메뉴 건너뛰기




Volumn 205, Issue , 2014, Pages 261-267

Highly sensitive carbon nanotubes-SnO2 nanocomposite sensor for acetone detection in diabetes mellitus breath

Author keywords

Acetone; Carbon nanotubes; Diabetes mellitus; Gas sensor; SnO2

Indexed keywords

CARBON NANOTUBES; CHEMICAL SENSORS;

EID: 84907487359     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.08.082     Document Type: Article
Times cited : (114)

References (43)
  • 1
    • 33646338915 scopus 로고    scopus 로고
    • Breath analysis potential for clinical diagnosis and exposure assessment
    • W. Cao, and Y. Duan Breath analysis potential for clinical diagnosis and exposure assessment Clin. Chem. 52 2006 800 811
    • (2006) Clin. Chem. , vol.52 , pp. 800-811
    • Cao, W.1    Duan, Y.2
  • 2
    • 4544255985 scopus 로고    scopus 로고
    • Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization
    • C. Deng, J. Zhang, X. Yu, W. Zhang, and X. Zhang Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization J. Chromatogr. B 810 2004 269 275
    • (2004) J. Chromatogr. B , vol.810 , pp. 269-275
    • Deng, C.1    Zhang, J.2    Yu, X.3    Zhang, W.4    Zhang, X.5
  • 3
    • 76649112772 scopus 로고    scopus 로고
    • Breath acetone concentration decreases with blood glucose concentration in type i diabetes mellitus patients during hypoglycaemic clamps
    • C. Turner, C. Walton, S. Hoashi, and M. Evans Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps J. Breath Res. 3 2009 046004
    • (2009) J. Breath Res. , vol.3 , pp. 046004
    • Turner, C.1    Walton, C.2    Hoashi, S.3    Evans, M.4
  • 4
    • 72349088828 scopus 로고    scopus 로고
    • A study on breath acetone in diabetic patients using a cavity ringdown breath analyzer: Exploring correlations of breath acetone with blood glucose and glycohemoglobin A1C
    • W. Chuji, A. Mbi, and M. Shepherd A study on breath acetone in diabetic patients using a cavity ringdown breath analyzer: exploring correlations of breath acetone with blood glucose and glycohemoglobin A1C Sens. J. IEEE 10 2010 54 63
    • (2010) Sens. J. IEEE , vol.10 , pp. 54-63
    • Chuji, W.1    Mbi, A.2    Shepherd, M.3
  • 5
    • 29144508524 scopus 로고    scopus 로고
    • A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry
    • C. Turner, P. Spanel, and D. Smith A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry Rapid Commun. Mass Spectrom. 20 2006 61 68
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , pp. 61-68
    • Turner, C.1    Spanel, P.2    Smith, D.3
  • 6
    • 0034320252 scopus 로고    scopus 로고
    • Increased gastrointestinal ethanol production in obese mice: Implications for fatty liver disease pathogenesis
    • K. Cope, T. Risby, and A.M. Diehl Increased gastrointestinal ethanol production in obese mice: implications for fatty liver disease pathogenesis Gastroenterology 119 2000 1340 1347
    • (2000) Gastroenterology , vol.119 , pp. 1340-1347
    • Cope, K.1    Risby, T.2    Diehl, A.M.3
  • 8
    • 32544451157 scopus 로고    scopus 로고
    • Generation of volatile compounds on mouth exposure to urea and sucrose: Implications for exhaled breath analysis
    • P. Spanel, C. Turner, T. Wang, R. Bloor, and D. Smith Generation of volatile compounds on mouth exposure to urea and sucrose: implications for exhaled breath analysis Physiol. Meas. 27 2006 N7 N17
