메뉴 건너뛰기




Volumn 65, Issue , 2015, Pages 257-264

Chemostat-like microfluidic platform for highly sensitive detection of heavy metal ions using microbial biosensors

Author keywords

Chemostat; Gene expression; Heavy metal ions; Microbial biosensor; Microfluidic platform

Indexed keywords

CADMIUM COMPOUNDS; CHEMOSTATS; GENE EXPRESSION; GENES; HEAVY METALS; METAL IONS; METALS; MICROCHANNELS; MICROFLUIDICS; MIXER CIRCUITS; MOLECULES; NUTRIENTS; SYNTHETIC METALS;

EID: 84908644897     PISSN: 09565663     EISSN: 18734235     Source Type: Journal    
DOI: 10.1016/j.bios.2014.10.028     Document Type: Article
Times cited : (70)

References (37)
  • 1
    • 84893837733 scopus 로고    scopus 로고
    • Functional GFP-metallothionein fusion protein from Tetrahymena thermophila: a potential whole-cell biosensor for monitoring heavy metal pollution and a cell model to study metallothionein overproduction effects
    • Amaro F., Turkewitz A.P., Martin-Gonzalez A., Gutierrez J.C. Functional GFP-metallothionein fusion protein from Tetrahymena thermophila: a potential whole-cell biosensor for monitoring heavy metal pollution and a cell model to study metallothionein overproduction effects. Biometals 2014, 27(1):195-205.
    • (2014) Biometals , vol.27 , Issue.1 , pp. 195-205
    • Amaro, F.1    Turkewitz, A.P.2    Martin-Gonzalez, A.3    Gutierrez, J.C.4
  • 2
    • 0031746834 scopus 로고    scopus 로고
    • New unstable variants of green fluorescent protein for studies of transient gene expression in bacteria
    • Andersen J.B., Sternberg C., Poulsen L.K., Bjorn S.P., Givskov M., Molin S. New unstable variants of green fluorescent protein for studies of transient gene expression in bacteria. Appl. Environ. Microb. 1998, 64(6):2240-2246.
    • (1998) Appl. Environ. Microb. , vol.64 , Issue.6 , pp. 2240-2246
    • Andersen, J.B.1    Sternberg, C.2    Poulsen, L.K.3    Bjorn, S.P.4    Givskov, M.5    Molin, S.6
  • 3
    • 0029942351 scopus 로고    scopus 로고
    • Dynamic electrochemistry: methodology and application
    • Anderson J.L., Bowden E.F., Pickup P.G. Dynamic electrochemistry: methodology and application. Anal. Chem. 1996, 68(12):R379-R444.
    • (1996) Anal. Chem. , vol.68 , Issue.12 , pp. R379-R444
    • Anderson, J.L.1    Bowden, E.F.2    Pickup, P.G.3
  • 4
    • 0023308782 scopus 로고
    • Determination of the coefficient of diffusion of cadmium and magnesium vapors in gases by the Stefan method
    • Arefev K.M., Guseva M.A., Khomchenkov B.M. Determination of the coefficient of diffusion of cadmium and magnesium vapors in gases by the Stefan method. High Temp. 1987, 25(2):174-179.
    • (1987) High Temp. , vol.25 , Issue.2 , pp. 174-179
    • Arefev, K.M.1    Guseva, M.A.2    Khomchenkov, B.M.3
  • 7
    • 0029539043 scopus 로고
    • Effects of lead, cadmium, mercury chlorides and aquatic environmental samples on the growth of Escherichia coli
    • Chao X., Jing Y., Heping X. Effects of lead, cadmium, mercury chlorides and aquatic environmental samples on the growth of Escherichia coli. J. Environ. Sci. 1995, 7(4):455-460.
    • (1995) J. Environ. Sci. , vol.7 , Issue.4 , pp. 455-460
    • Chao, X.1    Jing, Y.2    Heping, X.3
  • 8
    • 79955566734 scopus 로고    scopus 로고
    • A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor
    • Charrier T., Chapeau C., Bendria L., Picart P., Daniel P., Thouand G. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor. Anal. Bioanal. Chem. 2011, 400(4):1061-1070.
    • (2011) Anal. Bioanal. Chem. , vol.400 , Issue.4 , pp. 1061-1070
    • Charrier, T.1    Chapeau, C.2    Bendria, L.3    Picart, P.4    Daniel, P.5    Thouand, G.6
  • 9
    • 0034782257 scopus 로고    scopus 로고
    • Heavy metals of relevance to human health induce genomic instability
    • Coen N., Mothersill C., Kadhim M., Wright E.G. Heavy metals of relevance to human health induce genomic instability. J. Pathol. 2001, 195(3):293-299.
    • (2001) J. Pathol. , vol.195 , Issue.3 , pp. 293-299
