메뉴 건너뛰기




Volumn 12, Issue 9, 2014, Pages 1558-1561

Failure of corn trypsin inhibitor to affect the thrombin generation assay in plasma from severe hemophiliacs

Author keywords

Corn trypsin inhibitor; Hemophilia; Inhibitors; Patient monitoring; Thrombin

Indexed keywords

BLOOD CLOTTING FACTOR 8; CORN TRYPSIN INHIBITOR; THROMBIN; THROMBOPLASTIN; TRYPSIN INHIBITOR; UNCLASSIFIED DRUG; TRYPSIN INHIBITOR, ZEA MAYS; VEGETABLE PROTEIN;

EID: 84908507129     PISSN: 15387933     EISSN: 15387836     Source Type: Journal    
DOI: 10.1111/jth.12659     Document Type: Article
Times cited : (16)

References (15)
  • 1
    • 78650492660 scopus 로고    scopus 로고
    • Prospective assessment of thrombin generation test for dose monitoring of bypassing therapy in hemophilia patients with inhibitors undergoing elective surgery
    • Dargaud Y, Lienhart A, Negrier C. Prospective assessment of thrombin generation test for dose monitoring of bypassing therapy in hemophilia patients with inhibitors undergoing elective surgery. Blood 2010; 116: 5734-7.
    • (2010) Blood , vol.116 , pp. 5734-5737
    • Dargaud, Y.1    Lienhart, A.2    Negrier, C.3
  • 5
    • 84902551577 scopus 로고    scopus 로고
    • Evaluation of pre-analytical variables in a commercial thrombin generation assay
    • Rodgers SE, Wong A, Gopal RD, Dale BJ, Duncan EM, McRae SJ. Evaluation of pre-analytical variables in a commercial thrombin generation assay. Thromb Res 2014; 134: 160-4.
    • (2014) Thromb Res , vol.134 , pp. 160-164
    • Rodgers, S.E.1    Wong, A.2    Gopal, R.D.3    Dale, B.J.4    Duncan, E.M.5    McRae, S.J.6
  • 8
    • 33645650134 scopus 로고    scopus 로고
    • Elimination of contact factor activation improves measurement of platelet-dependent thrombin generation by calibrated automated thrombography at low-concentration tissue factor
    • Dargaud Y, Luddington R, Baglin TP. Elimination of contact factor activation improves measurement of platelet-dependent thrombin generation by calibrated automated thrombography at low-concentration tissue factor. J Thromb Haemost 2006; 4:1160-1.
    • (2006) J Thromb Haemost , vol.4 , pp. 1160-1161
    • Dargaud, Y.1    Luddington, R.2    Baglin, T.P.3
  • 9
    • 13244264708 scopus 로고    scopus 로고
    • Clinical measurement of thrombin generation by calibrated automated thrombography requires contact factor inhibition
    • Luddington R, Baglin T. Clinical measurement of thrombin generation by calibrated automated thrombography requires contact factor inhibition. J Thromb Haemost 2004; 2: 1954-9.
    • (2004) J Thromb Haemost , vol.2 , pp. 1954-1959
    • Luddington, R.1    Baglin, T.2
  • 10
    • 41849145377 scopus 로고    scopus 로고
    • Corn trypsin inhibitor in fluorogenic thrombin-generation measurements is only necessary at low tissue factor concentrations and influences the relationship between factor VIII coagulant activity and thrombogram parameters
    • van Veen JJ, Gatt A, Cooper PC, Kitchen S, Bowyer AE, Makris M. Corn trypsin inhibitor in fluorogenic thrombin-generation measurements is only necessary at low tissue factor concentrations and influences the relationship between factor VIII coagulant activity and thrombogram parameters. Blood Coagul Fibrinolysis 2008; 19: 183-9.
    • (2008) Blood Coagul Fibrinolysis , vol.19 , pp. 183-189
    • van Veen, J.J.1    Gatt, A.2    Cooper, P.C.3    Kitchen, S.4    Bowyer, A.E.5    Makris, M.6
  • 12
    • 80052417114 scopus 로고    scopus 로고
    • Towards a recommendation for the standardization of the measurement of platelet-dependent thrombin generation
    • The Subcommittee on Control of Anticoagulation of the SSC of the ISTH. Towards a recommendation for the standardization of the measurement of platelet-dependent thrombin generation. J Thromb Haemost 2011; 9: 1859-61.
    • (2011) J Thromb Haemost , vol.9 , pp. 1859-1861
  • 13
    • 84908533512 scopus 로고    scopus 로고
    • Corn trypsin inhibitor blood sample collection tubes
    • Available at, Accessed 21 May
    • Haematologic Technologies, Inc. Corn trypsin inhibitor blood sample collection tubes. Available at www.haemtech.com/Blood_Collection_Tubes.htm. Accessed 21 May 2014.
    • (2014)
  • 15
    • 84898049593 scopus 로고    scopus 로고
    • Contact activation:important to consider when measuring the contribution of tissue factor-bearing microparticles to thrombin generation using phospholipid-containing reagents
    • Boknas N, Faxalv L, Lindahl TL, Ramstrom S. Contact activation:important to consider when measuring the contribution of tissue factor-bearing microparticles to thrombin generation using phospholipid-containing reagents. J Thromb Haemost 2014; 12:515-8.
    • (2014) J Thromb Haemost , vol.12 , pp. 515-518
    • Boknas, N.1    Faxalv, L.2    Lindahl, T.L.3    Ramstrom, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.