메뉴 건너뛰기




Volumn 84, Issue 3, 2014, Pages 377-385

Diagnostic accuracy of intravascular ultrasound-derived minimal lumen area compared with fractional flow reserve - Meta-analysis: Pooled accuracy of IVUS luminal area versus FFR

Author keywords

coronary artery disease; fractional flow reserve; intravascular ultrasound; percutaneous coronary intervention

Indexed keywords

ADULT; AREA UNDER THE CURVE; ARTICLE; CLINICAL DECISION MAKING; CONTROLLED STUDY; CORONARY ARTERY DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DISEASE SEVERITY; FEMALE; FRACTIONAL FLOW RESERVE; FUNCTIONAL ASSESSMENT; HUMAN; INTERMETHOD COMPARISON; INTRAVASCULAR ULTRASOUND; MAJOR CLINICAL STUDY; MALE; META ANALYSIS; MIDDLE AGED; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW; CORONARY BLOOD VESSEL; ECHOGRAPHY; ENDOSCOPIC ECHOGRAPHY; PATHOPHYSIOLOGY; PROCEDURES; PROGNOSIS; REPRODUCIBILITY; SEVERITY OF ILLNESS INDEX;

EID: 84906355925     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.25047     Document Type: Article
Times cited : (45)

References (39)
  • 1
    • 77955066802 scopus 로고    scopus 로고
    • Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME (Fractional flow reserve versus Angiography for Multivessel Evaluation) study
    • Pijls NH, Fearon WF, Tonino PA, Siebert U, Ikeno F, et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME (Fractional flow reserve versus Angiography for Multivessel Evaluation) study. J Am Coll Cardiol 2010; 56: 177-184.
    • (2010) J Am Coll Cardiol , vol.56 , pp. 177-184
    • Pijls, N.H.1    Fearon, W.F.2    Tonino, P.A.3    Siebert, U.4    Ikeno, F.5
  • 2
    • 34248634284 scopus 로고    scopus 로고
    • Percutaneous coronary intervention of functionally nonsignificant stenosis: 5-year follow-up of the DEFER Study
    • Pijls NH, van Schaardenburgh P, Manoharan G, Boersma E, Bech JW, et al. Percutaneous coronary intervention of functionally nonsignificant stenosis: 5-year follow-up of the DEFER Study. J Am Coll Cardiol 2007; 49: 2105-2111.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 2105-2111
    • Pijls, N.H.1    Van Schaardenburgh, P.2    Manoharan, G.3    Boersma, E.4    Bech, J.W.5
  • 3
    • 0028329934 scopus 로고
    • Impact of preintervention intravascular ultrasound imaging on transcatheter treatment strategies in coronary artery disease
    • Mintz GS, Pichard AD, Kovach JA, Kent KM, Satler LF, Javier SP, Popma JJ, Leon MB,. Impact of preintervention intravascular ultrasound imaging on transcatheter treatment strategies in coronary artery disease. Am J Cardiol 1994; 73: 423-430.
    • (1994) Am J Cardiol , vol.73 , pp. 423-430
    • Mintz, G.S.1    Pichard, A.D.2    Kovach, J.A.3    Kent, K.M.4    Satler, L.F.5    Javier, S.P.6    Popma, J.J.7    Leon, M.B.8
  • 5
    • 0031870569 scopus 로고    scopus 로고
    • Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty
    • Abizaid A, Mintz GS, Pichard AD, Kent KM, Satler LF, Walsh CL, Popma JJ, Leon MB,. Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty. Am J Cardiol 1998; 82: 423-428.
    • (1998) Am J Cardiol , vol.82 , pp. 423-428
    • Abizaid, A.1    Mintz, G.S.2    Pichard, A.D.3    Kent, K.M.4    Satler, L.F.5    Walsh, C.L.6    Popma, J.J.7    Leon, M.B.8
  • 6
    • 0033587505 scopus 로고    scopus 로고
    • Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: Importance of lumen dimensions
    • Abizaid AS, Mintz GS, Mehran R, Abizaid A, Lansky AJ, et al. Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: Importance of lumen dimensions. Circulation 1999; 100: 256-261.