    • Coen, N.1    Mothersill, C.2    Kadhim, M.3    Wright, E.G.4
  • 12
    • 0034910570 scopus 로고    scopus 로고
    • Microbial biosensors
    • D'Souza S.F. Microbial biosensors. Biosens. Bioelectron. 2001, 16(6):337-353.
    • (2001) Biosens. Bioelectron. , vol.16 , Issue.6 , pp. 337-353
    • D'Souza, S.F.1
  • 14
    • 0035750172 scopus 로고    scopus 로고
    • Toxic metals and oxidative stress part I: mechanisms involved in metal-induced oxidative damage
    • Ercal N., Gurer-Orhan H., Aykin-Burns N. Toxic metals and oxidative stress part I: mechanisms involved in metal-induced oxidative damage. Curr. Top. Med. Chem. 2001, 1(6):529-539.
    • (2001) Curr. Top. Med. Chem. , vol.1 , Issue.6 , pp. 529-539
    • Ercal, N.1    Gurer-Orhan, H.2    Aykin-Burns, N.3
  • 17
    • 58149145737 scopus 로고    scopus 로고
    • A prototype microfluidic chip using fluorescent yeast for detection of toxic compounds
    • Garcia-Alonso J., Greenway G.M., Hardege J.D., Haswell S.J. A prototype microfluidic chip using fluorescent yeast for detection of toxic compounds. Biosens. Bioelectron. 2009, 24(5):1508-1511.
    • (2009) Biosens. Bioelectron. , vol.24 , Issue.5 , pp. 1508-1511
    • Garcia-Alonso, J.1    Greenway, G.M.2    Hardege, J.D.3    Haswell, S.J.4
  • 19
    • 0030131707 scopus 로고    scopus 로고
    • A miniature bioreactor for sensing toxicity using recombinant bioluminescent Escherichia coli cells
    • Gu M.B., Dhurjati P.S., VanDyk T.K., LaRossa R.A. A miniature bioreactor for sensing toxicity using recombinant bioluminescent Escherichia coli cells. Biotechnol. Progr. 1996, 12(3):393-397.
    • (1996) Biotechnol. Progr. , vol.12 , Issue.3 , pp. 393-397
    • Gu, M.B.1    Dhurjati, P.S.2    VanDyk, T.K.3    LaRossa, R.A.4
  • 20
    • 0029898680 scopus 로고    scopus 로고
    • Atomic absorption, atomic emission, and flame emission spectrometry
    • Jackson K.W., Chen G.R. Atomic absorption, atomic emission, and flame emission spectrometry. Anal. Chem. 1996, 68(12):R231-R256.
    • (1996) Anal. Chem. , vol.68 , Issue.12 , pp. R231-R256
    • Jackson, K.W.1    Chen, G.R.2
  • 21
    • 38949108925 scopus 로고    scopus 로고
    • Lead encephalopathy due to traditional medicines. Current
    • Karri S.K., Saper R.B., Kales S.N. Lead encephalopathy due to traditional medicines. Current. Drug Saf. 2008, 3(1):54-59.
    • (2008) Drug Saf. , vol.3 , Issue.1 , pp. 54-59
    • Karri, S.K.1    Saper, R.B.2    Kales, S.N.3
  • 22
    • 79960961710 scopus 로고    scopus 로고
    • Microfluidic device for analyzing preferential chemotaxis and chemoreceptor sensitivity of bacterial cells toward carbon sources
    • Kim M., Kim S.H., Lee S.K., Kim T. Microfluidic device for analyzing preferential chemotaxis and chemoreceptor sensitivity of bacterial cells toward carbon sources. Analyst 2011, 136(16):3238-3243.
    • (2011) Analyst , vol.136 , Issue.16 , pp. 3238-3243
    • Kim, M.1    Kim, S.H.2    Lee, S.K.3    Kim, T.4
  • 23
    • 77957792983 scopus 로고    scopus 로고
    • Microfabricated ratchet structures for concentrating and patterning motile bacterial cells
    • Kim S.Y., Lee E.S., Lee H.J., Lee S.Y., Lee S.K., Kim T. Microfabricated ratchet structures for concentrating and patterning motile bacterial cells. J. Micromech. Microeng. 2010, 20:9.
    • (2010) J. Micromech. Microeng. , vol.20 , pp. 9
    • Kim, S.Y.1    Lee, E.S.2    Lee, H.J.3    Lee, S.Y.4    Lee, S.K.5    Kim, T.6
  • 27
    • 84872541718 scopus 로고    scopus 로고
    • Microfabricated ratchet structure integrated concentrator arrays for synthetic bacterial cell-to-cell communication assays
    • Park S., Hong X.Q., Choi W.S., Kim T. Microfabricated ratchet structure integrated concentrator arrays for synthetic bacterial cell-to-cell communication assays. Lab Chip 2012, 12(20):3914-3922.
    • (2012) Lab Chip , vol.12 , Issue.20 , pp. 3914-3922
    • Park, S.1    Hong, X.Q.2    Choi, W.S.3    Kim, T.4
  • 28
    • 12944273478 scopus 로고    scopus 로고
