메뉴 건너뛰기




Volumn 71, Issue 3, 2014, Pages 127-130

Vitamin D immunoassay systems: A comparison

Author keywords

[No Author keywords available]

Indexed keywords

25 HYDROXYVITAMIN D; COLECALCIFEROL; ERGOCALCIFEROL; VITAMIN D BINDING PROTEIN; VITAMIN D;

EID: 84907955147     PISSN: 09674845     EISSN: None     Source Type: Journal    
DOI: 10.1080/09674845.2014.11978289     Document Type: Article
Times cited : (7)

References (25)
  • 1
    • 76449115194 scopus 로고    scopus 로고
    • Global Vitamin D status and determinants of hypovitaminosis D
    • Mithal A, Wahl DA, Bonjour JP et al.; IOF Committee of Scientific Advisors (CSA) Nutrition Working Group. Global vitamin D status and determinants of hypovitaminosis D. Osteoporos Int 2009; 20 (11): 1807-20.
    • (2009) Osteoporos Int , vol.20 , Issue.11 , pp. 1807-1820
    • Mithal, A.1    Wahl, D.A.2    Bonjour, J.P.3
  • 2
    • 80052220806 scopus 로고    scopus 로고
    • Vitamin D: A d-lightful solution for health
    • Holick MF. Vitamin D: a d-lightful solution for health. J Investig Med 2011; 59 (6): 872-80.
    • (2011) J Investig Med , vol.59 , Issue.6 , pp. 872-880
    • Holick, M.F.1
  • 3
    • 0642275544 scopus 로고    scopus 로고
    • Nutrition. The Vitamin D deficit
    • Stokstad E. Nutrition. The vitamin D deficit. Science 2003; 302 (5652): 1886-8.
    • (2003) Science , vol.302 , Issue.5652 , pp. 1886-1888
    • Stokstad, E.1
  • 4
    • 34250015299 scopus 로고    scopus 로고
    • Vitamin D and calcium supplementation reduces cancer risk: Results of a randomized trial
    • Lappe JM, Travers-Gustafson D, Davies KM, Recker RR, Heaney RP. Vitamin D and calcium supplementation reduces cancer risk: results of a randomized trial. Am J Clin Nutr 2007; 85 (6): 1586-91.
    • (2007) Am J Clin Nutr , vol.85 , Issue.6 , pp. 1586-1591
    • Lappe, J.M.1    Travers-Gustafson, D.2    Davies, K.M.3    Recker, R.R.4    Heaney, R.P.5
  • 5
    • 49449113668 scopus 로고    scopus 로고
    • Measuring 25-hydroxyvitamin D in a clinical environment: Challenges and needs
    • Hollis BW. Measuring 25-hydroxyvitamin D in a clinical environment: challenges and needs. Am J Clin Nutr 2008; 88 (2): 507S-510S.
    • (2008) Am J Clin Nutr , vol.88 , Issue.2 , pp. 507S-510S
    • Hollis, B.W.1
  • 6
    • 84860376447 scopus 로고    scopus 로고
    • Approaches to measurement of Vitamin D concentrations-immunoassays
    • Ofenloch-Haehnle B. Approaches to measurement of vitamin D concentrations-immunoassays. Scand J Clin Lab Invest Suppl 2012; 243: 50-3.
    • (2012) Scand J Clin Lab Invest Suppl , vol.243 , pp. 50-53
    • Ofenloch-Haehnle, B.1
  • 7
    • 77951097205 scopus 로고    scopus 로고
    • Measurement of 25-hydroxyvitamin D in the clinical laboratory: Current procedures, performance characteristics and limitations
    • Wallace AM, Gibson S, de la Hunty A, Lamberg-Allardt C, Ashwell M. Measurement of 25-hydroxyvitamin D in the clinical laboratory: current procedures, performance characteristics and limitations. Steroids 2010; 75 (7): 477-88.
    • (2010) Steroids , vol.75 , Issue.7 , pp. 477-488
    • Wallace, A.M.1    Gibson, S.2    De La Hunty, A.3    Lamberg-Allardt, C.4    Ashwell, M.5
  • 8
    • 84860385605 scopus 로고    scopus 로고
    • Metabolism and biomarkers of Vitamin D
    • Jones G. Metabolism and biomarkers of vitamin D. Scand J Clin Lab Invest Suppl 2012; 243: 7-13.
    • (2012) Scand J Clin Lab Invest Suppl , vol.243 , pp. 7-13
    • Jones, G.1
  • 9
    • 70249119574 scopus 로고    scopus 로고
