A. Simon Regional ventilation and lung mechanics using X-ray CT Acad Radiol 12 2005 1414 1422 (Pubitemid 41512834)
    • (2005) Academic Radiology , vol.12 , Issue.11 , pp. 1414-1422
    • Simon, B.A.1
  • 28
    • 0032720216 scopus 로고    scopus 로고
    • Pulmonary disorders: Ventilation-perfusion MR imaging with animal models
    • Q. Chen, D.L. Levin, and D. Kim Pulmonary disorders: ventilation- perfusion MR imaging with animal models Radiology 213 1999 871 879
    • (1999) Radiology , vol.213 , pp. 871-879
    • Chen, Q.1    Levin, D.L.2    Kim, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.