메뉴 건너뛰기




Volumn 849, Issue , 2014, Pages 12-18

Monitoring of an esterification reaction by on-line direct liquid sampling mass spectrometry and in-line mid infrared spectrometry with an attenuated total reflectance probe

Author keywords

In line mid infrared spectrometry; On line direct liquid sampling mass spectrometry; Process analysis; Quantitative reaction monitoring; Thermal vaporiser; Trace analysis

Indexed keywords

BATCH REACTORS; ESTERIFICATION; ESTERS; GAS CHROMATOGRAPHY; INFRARED DEVICES; INFRARED SPECTROSCOPY; LEAST SQUARES APPROXIMATIONS; LIQUIDS; MASS SPECTROMETERS; MASS SPECTROMETRY; TRACE ANALYSIS;

EID: 84908069445     PISSN: 00032670     EISSN: 18734324     Source Type: Journal    
DOI: 10.1016/j.aca.2014.08.009     Document Type: Article
Times cited : (6)

References (44)
  • 1
    • 0001199826 scopus 로고
    • Online measurements using mass-spectrometry
    • Walsh M.R., Lapack M.A. Online measurements using mass-spectrometry. ISA Trans. 1995, 34:67-85.
    • (1995) ISA Trans. , vol.34 , pp. 67-85
    • Walsh, M.R.1    Lapack, M.A.2
  • 2
    • 0032900061 scopus 로고    scopus 로고
    • On-line mass spectrometry: a faster route to process monitoring and control
    • Cook K.D., Bennett K.H., Haddix M.L. On-line mass spectrometry: a faster route to process monitoring and control. Ind. Eng. Chem. Res. 1999, 38:1192-1204.
    • (1999) Ind. Eng. Chem. Res. , vol.38 , pp. 1192-1204
    • Cook, K.D.1    Bennett, K.H.2    Haddix, M.L.3
  • 3
    • 0009830810 scopus 로고
    • Process and environmental monitoring using mass spectrometry
    • Nicholas P. Process and environmental monitoring using mass spectrometry. Spectroscopy 1991, 6:36-45.
    • (1991) Spectroscopy , vol.6 , pp. 36-45
    • Nicholas, P.1
  • 4
    • 0010552713 scopus 로고    scopus 로고
    • Mass spectrometry in chemical process analysis
    • Sheffield Academic Press, Sheffield, J.M. Chalmers (Ed.)
    • Colin T.B. Mass spectrometry in chemical process analysis. Spectroscopy in Process Analysis 2000, 209-233. Sheffield Academic Press, Sheffield. J.M. Chalmers (Ed.).
    • (2000) Spectroscopy in Process Analysis , pp. 209-233
    • Colin, T.B.1
  • 5
    • 0019539979 scopus 로고
    • Gas-analysis in the iron making process
    • Smith A., Pettifor M.J. Gas-analysis in the iron making process. Vacuum 1982, 32:175-181.
    • (1982) Vacuum , vol.32 , pp. 175-181
    • Smith, A.1    Pettifor, M.J.2
  • 6
    • 0010587460 scopus 로고    scopus 로고
    • On-line analysis of complex gas mixtures by mass spectrometry
    • Wright R.G. On-line analysis of complex gas mixtures by mass spectrometry. J. Process Anal. Chem. 1998, 4:71-78.
    • (1998) J. Process Anal. Chem. , vol.4 , pp. 71-78
    • Wright, R.G.1
  • 7
    • 0025532629 scopus 로고
    • Online analysis of fuel gas streams in a refinery using process mass-spectrometry
    • Cessna G.D. Online analysis of fuel gas streams in a refinery using process mass-spectrometry. Adv. Instrum. Control 1990, 45:383-389.
    • (1990) Adv. Instrum. Control , vol.45 , pp. 383-389
    • Cessna, G.D.1
  • 8
    • 0029345821 scopus 로고
    • Real-time process and product diagnostics in rapid thermal chemical-vapor-deposition using in-situ mass-spectrometric sampling
    • Tedder L.L., Rubloff G.W., Shareef I., Anderle M., Kim D.H., Parsons G.N. Real-time process and product diagnostics in rapid thermal chemical-vapor-deposition using in-situ mass-spectrometric sampling. J. Vac. Sci. Technol. B 1995, 13:1924-1927.