    • An evaluation of automated methods for measurement of serum 25-hydroxyvitamin D
    • Wagner D, Hanwell HE, Vieth R. An evaluation of automated methods for measurement of serum 25-hydroxyvitamin D. Clin Biochem 2009; 42 (15): 1549-56.
    • (2009) Clin Biochem , vol.42 , Issue.15 , pp. 1549-1556
    • Wagner, D.1    Hanwell, H.E.2    Vieth, R.3
  • 10
    • 79960104336 scopus 로고    scopus 로고
    • Evaluation, treatment, and prevention of Vitamin D deficiency: An Endocrine Society clinical practice guideline
    • Holick MF, Binkley NC, Bischoff-Ferrari HA et al.; Endocrine Society. Evaluation, treatment, and prevention of vitamin D deficiency: an Endocrine Society clinical practice guideline. J Clin Endocrinol Metab 2011; 96 (7): 1911-30.
    • (2011) J Clin Endocrinol Metab , vol.96 , Issue.7 , pp. 1911-1930
    • Endocrine Society1    Holick, M.F.2    Binkley, N.C.3    Bischoff-Ferrari, H.A.4
  • 11
    • 83155177078 scopus 로고    scopus 로고
    • Erratum in
    • Erratum in J Clin Endocrinol Metab 2011; 96 (12): 3908.
    • (2011) J Clin Endocrinol Metab , vol.96 , Issue.12 , pp. 3908
  • 13
    • 84892184039 scopus 로고    scopus 로고
    • Effects of Vitamin D supplements on bone mineral density: A systematic review and meta-analysis
    • Reid IR, Bolland MJ, Grey A. Effects of vitamin D supplements on bone mineral density: a systematic review and meta-analysis. Lancet 2014; 383 (9912): 146-55.
    • (2014) Lancet , vol.383 , Issue.9912 , pp. 146-155
    • Reid, I.R.1    Bolland, M.J.2    Grey, A.3
  • 14
    • 84892367471 scopus 로고    scopus 로고
    • Vitamin D supplementation: Bones of contention
    • Rosen CJ. Vitamin D supplementation: bones of contention. Lancet 2014; 383 (9912): 108-10.
    • (2014) Lancet , vol.383 , Issue.9912 , pp. 108-110
    • Rosen, C.J.1
  • 15
    • 80052192159 scopus 로고    scopus 로고
    • Overreporting of Vitamin D deficiency with the Roche Elecsys Vitamin D3 (25-OH) method
    • Connell AB, Jenkins N, Black M, Pasco JA, Kotowicz MA, Schneider HG. Overreporting of vitamin D deficiency with the Roche Elecsys Vitamin D3 (25-OH) method. Pathology 2011; 43 (4): 368-71.
    • (2011) Pathology , vol.43 , Issue.4 , pp. 368-371
    • Connell, A.B.1    Jenkins, N.2    Black, M.3    Pasco, J.A.4    Kotowicz, M.A.5    Schneider, H.G.6
  • 16
    • 84857866069 scopus 로고    scopus 로고
    • State-of-the-art Vitamin D assays: A comparison of automated immunoassays with liquid chromatographytandem mass spectrometry methods
    • Farrell CJ, Martin S, McWhinney B, Straub I, Williams P, Herrmann M. State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatographytandem mass spectrometry methods. Clin Chem 2012; 58 (3): 531-42.
    • (2012) Clin Chem , vol.58 , Issue.3 , pp. 531-542
    • Farrell, C.J.1    Martin, S.2    McWhinney, B.3    Straub, I.4    Williams, P.5    Herrmann, M.6
  • 17
    • 84875474510 scopus 로고    scopus 로고
    • Total Vitamin D assay comparison of the Roche Diagnostics "Vitamin D Total" electrochemiluminescence protein binding assay with the Chromsystems HPLC method in a population with both D2 and D3 forms of Vitamin D
    • Abdel-Wareth L, Haq A, Turner A et al. Total vitamin D assay comparison of the Roche Diagnostics "Vitamin D Total" electrochemiluminescence protein binding assay with the Chromsystems HPLC method in a population with both D2 and D3 forms of vitamin D. Nutrients 2013; 5 (3): 971-80.
    • (2013) Nutrients , vol.5 , Issue.3 , pp. 971-980
