메뉴 건너뛰기




Volumn 18, Issue 3, 2013, Pages 173-176

Oscillometric estimation of aortic pulse wave velocity: Comparison with intra-aortic catheter measurements

Author keywords

aortic stiffness; ARCSolver; Mobil O Graph; oscillometric; pulse wave velocity

Indexed keywords

ADULT; AGED; AORTA BIFURCATION; AORTIC PULSE WAVE VELOCITY; ARTERY CATHETER; ARTICLE; ASCENDING AORTA; BLOOD PRESSURE CUFF; BLOOD PRESSURE MEASUREMENT; CORONARY ARTERY DISEASE; DIASTOLIC BLOOD PRESSURE; ELECTROCARDIOGRAM; FEMALE; FLUOROSCOPY; HEART CATHETERIZATION; HEART RATE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MEAN ARTERIAL PRESSURE; MEASUREMENT ACCURACY; OSCILLOMETER; OSCILLOMETRY; PRIORITY JOURNAL; PULSE WAVE; REPRODUCIBILITY; SYSTOLIC BLOOD PRESSURE; WAVEFORM;

EID: 84877695102     PISSN: 13595237     EISSN: 14735725     Source Type: Journal    
DOI: 10.1097/MBP.0b013e3283614168     Document Type: Article
Times cited : (242)

