Volumn 48, Issue 2, 2011, Pages 170-175

Evaluation of the interference due to haemoglobin, bilirubin and lipids on Immulite 2500 assays: A practical approach

Author keywords

[No Author keywords available]

Indexed keywords

BILIRUBIN; ESTRADIOL; FERRITIN; FOLIC ACID; HEMOGLOBIN; LIPID; TESTOSTERONE;

EID: 79953004924     PISSN: 00045632     EISSN: 00045632     Source Type: Journal    
DOI: 10.1258/acb.2010.010187     Document Type: Article
Times cited : (25)

References (14)
  • 1
    • 0030857166 scopus 로고    scopus 로고
    • Errors, mistakes, blunders, outliers or unacceptable results: How many?
    • Witte DL, VanNess SA, Angstadt DS, Pennell BJ. Errors, mistakes, blunders, outliers or unacceptable results: how many? Clin Chem 1997;43:1352-6
    • (1997) Clin Chem , vol.43 , pp. 1352-1356
    • Witte, D.L.1    VanNess, S.A.2    Angstadt, D.S.3    Pennell, B.J.4
  • 2
    • 68149089064 scopus 로고    scopus 로고
    • Interference testing
    • Dimeski G. Interference testing. Clin Biochem Rev 2008;29:43-8
    • (2008) Clin Biochem Rev , vol.29 , pp. 43-48
    • Dimeski, G.1
  • 3
    • 25144458776 scopus 로고    scopus 로고
    • Interferences in immunoassay
    • Tate J, Ward G. Interferences in immunoassay. Clin Biochem Rev 2005;25:105-20
    • (2005) Clin Biochem Rev , vol.25 , pp. 105-120
    • Tate, J.1    Ward, G.2
  • 4
    • 0033885801 scopus 로고    scopus 로고
    • Interferences in immunoassay - Still a threat
    • Kricka LJ. Interferences in immunoassay - still a threat. Clin Chem 2000;46:1037-8 (Pubitemid 30643301)
    • (2000) Clinical Chemistry , vol.46 , Issue.8 I , pp. 1037-1038
    • Kricka, L.J.1
  • 5
    • 0037934622 scopus 로고    scopus 로고
    • Screening for interference in immunoassays
    • DOI 10.1373/49.7.1163
    • Emerson JF, Ngo G, Emerson SS. Screening for interference in immunoassays. Clin Chem 2003;49:1163-9 (Pubitemid 36751104)
    • (2003) Clinical Chemistry , vol.49 , Issue.7 , pp. 1163-1169
    • Emerson, J.F.1    Ngo, G.2    Emerson, S.S.3
  • 7
    • 33846528579 scopus 로고    scopus 로고
    • Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: A practical approach
    • DOI 10.1515/CCLM.2007.004
    • Vermeer HJ, Steen G, Naus AJM, Goevaerts B, Agricola PT, Schoenmakers CHH. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach. Clin Chem Lab Med 2007;45:114-9 (Pubitemid 46155573)
    • (2007) Clinical Chemistry and Laboratory Medicine , vol.45 , Issue.1 , pp. 114-119
    • Vermeer, H.J.1    Steen, G.2    Naus, A.J.M.3    Goevaerts, B.4    Agricola, P.T.5    Schoenmakers, C.H.H.6
  • 8
    • 0022885477 scopus 로고
    • Graphical comparisons of interferences in clinical chemistry instrumentation
    • Glick MR, Ryder WR, Jackson SA. Graphical comparisons of interferences in clinical chemistry instrumentation. Clin Chem 1986;32:470-5 (Pubitemid 17016962)
    • (1986) Clinical Chemistry , vol.32 , Issue.3 , pp. 470-475
    • Glick, M.R.1    Ryder, K.W.2    Jackson, S.A.3
  • 9
    • 0001068517 scopus 로고
    • Protocol for the validation of methods. Document B, stage 3. Commission for validation of methods of the Société Francaise de Biologie Clinique
    • Vassault A, Grafmeyer D, Naudin C, et al. Protocol for the validation of methods. Document B, stage 3. Commission for validation of methods of the Société Francaise de Biologie Clinique. Ann Biol Clin 1986;44:686-745
    • (1986) Ann Biol Clin , vol.44 , pp. 686-745
    • Vassault, A.1    Grafmeyer, D.2    Naudin, C.3
  • 10
    • 0030160313 scopus 로고    scopus 로고
    • Bilirubin interference of creatinine, lactate, phosphorus and uric acid on BC Synchron CX7
    • Beyne P, Letteron P, Herve C, Roullet JB, Delacoux E. Bilirubin interference of creatinine, lactate, phosphorus and uric acid on BC Synchron CX7. Clin Chem 1996;42:988-90
    • (1996) Clin Chem , vol.42 , pp. 988-990
    • Beyne, P.1    Letteron, P.2    Herve, C.3    Roullet, J.B.4    Delacoux, E.5
  • 11
    • 7044241205 scopus 로고    scopus 로고
    • Evaluating interference caused by lipemia
    • DOI 10.1373/clinchem.2004.038075
    • Kroll MH. Evaluating interference caused by lipemia. Clin Chem 2004;50:1968-9 (Pubitemid 39425829)
    • (2004) Clinical Chemistry , vol.50 , Issue.11 , pp. 1968-1969
    • Kroll, M.H.1
  • 12
    • 7044260841 scopus 로고    scopus 로고
    • Assay-specific differences in lipemic interference in native and Intralipid-supplemented samples
    • Bornhorst JA, Roberts RF, Roberts WL. Assay-specific differences in lipemic interference in native and Intralipid-supplemented samples. Clin Chem 2004;50:2197-200
    • (2004) Clin Chem , vol.50 , pp. 2197-2200
    • Bornhorst, J.A.1    Roberts, R.F.2    Roberts, W.L.3
  • 13
    • 3242702506 scopus 로고    scopus 로고
    • Test result variation and the quality of evidence-based clinical guidelines
    • DOI 10.1016/j.cccn.2003.12.032, PII S0009898104001615
    • Fraser CG. Test result variation and the quality of evidence-based clinical guidelines. Clin Chim Acta 2004;346:19-24 (Pubitemid 38952686)
    • (2004) Clinica Chimica Acta , vol.346 , Issue.1 , pp. 19-24
    • Fraser, C.G.1
  • 14
    • 0033369894 scopus 로고    scopus 로고
    • Current databases on biologic variation: Pros, cons and progress
    • See last checked 26 January 2011
    • Ricos C, Alvarez V, Cava F, et al. Current databases on biologic variation: pros, cons and progress. Scand J Clin Lab Invest 1999;59:491-500. See www.westgard.com/biodatabase1.htm (last checked 26 January 2011)
    • (1999) Scand J Clin Lab Invest , vol.59 , pp. 491-500
    • Ricos, C.1    Alvarez, V.2    Cava, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.