    • (2006) Physiol. Meas. , vol.27 , pp. 7-N17
    • Spanel, P.1    Turner, C.2    Wang, T.3    Bloor, R.4    Smith, D.5
  • 9
    • 84865066944 scopus 로고    scopus 로고
    • The clinical potential of exhaled breath analysis for diabetes mellitus
    • C. Minh Tdo, D.R. Blake, and P.R. Galassetti The clinical potential of exhaled breath analysis for diabetes mellitus Diabetes Res. Clin. Pract. 97 2012 195 205
    • (2012) Diabetes Res. Clin. Pract. , vol.97 , pp. 195-205
    • Minh Tdo, C.1    Blake, D.R.2    Galassetti, P.R.3
  • 10
    • 57849091629 scopus 로고    scopus 로고
    • Analysis of industrial contaminants in indoor air: Part 1. Volatile organic compounds, carbonyl compounds, polycyclic aromatic hydrocarbons and polychlorinated biphenyls
    • R. Barro, J. Regueiro, M. Llompart, and C. Garcia-Jares Analysis of industrial contaminants in indoor air: part 1. Volatile organic compounds, carbonyl compounds, polycyclic aromatic hydrocarbons and polychlorinated biphenyls J. Chromatogr. A 1216 2009 540 566
    • (2009) J. Chromatogr. A , vol.1216 , pp. 540-566
    • Barro, R.1    Regueiro, J.2    Llompart, M.3    Garcia-Jares, C.4
  • 11
    • 0034629474 scopus 로고    scopus 로고
    • Extreme oxygen sensitivity of electronic properties of carbon nanotubes
    • P.G. Collins, K. Bradley, M. Ishigami, and A. Zettl Extreme oxygen sensitivity of electronic properties of carbon nanotubes Science (New York, NY) 287 2000 1801 1804
    • (2000) Science (New York, NY) , vol.287 , pp. 1801-1804
    • Collins, P.G.1    Bradley, K.2    Ishigami, M.3    Zettl, A.4
  • 20
    • 27844602370 scopus 로고    scopus 로고
    • The surface and materials science of tin oxide
    • M. Batzill, and U. Diebold The surface and materials science of tin oxide Prog. Surf. Sci. 79 2005 47 154
    • (2005) Prog. Surf. Sci. , vol.79 , pp. 47-154
    • Batzill, M.1    Diebold, U.2
  • 22
    • 0035923362 scopus 로고    scopus 로고
    • Theory of gas-diffusion controlled sensitivity for thin film semiconductor gas sensor
    • G. Sakai, N. Matsunaga, K. Shimanoe, and N. Yamazoe Theory of gas-diffusion controlled sensitivity for thin film semiconductor gas sensor Sens. Actuators B: Chem. 80 2001 125 131
    • (2001) Sens. Actuators B: Chem. , vol.80 , pp. 125-131
    • Sakai, G.1    Matsunaga, N.2    Shimanoe, K.3    Yamazoe, N.4
  • 26
    • 4143092749 scopus 로고    scopus 로고
    • Low-resistance gas sensors fabricated from multiwalled carbon nanotubes coated with a thin tin oxide layer
    • Y.X. Liang, Y.J. Chen, and T.H. Wang Low-resistance gas sensors fabricated from multiwalled carbon nanotubes coated with a thin tin oxide layer Appl. Phys. Lett. 85 2004 666 668
    • (2004) Appl. Phys. Lett. , vol.85 , pp. 666-668
    • Liang, Y.X.1    Chen, Y.J.2    Wang, T.H.3
  • 29
    • 0032675284 scopus 로고    scopus 로고
    • Interaction between thin-film tin oxide gas sensor and five organic vapors
    • H. Gong, Y.J. Wang, S.C. Teo, and L. Huang Interaction between thin-film tin oxide gas sensor and five organic vapors Sens. Actuators B: Chem. 54 1999 232 235
    • (1999) Sens. Actuators B: Chem. , vol.54 , pp. 232-235
    • Gong, H.1    Wang, Y.J.2    Teo, S.C.3    Huang, L.4
  • 31
    • 0028408829 scopus 로고
    • Modelling and simulation of tin oxide based thick-film gas sensors using Monte Carlo techniques
