메뉴 건너뛰기




Volumn 8673 LNCS, Issue PART 1, 2014, Pages 218-226

DR-BUDDI: Diffeomorphic registration for blip up-down diffusion imaging

Author keywords

[No Author keywords available]

Indexed keywords

DIFFUSION; MAGNETIC RESONANCE IMAGING; MEDICAL COMPUTING;

EID: 84906978503     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-319-10404-1_28     Document Type: Conference Paper
Times cited : (9)

References (12)
  • 1
    • 0142074685 scopus 로고    scopus 로고
    • How to correct susceptibility distortions in spinecho echo-planar images: Application to diffusion tensor imaging
    • Andersson, J.L., Skare, S., Ashburner, J.: How to correct susceptibility distortions in spinecho echo-planar images: application to diffusion tensor imaging. NeuroImage 20(2), 870-888 (2003)
    • (2003) NeuroImage , vol.20 , Issue.2 , pp. 870-888
    • Andersson, J.L.1    Skare, S.2    Ashburner, J.3
  • 2
    • 38849187993 scopus 로고    scopus 로고
    • Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain
    • Avants, B., Epstein, C., Grossman, M., Gee, J.: Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain. Medical Image Analysis 12(1), 26-41 (2008)
    • (2008) Medical Image Analysis , vol.12 , Issue.1 , pp. 26-41
    • Avants, B.1    Epstein, C.2    Grossman, M.3    Gee, J.4
  • 3
    • 78650181934 scopus 로고    scopus 로고
    • A reproducible evaluation of ANTs similarity metric performance in brain image registration
    • Avants, B., Tustison, N.J., Song, G., Cook, P.A., Klein, A., Gee, J.C.: A reproducible evaluation of ANTs similarity metric performance in brain image registration. NeuroImage 54(3), 2033-2044 (2011)
    • (2011) NeuroImage , vol.54 , Issue.3 , pp. 2033-2044
    • Avants, B.1    Tustison, N.J.2    Song, G.3    Cook, P.A.4    Klein, A.5    Gee, J.C.6
  • 5
    • 0026925939 scopus 로고
    • A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
    • Chang, H., Fitzpatrick, J.M.: A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. IEEE TMI 11(3), 319-329 (1992)
    • (1992) IEEE TMI , vol.11 , Issue.3 , pp. 319-329
    • Chang, H.1    Fitzpatrick, J.M.2
  • 6
    • 75349084742 scopus 로고    scopus 로고
    • Efficient correction of inhomogeneous static magnetic field-induced distortion in echo planar imaging
    • Holland, D., Kuperman, J.M., Dale, A.M.: Efficient correction of inhomogeneous static magnetic field-induced distortion in echo planar imaging. Neuroimage 50, 175-183 (2010)
    • (2010) Neuroimage , vol.50 , pp. 175-183
    • Holland, D.1    Kuperman, J.M.2    Dale, A.M.3
  • 7
    • 84859091395 scopus 로고    scopus 로고
    • Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results
    • Irfanoglu, M.O.,Walker, L., Sarlls, J., Marenco, S., Pierpaoli, C.: Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results. Neuroimage 15(61), 275-288 (2012)
    • (2012) Neuroimage , vol.15 , Issue.61 , pp. 275-288
    • Irfanoglu, M.O.1    Walker, L.2    Sarlls, J.3    Marenco, S.4    Pierpaoli, C.5
  • 8
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from B0 field variations
    • Jezzard, P., Balban, R.: Correction for geometric distortion in echo planar images from B0 field variations. Magnetic Resonance in Medicine 34, 65-73 (1995)
    • (1995) Magnetic Resonance in Medicine , vol.34 , pp. 65-73
    • Jezzard, P.1    Balban, R.2
  • 11
    • 17144426986 scopus 로고    scopus 로고
    • Vector-valued image regularization with PDEs: A common framework for different applications
    • Tschumperlé, D., Deriche, R.: Vector-valued image regularization with PDEs: A common framework for different applications. IEEE Trans. PAMI 27(4), 506-517 (2005)
    • (2005) IEEE Trans. PAMI , vol.27 , Issue.4 , pp. 506-517
    • Tschumperlé, D.1    Deriche, R.2
  • 12
    • 79551688044 scopus 로고    scopus 로고
    • Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework
    • Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part II. Springer, Heidelberg
    • Wu, M., Chang, L.-C., Walker, L., Lemaitre, H., Barnett, A.S., Marenco, S., Pierpaoli, C.: Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework. In: Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part II. LNCS, vol. 5242, pp. 321-329. Springer, Heidelberg (2008)
    • (2008) LNCS , vol.5242 , pp. 321-329
    • Wu, M.1    Chang, L.-C.2    Walker, L.3    Lemaitre, H.4    Barnett, A.S.5    Marenco, S.6    Pierpaoli, C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.