    • Rapid diffusion of fluorescent tracers into Staphylococcus epidermidis biofilms visualized by time lapse microscopy
    • Rani S.A., Pitts B., Stewart P.S. Rapid diffusion of fluorescent tracers into Staphylococcus epidermidis biofilms visualized by time lapse microscopy. Antimicrob. Agents Chemother. 2005, 49(2):728-732.
    • (2005) Antimicrob. Agents Chemother. , vol.49 , Issue.2 , pp. 728-732
    • Rani, S.A.1    Pitts, B.2    Stewart, P.S.3
  • 29
    • 84887536329 scopus 로고    scopus 로고
    • Bioengineered bioluminescent magnetotactic bacteria as a powerful tool for chip-based whole-cell biosensors
    • Roda A., Cevenini L., Borg S., Michelini E., Calabretta M.M., Schuler D. Bioengineered bioluminescent magnetotactic bacteria as a powerful tool for chip-based whole-cell biosensors. Lab Chip 2013, 13(24):4881-4889.
    • (2013) Lab Chip , vol.13 , Issue.24 , pp. 4881-4889
    • Roda, A.1    Cevenini, L.2    Borg, S.3    Michelini, E.4    Calabretta, M.M.5    Schuler, D.6
  • 31
    • 20444395435 scopus 로고    scopus 로고
    • Whole-cell-reporter-gene-based biosensing systems on a compact disk microfluidics platform
    • Rothert A., Deo S.K., Millner L., Puckett L.G., Madou M.J., Daunert S. Whole-cell-reporter-gene-based biosensing systems on a compact disk microfluidics platform. Anal. Biochem. 2005, 342(1):11-19.
    • (2005) Anal. Biochem. , vol.342 , Issue.1 , pp. 11-19
    • Rothert, A.1    Deo, S.K.2    Millner, L.3    Puckett, L.G.4    Madou, M.J.5    Daunert, S.6
  • 32
    • 0642305641 scopus 로고    scopus 로고
    • Luminescence-based whole-cell-sensing systems for cadmium and lead using genetically engineered bacteria
    • Shetty R.S., Deo S.K., Shah P., Sun Y., Rosen B.P., Daunert S. Luminescence-based whole-cell-sensing systems for cadmium and lead using genetically engineered bacteria. Anal. Bioanal. Chem. 2003, 376(1):11-17.
    • (2003) Anal. Bioanal. Chem. , vol.376 , Issue.1 , pp. 11-17
    • Shetty, R.S.1    Deo, S.K.2    Shah, P.3    Sun, Y.4    Rosen, B.P.5    Daunert, S.6
  • 34
    • 84879841245 scopus 로고    scopus 로고
    • Optimizing cadmium and mercury specificity of CadR-based E-coli biosensors by redesign of CadR
    • Tao H.C., Peng Z.W., Li P.S., Yu T.A., Su J. Optimizing cadmium and mercury specificity of CadR-based E-coli biosensors by redesign of CadR. Biotechnol. Lett. 2013, 35(8):1253-1258.
    • (2013) Biotechnol. Lett. , vol.35 , Issue.8 , pp. 1253-1258
    • Tao, H.C.1    Peng, Z.W.2    Li, P.S.3    Yu, T.A.4    Su, J.5
  • 35
    • 1542363344 scopus 로고    scopus 로고
    • Diffusion coefficients of lead (II) nitrate in nitric acid aqueous solutions at 298K
    • Valente A.J.M., Ribeiro A.C.F., Lobo V.M.M., Jimenez A. Diffusion coefficients of lead (II) nitrate in nitric acid aqueous solutions at 298K. J. Mol. Liq. 2004, 111(1-3):33-38.
    • (2004) J. Mol. Liq. , vol.111 , Issue.1-3 , pp. 33-38
    • Valente, A.J.M.1    Ribeiro, A.C.F.2    Lobo, V.M.M.3    Jimenez, A.4
  • 36
    • 84870835423 scopus 로고    scopus 로고
    • P-Benzoquinone-mediated amperometric biosensor developed with Psychrobacter sp. for toxicity testing of heavy metals
    • Wang X., Liu M., Wang X., Wu Z., Yang L., Xia S., Chen L., Zhao J. p-Benzoquinone-mediated amperometric biosensor developed with Psychrobacter sp. for toxicity testing of heavy metals. Biosens. Bioelectron. 2013, 41:557-562.
    • (2013) Biosens. Bioelectron. , vol.41 , pp. 557-562
    • Wang, X.1    Liu, M.2    Wang, X.3    Wu, Z.4    Yang, L.5    Xia, S.6    Chen, L.7    Zhao, J.8
  • 37
    • 67651098653 scopus 로고    scopus 로고
    • Optimization of a whole-cell cadmium sensor with a toggle gene circuit
    • Wu C.H., Le D., Mulchandani A., Chen W. Optimization of a whole-cell cadmium sensor with a toggle gene circuit. Biotechnol. Prog. 2009, 25(3):898-903.
    • (2009) Biotechnol. Prog. , vol.25 , Issue.3 , pp. 898-903
    • Wu, C.H.1    Le, D.2    Mulchandani, A.3    Chen, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.