-
1
-
-
84883089951
-
Effects of increased image noise on image quality and quantitative interpretation in brain CT perfusion
-
Juluru K, Shih JC, Raj A et al (2013) Effects of increased image noise on image quality and quantitative interpretation in brain CT perfusion. AJNR Am J Neuroradiol 34:1506-1512
-
(2013)
AJNR Am J Neuroradiol
, vol.34
, pp. 1506-1512
-
-
Juluru, K.1
Shih, J.C.2
Raj, A.3
-
2
-
-
0035137614
-
Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT
-
Koenig M, Kraus M, Theek C, Klotz E, Gehlen W, Heuser L (2001) Quantitative assessment of the ischemic brain by means of perfusion related parameters derived from perfusion CT. Stroke 32:431-437 (Pubitemid 32155230)
-
(2001)
Stroke
, vol.32
, Issue.2
, pp. 431-437
-
-
Koenig, M.1
Kraus, M.2
Theek, C.3
Klotz, E.4
Gehlen, W.5
Heuser, L.6
-
3
-
-
0036200242
-
Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients
-
DOI 10.1002/ana.10136
-
Wintermark M, Reichhart M, Thiran JP et al (2002) Prognostic accuracy of cerebral blood flow measurements by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients. Ann Neurol 51:417-432 (Pubitemid 34260772)
-
(2002)
Annals of Neurology
, vol.51
, Issue.4
, pp. 417-432
-
-
Wintermark, M.1
Reichhart, M.2
Thiran, J.-P.3
Maeder, P.4
Chalaron, M.5
Schnyder, P.6
Bogousslavsky, J.7
Meuli, R.8
-
4
-
-
30744434394
-
Brain perfusion-CT in acute stroke patients
-
Wintermark M (2005) Brain perfusion-CT in acute stroke patients. Eur Radiol 15:D28-D31
-
(2005)
Eur Radiol
, vol.15
-
-
Wintermark, M.1
-
5
-
-
0036135297
-
CT perfusion scanning with deconvolution analysis: Pilot study in patients with acute middle cerebral artery stroke
-
Eastwood JD, Lev MH, Azhari T et al (2002) CT perfusion scanning with deconvolution analysis: pilot study in patients with acutemiddle cerebral artery stroke. Radiology 222:227-236 (Pubitemid 34031492)
-
(2002)
Radiology
, vol.222
, Issue.1
, pp. 227-236
-
-
Eastwood, J.D.1
Lev, M.H.2
Azhari, T.3
Lee, T.-Y.4
Barboriak, D.P.5
Delong, D.M.6
Fitzek, C.7
Herzau, M.8
Wintermark, M.9
Meuli, R.10
Brazier, D.11
Provenzale, J.M.12
-
6
-
-
0031690799
-
Perfusion CT of the brain: Diagnostic approach for early detection of ischemic stroke
-
Koenig M, Klotz E, Luka B, Venderink DJ, Spittler JF, Heuser L (1998) Perfusion CT of the brain: diagnostic approach for early detection of ischemic stroke. Radiology 209:85-93 (Pubitemid 28464652)
-
(1998)
Radiology
, vol.209
, Issue.1
, pp. 85-93
-
-
Koenig, M.1
Klotz, E.2
Luka, B.3
Venderink, D.J.4
Spittler, J.F.5
Heuser, L.6
-
7
-
-
0034918310
-
Reproducibility of quantitative CT perfusion imaging
-
Gillard JH, Antoun NM, Burnet NG, Pickard JD (2001) Reproducibility of quantitative CT perfusion imaging. Br J Radiol 74:552-555 (Pubitemid 32674216)
-
(2001)
British Journal of Radiology
, vol.74
, Issue.882
, pp. 552-555
-
-
Gillard, J.H.1
Antoun, N.M.2
Burnet, N.G.3
Pickard, J.D.4
-
8
-
-
84886507045
-
Estimation of radiation exposure for brain perfusion CT: Standard protocol compared with deviations in protocol
-
Hoang JK, Wang C, Frush DP et al (2013) Estimation of radiation exposure for brain perfusion CT: standard protocol compared with deviations in protocol. AJR Am J Roentgenol 201:W730-W734
-
(2013)
AJR Am J Roentgenol
, vol.201
-
-
Hoang, J.K.1
Wang, C.2
Frush, D.P.3
-
9
-
-
84886465395
-
-
website. Accessed 5 July 2013
-
United States Food and Drug Administration website. Safety investigation of CT brain perfusion scans: update 11/9/2010. www.fda.gov/ medicaldevicesmedicaldevices/safety/alertsandnotices/ucm185898.htm. Accessed 5 July 2013