    • (1995) J. Vac. Sci. Technol. B , vol.13 , pp. 1924-1927
    • Tedder, L.L.1    Rubloff, G.W.2    Shareef, I.3    Anderle, M.4    Kim, D.H.5    Parsons, G.N.6
  • 9
  • 10
    • 0025592008 scopus 로고
    • Mass-spectrometric detection of low-ppm contaminants in sputter process systems at 10-2mbar, using a directly exposed ion-source
    • Koprio J., Muralt P., Rettinghaus G., Strasser G. Mass-spectrometric detection of low-ppm contaminants in sputter process systems at 10-2mbar, using a directly exposed ion-source. Vacuum 1990, 41:2106-2108.
    • (1990) Vacuum , vol.41 , pp. 2106-2108
    • Koprio, J.1    Muralt, P.2    Rettinghaus, G.3    Strasser, G.4
  • 11
    • 0345246154 scopus 로고
    • Possible on-line applications of mass spectrometry in the biological production of flavours
    • Inst. Natl. Recherche Agronomique, Paris, P. Etievant, P. Schreier (Eds.)
    • Heinzle E. Possible on-line applications of mass spectrometry in the biological production of flavours. Bioflavour 95: Analysis - Precursor Studies - Biotechnology (Colloques de l inra, Vol. 75) 1995, 67-80. Inst. Natl. Recherche Agronomique, Paris. P. Etievant, P. Schreier (Eds.).
    • (1995) Bioflavour 95: Analysis - Precursor Studies - Biotechnology (Colloques de l inra, Vol. 75) , pp. 67-80
    • Heinzle, E.1
  • 16
    • 0029290140 scopus 로고
    • Online detection of volatile organic-compounds in air at parts-per-trillion levels by membrane introduction mass-spectrometry
    • Cisper M.E., Gill C.G., Townsend L.E., Hemberger P.H. Online detection of volatile organic-compounds in air at parts-per-trillion levels by membrane introduction mass-spectrometry. Anal. Chem. 1995, 67:1413-1417.
    • (1995) Anal. Chem. , vol.67 , pp. 1413-1417
    • Cisper, M.E.1    Gill, C.G.2    Townsend, L.E.3    Hemberger, P.H.4
  • 17
    • 0028680245 scopus 로고
    • Determination of volatile organic-compounds at the parts-per-trillion level in complex aqueous matrices using membrane introduction mass-spectrometry
    • Bauer S., Solyom D. Determination of volatile organic-compounds at the parts-per-trillion level in complex aqueous matrices using membrane introduction mass-spectrometry. Anal. Chem. 1994, 66:4422-4431.
    • (1994) Anal. Chem. , vol.66 , pp. 4422-4431
    • Bauer, S.1    Solyom, D.2
  • 18
    • 0000820751 scopus 로고
    • Direct determination of organic-compounds in water at parts-per-quadrillion levels by membrane introduction mass-spectrometry
    • Soni M., Bauer S., Amy J.W., Wong P., Cooks R.G. Direct determination of organic-compounds in water at parts-per-quadrillion levels by membrane introduction mass-spectrometry. Anal. Chem. 1995, 67:1409-1412.
    • (1995) Anal. Chem. , vol.67 , pp. 1409-1412
    • Soni, M.1    Bauer, S.2    Amy, J.W.3    Wong, P.4    Cooks, R.G.5
  • 19
    • 0030945794 scopus 로고    scopus 로고
    • Membrane introduction mass spectrometry in a pilot plant: on-line monitoring of fermentation broths
    • Johnson R.C., Srinivasan N., Cooks R.G., Schell D. Membrane introduction mass spectrometry in a pilot plant: on-line monitoring of fermentation broths. Rapid Commun. Mass Spectrom. 1997, 11:363-367.
    • (1997) Rapid Commun. Mass Spectrom. , vol.11 , pp. 363-367
    • Johnson, R.C.1    Srinivasan, N.2    Cooks, R.G.3    Schell, D.4
  • 21
    • 0036137604 scopus 로고    scopus 로고
    • Reversed-phase membrane inlet mass spectrometry applied to the real-time monitoring of low molecular weight alcohols in chloroform
    • Creaser C.S., Lamarca D.G., Brum J., Werner C., New A.P., dos Santos L.M.F. Reversed-phase membrane inlet mass spectrometry applied to the real-time monitoring of low molecular weight alcohols in chloroform. Anal. Chem. 2002, 74:300-304.