    • (1999) Circulation , vol.100 , pp. 256-261
    • Abizaid, A.S.1    Mintz, G.S.2    Mehran, R.3    Abizaid, A.4    Lansky, A.J.5
  • 8
    • 0033587638 scopus 로고    scopus 로고
    • Clinical potential of intravascular ultrasound for physiological assessment of coronary stenosis: Relationship between quantitative ultrasound tomography and pressure-derived fractional flow reserve
    • Takagi A, Tsurumi Y, Ishii Y, Suzuki K, Kawana M, Kasanuki H,. Clinical potential of intravascular ultrasound for physiological assessment of coronary stenosis: Relationship between quantitative ultrasound tomography and pressure-derived fractional flow reserve. Circulation 1999; 100: 250-255.
    • (1999) Circulation , vol.100 , pp. 250-255
    • Takagi, A.1    Tsurumi, Y.2    Ishii, Y.3    Suzuki, K.4    Kawana, M.5    Kasanuki, H.6
  • 9
    • 33847023913 scopus 로고    scopus 로고
    • Assessment of intermediate severity coronary lesions in the catheterization laboratory
    • Tobis J, Azarbal B, Slavin L,. Assessment of intermediate severity coronary lesions in the catheterization laboratory. J Am Coll Cardiol 2007; 49: 839-848.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 839-848
    • Tobis, J.1    Azarbal, B.2    Slavin, L.3
  • 12
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J,. The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 2003; 3: 25.
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3    Bossuyt, P.M.4    Kleijnen, J.5
  • 14
    • 0032580320 scopus 로고    scopus 로고
    • Two-sided confidence intervals for the single proportion: Comparison of seven methods
    • Newcombe RG,. Two-sided confidence intervals for the single proportion: Comparison of seven methods. Stat Med 1998; 17: 857-872.
    • (1998) Stat Med , vol.17 , pp. 857-872
    • Newcombe, R.G.1
  • 16
    • 0037093923 scopus 로고    scopus 로고
    • Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
    • Walter SD,. Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data. Stat Med 2002; 21: 1237-1256.
    • (2002) Stat Med , vol.21 , pp. 1237-1256
    • Walter, S.D.1
  • 17
    • 0027290944 scopus 로고
    • Combining independent studies of a diagnostic test into a summary ROC curve: Data-analytic approaches and some additional considerations
    • Moses LE, Shapiro D, Littenberg B,. Combining independent studies of a diagnostic test into a summary ROC curve: Data-analytic approaches and some additional considerations. Stat Med 1993; 12: 1293-1316.
    • (1993) Stat Med , vol.12 , pp. 1293-1316
    • Moses, L.E.1    Shapiro, D.2    Littenberg, B.3
  • 18
    • 65949108374 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of diagnostic and prognostic studies: A tutorial
    • Sousa MR, Ribeiro AL,. Systematic review and meta-analysis of diagnostic and prognostic studies: A tutorial. Arq Bras Cardiol 2009; 92: 229-238.
    • (2009) Arq Bras Cardiol , vol.92 , pp. 229-238
    • Sousa, M.R.1    Ribeiro, A.L.2
  • 19
    • 85045417272 scopus 로고    scopus 로고
    • A methodological review of how heterogeneity has been examined in systematic reviews of diagnostic test accuracy
    • Dinnes J, Deeks J, Kirby J, Roderick P,. A methodological review of how heterogeneity has been examined in systematic reviews of diagnostic test accuracy. Health Technol Assess (Winchester, England) 2005; 9: 1-113.