References (24)
  • 3
    • 49549121356 scopus 로고    scopus 로고
    • Modeling arterial and left ventricular coupling for non-invasive measurements
    • Wassertheurer S, Mayer C, Breitenecker F. Modeling arterial and left ventricular coupling for non-invasive measurements. Simulat Model Pract Theor 2008; 16:988-997.
    • (2008) Simulat Model Pract Theor , vol.16 , pp. 988-997
    • Wassertheurer, S.1    Mayer, C.2    Breitenecker, F.3
  • 4
    • 77954772459 scopus 로고    scopus 로고
    • A new oscillometric method for pulse wave analysis: Comparison with a common tonometric method
    • Wassertheurer S, Kropf J,Weber T, vdGiet M, Baulmann J, Ammer M, et al. A new oscillometric method for pulse wave analysis: comparison with a common tonometric method. J Hum Hypertens 2010; 24:498-504.
    • (2010) J Hum Hypertens , vol.24 , pp. 498-504
    • Wassertheurer, S.1    Kropf, J.2    Weber, T.3    Vdgiet, M.4    Baulmann, J.5    Ammer, M.6
  • 5
    • 84864285716 scopus 로고    scopus 로고
    • Wave reflections, assessed with a novel method for pulse wave separation, are associated with end-organ damage and clinical outcomes
    • Weber T, Wassertheurer S, Rammer M, Haiden A, Hametner B, Eber B. Wave reflections, assessed with a novel method for pulse wave separation, are associated with end-organ damage and clinical outcomes. Hypertension 2012; 60:534-541.
    • (2012) Hypertension , vol.60 , pp. 534-541
    • Weber, T.1    Wassertheurer, S.2    Rammer, M.3    Haiden, A.4    Hametner, B.5    Eber, B.6
  • 6
    • 83155172358 scopus 로고    scopus 로고
    • Validation of a brachial cuff-based method for estimating central systolic blood pressure
    • Weber T, Wassertheurer S, Rammer M, Maurer E, Hametner B, Mayer CC, et al. Validation of a brachial cuff-based method for estimating central systolic blood pressure. Hypertension 2011; 58:825-832.
    • (2011) Hypertension , vol.58 , pp. 825-832
    • Weber, T.1    Wassertheurer, S.2    Rammer, M.3    Maurer, E.4    Hametner, B.5    Mayer, C.C.6
  • 7
    • 84862078119 scopus 로고    scopus 로고
    • Oscillometric estimation of central blood pressure: Validation of the Mobil-O-Graph in comparison with the SphygmoCor device
    • Weiss W, Gohlisch C, Harsch-Gladisch C, Tö lle M, Zidek W, van der Giet M. Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device. Blood Press Monit 2012; 17:128-131.
    • (2012) Blood Press Monit , vol.17 , pp. 128-131
    • Weiss, W.1    Gohlisch, C.2    Harsch-Gladisch, C.3    Tö Lle, M.4    Zidek, W.5    Van Der Giet, M.6
  • 8
    • 84867212869 scopus 로고    scopus 로고
    • 24-h ambulatory recording of aortic pulse wave velocity and central systolic augmentation: A feasibility study
    • Luzardo L, Lujambio I, Sottolano M, da Rosa A, Thijs L, Noboa O, et al. 24-h ambulatory recording of aortic pulse wave velocity and central systolic augmentation: a feasibility study. Hypertens Res 2012; 35:980-987.
    • (2012) Hypertens Res , vol.35 , pp. 980-987
    • Luzardo, L.1    Lujambio, I.2    Sottolano, M.3    Da Rosa, A.4    Thijs, L.5    Noboa, O.6
  • 9
    • 84864285693 scopus 로고    scopus 로고
    • Feasibility and reproducibility of noninvasive 24-h ambulatory aortic blood pressure monitoring with a brachial cuff-based oscillometric device
    • Protogerou AD, Argyris A, Nasothimiou E, Vrachatis D, Papaioannou TG, Tzamouranis D, et al. Feasibility and reproducibility of noninvasive 24-h ambulatory aortic blood pressure monitoring with a brachial cuff-based oscillometric device. Am J Hypertens 2012; 25:876-882.
    • (2012) Am J Hypertens , vol.25 , pp. 876-882
    • Protogerou, A.D.1    Argyris, A.2    Nasothimiou, E.3    Vrachatis, D.4    Papaioannou, T.G.5    Tzamouranis, D.6
  • 11
    • 84893517404 scopus 로고    scopus 로고
    • Central hemodynamics and arterial stiffness during the finals of the world cup soccer championship 2010
    • doi: 10.1016/j.ijcard.2011.11.096 [Epub ahead of print]
    • Reppel M, Franzen K, Bode F, Weil J, Kurowski V, Schneider SA, et al. Central hemodynamics and arterial stiffness during the finals of the world cup soccer championship 2010. Int J Cardiol 2011. doi: 10.1016/j.ijcard.2011.11.096 [Epub ahead of print].
    • (2011) Int J Cardiol
    • Reppel, M.1    Franzen, K.2    Bode, F.3    Weil, J.4    Kurowski, V.5    Schneider, S.A.6
  • 12
    • 68449097466 scopus 로고    scopus 로고
    • Noninvasive determination of carotid-femoral pulse wave velocity depends critically on assessment of travel distance: A comparison with invasive measurement
