메뉴 건너뛰기




Volumn 43, Issue 4, 2011, Pages 368-371

Overreporting of vitamin D deficiency with the Roche Elecsys Vitamin D3 (25-OH) method

Author keywords

Cholecalciferol; Electrochemiluminescence; LCMSMS; Vitamin D; Vitamin D deficiency

Indexed keywords


EID: 80052192159     PISSN: 00313025     EISSN: 14653931     Source Type: Journal    
DOI: 10.1097/PAT.0b013e328346431c     Document Type: Article
Times cited : (29)

References (12)
  • 1
    • 34447514029 scopus 로고    scopus 로고
    • Vitamin D deficiency
    • Holick MF. Vitamin D deficiency. N Engl J Med 2007; 357: 266-81.
    • (2007) N Engl J Med , vol.357 , pp. 266-281
    • Holick, M.F.1
  • 2
    • 63249116824 scopus 로고    scopus 로고
    • Calcium and bone health: Position statement for the Australian and New Zealand Bone and Mineral Society, Osteoporosis Australia and the Endocrine Society of Australia
    • Sanders KM, Nowson CA, Kotowicz M, Briffa K, Devine A, Reid IR. Calcium and bone health: position statement for the Australian and New Zealand Bone and Mineral Society, Osteoporosis Australia and the Endocrine Society of Australia. Med J Aust 2009; 190: 316-20.
    • (2009) Med J Aust , vol.190 , pp. 316-320
    • Sanders, K.M.1    Nowson, C.A.2    Kotowicz, M.3    Briffa, K.4    Devine, A.5    Reid, I.R.6
  • 5
    • 77954546834 scopus 로고    scopus 로고
    • Measurement uncertainty of 25-OH vitamin D determination with different commercially available kits: Impact on the clinical cut offs
    • Cavalier E, Rozet E, Gadisseur R, et al. Measurement uncertainty of 25-OH vitamin D determination with different commercially available kits: impact on the clinical cut offs. Osteoporos Int 2010; 21: 1047-51.
    • (2010) Osteoporos Int , vol.21 , pp. 1047-1051
    • Cavalier, E.1    Rozet, E.2    Gadisseur, R.3
  • 6
    • 67650085344 scopus 로고    scopus 로고
    • 25-Hydroxyvitamin D assays: The quest for accuracy
    • Carter GD. 25-Hydroxyvitamin D assays: the quest for accuracy. Clin Chem 2009; 55: 1300-2.
    • (2009) Clin Chem , vol.55 , pp. 1300-1302
    • Carter, G.D.1
  • 7
    • 57149118302 scopus 로고    scopus 로고
    • 3 on the Roche Modular E170 analyzer
    • DOI 10.1373/clinchem.2008.111732
    • Leino A, Turpeinen U, Koskinen P. Automated measurement of 25-OH vitamin D3 on the Roche Modular E170 analyzer. Clin Chem 2008; 54: 2059-62. (Pubitemid 352774041)
    • (2008) Clinical Chemistry , vol.54 , Issue.12 , pp. 2059-2062
    • Leino, A.1    Turpeinen, U.2    Koskinen, P.3
  • 8
    • 85031216625 scopus 로고    scopus 로고
    • Evaluation of the Elecsys Vitamin D3 25-OH Assay on the Roche Modular Analytics E170 Immunoassay Analyser
    • Black M, Jenkins N, Schneider HG. Evaluation of the Elecsys Vitamin D3 25-OH Assay on the Roche Modular Analytics E170 Immunoassay Analyser. Clin Biochem Rev 2007; 28 (Suppl 1): S19.
    • (2007) Clin Biochem Rev , vol.28 , Issue.SUPPL. 1
    • Black, M.1    Jenkins, N.2    Schneider, H.G.3
  • 9
    • 78650905587 scopus 로고    scopus 로고
    • Progress of liquid chromatographymass spectrometry in measurement of vitamin D metabolites and analogues
    • El-Khoury JM, Reineks EZ, Wang S. Progress of liquid chromatographymass spectrometry in measurement of vitamin D metabolites and analogues. Clin Biochem 2011; 44: 66-76.
    • (2011) Clin Biochem , vol.44 , pp. 66-76
    • El-Khoury, J.M.1    Reineks, E.Z.2    Wang, S.3
  • 10
    • 11144262084 scopus 로고    scopus 로고
    • Serum 25-hydroxyvitamin D is unaffected by multiple freeze-thaw cycles
    • DOI 10.1373/clinchem.2004.041954
    • Antoniucci DM, Black DM, Sellmeyer DE. Serum 25-hydroxyvitamin D is unaffected by multiple freeze-thaw cycles. Clin Chem 2005; 51: 258-61. (Pubitemid 40024054)
    • (2005) Clinical Chemistry , vol.51 , Issue.1 , pp. 258-261
    • Antoniucci, D.M.1    Black, D.M.2    Sellmeyer, D.E.3
  • 11
    • 44249122585 scopus 로고    scopus 로고
    • Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference
    • DOI 10.1258/acb.2007.007091
    • Roth HJ, Schmidt-Gayk H, Weber H, Niederau C. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference. Ann Clin Biochem 2008; 45: 153-9. (Pubitemid 351724586)
    • (2008) Annals of Clinical Biochemistry , vol.45 , Issue.2 , pp. 153-159
    • Roth, H.J.1    Schmidt-Gayk, H.2    Weber, H.3    Niederau, C.4
  • 12
    • 70249119574 scopus 로고    scopus 로고
    • An evaluation of automated methods for measurement of serum 25-hydroxyvitamin D
    • Wagner D, Hanwell HE, Vieth R. An evaluation of automated methods for measurement of serum 25-hydroxyvitamin D. Clin Biochem 2009; 42: 1549-56.
    • (2009) Clin Biochem , vol.42 , pp. 1549-1556
    • Wagner, D.1    Hanwell, H.E.2    Vieth, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.