    • (2005) Health Technol Assess (Winchester, England) , vol.9 , pp. 1-113
    • Dinnes, J.1    Deeks, J.2    Kirby, J.3    Roderick, P.4
  • 20
    • 0037098147 scopus 로고    scopus 로고
    • Exploring sources of heterogeneity in systematic reviews of diagnostic tests
    • Lijmer JG, Bossuyt PM, Heisterkamp SH,. Exploring sources of heterogeneity in systematic reviews of diagnostic tests. Stat Med 2002; 21: 1525-1537.
    • (2002) Stat Med , vol.21 , pp. 1525-1537
    • Lijmer, J.G.1    Bossuyt, P.M.2    Heisterkamp, S.H.3
  • 21
    • 84861662892 scopus 로고    scopus 로고
    • Intravascular ultrasound lumen area parameters for assessment of physiological ischemia by fractional flow reserve in intermediate coronary artery stenosis
    • Ben-Dor I, Torguson R, Deksissa T, Xue Z, Satler LF, Pichard AD, Waksman R,. Intravascular ultrasound lumen area parameters for assessment of physiological ischemia by fractional flow reserve in intermediate coronary artery stenosis. Cardiovasc Revasc Med 2012; 13: 177-182.
    • (2012) Cardiovasc Revasc Med , vol.13 , pp. 177-182
    • Ben-Dor, I.1    Torguson, R.2    Deksissa, T.3    Xue, Z.4    Satler, L.F.5    Pichard, A.D.6    Waksman, R.7
  • 22
    • 84858213836 scopus 로고    scopus 로고
    • Morphometric assessment of coronary stenosis relevance with optical coherence tomography: A comparison with fractional flow reserve and intravascular ultrasound
    • Gonzalo N, Escaned J, Alfonso F, Nolte C, Rodriguez V, et al. Morphometric assessment of coronary stenosis relevance with optical coherence tomography: A comparison with fractional flow reserve and intravascular ultrasound. J Am Coll Cardiol 2012; 59: 1080-1089.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1080-1089
    • Gonzalo, N.1    Escaned, J.2    Alfonso, F.3    Nolte, C.4    Rodriguez, V.5
  • 23
    • 80054054556 scopus 로고    scopus 로고
    • Correlation between fractional flow reserve and intravascular ultrasound lumen area in intermediate coronary artery stenosis
    • Ben-Dor I, Torguson R, Gaglia MA Jr, Gonzalez MA, Maluenda G, et al. Correlation between fractional flow reserve and intravascular ultrasound lumen area in intermediate coronary artery stenosis. EuroIntervention 2011; 7: 225-233.
    • (2011) EuroIntervention , vol.7 , pp. 225-233
    • Ben-Dor, I.1    Torguson, R.2    Gaglia, Jr.M.A.3    Gonzalez, M.A.4    Maluenda, G.5
  • 24
    • 84862788067 scopus 로고    scopus 로고
    • Usefulness of minimal luminal coronary area determined by intravascular ultrasound to predict functional significance in stable and unstable angina pectoris
    • Kang SJ, Ahn JM, Song H, Kim WJ, Lee JY, et al. Usefulness of minimal luminal coronary area determined by intravascular ultrasound to predict functional significance in stable and unstable angina pectoris. Am J Cardiol 2012; 109: 947-953.
    • (2012) Am J Cardiol , vol.109 , pp. 947-953
    • Kang, S.J.1    Ahn, J.M.2    Song, H.3    Kim, W.J.4    Lee, J.Y.5
  • 25
    • 79954448263 scopus 로고    scopus 로고
    • Validation of intravascular ultrasound-derived parameters with fractional flow reserve for assessment of coronary stenosis severity
    • Kang SJ, Lee JY, Ahn JM, Mintz GS, Kim WJ, et al. Validation of intravascular ultrasound-derived parameters with fractional flow reserve for assessment of coronary stenosis severity. Circ Cardiovasc Interv 2011; 4: 65-71.