    • P.D. Skafidas, D.S. Vlachos, and J.N. Avaritsiotis Modelling and simulation of tin oxide based thick-film gas sensors using Monte Carlo techniques Sens. Actuators B: Chem. 19 1994 724 728
    • (1994) Sens. Actuators B: Chem. , vol.19 , pp. 724-728
    • Skafidas, P.D.1    Vlachos, D.S.2    Avaritsiotis, J.N.3
  • 32
    • 0029290679 scopus 로고
    • The effect of humidity on tin-oxide thick-film gas sensors in the presence of reducing and combustible gases
    • D.S. Vlachos, P.D. Skafidas, and J.N. Avaritsiotis The effect of humidity on tin-oxide thick-film gas sensors in the presence of reducing and combustible gases Sens. Actuators B: Chem. 25 1995 491 494
    • (1995) Sens. Actuators B: Chem. , vol.25 , pp. 491-494
    • Vlachos, D.S.1    Skafidas, P.D.2    Avaritsiotis, J.N.3
  • 36
    • 29444440392 scopus 로고    scopus 로고
    • 3-based gas sensors
    • 3-based gas sensors Mater. Lett. 60 2006 952 956
    • (2006) Mater. Lett. , vol.60 , pp. 952-956
    • Jing, Z.1    Wu, S.2
  • 39
    • 33646267666 scopus 로고    scopus 로고
    • Influence of iron addition on ethanol and CO sensing properties of tin oxide prepared with the RGTO technique
    • E. Comini, A. Vomiero, G. Faglia, G.D. Mea, and G. Sberveglieri Influence of iron addition on ethanol and CO sensing properties of tin oxide prepared with the RGTO technique Sens. Actuators B: Chem. 115 2006 561 566
    • (2006) Sens. Actuators B: Chem. , vol.115 , pp. 561-566
    • Comini, E.1    Vomiero, A.2    Faglia, G.3    Mea, G.D.4    Sberveglieri, G.5
  • 40
    • 0032131466 scopus 로고    scopus 로고
    • High sensitivity ethanol gas sensor integrated with a solid-state heater and thermal isolation improvement structure for legal drink-drive limit detecting
    • J.-J. Ho, Y.K. Fang, K.H. Wu, W.T. Hsieh, C.H. Chen, and G.S. Chen High sensitivity ethanol gas sensor integrated with a solid-state heater and thermal isolation improvement structure for legal drink-drive limit detecting Sens. Actuators B: Chem. 50 1998 227 233
    • (1998) Sens. Actuators B: Chem. , vol.50 , pp. 227-233
    • Ho, J.-J.1    Fang, Y.K.2    Wu, K.H.3    Hsieh, W.T.4    Chen, C.H.5    Chen, G.S.6
  • 41
    • 40149093546 scopus 로고    scopus 로고
    • Effect of humidity on the gas sensing property of the tetrapod-shaped ZnO nanopowder sensor
    • Z. Bai, C. Xie, M. Hu, S. Zhang, and D. Zeng Effect of humidity on the gas sensing property of the tetrapod-shaped ZnO nanopowder sensor Mater. Sci. Eng. B 149 2008 12 17
    • (2008) Mater. Sci. Eng. B , vol.149 , pp. 12-17
    • Bai, Z.1    Xie, C.2    Hu, M.3    Zhang, S.4    Zeng, D.5
  • 43
    • 84885482449 scopus 로고    scopus 로고
    • Hydrogen and ethanol sensing properties of molybdenum oxide nanorods based thin films: Effect of electrode metallization and humid ambience
    • N. Illyaskutty, H. Kohler, T. Trautmann, M. Schwotzer, and V.P. Mahadevan Pillai Hydrogen and ethanol sensing properties of molybdenum oxide nanorods based thin films: Effect of electrode metallization and humid ambience Sens. Actuators B: Chem. 187 2013 611 621
    • (2013) Sens. Actuators B: Chem. , vol.187 , pp. 611-621
    • Illyaskutty, N.1    Kohler, H.2    Trautmann, T.3    Schwotzer, M.4    Mahadevan Pillai, V.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.