    • Weber T, Ammer M, Rammer M, Adji A, O'Rourke MF, Wassertheurer S, et al. Noninvasive determination of carotid-femoral pulse wave velocity depends critically on assessment of travel distance: a comparison with invasive measurement. J Hypertens 2009; 27:1624-1630.
    • (2009) J Hypertens , vol.27 , pp. 1624-1630
    • Weber, T.1    Ammer, M.2    Rammer, M.3    Adji, A.4    O'Rourke, M.F.5    Wassertheurer, S.6
  • 14
    • 0033732033 scopus 로고    scopus 로고
    • A validation of the Mobil-O-Graph (version 12) ambulatory blood pressure monitor
    • Jones CR, Taylor K, Chowienzyk P, Poston L, Shennan A. A validation of the Mobil-O-Graph (version 12) ambulatory blood pressure monitor. Blood Press Monit 2000; 5:23-28.
    • (2000) Blood Press Monit , vol.5 , pp. 23-28
    • Jones, C.R.1    Taylor, K.2    Chowienzyk, P.3    Poston, L.4    Shennan, A.5
  • 15
    • 77954957265 scopus 로고    scopus 로고
    • Validation of the Mobil-O-Graph h blood pressure measurement device
    • Weiss W, Tö lle M, Zidek W, van der Giet M. Validation of the Mobil-O-Graph h blood pressure measurement device. Blood Press Monit 2010; 15:225-228.
    • (2010) Blood Press Monit , vol.15 , pp. 225-228
    • Weiss, W.1    Tö Lle, M.2    Zidek, W.3    Van Der Giet, M.4
  • 16
    • 77954937153 scopus 로고    scopus 로고
    • Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria
    • Franssen PML, Imholz BPM. Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria. Blood Press Monit 2010; 15:229-231.
    • (2010) Blood Press Monit , vol.15 , pp. 229-231
    • Franssen, P.M.L.1    Imholz, B.P.M.2
  • 17
    • 77957681696 scopus 로고    scopus 로고
    • Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors 'establishing normal and reference values'
    • Mattace-Raso F, Hofman A, Verwoert GC, Wittemana JC, Wilkinson I, Cockcroft J, et al. Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: 'establishing normal and reference values'. Eur Heart J 2010; 31:2338-2350.
    • (2010) Eur Heart J , vol.31 , pp. 2338-2350
    • Mattace-Raso, F.1    Hofman, A.2    Verwoert, G.C.3    Wittemana, J.C.4    Wilkinson, I.5    Cockcroft, J.6
  • 18
    • 77957238761 scopus 로고    scopus 로고
    • Noninvasive evaluation of left ventricular afterload. Part 1: Pressure and flow measurements and basic principles of wave conduction and reflection
    • Chirinos JA, Segers P. Noninvasive evaluation of left ventricular afterload. Part 1: pressure and flow measurements and basic principles of wave conduction and reflection. Hypertension 2010; 56:555-562.
    • (2010) Hypertension , vol.56 , pp. 555-562
    • Chirinos, J.A.1    Segers, P.2
  • 20
    • 39849101321 scopus 로고    scopus 로고
    • A new oscillometric method for assessment of arterial stiffness: Comparison with tonometric and piezo-electronic methods
    • DOI 10.1097/HJH.0b013e3282f314f7, PII 0000487220080300000022
    • Baulmann J, Schillings U, Rickert S, Uen S, Dü sing R, Illyes M, et al. A new oscillometric method for assessment of arterial stiffness: comparison with tonometric and piezo-electronic methods. J Hypertens 2008; 26:523-528. (Pubitemid 351317262)
    • (2008) Journal of Hypertension , vol.26 , Issue.3 , pp. 523-528
    • Baulmann, J.1    Schillings, U.2    Rickert, S.3    Uen, S.4    Dusing, R.5    Illyes, M.6    Cziraki, A.7    Nickering, G.8    Mengden, T.9
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327:307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 34547615709 scopus 로고    scopus 로고
    • 2007 Guidelines for the management of arterial hypertension: The Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC
    • Mancia G, De Backer G, Dominiczak A, Cifkova R, Fagard R, Germano G, et al. 2007 Guidelines for the management of arterial hypertension: The Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). Eur Heart J 2007; 28:1462-1536.
    • (2007) Eur Heart J , vol.28 , pp. 1462-1536
    • Mancia, G.1    De Backer, G.2    Dominiczak, A.3    Cifkova, R.4    Fagard, R.5    Germano, G.6
  • 23
    • 77954658471 scopus 로고    scopus 로고
    • ARTERY Society guidelines for validation of non-invasive haemodynamic measurement devices: Part 1, arterial pulse wave velocity
    • On behalf of the ARTERY Society
    • Wilkinson IB, McEniery CM, Schillaci G, Boutouyrie P, Segers P, Donald A, Chowienczyk PJ. On behalf of the ARTERY Society. ARTERY Society guidelines for validation of non-invasive haemodynamic measurement devices: Part 1, arterial pulse wave velocity. Artery Res 2010; 4:34-40.
    • (2010) Artery Res , vol.4 , pp. 34-40
    • Wilkinson, I.B.1    McEniery, C.M.2    Schillaci, G.3    Boutouyrie, P.4    Segers, P.5    Donald, A.6    Chowienczyk, P.J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.