    • (2002) Anal. Chem. , vol.74 , pp. 300-304
    • Creaser, C.S.1    Lamarca, D.G.2    Brum, J.3    Werner, C.4    New, A.P.5    dos Santos, L.M.F.6
  • 22
    • 0038111034 scopus 로고    scopus 로고
    • Catalytic hydrodehalogenation of aromatic halides monitored by membrane introduction mass spectrometry
    • Lago R.M., Nagem N.F., Dalmazio I., Augusti R. Catalytic hydrodehalogenation of aromatic halides monitored by membrane introduction mass spectrometry. Rapid Commun. Mass Spectrom. 2003, 17:1507-1510.
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , pp. 1507-1510
    • Lago, R.M.1    Nagem, N.F.2    Dalmazio, I.3    Augusti, R.4
  • 23
    • 0032739655 scopus 로고    scopus 로고
    • Monitoring process-scale reactions using API mass spectrometry
    • Dell'Orco P., Brum J., Matsuoka R., Badlani M., Muske K. Monitoring process-scale reactions using API mass spectrometry. Anal. Chem. 1999, 71:5165-5170.
    • (1999) Anal. Chem. , vol.71 , pp. 5165-5170
    • Dell'Orco, P.1    Brum, J.2    Matsuoka, R.3    Badlani, M.4    Muske, K.5
  • 24
    • 84865780616 scopus 로고    scopus 로고
    • Quantitative real-time monitoring of chemical reactions by autosampling flow injection analysis coupled with atmospheric pressure chemical ionization mass spectrometry
    • Zhu Z.Q., Bartmess J.E., McNally M.E., Hoffman R.M., Cook K.D., Song L.G. Quantitative real-time monitoring of chemical reactions by autosampling flow injection analysis coupled with atmospheric pressure chemical ionization mass spectrometry. Anal. Chem. 2012, 84:7547-7554.
    • (2012) Anal. Chem. , vol.84 , pp. 7547-7554
    • Zhu, Z.Q.1    Bartmess, J.E.2    McNally, M.E.3    Hoffman, R.M.4    Cook, K.D.5    Song, L.G.6
  • 25
    • 18344366356 scopus 로고    scopus 로고
    • Real-time monitoring of a pharmaceutical process reaction using a membrane interface combined with atmospheric pressure chemical ionisation mass spectrometry
    • Clinton R., Creaser C.S., Bryant D. Real-time monitoring of a pharmaceutical process reaction using a membrane interface combined with atmospheric pressure chemical ionisation mass spectrometry. Anal. Chim. Acta 2005, 539:133-140.
    • (2005) Anal. Chim. Acta , vol.539 , pp. 133-140
    • Clinton, R.1    Creaser, C.S.2    Bryant, D.3
  • 26
    • 79954427193 scopus 로고    scopus 로고
    • Characterization of a condensed-phase membrane introduction mass spectrometry (CP-MIMS) interface using a methanol acceptor phase coupled with electrospray ionization for the continuous on-line quantitation of polar, low-volatility analytes at trace levels in complex aqueous samples
    • Duncan K.D., McCauley E.P.B., Krogh E.T., Gill C.G. Characterization of a condensed-phase membrane introduction mass spectrometry (CP-MIMS) interface using a methanol acceptor phase coupled with electrospray ionization for the continuous on-line quantitation of polar, low-volatility analytes at trace levels in complex aqueous samples. Rapid Commun. Mass Spectrom. 2011, 25:1141-1151.
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , pp. 1141-1151
    • Duncan, K.D.1    McCauley, E.P.B.2    Krogh, E.T.3    Gill, C.G.4
  • 28
    • 56149085481 scopus 로고    scopus 로고
    • Real-time, on-line monitoring of organic chemical reactions using extractive electrospray ionization tandem mass spectrometry
    • Zhu L., Gamez G., Chen H.W., Huang H.X., Chingin K., Zenobi R. Real-time, on-line monitoring of organic chemical reactions using extractive electrospray ionization tandem mass spectrometry. Rapid Commun. Mass Spectrom. 2008, 22:2993-2998.