    • (2011) Circ Cardiovasc Interv , vol.4 , pp. 65-71
    • Kang, S.J.1    Lee, J.Y.2    Ahn, J.M.3    Mintz, G.S.4    Kim, W.J.5
  • 26
    • 81855174799 scopus 로고    scopus 로고
    • Intravascular ultrasound-derived predictors for fractional flow reserve in intermediate left main disease
    • Kang SJ, Lee JY, Ahn JM, Song HG, Kim WJ, et al. Intravascular ultrasound-derived predictors for fractional flow reserve in intermediate left main disease. JACC Cardiovasc Interv 2011; 4: 1168-1174.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 1168-1174
    • Kang, S.J.1    Lee, J.Y.2    Ahn, J.M.3    Song, H.G.4    Kim, W.J.5
  • 27
    • 0035863608 scopus 로고    scopus 로고
    • Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve
    • Briguori C, Anzuini A, Airoldi F, Gimelli G, Nishida T, Adamian M, Corvaja N, Di Mario C, Colombo A,. Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve. Am J Cardiol 2001; 87: 136-141.
    • (2001) Am J Cardiol , vol.87 , pp. 136-141
    • Briguori, C.1    Anzuini, A.2    Airoldi, F.3    Gimelli, G.4    Nishida, T.5    Adamian, M.6    Corvaja, N.7    Di Mario, C.8    Colombo, A.9
  • 28
    • 8144226851 scopus 로고    scopus 로고
    • Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis
    • Jasti V, Ivan E, Yalamanchili V, Wongpraparut N, Leesar MA,. Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis. Circulation 2004; 110: 2831-2836.
    • (2004) Circulation , vol.110 , pp. 2831-2836
    • Jasti, V.1    Ivan, E.2    Yalamanchili, V.3    Wongpraparut, N.4    Leesar, M.A.5
  • 29
    • 79960592030 scopus 로고    scopus 로고
    • Optimal intravascular ultrasound criteria and their accuracy for defining the functional significance of intermediate coronary stenoses of different locations
    • Koo BK, Yang HM, Doh JH, Choe H, Lee SY, et al. Optimal intravascular ultrasound criteria and their accuracy for defining the functional significance of intermediate coronary stenoses of different locations. JACC Cardiovasc Interv 2011; 4: 803-811.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 803-811
    • Koo, B.K.1    Yang, H.M.2    Doh, J.H.3    Choe, H.4    Lee, S.Y.5
  • 30
    • 77951666959 scopus 로고    scopus 로고
    • New set of intravascular ultrasound-derived anatomic criteria for defining functionally significant stenoses in small coronary arteries (results from Intravascular Ultrasound Diagnostic Evaluation of Atherosclerosis in Singapore [IDEAS] study)
    • Lee CH, Tai BC, Soon CY, Low AF, Poh KK, et al. New set of intravascular ultrasound-derived anatomic criteria for defining functionally significant stenoses in small coronary arteries (results from Intravascular Ultrasound Diagnostic Evaluation of Atherosclerosis in Singapore [IDEAS] study). Am J Cardiol 2010; 105: 1378-1384.
    • (2010) Am J Cardiol , vol.105 , pp. 1378-1384
    • Lee, C.H.1    Tai, B.C.2    Soon, C.Y.3    Low, A.F.4    Poh, K.K.5
  • 31
    • 3342879089 scopus 로고    scopus 로고
    • Reporting of measures of accuracy in systematic reviews of diagnostic literature
    • Honest H, Khan KS,. Reporting of measures of accuracy in systematic reviews of diagnostic literature. BMC Health Serv Res 2002; 2: 4.
    • (2002) BMC Health Serv Res , vol.2 , pp. 4
    • Honest, H.1    Khan, K.S.2
  • 32
    • 46249116267 scopus 로고    scopus 로고
    • Fractional flow reserve: A review: Invasive imaging
    • De Bruyne B, Sarma J,. Fractional flow reserve: A review: Invasive imaging. Heart 2008; 94: 949-959.