-
Safety Investigation of CT Brain Perfusion Scans: Update 11/9/2010
-
-
-
10
-
-
36549007486
-
Computed tomography - An increasing source of radiation exposure
-
DOI 10.1056/NEJMra072149
-
Brenner DJ, Hall EJ (2007) Computed tomography-an increasing source of radiation exposure. N Engl J Med 357:2277-2284 (Pubitemid 350190758)
-
(2007)
New England Journal of Medicine
, vol.357
, Issue.22
, pp. 2277-2284
-
-
Brenner, D.J.1
Hall, E.J.2
-
11
-
-
84893230668
-
Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
-
Niesten JM, van der Schaaf IC, Riordan AJ et al (2014) Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction. Eur Radiol 24:484-493
-
(2014)
Eur Radiol
, vol.24
, pp. 484-493
-
-
Niesten, J.M.1
Van Der Schaaf, I.C.2
Riordan, A.J.3
-
12
-
-
84886478188
-
-
website Accessed 5 July 2013
-
American Association of Physicists in Medicine website (2012) Adult brain perfusion CT protocols version 1.1. www.aapm.org/pubs/CTProtocols/documents/ Adult/Brain/PerfusionCT.pdf. Accessed 5 July 2013
-
(2012)
Adult Brain Perfusion CT Protocols Version 1.1
-
-
-
13
-
-
33846043899
-
Image quality in CT perfusion imaging of the brain
-
DOI 10.1007/s00330-006-0277-3
-
König M, Bültmann E, Bode-Schnurbus L, Koenen D, Mielke E, Heuser L (2007) Image quality in CT perfusion imaging of the brain. The role of iodine concentration. Eur Radiol 17:39-47 (Pubitemid 46063027)
-
(2007)
European Radiology
, vol.17
, Issue.1
, pp. 39-47
-
-
Konig, M.1
Bultmann, E.2
Bode-Schnurbus, L.3
Koenen, D.4
Mielke, E.5
Heuser, L.6
-
14
-
-
84905579960
-
70 kV computed tomography of the thorax: Valence for computer-assisted nodule evaluation and radiation dose - First clinical results
-
Bodelle B, Klement D, Kerl JM et al (2013) 70 kV computed tomography of the thorax: valence for computer-assisted nodule evaluation and radiation dose - first clinical results. Acta Radiol 22
-
(2013)
Acta Radiol
, pp. 22
-
-
Bodelle, B.1
Klement, D.2
Kerl, J.M.3
-
15
-
-
0034879677
-
Quantitative assessment of regional cerebral blood flows by perfusion CT studies at low injection rates: A critical review of the underlying theoretical models
-
DOI 10.1007/s003300000707
-
Wintermark M, Maeder P, Thiran JP et al (2001) Quantitative assessment of regional cerebral blood flows by perfusion CT studies at low injection rates: a critical review of the underlying theoretical models. Eur Radiol 11:1220-1230 (Pubitemid 32755601)
-
(2001)
European Radiology
, vol.11
, Issue.7
, pp. 1220-1230
-
-
Wintermark, M.1
Maeder, P.2
Thiran, J.-P.3
Schnyder, P.4
Meuli, R.5
-
16
-
-
51649104351
-
Quantitative cerebrovascular reserve measured by acetazolamide-challenged dynamic ct perfusion in ischemic adult Moyamoya disease: Initial experience with angiographic correlation
-
Kang KH, Kim HS, Kim SY (2008) Quantitative cerebrovascular reserve measured by acetazolamide-challenged dynamic ct perfusion in ischemic adult Moyamoya disease: initial experience with angiographic correlation. AJNR Am J Neuroradiol 29:1487 - 1493
-
(2008)
AJNR Am J Neuroradiol
, vol.29
, pp. 1487-1493
-
-
Kang, K.H.1
Kim, H.S.2
Kim, S.Y.3
-
17
-
-
0020659564
-
Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique
-
Axel L (1983) Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. Investig Radiol 8:94-99
-
(1983)
Investig Radiol
, vol.8
, pp. 94-99
-
-
Axel, L.1
-
18
-
-
84455188649
-
Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kV acquisition
-
