메뉴 건너뛰기




Volumn 40, Issue 3, 2014, Pages 242-250

Evaluation of a novel brachial cuff-based oscillometric method for estimating central systolic pressure in hemodialysis patients

Author keywords

Aortic pressure; Augmentation index; Hemodialysis; Mobil O Graph; Pulse wave velocity; Sphygmocor; Validation

Indexed keywords

ADULT; AORTA PRESSURE; ARTICLE; AUGMENTATION INDEX; COMPARATIVE STUDY; CORRELATION ANALYSIS; END STAGE RENAL DISEASE; FEMALE; HEART RATE; HEMODIALYSIS; HEMODIALYSIS PATIENT; HUMAN; MAJOR CLINICAL STUDY; MALE; NON INVASIVE BLOOD PRESSURE MONITOR; OSCILLOMETRY; PULSE WAVE; SUPINE POSITION; SYSTOLIC BLOOD PRESSURE; TONOMETER; AGED; AORTA; ARTERIAL STIFFNESS; BLOOD FLOW VELOCITY; BLOOD PRESSURE; BLOOD PRESSURE MONITORING; BRACHIAL ARTERY; CALIBRATION; CARDIOVASCULAR DISEASE; KIDNEY FAILURE; KIDNEY FAILURE, CHRONIC; MIDDLE AGED; PATHOLOGY; PATHOPHYSIOLOGY; PROCEDURES; RENAL REPLACEMENT THERAPY; RISK FACTOR; SYSTOLE;

EID: 84908301283     PISSN: 02508095     EISSN: 14219670     Source Type: Journal    
DOI: 10.1159/000367791     Document Type: Article
Times cited : (63)