    • Abdel-Wareth, L.1    Haq, A.2    Turner, A.3
  • 18
    • 44249122585 scopus 로고    scopus 로고
    • Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference
    • Roth HJ, Schmidt-Gayk H, Weber H, Niederau C. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference. Ann Clin Biochem 2008; 45 (Pt 2): 153-9.
    • (2008) Ann Clin Biochem , vol.45 , pp. 153-159
    • Roth, H.J.1    Schmidt-Gayk, H.2    Weber, H.3    Niederau, C.4
  • 19
    • 77954371712 scopus 로고    scopus 로고
    • Proficiency testing of 25-hydroxyvitamin D (25-OHD) assays
    • Carter GD, Berry JL, Gunter E et al. Proficiency testing of 25-hydroxyvitamin D (25-OHD) assays. J Steroid Biochem Mol Biol 2010; 121 (1-2): 176-9.
    • (2010) J Steroid Biochem Mol Biol , vol.121 , Issue.1-2 , pp. 176-179
    • Carter, G.D.1    Berry, J.L.2    Gunter, E.3
  • 20
    • 77954546834 scopus 로고    scopus 로고
    • Measurement uncertainty of 25-OH Vitamin D determination with different commercially available kits: Impact on the clinical cut offs
    • Cavalier E, Rozet E, Gadisseur R et al. Measurement uncertainty of 25-OH vitamin D determination with different commercially available kits: impact on the clinical cut offs. Osteoporos Int 2010; 21 (6): 1047-51.
    • (2010) Osteoporos Int , vol.21 , Issue.6 , pp. 1047-1051
    • Cavalier, E.1    Rozet, E.2    Gadisseur, R.3
  • 21
    • 80053475780 scopus 로고    scopus 로고
    • Clinical Review: The 2011 report on dietary reference intake for Vitamin D: Where do we go from here?
    • Aloia JF. Clinical Review: The 2011 report on dietary reference intake for vitamin D: where do we go from here? J Clin Endocrinol Metab 2011; 96 (10): 2987-96.
    • (2011) J Clin Endocrinol Metab , vol.96 , Issue.10 , pp. 2987-2996
    • Aloia, J.F.1
  • 22
    • 78650886291 scopus 로고    scopus 로고
    • The 2011 report on dietary reference intakes for calcium and Vitamin D from the Institute of Medicine: What clinicians need to know
    • Ross AC, Manson JE, Abrams SA et al. The 2011 report on dietary reference intakes for calcium and vitamin D from the Institute of Medicine: what clinicians need to know. J Clin Endocrinol Metab 2011; 96 (1): 53-8.
    • (2011) J Clin Endocrinol Metab , vol.96 , Issue.1 , pp. 53-58
    • Ross, A.C.1    Manson, J.E.2    Abrams, S.A.3
  • 23
    • 58149496380 scopus 로고    scopus 로고
    • Standardization of Vitamin D assays: Art or science?
    • Fraser WD. Standardization of vitamin D assays: art or science? Ann Clin Biochem 2009; 46 (Pt 1): 3-4.
    • (2009) Ann Clin Biochem , vol.46 , pp. 3-4
    • Fraser, W.D.1
  • 24
    • 84857827503 scopus 로고    scopus 로고
    • Accuracy of 6 routine 25-hydroxyVitamin D assays: Influence of Vitamin D binding protein concentration
    • Heijboer AC, Blankenstein MA, Kema IP, Buijs MM. Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration. Clin Chem 2012; 58 (3): 543-8.
    • (2012) Clin Chem , vol.58 , Issue.3 , pp. 543-548
    • Heijboer, A.C.1    Blankenstein, M.A.2    Kema, I.P.3    Buijs, M.M.4
  • 25
    • 84855955512 scopus 로고    scopus 로고
    • Development and certification of a standard reference material for Vitamin D metabolites in human serum
    • Phinney KW, Bedner M, Tai SS et al. Development and certification of a standard reference material for vitamin D metabolites in human serum. Anal Chem 2012; 84 (2): 956-62.
    • (2012) Anal Chem , vol.84 , Issue.2 , pp. 956-962
    • Phinney, K.W.1    Bedner, M.2    Tai, S.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.