메뉴 건너뛰기




Volumn 438, Issue , 2015, Pages 241-245

Effect of interference from hemolysis, icterus and lipemia on routine pediatric clinical chemistry assays

Author keywords

Hemolysis; Icterus; Indices; Interference; Lipemia; Pediatric

Indexed keywords

ALANINE AMINOTRANSFERASE; ALBUMIN; ALKALINE PHOSPHATASE; ALPHA FETOPROTEIN; ASPARTATE AMINOTRANSFERASE; BILIRUBIN; CERULOPLASMIN; CHORIONIC GONADOTROPIN; COMPLEMENT COMPONENT C3; COMPLEMENT COMPONENT C4; CREATINE KINASE; CREATINE KINASE MB; ESTRADIOL; FERRIC ION; FERRITIN; FOLIC ACID; GAMMA GLUTAMYLTRANSFERASE; GLUCOSE; HAPTOGLOBIN; HEPATITIS B CORE ANTIGEN; HYDROCORTISONE; IMMUNOGLOBULIN A; IMMUNOGLOBULIN G; IMMUNOGLOBULIN M; INTRALIPID; MAGNESIUM ION; POTASSIUM ION; TRIACYLGLYCEROL LIPASE; VITAMIN D; COMPLEMENT; HEMOGLOBIN; IMMUNOGLOBULIN; LIPID;

EID: 84907485552     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2014.08.008     Document Type: Article
Times cited : (56)

References (14)
  • 1
    • 0030857166 scopus 로고    scopus 로고
    • Errors, mistakes, blunders, outliers, or unacceptable results: how many?
    • Witte D.L., VanNess S.A., Angstadt D.S., Pennell B.J. Errors, mistakes, blunders, outliers, or unacceptable results: how many?. Clin Chem 1997, 43(8 Pt 1):1352-1356.
    • (1997) Clin Chem , vol.43 , Issue.8 , pp. 1352-1356
    • Witte, D.L.1    VanNess, S.A.2    Angstadt, D.S.3    Pennell, B.J.4
  • 2
    • 68149089064 scopus 로고    scopus 로고
    • Interference testing
    • Dimeski G. Interference testing. Clin Biochem Rev 2008, 29(Suppl. 1):S43-S48.
    • (2008) Clin Biochem Rev , vol.29 , pp. S43-S48
    • Dimeski, G.1
  • 4
    • 79953004924 scopus 로고    scopus 로고
    • Evaluation of the interference due to hemoglobin, bilirubin and lipids on Immulite 2500 assays: A practical approach
    • Steen G., Klerk A., Laan K., Eppens E.F. Evaluation of the interference due to hemoglobin, bilirubin and lipids on Immulite 2500 assays: A practical approach. Ann Clin Biochem. 2011, 201;48(Pt 2):170-175.
    • (2011) Ann Clin Biochem. , pp. 170-175
    • Steen, G.1    Klerk, A.2    Laan, K.3    Eppens, E.F.4
  • 5
    • 0027960559 scopus 로고
    • Interferences with clinical laboratory analyses
    • Kroll M.H., Elin R.J. Interferences with clinical laboratory analyses. Clin Chem 1994, 40:1996-2005.
    • (1994) Clin Chem , vol.40 , pp. 1996-2005
    • Kroll, M.H.1    Elin, R.J.2
  • 6
    • 84941841395 scopus 로고
    • Haemolysis as an interference factor in clinical chemistry
    • Sonntag O. Haemolysis as an interference factor in clinical chemistry. J Clin Chem Clin Biochem 1986, 24:127-139.
    • (1986) J Clin Chem Clin Biochem , vol.24 , pp. 127-139
    • Sonntag, O.1
  • 7
    • 7044241205 scopus 로고    scopus 로고
    • Evaluating interference caused by lipemia
    • Kroll M.H. Evaluating interference caused by lipemia. Clin Chem 2004, 50:1968-1969.
    • (2004) Clin Chem , vol.50 , pp. 1968-1969
    • Kroll, M.H.1
  • 8
    • 79959295985 scopus 로고    scopus 로고
    • Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays
    • Ji J.Z., Meng Q.H. Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays. Clin Chim Acta 2011, 412(17-18):1550-1553.
    • (2011) Clin Chim Acta , vol.412 , Issue.17-18 , pp. 1550-1553
    • Ji, J.Z.1    Meng, Q.H.2
  • 9
    • 79951706424 scopus 로고    scopus 로고
    • Effects of hemolysis interferences on routine biochemistry parameters
    • Koseoglu M., Hur A., Atay A., Cuhadar S. Effects of hemolysis interferences on routine biochemistry parameters. Biochem Med (Zagreb) 2011, 21:79-85.
    • (2011) Biochem Med (Zagreb) , vol.21 , pp. 79-85
    • Koseoglu, M.1    Hur, A.2    Atay, A.3    Cuhadar, S.4
  • 10
    • 84881069749 scopus 로고    scopus 로고
    • Cyclodextrin removal of lipemic interference: an attractive alternative to ultracentrifugation for satellite laboratories
    • Roberts C.M., Cotten S.W. Cyclodextrin removal of lipemic interference: an attractive alternative to ultracentrifugation for satellite laboratories. Arch Pathol Lab Med 2013, 137:1027-1028.
    • (2013) Arch Pathol Lab Med , vol.137 , pp. 1027-1028
    • Roberts, C.M.1    Cotten, S.W.2
  • 11
    • 84884523269 scopus 로고    scopus 로고
    • Laboratory samples deemed 'unsuitable for analysis' can be diagnostically useful
    • Sen Gupta P., Sharma M., Timms P.M. Laboratory samples deemed 'unsuitable for analysis' can be diagnostically useful. Clin Med 2013, 13:309-311.
    • (2013) Clin Med , vol.13 , pp. 309-311
    • Sen Gupta, P.1    Sharma, M.2    Timms, P.M.3
  • 14
    • 11144334591 scopus 로고    scopus 로고
    • Automated processing of serum indices used for interference detection by the laboratory information system
    • Vermeer H.J., Thomassen E., de Jonge N. Automated processing of serum indices used for interference detection by the laboratory information system. Clin Chem 2005, 51:244-247.
    • (2005) Clin Chem , vol.51 , pp. 244-247
    • Vermeer, H.J.1    Thomassen, E.2    de Jonge, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.