    • (2008) Heart , vol.94 , pp. 949-959
    • De Bruyne, B.1    Sarma, J.2
  • 33
    • 78649656819 scopus 로고    scopus 로고
    • Practical tips and tricks for the measurement of fractional flow reserve
    • Sharif F, Trana C, Muller O, De Bruyne B,. Practical tips and tricks for the measurement of fractional flow reserve. Catheter Cardiovasc Interv 2010; 76: 978-985.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 978-985
    • Sharif, F.1    Trana, C.2    Muller, O.3    De Bruyne, B.4
  • 34
    • 67049125693 scopus 로고    scopus 로고
    • Comparison of the intracoronary continuous infusion method using a microcatheter and the intravenous continuous adenosine infusion method for inducing maximal hyperemia for fractional flow reserve measurement
    • Yoon MH, Tahk SJ, Yang HM, Park JS, Zheng M, et al. Comparison of the intracoronary continuous infusion method using a microcatheter and the intravenous continuous adenosine infusion method for inducing maximal hyperemia for fractional flow reserve measurement. Am Heart J 2009; 157: 1050-1056.
    • (2009) Am Heart J , vol.157 , pp. 1050-1056
    • Yoon, M.H.1    Tahk, S.J.2    Yang, H.M.3    Park, J.S.4    Zheng, M.5
  • 35
    • 84906350853 scopus 로고    scopus 로고
    • Evaluation of diagnostic and screening tests
    • Egger M. editor. London: BMJ Publishing Group;
    • Egger M,. Evaluation of diagnostic and screening tests. In:, Egger M, editor. Systematic Reviews in Health Care, Vol. 1. London: BMJ Publishing Group; 2001. pp. 269-283.
    • (2001) Systematic Reviews in Health Care , vol.1 , pp. 269-283
    • Egger, M.1
  • 36
    • 0032521496 scopus 로고    scopus 로고
    • Long-term follow-up after deferral of percutaneous transluminal coronary angioplasty of intermediate stenosis on the basis of coronary pressure measurement
    • Bech GJ, De Bruyne B, Bonnier HJ, Bartunek J, Wijns W, Peels K, Heyndrickx GR, Koolen JJ, Pijls NH,. Long-term follow-up after deferral of percutaneous transluminal coronary angioplasty of intermediate stenosis on the basis of coronary pressure measurement. J Am Coll Cardiol 1998; 31: 841-847.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 841-847
    • Bech, G.J.1    De Bruyne, B.2    Bonnier, H.J.3    Bartunek, J.4    Wijns, W.5    Peels, K.6    Heyndrickx, G.R.7    Koolen, J.J.8    Pijls, N.H.9
  • 37
    • 0035912957 scopus 로고    scopus 로고
    • Fractional flow reserve to determine the appropriateness of angioplasty in moderate coronary stenosis: A randomized trial
    • Bech GJ, De Bruyne B, Pijls NH, de Muinck ED, et al. Fractional flow reserve to determine the appropriateness of angioplasty in moderate coronary stenosis: A randomized trial. Circulation 2001; 103: 2928-2934.
    • (2001) Circulation , vol.103 , pp. 2928-2934
    • Bech, G.J.1    De Bruyne, B.2    Pijls, N.H.3    De Muinck, E.D.4
  • 38
    • 58349112528 scopus 로고    scopus 로고
    • Fractional flow reserve versus angiography for guiding percutaneous coronary intervention
    • Tonino PA, De Bruyne B, Pijls NH, Siebert U, Ikeno F, et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med 2009; 360: 213-224.
    • (2009) N Engl J Med , vol.360 , pp. 213-224
    • Tonino, P.A.1    De Bruyne, B.2    Pijls, N.H.3    Siebert, U.4    Ikeno, F.5
  • 39
    • 73549104615 scopus 로고    scopus 로고
    • Current concepts of integrated coronary physiology in the catheterization laboratory
    • Kern MJ, Samady H,. Current concepts of integrated coronary physiology in the catheterization laboratory. J Am Coll Cardiol 2010; 55: 173-185.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 173-185
    • Kern, M.J.1    Samady, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.