Tawfik AM, Kerl JM, Razek AA et al (2011) Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kV acquisition. AJNR Am J Neuroradiol 32:1994-1999
-
(2011)
AJNR Am J Neuroradiol
, vol.32
, pp. 1994-1999
-
-
Tawfik, A.M.1
Kerl, J.M.2
Razek, A.A.3
-
19
-
-
0033730930
-
Using 80 kV versus 120 kV in perfusion CT measurement of regional cerebral blood flow
-
Wintermark M, Maeder P, Verdun FR et al (2000) Using 80 kV versus 120 kV in perfusion CT measurement of regional cerebral blood flow. AJNR Am J Neuroradiol 21:1881-1884
-
(2000)
AJNR Am J Neuroradiol
, vol.21
, pp. 1881-1884
-
-
Wintermark, M.1
Maeder, P.2
Verdun, F.R.3
-
21
-
-
0000929507
-
Increase of contrast signal by means of low-tube voltage in CT perfusion imaging of the brain
-
Koenig M, Bueltmann E, Hering von Diepenbroick V, Koenen D, Heuser L (2001) Increase of contrast signal by means of low-tube voltage in CT perfusion imaging of the brain. Radiology 221:346
-
(2001)
Radiology
, vol.221
, pp. 346
-
-
Koenig, M.1
Bueltmann, E.2
Hering Von Diepenbroick, V.3
Koenen, D.4
Heuser, L.5
-
22
-
-
84874305360
-
Whole-brain CT perfusion and CTangiography assessment of Moyamoya disease before and after surgical revascularization: Preliminary study with 256-Slice CT
-
Zhang J, Wang J, Geng D, Li Y, Song D, Gu Y (2013) Whole-brain CT perfusion and CTangiography assessment of Moyamoya disease before and after surgical revascularization: preliminary study with 256-Slice CT. PLoS ONE 8:e57595
-
(2013)
PLoS ONE
, vol.8
-
-
Zhang, J.1
Wang, J.2
Geng, D.3
Li, Y.4
Song, D.5
Gu, Y.6
-
23
-
-
33748784121
-
Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke
-
Cohnen M, Wittsack HJ, Assadi S et al (2006) Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke. AJNR Am J Neuroradiol 27:1741-1745 (Pubitemid 44413563)
-
(2006)
American Journal of Neuroradiology
, vol.27
, Issue.8
, pp. 1741-1745
-
-
Cohnen, M.1
Wittsack, H.-J.2
Assadi, S.3
Muskalla, K.4
Ringelstein, A.5
Poll, L.W.6
Saleh, A.7
Modder, U.8
-
24
-
-
29244487400
-
CT perfusion imaging for childhood moyamoya disease before and after surgical revascularization
-
DOI 10.1007/s00701-005-0634-z
-
Sakamoto S, Ohba S, Shibukawa M, Kiura Y, Arita K, Kurisu K (2006) CT perfusion imaging for childhood moyamoya disease before and after surgical revascularization. Acta Neurochir (Wien) 148:77-81 (Pubitemid 41821464)
-
(2006)
Acta Neurochirurgica
, vol.148
, Issue.1
, pp. 77-81
-
-
Sakamoto, S.1
Ohba, S.2
Shibukawa, M.3
Kiura, Y.4
Arita, K.5
Kurisu, K.6
-
25
-
-
2442667853
-
Cerebral perfusion CT: Technique and clinical applications
-
DOI 10.1148/radiol.2313021488
-
Hoeffner EG, Case I, Jain R et al (2004) Cerebral perfusion CT: technique and clinical applications. Radiology 231:632-644 (Pubitemid 38668077)
-
(2004)
Radiology
, vol.231
, Issue.3
, pp. 632-644
-
-
Hoeffner, E.G.1
Case, I.2
Jain, R.3
Gujar, S.K.4
Shah, G.V.5
Deveikis, J.P.6
Carlos, R.C.7
Thompson, B.G.8
Harrigan, M.R.9
Mukherji, S.K.10
-
26
-
-
85047174301
-
Radiation effects from perfusion CT
-
author reply 638
-
Frey GD, Rumboldt Z (2005) Radiation effects from perfusion CT. Radiology 234:638, author reply 638
-
(2005)
Radiology
, vol.234
, pp. 638
-
-
Frey, G.D.1
Rumboldt, Z.2
-
27
-
-
79951822981
-
Noise reduction and image quality improvement of low dose and ultra low dose brain perfusion CT by HYPR-LR processing
-
Krissak R, Mistretta CA, Henzler T et al (2011) Noise reduction and image quality improvement of low dose and ultra low dose brain perfusion CT by HYPR-LR processing. PLoS ONE 6:e17098
-
(2011)
PLoS ONE
, vol.6
-
-
Krissak, R.1
Mistretta, C.A.2
Henzler, T.3
|