    • (2008) Rapid Commun. Mass Spectrom. , vol.22 , pp. 2993-2998
    • Zhu, L.1    Gamez, G.2    Chen, H.W.3    Huang, H.X.4    Chingin, K.5    Zenobi, R.6
  • 29
    • 70349313496 scopus 로고    scopus 로고
    • Real-time monitoring of chemical reactions by mass spectrometry utilizing a low-temperature plasma probe
    • Ma X., Zhang S., Lin Z., Liu Y., Xing Z., Yang C., Zhang X. Real-time monitoring of chemical reactions by mass spectrometry utilizing a low-temperature plasma probe. Analyst 2009, 134:1863-1867.
    • (2009) Analyst , vol.134 , pp. 1863-1867
    • Ma, X.1    Zhang, S.2    Lin, Z.3    Liu, Y.4    Xing, Z.5    Yang, C.6    Zhang, X.7
  • 30
    • 78049386829 scopus 로고    scopus 로고
    • Ultrasonication-assisted spray ionization mass spectrometry for on-line monitoring of organic reactions
    • Chen T.Y., Chao C.S., Mong K.K.T., Chen Y.C. Ultrasonication-assisted spray ionization mass spectrometry for on-line monitoring of organic reactions. Chem. Commun. 2010, 46:8347-8349.
    • (2010) Chem. Commun. , vol.46 , pp. 8347-8349
    • Chen, T.Y.1    Chao, C.S.2    Mong, K.K.T.3    Chen, Y.C.4
  • 31
    • 84868139292 scopus 로고    scopus 로고
    • Online monitoring of chemical reactions by contactless atmospheric pressure ionization mass spectrometry
    • Hsieh C.H., Chao C.S., Mong K.K.T., Chen Y.C. Online monitoring of chemical reactions by contactless atmospheric pressure ionization mass spectrometry. J. Mass Spectrom. 2012, 47:586-590.
    • (2012) J. Mass Spectrom. , vol.47 , pp. 586-590
    • Hsieh, C.H.1    Chao, C.S.2    Mong, K.K.T.3    Chen, Y.C.4
  • 32
    • 84901705779 scopus 로고    scopus 로고
    • On-line reaction monitoring and mechanistic studies by mass spectrometry: Negishi cross-coupling, hydrogenolysis, and reductive amination
    • Yan X., Sokol E., Li X., Li G., Xu S., Cooks R.G. On-line reaction monitoring and mechanistic studies by mass spectrometry: Negishi cross-coupling, hydrogenolysis, and reductive amination. Angew. Chem. Int. Ed. 2014, 53:5931-5935.
    • (2014) Angew. Chem. Int. Ed. , vol.53 , pp. 5931-5935
    • Yan, X.1    Sokol, E.2    Li, X.3    Li, G.4    Xu, S.5    Cooks, R.G.6
  • 34
    • 11944272761 scopus 로고
    • Inverse sampling valve interface for online process monitoring with a mass-spectrometer
    • Brodbelt J.S., Willis R.S., Chowdhury A.K. Inverse sampling valve interface for online process monitoring with a mass-spectrometer. Anal. Chem. 1992, 64:827-829.
    • (1992) Anal. Chem. , vol.64 , pp. 827-829
    • Brodbelt, J.S.1    Willis, R.S.2    Chowdhury, A.K.3
  • 35
    • 0027007347 scopus 로고
    • On-line measurement of a liquid reactor feed with a mass spectrometer
    • Didden C., Duisings J. On-line measurement of a liquid reactor feed with a mass spectrometer. J. Process Control Qual. 1992, 3:263-271.
    • (1992) J. Process Control Qual. , vol.3 , pp. 263-271
    • Didden, C.1    Duisings, J.2
  • 36
    • 0025270634 scopus 로고
    • Sampling system for mass-spectrometric monitoring of a stream of reaction liquid
    • Tou J.C., Reddy D. Sampling system for mass-spectrometric monitoring of a stream of reaction liquid. Anal. Chim. Acta 1990, 229:9-16.
    • (1990) Anal. Chim. Acta , vol.229 , pp. 9-16
    • Tou, J.C.1    Reddy, D.2
  • 37
    • 0031917625 scopus 로고    scopus 로고
    • Comparison of total vaporisation and dynamic headspace techniques combined with direct mass spectrometric detection for the on-line analysis of liquid process streams
    • Dunn W.B., Townshend A., Green J.D. Comparison of total vaporisation and dynamic headspace techniques combined with direct mass spectrometric detection for the on-line analysis of liquid process streams. Analyst 1998, 123:343-348.