References (33)
  • 1
    • 34748816785 scopus 로고    scopus 로고
    • How should hypertension be assessed and managed in hemodialysis patients? Home BP, not dialysis unit BP, should be used for managing hypertension
    • Agarwal R: How should hypertension be assessed and managed in hemodialysis patients? Home BP, not dialysis unit BP, should be used for managing hypertension. Semin Dial 2007; 20: 402-405.
    • (2007) Semin Dial , vol.20 , pp. 402-405
    • Agarwal, R.1
  • 2
    • 33745260718 scopus 로고    scopus 로고
    • Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure
    • Agarwal R, Peixoto AJ, Santos SF, Zoccali C: Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure. Clin J Am Soc Nephrol 2006; 1: 389-398.
    • (2006) Clin J Am Soc Nephrol , vol.1 , pp. 389-398
    • Agarwal, R.1    Peixoto, A.J.2    Santos, S.F.3    Zoccali, C.4
  • 3
    • 84856846863 scopus 로고    scopus 로고
    • Ambulatory blood pressure monitoring: An invaluable tool comes of age for patients with chronic kidney disease?
    • Sarafidis PA, Rumjon A, Macdougall IC: Ambulatory blood pressure monitoring: an invaluable tool comes of age for patients with chronic kidney disease? Am J Nephrol 2012; 35: 238-241.
    • (2012) Am J Nephrol , vol.35 , pp. 238-241
    • Sarafidis, P.A.1    Rumjon, A.2    Macdougall, I.C.3
  • 4
    • 70350023806 scopus 로고    scopus 로고
    • Peridialytic, intradialytic, and interdialytic blood pressure measurement in hemodialysis patients
    • Sinha AD, Agarwal R: Peridialytic, intradialytic, and interdialytic blood pressure measurement in hemodialysis patients. Am J Kidney Dis 2009; 54: 788-791.
    • (2009) Am J Kidney Dis , vol.54 , pp. 788-791
    • Sinha, A.D.1    Agarwal, R.2
  • 8
    • 33846071146 scopus 로고    scopus 로고
    • Central blood pressures: Do we need them in the management of cardiovascular disease? Is it a feasible therapeutic target?
    • Protogerou AD, Papaioannou TG, Blacher J, Papamichael CM, Lekakis JP, Safar ME: Central blood pressures: do we need them in the management of cardiovascular disease? Is it a feasible therapeutic target? J Hypertens 2007; 25: 265-272.
    • (2007) J Hypertens , vol.25 , pp. 265-272
    • Protogerou, A.D.1    Papaioannou, T.G.2    Blacher, J.3    Papamichael, C.M.4    Lekakis, J.P.5    Safar, M.E.6
  • 9
    • 84864567365 scopus 로고    scopus 로고
    • Arterial stiffness and pulse pressure in CKD and ESRD
    • Briet M, Boutouyrie P, Laurent S, London GM: Arterial stiffness and pulse pressure in CKD and ESRD. Kidney Int 2012; 82: 388-400.
    • (2012) Kidney Int , vol.82 , pp. 388-400
    • Briet, M.1    Boutouyrie, P.2    Laurent, S.3    London, G.M.4
  • 14
    • 84929732774 scopus 로고    scopus 로고
    • Arterial stiffness: A novel cardiovascular risk factor in kidney disease patients
    • in press
    • Georgianos PI, Sarafidis PA, Lasaridis AN: Arterial stiffness: a novel cardiovascular risk factor in kidney disease patients. Curr Vasc Pharmacol, in press. DOI: 10.2174/ 15701611113119990147.
    • Curr Vasc Pharmacol
    • Georgianos, P.I.1    Sarafidis, P.A.2    Lasaridis, A.N.3
  • 15
    • 83155172357 scopus 로고    scopus 로고
    • Closer to noninvasive out-of-office aortic blood pressure assessment: A time to think and act
    • Protogerou AD, Smulyan H, Safar ME: Closer to noninvasive out-of-office aortic blood pressure assessment: a time to think and act. Hypertension 2011; 58: 765-767.
    • (2011) Hypertension , vol.58 , pp. 765-767
    • Protogerou, A.D.1    Smulyan, H.2    Safar, M.E.3
  • 19
    • 84862078119 scopus 로고    scopus 로고
    • Oscillometric estimation of central blood pressure: Validation of the Mobil-O-Graph in comparison with the SphygmoCor device
    • Weiss W, Gohlisch C, Harsch-Gladisch C, Tolle M, Zidek W, van der Giet M: Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device. Blood Press Monit 2012; 17: 128-131.
    • (2012) Blood Press Monit , vol.17 , pp. 128-131
    • Weiss, W.1    Gohlisch, C.2    Harsch-Gladisch, C.3    Tolle, M.4    Zidek, W.5    Van Der Giet, M.6
  • 20
    • 38749124791 scopus 로고    scopus 로고
    • Vascular stiffness: Its measurement and significance for epidemiologic and outcome studies
    • DeLoach SS, Townsend RR: Vascular stiffness: its measurement and significance for epidemiologic and outcome studies. Clin J Am Soc Nephrol 2008; 3: 184-192.
    • (2008) Clin J Am Soc Nephrol , vol.3 , pp. 184-192
    • Deloach, S.S.1    Townsend, R.R.2
  • 22
    • 77954937153 scopus 로고    scopus 로고
    • Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria
    • Franssen PM, Imholz BP: Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria. Blood Press Monit 2010; 15: 229-231.
    • (2010) Blood Press Monit , vol.15 , pp. 229-231
    • Franssen, P.M.1    Imholz, B.P.2
  • 24
    • 77954957265 scopus 로고    scopus 로고
    • Validation of the mobil-O-Graph: 24 h-blood pressure measurement device
    • Weiss W, Tolle M, Zidek W, van der Giet M: Validation of the mobil-O-Graph: 24 h-blood pressure measurement device. Blood Press Monit 2010; 15: 225-228.
    • (2010) Blood Press Monit , vol.15 , pp. 225-228
    • Weiss, W.1    Tolle, M.2    Zidek, W.3    Van Der Giet, M.4
  • 25
    • 84870278361 scopus 로고    scopus 로고
    • Comparison between Mobil-O-Graph and the SphygmoCor device for central systolic blood pressure estimation: Consensus is required for 'validation protocols'
    • Papaioannou TG, Protogerou A, Stefanadis C: Comparison between Mobil-O-Graph and the SphygmoCor device for central systolic blood pressure estimation: consensus is required for 'validation protocols'. Blood Press Monit 2012; 17: 259-260.
    • (2012) Blood Press Monit , vol.17 , pp. 259-260
    • Papaioannou, T.G.1    Protogerou, A.2    Stefanadis, C.3
  • 28
    • 81155133883 scopus 로고    scopus 로고
    • Quantification of the calibration error in the transfer function-derived central aortic blood pressures
    • Shih YT, Cheng HM, Sung SH, Hu WC, Chen CH: Quantification of the calibration error in the transfer function-derived central aortic blood pressures. Am J Hypertens 2011; 24: 1312-1317.
    • (2011) Am J Hypertens , vol.24 , pp. 1312-1317
    • Shih, Y.T.1    Cheng, H.M.2    Sung, S.H.3    Hu, W.C.4    Chen, C.H.5
  • 29
    • 84877695102 scopus 로고    scopus 로고
    • Oscillometric estimation of aortic pulse wave velocity: Comparison with intra-aortic catheter measurements
    • Hametner B, Wassertheurer S, Kropf J, Mayer C, Eber B, Weber T: Oscillometric estimation of aortic pulse wave velocity: comparison with intra-aortic catheter measurements. Blood Press Monit 2013; 18: 173-176.
    • (2013) Blood Press Monit , vol.18 , pp. 173-176
    • Hametner, B.1    Wassertheurer, S.2    Kropf, J.3    Mayer, C.4    Eber, B.5    Weber, T.6
  • 30
    • 13144277531 scopus 로고    scopus 로고
    • Evaluation of carotidfemoral pulse wave velocity: Influence of timing algorithm and heart rate
    • Millasseau SC, Stewart AD, Patel SJ, Redwood SR, Chowienczyk PJ: Evaluation of carotidfemoral pulse wave velocity: influence of timing algorithm and heart rate. Hypertension 2005; 45: 222-226.
    • (2005) Hypertension , vol.45 , pp. 222-226
    • Millasseau, S.C.1    Stewart, A.D.2    Patel, S.J.3    Redwood, S.R.4    Chowienczyk, P.J.5
  • 31
    • 84896315163 scopus 로고    scopus 로고
    • Aortic pulse wave velocity predicts mortality in chronic kidney disease stages 2-4
    • Baumann M, Wassertheurer S, Suttmann Y, Burkhardt K, Heemann U: Aortic pulse wave velocity predicts mortality in chronic kidney disease stages 2-4. J Hypertens 2014; 32: 899-903.
    • (2014) J Hypertens , vol.32 , pp. 899-903
    • Baumann, M.1    Wassertheurer, S.2    Suttmann, Y.3    Burkhardt, K.4    Heemann, U.5
  • 32
    • 81155139596 scopus 로고    scopus 로고
    • Validation of the noninvasive assessment of central blood pressure by the SphygmoCor and Omron devices against the invasive catheter measurement
    • Ding FH, Fan WX, Zhang RY, Zhang Q, Li Y, Wang JG: Validation of the noninvasive assessment of central blood pressure by the SphygmoCor and Omron devices against the invasive catheter measurement. Am J Hypertens 2011; 24: 1306-1311.
    • (2011) Am J Hypertens , vol.24 , pp. 1306-1311
    • Ding, F.H.1    Fan, W.X.2    Zhang, R.Y.3    Zhang, Q.4    Li, Y.5    Wang, J.G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.