    • (1998) Analyst , vol.123 , pp. 343-348
    • Dunn, W.B.1    Townshend, A.2    Green, J.D.3
  • 38
    • 0036742438 scopus 로고    scopus 로고
    • Quantitation of trace components in liquid process streams by direct liquid sampling mass spectrometry
    • Lancaster J.S., Lynch T.P., Dutton T., Becker E., Beningfield I., Noe M. Quantitation of trace components in liquid process streams by direct liquid sampling mass spectrometry. Analyst 2002, 127:1218-1223.
    • (2002) Analyst , vol.127 , pp. 1218-1223
    • Lancaster, J.S.1    Lynch, T.P.2    Dutton, T.3    Becker, E.4    Beningfield, I.5    Noe, M.6
  • 39
    • 84907484024 scopus 로고    scopus 로고
    • On-line detection and quantification of trace impurities in vaporisable samples by direct liquid introduction process mass spectrometry
    • Owen A.W., Nordon A., Littlejohn D., Lynch T.P., Lancaster J.S., Wright R.G. On-line detection and quantification of trace impurities in vaporisable samples by direct liquid introduction process mass spectrometry. Anal. Methods 2014, 10.1039/c1034ay01064g.
    • (2014) Anal. Methods
    • Owen, A.W.1    Nordon, A.2    Littlejohn, D.3    Lynch, T.P.4    Lancaster, J.S.5    Wright, R.G.6
  • 40
    • 0347091969 scopus 로고    scopus 로고
    • In-line monitoring of esterification using a miniaturised mid-infrared spectrometer
    • McGill C.A., Ferguson R.H., Donoghue K., Nordon A., Littlejohn D. In-line monitoring of esterification using a miniaturised mid-infrared spectrometer. Analyst 2003, 128:1467-1470.
    • (2003) Analyst , vol.128 , pp. 1467-1470
    • McGill, C.A.1    Ferguson, R.H.2    Donoghue, K.3    Nordon, A.4    Littlejohn, D.5
  • 41
    • 0029857207 scopus 로고    scopus 로고
    • Procrustes analysis for the determination of number of significant masses in gas chromatography mass spectrometry
    • Demir C., Hindmarch P., Brereton R.G. Procrustes analysis for the determination of number of significant masses in gas chromatography mass spectrometry. Analyst 1996, 121:1443-1449.
    • (1996) Analyst , vol.121 , pp. 1443-1449
    • Demir, C.1    Hindmarch, P.2    Brereton, R.G.3
  • 42
    • 0029783105 scopus 로고    scopus 로고
    • Deconvolution and spectral clean-up of two-component mixtures by factor analysis of gas chromatographic mass spectrometric data
    • Hindmarch P., Demir C., Brereton R.G. Deconvolution and spectral clean-up of two-component mixtures by factor analysis of gas chromatographic mass spectrometric data. Analyst 1996, 121:993-1001.
    • (1996) Analyst , vol.121 , pp. 993-1001
    • Hindmarch, P.1    Demir, C.2    Brereton, R.G.3
  • 43
    • 58149130688 scopus 로고    scopus 로고
    • Mass Spectra
    • P.J. Linstrom and W.G. Mallard (Eds.), NIST Chemistry WebBook, NIST Standard Reference Database Number 69, National Institute of Standards and Technology, Gaithersburg MD, 20899, (accessed 22.05.13).
    • NIST Mass Spectrometry Data Center, Mass Spectra, in: P.J. Linstrom and W.G. Mallard (Eds.), NIST Chemistry WebBook, NIST Standard Reference Database Number 69, National Institute of Standards and Technology, Gaithersburg MD, 20899, (accessed 22.05.13). http://webbook.nist.gov/chemistry/.
  • 44
    • 0041845123 scopus 로고    scopus 로고
    • Using design of experiments to select optimum calibration model parameters
    • Flaten G.R., Walmsley A.D. Using design of experiments to select optimum calibration model parameters. Analyst 2003, 128:935-943.
    • (2003) Analyst , vol.128 , pp. 935-943
    • Flaten, G.R.1    Walmsley, A.D.2